Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Training Manual for Elements of Interface Definition and Control

The primary thrust of this manual is to ensure that the format and information needed to control interfaces between equipment are clear and understandable. The emphasis is on controlling the engineering design of the interface and not on the functional performance requirements of the system or the internal workings of the interfacing equipment. Interface control should take place, with rare exception, at the interfacing elements and no further. There are two essential sections of the manual. Chapter 2, Principles of Interface Control, discusses how interfaces are defined. It describes different types of interfaces to be considered and recommends a format for the documentation necessary for adequate interface control. Chapter 3, The Process: Through the Design Phases, provides tailored guidance for interface definition and control. This manual can be used to improve planned or existing interface control processes during system design and development. It can also be used to refresh and update the corporate knowledge base. The information presented herein will reduce the amount of paper and data required in interface definition and control processes by as much as 50 percent and will shorten the time required to prepare an interface control document. It also highlights the essential technical parameters that ensure that flight subsystems will indeed fit together and function as intended after assembly and checkout.

Lalli, Vincent R.↗

Inspection criteria ensure quality control of parallel gap soldering

Investigation of parallel gap soldering of electrical leads resulted in recommendation on material preparation, equipment, process control, and visual inspection criteria to ensure reliable solder joints. The recommendations will minimize problems in heat-dwell time, amount of solder, bridging conductors, and damage of circuitry.

Burka, J. A.↗

A Scalable Quantum Cryptography Network for Protected Automation Communication (Final Report)

This is the final report for a CEDS-funded project aimed at developing a new quantum technology for securing utility communication networks used to control and monitor electrical grid equipment. Securing these control networks represents a unique challenge as the performance of the security solution has a direct impact on the stability and reliability of the electrical grid. Traditional, software-based solutions - developed for information networks - are not suitable for utility control networks because they introduce latency, require burdensome maintenance and upgrades, are often incompatible with legacy equipment, and introduce operational complexity that reduces grid reliability. Consequently, many U.S. utilities do not use existing solutions and, instead, protect their critical control networks through the careful isolation and obscuration of their networked equipment. With more utilities embracing grid automation, the attack surface that utilities must defend from hackers has grown to an unmanageable size. To address this situation, Qubitekk and its partners proposed and developed a hardware-based solution that can secure critical control networks without negatively impacting grid performance. This new solution is based on quantum key distribution (QKD) techniques that guarantee secure key generation and distribution across a utility control network. Through deployment and field testing of a prototype QKD system, we have shown that this solution delivers long-term network security, is technically feasible to implement and maintain on a utility’s distribution substation network and does not negatively impact grid operations. In addition, the project has identified and solved key challenges associated with generating, transmitting, and measuring coherent photonic quantum states on a real-world fiber optic network. These additional findings are playing a critical role in advancing quantum networks for quantum computing applications. An overview of the QKD prototype development effort, field testing activities and results, and additional findings relevant to emerging quantum networks are presented in this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilization and control of the International Ultraviolet Explorer including a summary of flight performance

The paper discusses the International Ultraviolet Explorer Mission sequence, spacecraft equipment, and control laws. Flight data from the precision control modes are presented, to illustrate the performance achieved; the subarc second pointing at sources for 60 min periods is accomplished routinely. Two modes of precision control are available: one is of a bright guide star which is in the vicinity of the target source, so that the guidance mode includes a star tracker for position information and a gyro system for rate damping. When a guide star is not available, precision hold is accomplished solely on a well trimmed gyro reference with low frequency updates from a dim source. The three axis maneuvers, the maneuver angle, and the gyro data used are discussed, concluding that these data used in conjunction with star tracker data provide a good source of information for orbital performance evaluation.

Moore, J. V.↗

A cost and utility analysis of NIM/CAMAC standards and equipment for shuttle payload data acquisition and control systems. Volume 2: Tasks 1 and 2

A representative set of payloads for both science and applications disciplines were selected that would ensure a realistic and statistically significant estimate of equipment utilization. The selected payloads were analyzed to determine the applicability of Nuclear Instrumentation Modular (NIM)/Computer Automated Measurement Control (CAMAC) equipment in satisfying their data acquisition and control requirements. The analyses results were combined with the comparable results from related studies to arrive at an overall assessment of the applicability and commonality of NIM/CAMAC equipment usage across the spectrum of payloads.

Source record↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Oxygenated Fuel Blending Effects in a Mixing-Controlled Compression-Ignition Engine Equipped with Ducted Fuel Injection [Slides]

Continued creation of harmful emissions such as NO x and soot from compression-ignition engines utilizing mixing-controlled combustion systems (i.e., diesel engines) remains a problem and is the subject of on-going research. The inherently high efficiency, relatively low cost, and numerous other desirable attributes of such engines, coupled with a widely supported infrastructure, motivates their continued advancement. Recently, a scientifically distinct and mechanically simple technology called ducted fuel injection (DFI) has shown a robust ability to allow such engines to operate with simultaneously low engine-out soot and NO x emissions when it is employed with simulated exhaust-gas recirculation. To better understand the property ranges of sustainable, oxygenated-fuel blending stocks that will most improve engine performance, two oxygenated blendstocks were separately blended with a commercial diesel base fuel and tested within a heavy-duty diesel optical engine equipped with a four-duct DFI configuration. Conventional and crank-angle-resolved optical diagnostics were used to elucidate the effects of fuel ignition quality, oxygenate molecular structure, and overall oxygen content on engine performance.

33 ADVANCED PROPULSION SYSTEMS↗

Multivariate interactive digital analysis system /MIDAS/ - A new fast multispectral recognition system

The MIDAS system is a prototype, multiple-pipeline digital processor mechanizing the multivariate-Gaussian, maximum-likelihood decision algorithm operating at 200,000 pixels/second. It incorporates displays and film printer equipment under control of a general purpose midi-computer and possesses sufficient flexibility that operational versions of the equipment may be subsequently specified as subsets of the system.

Kriegler, F.↗

Theoretical Control-Centric Modeling for Precision Model-Based Sliding Mode Control of a Hydraulic Artificial Muscle Actuator

Artificial muscles (AMs) typically rely on pneumatic sources of fluid power. The use of hydraulics can increase the power and force to weight and volume ratios of AM actuators. This paper develops a control-centric third-order single-input single-output (SISO) lumped-parameter dynamic model and sliding mode position controller based on Filippov's principle of equivalent dynamics for a braided hydraulic artificial muscle (HAM) actuator. The model predicts the nonlinear behavior of the HAM free contraction and captures the fluid and actuator nonlinear dynamic interactions in addition to the braid deformation. Model simulations are compared to experimental results for quasi-static pressurization, isometric pressurization, and open-loop square wave commands at 0.25, 0.5, and 1 Hz. Experiments of sine wave tracking at 0.25, 0.5, and 1 Hz and continuous square wave tracking at 0.067 Hz are conducted using a sliding mode controller (SMC) derived from the model. The SMC achieves a steady-state error of 6 μm at multiple setpoints within the actuator's 17 mm stroke. Compared to a proportional-integral-derivative (PID) controller, the SMC root-mean-square (RMS) error, mean error, and absolute maximum error are reduced on average by 53%, 61%, and 44%, respectively, demonstrating the benefit of model-based approaches for controlling HAMs.

42 ENGINEERING↗

Telemetry Speeds Forest-Fire Control

Airborne system rapidly delivers hard copy to firefighters. Sensors in airplane send data to ground station for image processing. Imagery immediately transferred to U.S. Geologic Survey (USGS) maps by photo interpreter. Maps transmitted by telecopies directly to fire-control camps. Receipt by fire camp less than 10 minutes. Information aids in decisions involving deployment of firefighters and equipment, flood control, monitoring oilspills, observing thermal currents, and pollutions monitoring.

Arvesen, J. C.↗

Variable acuity remote viewing system flight demonstration

The Variable Acuity Remote Viewing System (VARVS), originally developed under contract to the Navy (ONR) as a laboratory brassboard, was modified for flight demonstration. The VARVS system was originally conceived as a technique which could circumvent the acuity/field of view/bandwidth tradeoffs that exists in remote viewing to provide a nearly eye limited display in both field of view (160 deg) and resolution (2 min arc) while utilizing conventional TV sensing, transmission, and display equipment. The modifications for flight demonstration consisted of modifying the sensor so it could be installed and flow in a Piper PA20 aircraft, equipped for remote control and modifying the display equipment so it could be integrated with the NASA Research RPB (RPRV) remote control cockpit.

Fisher, R. W.↗

An alternate method for achieving temperature control in the -130 C to 75 C range

Thermal vacuum testing often requires temperature control of chamber shrouds and heat exchangers within the -130 C to 75 C range. There are two conventional methods which are normally employed to achieve control through this intermediate temperature range: (1) single-pass flow where control is achieved by alternately pulsing hot gaseous nitrogen (GN2) and cold LN2 into the feed line to yield the setpoint temperature; and (2) closed-loop circulation where control is achieved by either electrically heating or LN2 cooling the circulating GN2 to yield the setpoint temperature. A third method, using a mass flow ratio controller along with modulating control valves on GN2 and LN2 lines, provides excellent control but equipment for this method is expensive and cost-prohibitive for all but long-term continuous processes. The single-pass method provides marginal control and can result in unexpected overcooling of the test article from even a short pulse of LN2. The closed-loop circulation method provides excellent control but requires an expensive blower capable of operating at elevated pressures and cryogenic temperatures. Where precise control is needed (plus or minus 2 C), single-pass flow systems typically have not provided the precision required, primarily because of overcooling temperature excursions. Where several individual circuits are to be controlled at different temperatures, the use of expensive cryogenic blowers for each circuit is also cost-prohibitive, especially for short duration of one-of-a-kind tests. At JPL, a variant of the single-pass method was developed that was shown to provide precise temperature control in the -130 C to 75 C range while exhibiting minimal setpoint overshoot during temperature transitions. This alternate method uses a commercially available temperature controller along with a GN2/LN2 mixer to dampen the amplitude of cold temperature spikes caused by LN2 pulsing. The design of the GN2/LN2 mixer, the overall control system configuration, the operational procedure, and the prototype system test results are described.

Johnson, Kenneth R.↗