Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

A reduced atmosphere for early Mars?

One-dimensional, radiative-convective climate calculations indicate that the old model of a warm, dense, CO2 atmosphere on early Mars is no longer viable. The magnitude of the greenhouse effect in a CO2/H2O atmosphere is limited by condensation of CO2 clouds; this phenomenon is not important for Mars today, but has a pronounced cooling effect at the low solar luminosities thought to apply during early solar system history. The failure of this model indicates one of four things: (1) the new climate calculations are incorrect; (2) current solar evolution models are incorrect; (3) the idea that early Mars was warm and wet is incorrect; or (4) the atmosphere of early Mars contained other greenhouse gases (or particles) in addition to CO2 and H2O. Of these explanations, the most plausible is number (4) and the rest of the investigation is a further explanation of number (4).

Kasting, J. F.↗

Effect of cloud cover and surface type on earth's radiation budget derived from the first year of ERBE data

One year of ERBE data is analyzed for variations in outgoing LW and absorbed solar flux. Differences in land and ocean radiation budgets as well as differences between clear-sky and total scenes, including clouds, are studied. The variation of monthly average radiative parameters is examined for February 1985 through January 1986 for selected study regions and on zonal and global scales. ERBE results show significant seasonal variations in both outgoing LW and absorbed SW flux, and a pronounced difference between oceanic and continental surfaces. The main factors determining cloud radiative forcing in a given region are solar insolation, cloud amount, cloud type, and surface properties. The strongest effects of clouds are found in the midlatitude storm tracks over the oceans. Over much of the globe, LW warming is balanced by SW cooling. The annual-global average net cloud forcing shows that clouds have a net cooling effect on the earth for the year.

Gibson, G. G.↗

Numerical solution for the temperature distribution in a cooled guide vane blade of a radial gas turbine

A two dimensional finite difference numerical technique is presented to determine the temperature distribution of an internal cooled blade of radial turbine guide vanes. A simple convection cooling is assumed inside the guide vane blade. Such cooling has relatively small cooling effectiveness at the leading edge and at the trailing edge. Heat transfer augmentation in these critical areas may be achieved by using impingement jets and film cooling. A computer program is written in FORTRAN IV for IBM 370/165 computer.

Hosny, W. M.↗

Computation of the temperature distribution in cooled radial inflow turbine guide vanes

A two-dimensional finite-difference numerical technique is presented to determine the temperature distribution of an internally-cooled blade of radial turbine guide vanes. A simple convection cooling is assumed inside the guide vane. Such an arrangement results in relatively small cooling effectiveness at the leading edge and at the trailing edge. Heat transfer augmentation in these critical areas may be achieved by using impingement jets and film cooling. A computer program is written in Fortran IV for IBM 370/165 computer.

Tabakoff, W.↗

Blade-to-coolant heat-transfer results and operating data from a natural-convection water-cooled single-stage turbine

Blade-to-coolant heat-transfer data and operating data were obtained with a natural-convection water-cooled turbine over range of turbine speeds and inlet-gas temperatures. The convective coefficients were correlated by the general relation for natural-convection heat transfer. The turbine data were displaced from a theoretical equation for natural convection heat transfer in the turbulent region and from natural-convection data obtained with vertical cylinders and plates; possible disruption of natural convection circulation within the blade coolant passages was thus indicated. Comparison of non dimensional temperature-ratio parameters for the blade leading edge, midchord, and trailing edge indicated that the blade cooling effectiveness is greatest at the midchord and least at the trailing edge.

COOLING - GAS TURBINE SYSTEMS↗

Summary of NASA aerodynamic and heat transfer studies in turbine vanes and blades

Aerodynamic effects of trailing edge geometry, hole size, angle, spacing, and shape were studied in two- and three-dimensional cascades and in a warm turbine test series. Heat transfer studies were carried out in various two- and three-dimensional test facilities in order to provide corresponding heat transfer data. Results are shown in terms of cooling effectiveness and aerodynamic efficiency for various coolant fractions, coolant-primary temperature ratios, and cooling configurations.

Moffitt, T. P.↗

Feasibility Study of Venus Surface Cooling Using Chemical Reactions with the Atmosphere

A literature search and theoretical analysis were conducted to investigate the feasibility of cooling a craft on Venus through chemical reformation of materials from the atmosphere. The core concept was to take carbon dioxide (CO2) from the Venus atmosphere and chemically reform it into simpler compounds such as carbon, oxygen, and carbon monoxide. This process is endothermic, taking energy from the surroundings to produce a cooling effect. A literature search was performed to document possible routes for achieving the desired reactions. Analyses indicated that on Venus, this concept could theoretically be used to produce cooling, but would not perform as well as a conventional heat pump. For environments other than Venus, the low theoretical performance limits general applicability of this concept, however this approach to cooling may be useful in niche applications. Analysis indicated that environments with particular atmospheric compositions and temperatures could allow a similar cooling system to operate with very good performance. This approach to cooling may also be useful where the products of reaction are also desirable, or for missions where design simplicity is valued. Conceptual designs for Venus cooling systems were developed using a modified concept, in which an expendable reactant supply would be used to promote more energetically favorable reactions with the ambient CO2, providing cooling for a more limited duration. This approach does not have the same performance issues, but the use of expendable supplies increases the mass requirements and limits the operating lifetime. This paper summarizes the findings of the literature search and corresponding analyses of the various cooling options.

Evans, Christopher↗

Feasibility Study of Venus Surfuce Cooling Using Chemical Reactions with the Atmosphere

A literature search and theoretical analysis were conducted to investigate the feasibility of cooling a craft on Venus through chemical reformation of materials from the atmosphere. The core concept was to take carbon dioxide (CO2) from the Venus atmosphere and chemically reform it into simpler compounds such as carbon, oxygen, and carbon monoxide. This process is endothermic, taking energy from the surroundings to produce a cooling effect. A literature search was performed to document possible routes for achieving the desired reactions. Analyses indicated that on Venus, this concept could theoretically be used to produce cooling, but would not perform as well as a conventional heat pump. For environments other than Venus, the low theoretical performance limits general applicability of this concept, however this approach to cooling may be useful in niche applications. Analysis indicated that environments with particular atmospheric compositions and temperatures could allow a similar cooling system to operate with very good performance. This approach to cooling may also be useful where the products of reaction are also desirable, or for missions where design simplicity is valued. Conceptual designs for Venus cooling systems were developed using a modified concept, in which an expendable reactant supply would be used to promote more energetically favorable reactions with the ambient CO2, providing cooling for a more limited duration. This approach does not have the same performance issues, but the use of expendable supplies increases the mass requirements and limits the operating lifetime. This paper summarizes the findings of the literature search and corresponding analyses of the various cooling options

Evans, Christopher↗

Summary of NASA aerodynamic and heat transfer studies in turbine vanes and blades

Aerodynamic effects of trailing edge geometry, hole size, angle, spacing, and shape have been studied in two- and three-dimensional cascades and in a warm turbine test series. Heat transfer studies have been carried out in various two- and three-dimensional test facilities in order to provide corresponding heat transfer data. Results are shown in terms of cooling effectiveness and aerodynamic efficiency for various coolant fractions, coolant-primary temperature ratios, and cooling configurations.

Moffitt, T. P.↗

Spatial Distribution of Aerosol Microphysical and Optical Properties and Direct Radiative Effect from the China Aerosol Remote Sensing Network

Multi-year observations of aerosol microphysical and optical properties, obtained through ground-based remote sensing at 50 China Aerosol Remote Sensing Network (CARSNET) sites, were used to characterize the aerosol climatology for representative remote, rural, and urban areas over China to assess effects on climate. The annual mean effective radii for total particles (ReffT) decreased from north to south and from rural to urban sites, and high total particle volumes were found at the urban sites. The aerosol optical depth at 440 nm (AOD440 nm) increased from remote and rural sites (0.12) to urban sites (0.79), and the extinction Ångström exponent (EAE440–870 nm) increased from 0.71 at the arid and semi-arid sites to 1.15 at the urban sites, presumably due to anthropogenic emissions. Single-scattering albedo (SSA440 nm) ranged from 0.88 to 0.92, indicating slightly to strongly absorbing aerosols. Absorption AOD440 nm values were 0.01 at the remote sites versus 0.07 at the urban sites. The average direct aerosol radiative effect (DARE) at the bottom of atmosphere increased from the sites in the remote areas (−24.40 W m−2) to the urban areas (−103.28 W m−2), indicating increased cooling at the latter. The DARE for the top of the atmosphere increased from −4.79 W m−2 at the remote sites to −30.05 W m−2 at the urban sites, indicating overall cooling effects for the Earth–atmosphere system. A classification method based on SSA440 nm, fine-mode fraction (FMF), and EAE440–870 nm showed that coarse-mode particles (mainly dust) were dominant at the rural sites near the northwestern deserts, while light-absorbing, fine-mode particles were important at most urban sites. This study will be important for understanding aerosol climate effects and regional environmental pollution, and the results will provide useful information for satellite validation and the improvement of climate modelling.

Huizheng Che↗

Estimation of Aerosol Direct Radiative Effects from Satellite and In Situ Measurements

Ames researchers have combined measurements from satellite, aircraft, and the surface to estimate the effect of airborne particles (aerosols) on the solar radiation over the North Atlantic region. These aerosols (which come from both natural and pollution sources) can reflect solar radiation, causing a cooling effect that opposes the warming caused by carbon dioxide. Recently, increased attention has been paid to aerosol effects to better understand the Earth climate system.

Bergstrom, Robert W.↗

Saharan dust effects on North Atlantic sea surface skin Temperatures

Saharan dust outbreaks frequently propagate westward over the Atlantic Ocean; accurate quantification of the dust aerosol scattering and absorption effect on the surface radiative fluxes (SRF) is fundamental to understanding critical climate feedbacks. By exploiting large sets of measurements from many ship campaigns in conjunction with reanalysis products, this study characterizes the sensitivity of the SRF and skin Sea‐Surface Temperature (SSTskin) to the Saharan dust aerosols using models of the atmospheric radiative transfer and thermal skin effect. Saharan dust outbreaks can decrease the surface shortwave radiation up to 190 W/sq.m, and an analysis of the corresponding SST(skin) changes using a thermal skin model suggests dust‐induced cooling effects as large as −0.24 K during daytime and a warming effect of up of 0.06 K during daytime and nighttime respectively. Greater physical insight into the radiative transfer through an aerosol‐burdened atmosphere will substantially improve the predictive capabilities of weather and climate studies on a regional basis.

Saharan Dust↗

Total Volcanic Stratospheric Aerosol Optical Depths and Implications for Global Climate Change

Understanding the cooling effect of recent volcanoes is of particular interest in the context of the post-2000 slowing of the rate of global warming. Satellite observations of aerosol optical depth above 15 km have demonstrated that small-magnitude volcanic eruptions substantially perturb incoming solar radiation. Here we use lidar, Aerosol Robotic Network, and balloon-borne observations to provide evidence that currently available satellite databases neglect substantial amounts of volcanic aerosol between the tropopause and 15 km at middle to high latitudes and therefore underestimate total radiative forcing resulting from the recent eruptions. Incorporating these estimates into a simple climate model, we determine the global volcanic aerosol forcing since 2000 to be 0.19 +/- 0.09W/sq m. This translates into an estimated global cooling of 0.05 to 0.12 C. We conclude that recent volcanic events are responsible for more post-2000 cooling than is implied by satellite databases that neglect volcanic aerosol effects below 15 km.

aerosols↗

Multilayer composite material and method for evaporative cooling

A multilayer composite material and method for evaporative cooling of a person employs an evaporative cooling liquid that changes phase from a liquid to a gaseous state to absorb thermal energy. The evaporative cooling liquid is absorbed into a superabsorbent material enclosed within the multilayer composite material. The multilayer composite material has a high percentage of the evaporative cooling liquid in the matrix. The cooling effect can be sustained for an extended period of time because of the high percentage of phase change liquid that can be absorbed into the superabsorbent. Such a composite can be used for cooling febrile patients by evaporative cooling as the evaporative cooling liquid in the matrix changes from a liquid to a gaseous state to absorb thermal energy. The composite can be made with a perforated barrier material around the outside to regulate the evaporation rate of the phase change liquid. Alternatively, the composite can be made with an imperveous barrier material or semipermeable membrane on one side to prevent the liquid from contacting the person's skin. The evaporative cooling liquid in the matrix can be recharged by soaking the material in the liquid. The multilayer composite material can be fashioned into blankets, garments and other articles.

Buckley, Theresa M.↗

One-dimensional outgassing problem

A predominantly numerical study, using the direct-simulation Monte Carlo method, of the flow from outgassing surfaces with plane, cylindrical, or spherical geometry is presented. The numerical results for the plane flow case are compared with existing theoretical and experimental results and also with a new formulation of the jump conditions across the Knudsen layer between the surface and the continuum outflow. This outflow is sonic for the free expansion case but subsonic in the presence of back-pressure effects. The self-scattered return flux is 19% of the outgassed flux in the sonic outflow case and increases at lower Mach numbers. Thermal accomodation and reflection of this return flux produces an outgassing cooling effect. The cylindrical and spherical geometries introduce an additional Knudsen number defined by the ratio of the mean free path in the effusing gas to the radius. The plane flow results apply when this Knudsen number is less than 0.001 and, when it is of order unity or above, the return flux is inversely proportional to it.

Tran Cong, T.↗

Multitemperature Cryogenic Radiative Cooler

Multiple radiator stages separated by V-groove shields protect main cooler from parasitic heat radiation and offer usable cooling themselves. Proposed cryogenic radiative cooler achieves lower temperatures previously possible with passive radiators in space. Provides useful cooling power at several temperatures instead of one. Cold-radiator stage protected by multiple shield assemblies intercepting radiation heat leaks from warmer supporting structure and redirects it out to space. Each shield assembly has effective cooling capacity enabling it to cool optical filter.

Bard, Steven↗