Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Analysis and Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Survey and Benchmark of Benefits of High Voltage SiC Applications in Medium Voltage Power Distribution Grids

The main objective of this survey and benchmark study is to identify and document potential high-impact applications in today's and future medium voltage (MV) distribution grids that will significantly benefit from high voltage (HV) (i.e. > 3.3 kV) SiC-based power electronics equipment. In particular, it is desirable to identify applications that can utilize the high switching speed and high control bandwidth enabled by SiC-based equipment. Specifically, the benefits of using SiC are quantified through the benchmark analysis and design using simulation for the selected high-impact applications. In addition, to provide grid support services, it is necessary to consider grid requirements in the grid-connected converter's design. Therefore, the impact of grid requirements on the HV SiC-based grid-connected converter is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Control of Process Variance Using Feedback

For many stochastic control problem formulations, design objectives typically include constraining the covariance of the outputs of the system. Recent engineering challenges have demonstrated an interest in controlling system output covariances to a setpoint. However, open-loop control of system output covariance can be exceptionally challenging when the system has significant plant uncertainties. This paper explores closed-loop control of the system’s output covariance using a windowed variance function. The stochastic nature of the windowed variance feedback means that root locus and other classical control design techniques cannot be immediately used. Expected value analysis is used to generate transfer functions for the average response of such systems, and the results are used to design controllers. Stochastic simulations are presented to verify the analytical results and make other observations concerning closed-loop variance control.

Bieniek, Mitchell↗

Investigation of the iodate sorption mechanism by CoAl LDH through experiments and ab initio molecular dynamics simulations

Radioiodine released during the nuclear-fuel cycle constitutes a persistent radiological hazard. In this study, the IO 3 – uptake mechanism of CoAl LDH was resolved by combining pH-controlled sorption experiments, synchrotron XAFS, and DFT-based AIMD simulations. At pH close to 6, approximately 90% of IO 3 – was removed, and the equilibrium distribution coefficient reached about 1.7 × 10 4 mL g –1 . EXAFS analysis indicated an average iodine–oxygen bond length of 1.81 Å and a coordination number near 3, with the fit R-factor equal to 0.002. The simulations faithfully reproduced the experimental spectrum and revealed transient proton hopping events that generated metastable I–O–H species inside the interlayer, thereby confirming nitrate-to-iodate exchange as the controlling capture pathway. Atomic density profiles and radial distribution functions further showed that IO 3 – adopt an end-on orientation perpendicular to the hydroxide sheets, while water molecules mediate proton migration without disturbing the host lattice. In conclusion, the integrated experimental–computational evidence demonstrates that CoAl LDH can rapidly and selectively sequester IO 3 – under near-neutral conditions, offering atomic scale guidance for the rational engineering of layered sorbents for advanced radioactive-waste treatment.

Kang, Jaehyuk [Jeju National Univ. (Korea, Republi↗

Connected Traffic Signal Coordination Optimization Framework through Network-Wide Adaptive Linear Quadratic Regulator–Based Control Strategy

Traffic congestion in metropolitan areas causes several significant challenges, such as longer travel times, decreased productivity, increased fuel consumption and vehicle emissions, and even severe injuries during crashes. Traffic signal control is a management approach to reduce traffic congestion and allocate the appropriate right of way for safety and mobility efficiency, both in temporal and spatial domains. Here, this study proposes a network-wide adaptive signal control coordination optimization framework based on the linear quadratic regulator algorithm. The traffic flow conditions driven by signal control inputs are formulated based on their network-wide state-space representation. After modeling traffic control regulation constraints, an adaptive linear quadratic regulator algorithm is designed to maximize the network-wide total throughput under the current conditions. Optimal signal control split time durations for multiple intersections in the network are derived by solving the algebraic Riccati equation. Furthermore, the recursive least square parameter estimation method is employed to quantify dynamic traffic condition changes. To verify the effectiveness of this proposed signal control framework, both simulation and real-world experimental tests are conducted for multiple intersections in downtown Chattanooga, Tennessee, United States. In preparation for real-world experimental tests, pipelines for real-time data processing implementation and historical traffic flow data analysis are conducted. The test results demonstrate that the proposed control framework achieves a decrease in travel time by up to 19.4%, total time spent (TTS) by up to 11.9%, and relative queue balance (RQB) by up to 15.6%. The research findings indicate that the proposed signal control framework can be generalized to handle large scale signal control optimization network-wide.

97 MATHEMATICS AND COMPUTING↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ARCADE (Advanced Reactor Cyber Analysis and Development Environment)

SAND2025-11780O ARCADE (Advanced Reactor Cyber Analysis and Development Environment) software performs cybersecurity experiments on Defensive Cyber Security Architectures (DCSA) for Distributed Control Systems (DCSs). The application is integrated into a cohesive environment that performs cyber risk analyses and reduces costs. ARCADE can investigate the entire cyber-attack surface of a DCS from the physics of control, down to the firmware of individual components with automated efficiency. ARCADE has five major functional components: the Data Broker system, the virtualization environment, the cyber-attack simulator, the cyber-physical analysis system, and the physics simulator. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Valme, Romuald↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Domain Impedance Theory for the Analysis and Mitigation of Interarea Oscillations: Preprint

This paper presents an impedance-based theory for the analysis and mitigation of interarea oscillations in power systems. Because low-frequency power system oscillations primarily manifest in phasor quantities, including active and reactive power flows, and the magnitude and frequency of bus voltages, a new-type of impedance, called power-domain impedance, is defined in terms of these phasor quantities. The power-domain impedance provides an intuitive framework for the analysis of interarea oscillations without requiring internal details of generators, and it is ideally suited for developing oscillation damping controls in inverter-based resources. The power-domain impedance theory is demonstrated in this paper using PSCAD simulations of a two-area system. The theory is also used for designing damping control in synchronous generators and a wind power plant in the two-area system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Priming mechanisms providing plants and microbes access to mineral-associated organic matter

Mineral-associated organic matter (MAOM) is considered a stable reservoir for soil nutrients that influences long-term soil carbon (C) and nitrogen (N) dynamics. However, recent experimental and theoretical evidence shows that root exudates may mobilize MAOM, thereby providing plants and microbes access to a large and N-rich pool. Given the mechanisms underlying MAOM C and N mobilization remain largely untested, we examined direct and indirect pathways by which root exudates destabilize this nutrient pool in laboratory mesocosms. We simulated root exudation with 13 C-labeled oxalic acid to test whether root exudates are directly capable of mobilizing MAOM from mineral surfaces; and with 13 C-labeled glucose to test whether indirect stimulation of microbial and extracellular enzyme activity leads to MAOM decomposition. We also tested the potential for oxalic acid and glucose to mobilize MAOM in an additional subset of sterilized soils to clarify the potential for non-microbial pathways of MAOM destabilization. Over the course of the 12-day MAOM incubation with and without simulated exudates, we measured C cycling (CO 2 respiration rates, 13 C–CO 2 efflux), N cycling (inorganic N pools, gross N mineralization) and related microbial processes (enzyme activities and microbial community composition via phospholipid fatty acid analysis). Both of the simulated root exudates enhanced MAOM-C mineralization, with cumulative respiration increasing 35–89% relative to the water-only control. Likewise, glucose additions enhanced the production of an exo-cellulase and a chitinase by up to 130% and 39%, respectively, while oxalic acid enhanced oxidative enzyme activities up to 91% greater than control rates. We observed a positive association between glucose-induced shifts in enzyme activities, MAOM-C mineralization, and gross ammonification. Oxalic acid additions were associated with initial increases in fungal relative abundance and in sterile soils appeared to stimulate the release of metals and dissolved organic nitrogen into exchangeable pools. Our results indicate that common root exudates, like glucose and oxalic acid, can significantly increase the turnover and potential release of C and N from MAOM through indirect (e.g., enzyme induction) and direct (e.g., mobilization of metal oxides) mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamics modeling of molten salt reactor with reduced and expanded representations of delayed neutron precursors

Molten salt reactors (MSRs) present unique challenges in dynamic behavior due to the mobility of their fuel. In these reactors, delayed neutron precursors (DNPs) drift with the fuel circulation through the primary loop. As a result, a fraction of DNPs decays outside the core, effectively reducing the available delayed neutron population for reactivity control. Consequently, precise modeling of the distribution and behavior of DNPs is critical for accurate reactor dynamics simulations. In this study, the System Dynamics Analysis Tool (SDAT) was used to simulate a thermal-spectrum MSR under steady-state conditions and following transients. The effects of using reduced and expanded representations of DNPs with fewer or more groups than the conventional 6-group model were investigated. Their impact on the simulated distribution of precursors in the primary loop, reactivity loss value, and reactor response to transients was analyzed. Simulation results showed that reduced models lead to the loss of the actual DNPs distribution data, resulting in less accurate estimates of reactivity loss. Reactor power predictions using these reduced models showed significant deviations compared to those using the conventional 6-group model in transient simulations. Expanded models offered a more accurate representation of the distribution of DNPs and reactivity loss estimates. Reactor power predictions using expanded models showed minimal deviation from the conventional 6-group model during the simulated transients.

analysis↗

Neuroevolution Application to Collaborative and Heuristics-Based Connected and Autonomous Vehicle Cohort Simulation at Uncontrolled Intersection

Artificial intelligence is gaining tremendous attractiveness and showing great success in solving various problems, such as simplifying optimal control derivation. This work focuses on the application of Neuroevolution to the control of Connected and Autonomous Vehicle (CAV) cohorts operating at uncontrolled intersections. The proposed method implementation’s simplicity, thanks to the inclusion of heuristics and effective real-time performance are demonstrated. The resulting architecture achieves nearly ideal operating conditions in keeping the average speeds close to the speed limit. It achieves twice as high mean speed throughput as a controlled intersection, hence enabling lower travel time and mitigating energy inefficiencies from stop-and-go vehicle dynamics. Low deviation from the road speed limit is hence continuously sustained for cohorts of at most 50 m long. This limitation can be mitigated with additional lanes that the cohorts can split into. The concept also allows the testing and implementation of fast-turning lanes by simply replicating and reconnecting the control architecture at each new road crossing, enabling high scalability for complex road network analysis. The controller is also successfully validated within a high-fidelity vehicle dynamic environment, showing its potential for driverless vehicle control in addition to offering a new traffic control simulation model for future autonomous operation studies.

Jacquelin, Frederic (ORCID:0000000183154344)↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Real-World Distribution System Modeling Framework for Transmission-and-Distribution Cosimulation: Preprint

This paper presents a modeling methodology for realistic distribution system simulation and analysis. The methodology involves three major approaches: utility model conversion, feeder load modeling, and feeder model validation. The feeder models obtained from the utility are converted to the format that is more flexible for analysis and algorithm development. The load profiles down to each node are modeled in detail using advanced metering infrastructure data and supervisory control and data acquisition (SCADA) system measured load data. Then the distribution system models are validated by comparing the simulated feeder-head voltage results and SCADA measured voltage data. To better understand the bulk system operations and the interactions between transmission and distribution systems, the modeled realistic distribution systems are integrated into a transmission-and-distribution cosimulation framework to perform the system simulation from the bulk system down to each node in the distribution system.

load modeling↗

Assessing turbulence and mixing parameterizations in the gray-zone of multiscale simulations over mountainous terrain during the METEX21 field experiment

Multiscale numerical weather prediction models transition from mesoscale, where turbulence is fully parameterized, to microscale, where the majority of highly energetic scales of turbulence are resolved. The turbulence gray-zone is situated between these two regimes and multiscale models must downscale through these resolutions. Here, we compare three multiscale simulations which vary by the parameterization used for turbulence and mixing within the gray-zone. The three parameterizations analyzed are the Mellor-Yamada Nakanishi and Niino (MYNN) Level 2.5 planetary boundary layer scheme, the TKE-1.5 large eddy simulation (LES) closure scheme, and a recently developed three-dimensional planetary boundary layer scheme based on the Mellor-Yamada model. The simulation domain includes complex (i.e., mountainous) terrain in Nevada that was instrumented with meteorological towers, profiling and scanning lidars, a tethered balloon, and a surface flux tower. Simulations are compared to each other and to observations, with assessment of model skill at predicting wind speed, wind direction and TKE, and qualitative evaluations of transport and dispersion of smoke from controlled releases. This analysis demonstrates that microscale predictions of transport and dispersion can be significantly influenced by the choice of turbulence and mixing parameterization in the terra incognita , particularly over regions of complex terrain and with strong local forcing. This influence may not be apparent in the analysis of model skill, and motivates future field campaigns involving controlled tracer releases and corresponding modeling studies of the turbulence gray-zone.

54 ENVIRONMENTAL SCIENCES↗