Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Sr, Nd, and Pb isotopes in Proterozoic intrusives astride the Grenville Front in Labrador - Implications for crustal contamination and basement mapping

Trace element and Pb, Sr, and Nd isotopic compositions of anorthosites and related rocks, and of younger mafic dikes from Harp Lake and Mealy Mountains in Labrador, Canada are estimated and compared. The effects of crustal component contaminants on the isotopic compositions of the dikes are investigated. The correlation between the isotopic data and the crustal contamination model is studied. It is observed that for Harp Lake the initial Sr ratios are higher and the Nd values are lower than Mealy samples, and the data do not correspond to the crustal contamination model; however, the Pb isotope data favor a crustal contamination model. It is noted that the Labrador segment of the Grenville Front appears to coincide with the southern margin of the Archean North Atlantic craton, and may represent a pre mid-Proterozoic suture.

Ashwal, L. D.↗

Study on contaminants on flight and other critical surfaces

The control of surface contamination in the manufacture of space hardware can become a critical step in the production process. Bonded surfaces have been shown to be affected markedly by contamination. It is important to insure surface cleanliness by preventing contamination prior to bonding. In this vein techniques are needed in which the contamination which may affect bonding are easily found and removed. Likewise, if materials which are detrimental to bonding are not easily removed, then they should not be used in the manufacturing process. This study will address the development of techniques to locate and quantify contamination levels of particular contaminants. With other data becoming available from MSFC and its contractors, this study will also quantify how certain contaminants affect bondlines and how easily they are removed in manufacturing.

Workman, Gary L.↗

Derivation of Acoustic Criteria for the Cassini Spacecraft and Comparison with Flight Data

Acoustic measurements from eight pre-Cassini Titan IV flights, and an acoustic test of a Cassini simulator and Titan payload fairing (PLF), were used to derive acoustic flight and test criteria for the Cassini spacecraft. The flight and ground test data were used or modified to account for the following factors: (a) noise-spike contamination of flight data, (b) spatial and flight-to-flight variations of flight data, (c) application of a thicker banier-blanket to the PLF for the Cassini mission, (d) effects of locating two Cassini assemblies, the Huygens Probe, and the High Gain Antenna (HGA), near the PLF, and (e) higher thrust of upgraded Titan solid rocket motors (SRMS) for the Cassini mission. An overall sound pressure level (OA SPL) of 145 dB was verified for the protoflight acoustic test criteria for the Cassini spacecraft. Cassini flight liftoff data showed an average OA SPL of 133 dB.

Himelblau, Harry↗

Technetium oxidation in slag-based sodium salt waste forms exposed to water and moist Hanford soil - 15514

Several U.S. DOE sites use or plan to use waste forms and/or concrete containment structures for radioactive waste disposal that are designed to have a chemically reducing environment to immobilize selected contaminants such as Tc(VII)O{sub 4}{sup -} and Cr(VI)O{sub 4}{sup 2-}. These waste forms and containment structures are typically deployed in near surface unsaturated oxidizing environments. Consequently, the effect of exposure to air (oxygen) and water containing dissolved oxygen during production, during the period of institutional control, and over the long term period of performance is important for predicting the speciation and mobility of the redox sensitive radioactive and stable contaminants. Both the SRS and Hanford waste streams contain soluble technetium which may require stabilization to meet disposal requirements. Technetium stabilization is a difficult problem because: 1) Tc is soluble and very mobile in the oxidized form typical of near surface environments, and 2) Tc-99 is a long-lived isotope with a half-life of 2.1 E+05 years which places demanding requirements on the engineered barriers and environment to meet current regulatory disposal requirements. A depth-discrete sampling and leaching method approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) was used in this study. The method was modified by coating all sides of a cylindrical sample with an impermeable epoxy and cutting a fresh surface 2 to 2.5 cm from the original top surface eliminates sample inhomogeneity as the result of settling as a reason from observed results and provides 1-D soluble ion transport and gas transport information. Soluble Tc was leached from all of the depth-discrete sub-samples from both Tc2-9 and Tc2-10 which strongly suggests that oxygen was present in the entire length of both samples. About 24 mass percent of the Tc in the original sample, was leached (soluble) from sub-samples between 0.8 and 46 mm below the exposed surface of Tc2-9 (exposed to Hanford sediment). The same percent (24%) was leached from the sub-samples between 0.8 and 11 mm below the exposed surface of Tc2-10 (exposed to DI water). This suggests that the rate of oxygen migration into the sample exposed to soil was faster than the rate of migration into the sample exposed to water which is consistent with the more rapid transport of ions through a gas phase as compared to a liquid phase. It is assumed that moisture in the Hanford sediment was not sufficient to completely block the surface pores with respect to gas transport across the soil-waste form boundary. Based on nitrate leaching results for the depth- discrete sub-samples, regions depleted in nitrates were identified from the top surfaces to 9.5 and 3 mm into samples Tc2-9 (exposed to moist Hanford sediment) and Tc2-10 (DI water). Low mass fractions of nitrate were leached from these depth-discrete samples compared to samples further from the exposed surface presumably because a significant portion of the nitrate had already migrated into the soil or water, respectively. Depth-discrete sub-sample leaching results for Na can be interpreted in the same way over the same regions in the two samples tested. In conclusion, leaching monolithic porous cementitious waste forms in water appears to be conservative for non-redox sensitive contaminants. However, leaching data obtained under saturated exposure conditions do not appear to be conservative for redox sensitive contaminants which are easily oxidized. Leaching crushed samples in water still seems to be a conservative approach to estimating the concentrations of soluble contaminants in a waste form. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PARAMETRIC TENSION BETWEEN EVEN AND ODD MULTIPOLE DATA OF THE WMAP POWER SPECTRUM: UNACCOUNTED CONTAMINATION OR MISSING PARAMETERS?

There exists power contrast in even and odd multipoles of the WMAP power spectrum at low and intermediate multipole ranges. This anomaly is explicitly associated with the angular power spectrum, which is heavily used for cosmological model fitting. Having noted this, we have investigated whether even (odd) multipole data set is individually consistent with the WMAP concordance model. Our investigation shows that the WMAP concordance model does not make a good fit for even (odd) multipole data set, which indicates parametric tension between even and odd multipole data set. Noting that tension is highest in primordial power spectrum parameters, we have additionally considered a running spectral index, but found that tension increases to even a higher level. We believe these parametric tensions may be indications of unaccounted contamination or imperfection of the model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation of the Hubble Space Telescope (HST) Space Telescope Imaging Spectrometer (STIS) On-Orbit Data with Pre-launch Predictions and Ground Contamination Controls

The Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) was deployed on-orbit in February 1997. The contamination program for STIS was stringently controlled as the five-year end-of-life deposition was set at 158, per optical element. Contamination was controlled through materials selection, extensive vacuum outgassing certifications, cleaning techniques, and environmental controls. In addition to ground contamination controls, on-orbit contamination controls were implemented for both the HST servicing mission activities and early post-servicing mission checkout. The extensive contamination control program will be discussed and the STIS on-orbit data will be correlated with the prelaunch analytical predictions.

Hansen, Patricia A.↗

The De-Icing Comparison Experiment – ARM Contribution (DICEXACO) Field Campaign Report

Longwave and shortwave radiative fluxes are fundamental quantities regularly observed globally using broadband radiometers. In regions conducive to frost, rime, and snow, ice frequently builds up on sensor windows, contaminating measurements. Since icing occurs under particular meteorological conditions, associated data loss constitutes a climatological bias. Furthermore, the signal caused by ice is difficult to distinguish from that of clouds, hampering efforts to identify contaminated data in post-processing. Because of the sensitivity of radiometers to internal temperature instabilities, there are limitations to using heat as a de-icing method, and consequently substantial amounts of data are lost. The De-Icing Comparison Experiment (D-ICE) was a campaign carried out at $Utqia\dot{g}vik$ (formerly known as Barrow) and Oliktok Point, Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational stations run by the NOAA Global Monitoring Division (GMD) at NOAA’s Barrow Atmospheric Baseline Observatory. D-ICE also evaluated the sky radiometer (SKYRAD) systems at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) and Oliktok Point (OLI; third ARM Mobile Facility [AMF3]) observatories. In total, 34 systems were evaluated (8 of which were SKYRAD radiometers). All radiometers were monitored continuously using cameras, and a total of more than one million images of sensor domes were archived collectively between the stations. Data collected as part of D-ICE by NOAA can be found through the project web page, https://www.esrl.noaa.gov/psd/arctic/d-ice/. The DICEXACO component of D-ICE (https://www.arm.gov/research/campaigns/nsa2017dicexaco) are the images collected at 10-min intervals at both OLI and NSA and are the subject of this report. Two cameras were installed at each ARM station, one directed towards the SKYRAD tracker and the other towards the SKYRAD global precision spectral pyranometer (PSP).

Oliktok Point, North Slope of Alaska, SKYRAD, pyra↗

Determination of elemental impurities in plastic calibration standards using laser induced breakdown spectroscopy

Dual-energy computed tomography (CT) scanning is a rapidly emerging imaging technique employed in nondestructive evaluation of various materials. CT has been used for characterizing rocks and visualizing multiphase flow through rocks for over 25 years. The most common technique for dual-energy CT scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. Laser-induced breakdown spectroscopy was used to determine impurity concentration in a set of commercially purchased calibration standards used in dual-energy scanning for material identification with coal samples. Two calibration models were developed by using univariate calibration with the internal ratio method and multiple linear regression. Seven elements (Al, Fe, Mg, Na, Ni, Sr, and Ti) were examined in five different samples containing varying amounts of each ion to compare calibration from univariate data analysis and from multivariate data analysis. The contaminant concentrations were also measured by a commercially available inductively coupled plasma optical emission spectroscopy instrument, and the data were used as a reference in developing calibration curves for a modified version of the single linear regression model and the multiple linear regression model.

01 COAL, LIGNITE, AND PEAT↗

Study of payload sensor contamination

Epoxy/glass test specimens representing Scout fourth and fifth stage motor casings were prepared and studied in a test program designed to determine the relative contamination contributed to payload sensors located near the motor casings. The relative contamination detected in the test program was dependent on several factors, including: (1) distance of test specimen to sensor, (2) sensor temperature, (3) geometric position of the sensor (relative to test specimen), (4)test specimen temperature, (5) chemical composition of the test specimen, (6) sensor function, and (7) additional materials (such as adhesive-backed aluminum tape) added to the test specimens. The thermal characteristics and the decomposition and outgassing products were determined. These data were used to better understand the relative contamination data from the remote sensor testing.

Smith, F. J.↗

Verification of surface preparation for adhesive bonding

A survey of solid rocket booster (SRB) production operations identified potential contaminants which might adversely affect bonding operations. Lap shear tests quantified these contaminants' effects on adhesive strength. The most potent contaminants were selected for additional studies on SRB thermal protection system (TPS) bonding processes. Test panels were prepared with predetermined levels of contamination, visually inspected using white and black light, then bonded with three different TPS materials over the unremoved contamination. Bond test data showed that white and black light inspections are adequate inspection methods for TPS bonding operations. Extreme levels of contamination (higher than expected on flight hardware) had an insignificant effect on TPS bond strengths because of the apparent insensitivity of the adhesive system to contamination effects, and the comparatively weak cohesive strength of the TPS materials.

Myers, Rodney S.↗

The Atacama Cosmology Telescope: Data Characterization and Map Making

We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% or the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 142h of data (11 TB for the 148 GHz band only), with a daily average of 10.5 h of observation. From these, 108.5 h were devoted to 850 sq deg stripe (11.2 h by 9 deg.1) centered on a declination of -52 deg.7, while 175 h were devoted to a 280 square deg stripe (4.5 h by 4 deg.8) centered at the celestial equator. We discuss sources of statistical and systematic noise, calibration, telescope pointing and data selection. Out of 1260 survey hours and 1024 detectors per array, 816 h and 593 effective detectors remain after data selection for this frequency band, yielding a 38 % survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 muK square root of s in CMB units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector and noise covariance at low frequencies in the TOD. The maps were made by solving the lease squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Cross-correlation with WMAP sky maps as well as analysis from simulations reveal the our maps are unbiased at l > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.

Duenner, Rolando↗

Assessment of doses in contaminated urban areas: modelling exercise based on Fukushima data

State-of-the-art dose assessment models were applied to estimate doses to the population in urban areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Assessment results were compared among five models, and comparisons of model predictions with actual measurements were also made. Assessments were performed using both probabilistic and deterministic approaches. Predicted dose distributions for indoor and outdoor workers from a probabilistic approach were in good agreement with the actual measurements. In addition, when the models were applied to assess the doses to the representative person, based on a concept recommended by the International Commission on Radiological Protection and in the International Atomic Energy Agency Safety Standards, it was evident that doses to the representative person obtained with a deterministic approach were always higher than those obtained with a probabilistic approach using the same model.

dose assessment↗

THE ATACAMA COSMOLOGY TELESCOPE: DATA CHARACTERIZATION AND MAPMAKING

We present a description of the data reduction and mapmaking pipeline used for the 2008 observing season of the Atacama Cosmology Telescope (ACT). The data presented here at 148 GHz represent 12% of the 90 TB collected by ACT from 2007 to 2010. In 2008 we observed for 136 days, producing a total of 1423 hr of data (11 TB for the 148 GHz band only), with a daily average of 10.5 hr of observation. From these, 1085 hr were devoted to an 850 deg{sup 2} stripe (11.2 hr by 9. Degree-Sign 1) centered on a declination of -52. Degree-Sign 7, while 175 hr were devoted to a 280 deg{sup 2} stripe (4.5 hr by 4. Degree-Sign 8) centered at the celestial equator. The remaining 163 hr correspond to calibration runs. We discuss sources of statistical and systematic noise, calibration, telescope pointing, and data selection. For the 148 GHz band, out of 1260 survey hours and 1024 detectors in the array, 816 hr and 593 effective detectors remain after data selection, yielding a 38% survey efficiency. The total sensitivity in 2008, determined from the noise level between 5 Hz and 20 Hz in the time-ordered data stream (TOD), is 32 {mu}K{radical}s in cosmic microwave background units. Atmospheric brightness fluctuations constitute the main contaminant in the data and dominate the detector noise covariance at low frequencies in the TOD. The maps were made by solving the least-squares problem using the Preconditioned Conjugate Gradient method, incorporating the details of the detector and noise correlations. Simulations, as well as cross-correlations with Wilkinson Microwave Anisotropy Probe sky maps on large angular scales, reveal that our maps are unbiased at multipoles l > 300. This paper accompanies the public release of the 148 GHz southern stripe maps from 2008. The techniques described here will be applied to future maps and data releases.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Soil Vapor Extraction Data to Evaluate Mass-Transfer Constraints and Estimate Source-Zone Mass Flux

Methods are developed to use data collected during cyclic operation of soil vapor extraction (SVE) systems to help characterize the magnitudes and timescales of mass flux associated with vadose zone contaminant sources. Operational data collected at the Department of Energy’s Hanford site are used to illustrate the use of such data. An analysis was conducted of carbon tetrachloride vapor concentrations collected during and between SVE operations. The objective of the analysis was to evaluate changes in concentrations measured during periods of operation and non-operation of SVE, with a focus on quantifying temporal dynamics of the vadose zone contaminant mass flux, and associated source strength. Three mass-flux terms, representing mass flux during the initial period of a SVE cycle, during the asymptotic period of a cycle, and representing mass flux during the rebound periods, were calculated and compared. It was shown that it is possible to use the rebound data to estimate time frames for effective operation of an SVE system if a sufficient set of historical cyclic operational data exists. This information could then be used to help evaluate changes in SVE operations, including system closure.

54 ENVIRONMENTAL SCIENCES↗

Impact of In Situ Chemical Oxidation on Contaminant Mass Discharge: Linking Source-Zone and Plume-Scale Characterizations of Remediation Performance

A large-scale permanganate-based in situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly accessible contaminant mass residing within lower permeability zones.

54 ENVIRONMENTAL SCIENCES↗

Grain-Size Based Additivity Models for Scaling Multi-rate Uranyl Surface Complexation in Subsurface Sediments

This study statistically analyzed a grain-size based additivity model that has been proposed to scale reaction rates and parameters from laboratory to field. The additivity model assumed that reaction properties in a sediment including surface area, reactive site concentration, reaction rate, and extent can be predicted from field-scale grain size distribution by linearly adding reaction properties for individual grain size fractions. This study focused on the statistical analysis of the additivity model with respect to reaction rate constants using multi-rate uranyl (U(VI)) surface complexation reactions in a contaminated sediment as an example. Experimental data of rate-limited U(VI) desorption in a stirred flow-cell reactor were used to estimate the statistical properties of multi-rate parameters for individual grain size fractions. The statistical properties of the rate constants for the individual grain size fractions were then used to analyze the statistical properties of the additivity model to predict rate-limited U(VI) desorption in the composite sediment, and to evaluate the relative importance of individual grain size fractions to the overall U(VI) desorption. The result indicated that the additivity model provided a good prediction of the U(VI) desorption in the composite sediment. However, the rate constants were not directly scalable using the additivity model, and U(VI) desorption in individual grain size fractions have to be simulated in order to apply the additivity model. An approximate additivity model for directly scaling rate constants was subsequently proposed and evaluated. The result found that the approximate model provided a good prediction of the experimental results within statistical uncertainty. This study also found that a gravel size fraction (2-8mm), which is often ignored in modeling U(VI) sorption and desorption, is statistically significant to the U(VI) desorption in the sediment.

Zhang, Xiaoying↗

EIGHT-DIMENSIONAL MID-INFRARED/OPTICAL BAYESIAN QUASAR SELECTION

We explore the multidimensional, multiwavelength selection of quasars from mid-infrared (MIR) plus optical data, specifically from Spitzer-Infrared Array Camera (IRAC) and the Sloan Digital Sky Survey (SDSS). Traditionally, quasar selection relies on cuts in two-dimensional color space despite the fact that most modern surveys (optical and IR) are done in more than three bandpasses. In this paper, we apply modern statistical techniques to combined Spitzer MIR and SDSS optical data, allowing up to eight-dimensional (8-D) color selection of quasars. Using a Bayesian selection method, we catalog 5546 quasar candidates to an 8.0 {mu}m depth of 56 {mu}Jy over an area of {approx}24 deg{sup 2}. Roughly 70% of these candidates are not identified by applying the same Bayesian algorithm to 4-color SDSS optical data alone. The 8-D optical+MIR selection on this data set recovers 97.7% of known type 1 quasars in this area and greatly improves the effectiveness of identifying 3.5 < z < 5 quasars which are challenging to identify (without considerable contamination) using MIR data alone. We demonstrate that, even using only the two shortest wavelength IRAC bandpasses (3.6 and 4.5 {mu}m), it is possible to use our Bayesian techniques to select quasars with 97% completeness and as little as 10% contamination (as compared to {approx}60% contamination using color cuts alone). We compute photometric redshifts for our sample; comparison with known objects suggests a photometric redshift accuracy of 93.6% ({delta}z {+-} 0.3), remaining roughly constant when the two reddest MIR bands are excluded. Despite the fact that our methods are designed to find type 1 (unobscured) quasars, as many as 1200 of the objects are type 2 (obscured) quasar candidates. Coupling deep optical imaging data, with deep MIR data, could enable selection of quasars in significant numbers past the peak of the quasar luminosity function (QLF) to at least z {approx} 4. Such a sample would constrain the shape of the QLF both above and below the break luminosity (L* {sub Q}) and enable quasar clustering studies over the largest range of redshift and luminosity to date, yielding significant gains in our understanding of the physics of quasars and their contribution to galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

The influence of man in space observations

The paper evaluates the Skylab missions from the viewpoint of to what extent the presence of men may have been a detriment to scientific observations, either through their movements or through contamination of the spacecraft and instruments. The stability of the instrument canister within the Apollo Telescope Mount was secured by the Experiment Pointing Control System. Angular stability was specified to be within plus or minus 2.5 arc seconds, and was found to be less than 2 arc seconds during normal crew activity. No astronomical observations were reported as being degraded by crew movements. Instrumentation was installed to measure rates of contaminant particle deposition on optical surfaces. Clouds were formed from particles originating in outgassing from vehicle surface materials and from vent apertures. The Coronograph Contamination Measurement Instrument was used to measure the brightness of the induced cloud surrounding Skylab. Preliminary analysis shows no significant degradation of photographic data attributable to contamination.

Hanes, T. E.↗