Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Systems Cyber Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Edge Deployed Cyber Security Hardware Architecture for Energy Delivery Systems

At a time of accelerated cyber conflict, an “edge deployed” system will supply sensor based cyber ground truth to live grid models, and under secure command, take complete control of suspected rogue programmable logic controllers (PLCs) to maintain bulk power delivery to chosen critical sites. This hardware solution is purpose built to be agnostic to PLC vendor or protocol with the realization that a widely deployed solution must function with existing devices for rapid adoption by industry. An overview of the situation and how this developed system functions is provided.

42 ENGINEERING↗

A Cybersecurity Event Simulation Tool and Platform

Digital Instrumentation and Control Systems (ICSs) have replaced analog control systems in nuclear power plants raising cybersecurity concerns. To study and understand the cybersecurity risks of nuclear power plants both high fidelity models of the plant physics and controllers must be created, and a framework to test and evaluate cyber security events must be established. A testing and evaluation framework of cybersecurity events consists of a method of interfering with control systems, a simulation of the plant network, and a network packet capture and recording tool. Sandia National Labs (SNL) in collaboration with the University of New Mexico’s Institute for Space and Nuclear Power Studies (UNM-ISNPS) is developing such a cybersecurity testing framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CONTROL AND DATA ACQUISITION IN A CYBER-PHYSICAL MIDSTREAM TESTBED

This thesis presents the development of a laboratory-scale cyber–physical midstream pipeline testbed designed to address this gap and support research in industrial control systems security. The platform integrates pumps, valves, sensors, programmable logic controllers (PLCs), and a human–machine interface (HMI) to emulate the monitoring and control architecture of real pipeline operations. The physical process is implemented as a closed-loop liquid circulation system designed to replicate flow behavior characteristic of midstream pipeline infrastructure. The testbed enables real-time data acquisition of key process variables, including flow rate and pressure facilitating the generation of datasets representative of normal pipeline operation. A threat model encompassing common ICS attack vectors was developed, including sensor spoofing, command injection, false data injection, denial-of-service attacks, and relay manipulation. Multiple attack scenarios were implemented and evaluated to demonstrate how cyber intrusions targeting sensors, actuators, networks, and software propagate into measurable physical consequences in pipeline flow and pressure. The developed platform serves as a practical, cost-effective environment for experimentation, education, and future cybersecurity research in midstream pipeline systems.

42 ENGINEERING↗

Support for Reactor Operators in Case of Cyber-Security Threats (NEUP Final Report)

Increasing use of digital technology in nuclear power plants (NPPs) poses cyber-security as a crucial threat to public safety and to continuous energy production. Cyber-security risks are comprised of complex known and unknown interactions between various entities, system vulnerabilities, network protocols, human users and malicious attacks. There is little understanding or research geared towards plant operators’ response under cyber-security threats and operational procedures to cope with such threats. This is particularly critical when a cyber-security event masquerades as a safety incident or an evolving accident. Instead of leading operators to the remediation of the accident, the masked cyber event may lead them to circumvent the safety mechanisms of the plant. Given these challenges, the objective of this project is to develop a tool to characterize abnormal NPP events as “cyber” or “safety” incidents, and to further develop this tool as a real-time operator aid to assist in response to the incident. This NEUP Final Report summarizes the research efforts towards the above goals and the results in the following three aspects. First, a methodology for classifying abnormal NPP events as cyber-attacks or safety incidents was developed. This provides the basis for responding to potential cyber-attacks. In this methodology, the causal relationships between various variables (i.e., physical variables, network variables, and control variables) for a nuclear system under consideration are modeled using dynamic Bayesian networks. Based on observations of certain variables (i.e., the evidence), inference is performed to identify the state of hidden variables, which helps indicate the occurrence of cyber-attacks or safety incidents. The proposed methodology was applied to the full scope NPP simulator system at The Ohio State University as a case study. The result shows that the proposed methodology is capable of distinguishing between cyber-attacks and safety incidents. Second, a game-theoretic approach for responding to cyber-attacks on nuclear power plants was developed. This is the second major goal of the project, and the method is used to recommend optimal responses to reactor operators in the case of cyber-attacks. We consider two cases in this research. In the first case, the interaction between the defender (i.e., the reactor operator) and the attacker is modeled as a two-player, nonzero-sum, Markov game with an infinite time horizon. In the second case, we consider a semi-Markov game between the defender and the attacker within a finite time horizon. The model in the second case enables us to consider the time sensitive response of the defender. In each case, the method for deriving the Nash equilibrium is developed. The Nash Equilibrium of the game provides the valid prediction of both players’ actions because no single player can benefit from unilaterally deviating from the equilibrium policy if the other player adheres to his/hers, hence it provides the best response of the defender to cyber-attacks. The proposed method in each case is demonstrated through a simplified benchmark digital feedwater control system. Third, a prototype display is developed to integrate the above information. The prototype display depicts the communication information to the operator and incorporates the cyber-security tool developed by the team into the interface. It consists of the regular display in current control rooms, as well as a panel used to indicate the occurrence of cyber-attacks or safety events and a panel used to guide the operator’s response to detected cyber-attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber/Physical Security Vulnerability Assessment Integration

Securing high value and critical assets is one of the biggest challenges facing this nation and others around the world. In modern integrated systems, there are four potential modes of attack available to an adversary: • physical only attack, • cyber only attack, • physical-enabled cyber attack, • cyber-enabled physical attack. Blended attacks involve an adversary working in one domain to reduce system effectiveness in another domain. This enables the attacker to penetrate further into the overall layered defenses. Existing vulnerability assessment (VA) processes and software tools which predict facility vulnerabilities typically evaluate the physical and cyber domains separately. Vulnerabilities which result from the integration of cyber-physical control systems are not well characterized and are often overlooked by existing assessment approaches. In this paper, we modified modification of the timely detection methodology, used for decades in physical security VAs, to include cyber components. The Physical and Cyber Risk Analysis Tool (PACRAT) prototype illustrates an integrated vulnerability assessment that includes cyber-physical interdependencies. Information about facility layout, network topology, and emplaced safeguards is used to evaluate how well suited a facility is to detect, delay, and respond to attacks, to identify the pathways most vulnerable to attack, and to evaluate how often safeguards are compromised for a given threat or adversary type. We have tested the PACRAT prototype on critical infrastructure facilities and the results are promising. Future work includes extending the model to prescribe the recommended security improvements via an automated cost-benefit analysis.

MacDonald, Douglas G.↗

Reinforcement Learning for feedback-enabled cyber resilience

The rapid growth in the number of devices and their connectivity has enlarged the attack surface and made cyber systems more vulnerable. As attackers become increasingly sophisticated and resourceful, mere reliance on traditional cyber protection, such as intrusion detection, firewalls, and encryption, is insufficient to secure the cyber systems. Cyber resilience provides a new security paradigm that complements inadequate protection with resilience mechanisms. A Cyber-Resilient Mechanism (CRM) adapts to the known or zero-day threats and uncertainties in real-time and strategically responds to them to maintain the critical functions of the cyber systems in the event of successful attacks. Feedback architectures play a pivotal role in enabling the online sensing, reasoning, and actuation process of the CRM. Reinforcement Learning (RL) is an important gathering of algorithms that epitomize the feedback architectures for cyber resilience. It allows the CRM to provide dynamic and sequential responses to attacks with limited or without prior knowledge of the environment and the attacker. In this work, we review the literature on RL for cyber resilience and discuss the cyber-resilient defenses against three major types of vulnerabilities, i.e., posture-related, information-related, and human-related vulnerabilities. Here we introduce moving target defense, defensive cyber deception, and assistive human security technologies as three application domains of CRMs to elaborate on their designs. The RL algorithms also have vulnerabilities themselves. We explain the major vulnerabilities of RL and present develop several attack models where the attacker target the information exchanged between the environment and the agent: the rewards, the state observations, and the action commands. We show that the attacker can trick the RL agent into learning a nefarious policy with minimum attacking effort. The paper introduces several defense methods to secure the RL-enabled systems from these attacks. However, there is still a lack of works that focuses on the defensive mechanisms for RL-enabled systems. Last but not least, we discuss the future challenges of RL for cyber security and resilience and emerging applications of RL-based CRMs.

97 MATHEMATICS AND COMPUTING↗

Hardware-Based Randomized Encoding for Sensor Authentication in Power Grid SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems are utilized extensively in critical power grid infrastructures. Modern SCADA systems have been proven to be susceptible to cyber-security attacks and require improved security primitives in order to prevent unwanted influence from an adversarial party. One section of weakness in the SCADA system is the integrity of field level sensors providing essential data for control decisions at a master station. In this paper we propose a lightweight hardware scheme providing inferred authentication for SCADA sensors by combining an analog to digital converter and a permutation generator as a single integrated circuit. Through this method we encode critical sensor data at the time of sensing, so that unencoded data is never stored in memory, increasing the difficulty of software attacks. We show through experimentation how our design stops both software and hardware false data injection attacks occurring at the field level of SCADA systems.

42 ENGINEERING↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Behavior Computation for Smart Grid Software Analysis

Smart grid embedded software is subject to intrusion and compromise with potentially serious consequences. Current methods of cybersecurity analysis are increasingly challenged by the scope the problem. Oak Ridge National Laboratory (ORNL) is pioneering the new technology of software behavior computation to help address these risks. Software behavior computation and its instantiation in Function eXtraction (FX) systems apply mathematical foundations of denotational semantics to compute the behavior of software in all circumstances of use. Research has shown how to make the effects of recursion-theoretic limitations on this process arbitrarily small. Behavior computation operates on the functional semantics of programs, and is not subject to the limitations of syntactic recognition or testing. ORNL is applying FX technology to help evaluate cyber security properties in smart grid systems, with initial focus on vulnerabilities in embedded software that controls smart meters.

denotational semantics↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Spatio-Temporal Characterization of Synchrophasor Data Against Spoofing Attacks in Smart Grids

“Source ID Mix” has emerged as a new type of highly deceiving attack which can alter the source information of synchrophasor data measured by multiple phasor measurement units, thereby paralyzing many wide-area measurement systems applications. To address such sophisticated cyber attacks, we have exploited the spatio-temporal characteristics of synchrophasor data for authenticating measurements’ source information. Specifically, the source authentication is performed when the measurements are subjected to three types of spoofing attacks. Some practical difficulties in applying the proposed method on real-time authentication caused by insufficient measurement data have also been solved. Experimental results with real synchrophasor measurements have validated the effectiveness of the proposed method in detecting such complicated data spoofing and improving power systems’ cyber security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Demonstration of a Security Core Component

In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more data about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from “normal,” CSM can alert the operator in language that they understand that an incident may be occurring, provide actionable intelligence, and informing them what actions to take. These alarms may be viewed on CSM’s built-in user interface, sent to a SCADA alarm list, or communicated via email, phone, pager, or SMS message. In recognition of the fact that “real world” training for cyber security events is impractical, CSM has a built-in Operator Training Simulator capability. This can be used stand alone to create simulated event scenarios for training purposes. It may also be used in conjunction with the recipient’s SCADA/EMS/DMS Operator Training Simulator. In addition to providing cyber security situational awareness for electric utility operators, CSM also provides tools for analysts and support personnel; in fact, the majority of user interface displays are designed for use in analyzing current and past security events. CSM keeps security-related information in long-term storage, as well as writing any decisions it makes to a (syslog) log for use forensic or other post-event analysis.

Turke, Andy↗

Finite Energy and Bounded Actuator Attacks on Cyber-Physical Systems

As control system networks are being connected to enterprise level networks for remote monitoring, operation, and system-wide performance optimization, these same connections are providing vulnerabilities that can be exploited by malicious actors for attack, financial gain, and theft of intellectual property. Much effort in cyber-physical system (CPS) protection has focused on protecting the borders of the system through traditional information security techniques. Less effort has been applied to the protection of cyber-physical systems from intelligent attacks launched after an attacker has defeated the information security protections to gain access to the control system. In this paper, attacks on actuator signals are analyzed from a system theoretic context. The threat surface is classified into finite energy and bounded attacks. These two broad classes encompass a large range of potential attacks. The effect of theses attacks on a linear quadratic (LQ) control are analyzed, and the optimal actuator attacks for both finite and infinite horizon LQ control are derived, therefore the worst case attack signals are obtained. The closed-loop system under the optimal attack signals is given and a numerical example illustrating the effect of an optimal bounded attack is provided.

Djouadi, Seddik M↗

Cyber threat assessment of machine learning driven autonomous control systems of nuclear power plants

We report advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)-based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber–physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems.

99 GENERAL AND MISCELLANEOUS↗

EV SALaD 2023 Demonstration: Best Practices and Mitigations for Protecting EVSE Infrastructure

The Electric Vehicle Secure Architecture Laboratory Demonstration (EV SALaD) program is a demonstration of cybersecurity best practices for high-power electric vehicle (EV) charging infrastructure led by Idaho National Laboratory (INL), in collaboration with other DOE National Laboratories participating in the EVs at Scale Consortium.a Sandia National Laboratories (SNL) and Pacific Northwest National Laboratory (PNNL) participated in the first 2-year (FY22-23) demonstration cycle for EV SALaD. This report documents the FY23 demonstration, the second in a series of demonstrations and collaborations in deploying and operating cybersecure EV charging infrastructure. It includes a summary of improvements from the FY22 demonstration, technical analysis of the FY23 demonstration, how the research demonstrates cyber-physical and cybersecurity best practices for high-power EV charging infrastructure, and related impacts to national and energy security. For EV SALaD, the FY22 demonstration focused on the detection, ranking, and prioritization of anomalous events for high-power EV charging. The FY23 demonstration additionally included the demonstration of cybersecurity best practices, which included protection and mitigation solutions to prevent, respond, and recover from anomalous events. During the demonstrations, the multi-lab EV SALaD team conducted a Test Effect Payload (TEP)b evaluation on extreme fast charger (XFC) hardware equipped with Cerberus, a detection and response solution, to demonstrate anomaly detection and mitigation cybersecurity best practices against cyber-enabled events.

33 ADVANCED PROPULSION SYSTEMS↗

Cyber Infrastructure for the Smart Electric Grid

As electric power systems undergo a transformative upgrade with the integration of advanced technologies to enable the smarter electric grid, professionals who work in the area require a new understanding of the evolving complexity of the grid. Cyber Infrastructure for the Smart Electric Grid delivers a comprehensive overview of the fundamental principles of smart grid operation and control, smart grid technologies, including sensors, communication networks, computation, data management, and cyber security, and the interdependencies between the component technologies on which a smart grid's security depends. The book offers readers the opportunity to critically analyze the smart grid infrastructure needed to sense, communicate, compute, and control in a secure way.

communication networks↗