Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Servicing operations for the SIRTF Observatory at the Space Station

This paper describes the servicing requirements, plans, and proposed Space Station-based servicing operations for the Space Infrared Telescope Facility (SIRTF) Observatory. SIRTF is a cryogenically-cooled, long-life, one meter class space telescope which will be operated by NASA as a free-flying observatory for infrared astronomy, in the mid-1990's. To achieve its 5-year lifetime requirement (10 year goal), SIRTF must be replenished periodically with cryogenic helium and have its life-limited modular subsystems replaced; capability for contingency repair of warm components will also be provided in the Observatory design. A general description of the SIRTF Observatory is given, including options for the support systems (spacecraft). The overall servicing philosophy and plans are addressed with scheduling and needed support elements described. A proposed Space Station-based servicing scenario is described, including orbital transfer, servicing and checkout operations. A detailed description and timeline for liquid helium replenishment operations is provided, including a conceptual design and technology development program for the cryogenic helium transfer dewar (tanker). Finally, a preliminary SIRTF spares/logistics philosophy is outlined, including tradeoffs to be considered.

Wiltsee, Christopher B.↗

Execution of the Spitzer In-orbit Checkout and Science Verification Plan

The Spitzer Space Telescope is an 85-cm telescope with three cryogenically cooled instruments. Following launch, the observatory was initialized and commissioned for science operations during the in-orbit checkout (IOC) and science verification (SV) phases, carried out over a total of 98.3 days. The execution of the IOC/SV mission plan progressively established Spitzer capabilities taking into consideration thermal, cryogenic, optical, pointing, communications, and operational designs and constraints. The plan was carried out with high efficiency, making effective use of cryogen-limited flight time. One key component to the success of the plan was the pre-launch allocation of schedule reserve in the timeline of IOC/SV activities, and how it was used in flight both to cover activity redesign and growth due to continually improving spacecraft and instrument knowledge, and to recover from anomalies. This paper describes the adaptive system design and evolution, implementation, and lessons learned from IOC/SV operations. It is hoped that this information will provide guidance to future missions with similar engineering challenges

operations↗

A large cooled infrared telescope facility for Spacelab

An optimized cooled IR telescope of 1 m aperture diameter will offer sensitivities over the 1 micron to 1 mm spectrum at least 1000 times greater than can be achieved from the ground in the atmospheric windows, and comparable sensitivities at wavelengths that are outside the windows. A study has shown that a cryogenically-cooled telescope of up to 1.6 m aperture diameter for Spacelab is feasible without new technology, although some development of detectors and scientific instruments to take advantage of the extreme sensitivity is indicated.-

Mccarthy, S. G.↗

Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost

A control valve that can throttle high-pressure cryogenic fluid embodies several design features that distinguish it over conventional valves designed for similar applications. Field and design engineers worked together to create a valve that would simplify installation, trim changes, and maintenance, thus reducing overall cost. The seals and plug stem packing were designed to perform optimally in cryogenic temperature ranges. Unlike conventional high-pressure cryogenic valves, the trim size can be changed independent of the body. The design feature that provides flexibility for changing the trim is a split body. The body is divided into an upper and a lower section with the seat ring sandwiched in between. In order to maintain the plug stem packing at an acceptable sealing temperature during cryogenic service, heat-exchanging fins were added to the upper body section. The body is made of stainless steel. The seat ring is made of a nickel-based alloy having a coefficient of thermal expansion less than that of the body material. Consequently, when the interior of the valve is cooled cryogenically, the body surrounding the seat ring contracts more than the seat ring. This feature prevents external leakage at the body-seat joint. The seat ring has been machined to have small, raised-face sealing surfaces on both sides of the seal groove. These sealing surfaces concentrate the body bolt load over a small area, thereby preventing external leakage. The design of the body bolt circle is different from that of conventional highpressure control valves. Half of the bolts clamp the split body together from the top, and half from the bottom side. This bolt-circle design allows a short, clean flow path, which minimizes frictional flow losses. This bolt-circle design also makes it possible to shorten the face-toface length of the valve, which is 25.5 in. (65 cm). In contrast, a conventional, high-pressure control valve face-to-face dimension may be greater than 40 in. (>1 m) long.

Source record↗

Formation of niobium hydride precipitates in superconducting qubits

We report evidence for the formation of niobium hydride phase within niobium films on silicon substrates in superconducting qubits fabricated at Rigetti Computing. For this study, we combined complementary techniques—including room-temperature and cryogenic atomic force microscopy (AFM), synchrotron x-ray diffraction, and time-of-flight secondary ion mass spectroscopy (ToF-SIMS)—to directly reveal the existence of niobium hydride precipitates on the surface of superconducting qubits. Upon cryogenic cooling, we observed variation in the size and morphology of the hydrides, ranging from small (∼5 nm) irregular shapes to large (∼10–100 nm) domains within the Nb grains, which were fully converted to niobium hydrides. Since niobium hydrides are nonsuperconducting and can easily change in size and location upon different cooldowns to cryogenic temperature, our finding highlights a previously unknown source of decoherence in superconducting qubits. This contributes to quasiparticle losses, offering a potential explanation for changes in qubit performance upon cooldowns. Finally, by leveraging the RF performance of a 3D bulk Nb resonator, we quantify RF dissipation in a superconducting qubit caused by hydrogen concentration variation, and propose a practical engineering pathway to mitigate the formation of Nb hydrides for superconducting qubit applications.

Sung, Zuhawn [Fermi National Accelerator Laborator↗

Mission optimization of the Space Infrared Telescope Facility

The Space Infrared Telescope Facility (SIRTF) mission based on a cryogenically cooled telescope is described. The SIRTF makes it possible to perform background limited measurements with three focal plane instruments in the wavelength range 2-700 microns over the entire celestial sphere for at least five years. A telescope performance limited by the natural astrophysical background between 2 to 300 microns is achieved by using a superfluid helium cryogenic system for maintaining the forebaffle temperature below 8 K. The attitude control system based on Extreme Ultra-Violet Explorer reaction wheels meets the large and small angle slew requirements and provides 0.15 arc sec pointing stability. The present HEO baseline configuration has a mass of 4370 kg. The future Titan IV/Centaur launch capability to 100,000 km for a SIRTF-sized payload is at least 5770 kg.

Brooks, Walter F.↗

Gamma-Ray Pulse Tube Cooler Development and Testing

For a variety of space-science applications, such as gamma-ray spectroscopy, the introduction of cryogenic cooling via a cryocooler can greatly increase the potential science return by allowing the use of more sensitive and lower noise detectors.

gamma-ray cryogenic cryocooler pulse tube↗

Cryogenic, low-noise high electron mobility transistor amplifiers for the Deep Space Network

The rapid advances recently achieved by cryogenically cooled high electron mobility transistor (HEMT) low-noise amplifiers (LNA's) in the 1- to 10-GHz range are making them extremely competitive with maser amplifiers. In order to address future spacecraft navigation, telemetry, radar, and radio science needs, the Deep Space Network is investing both maser and HEMT amplifiers for its Ka-band (32-GHz) downlink capability. This article describes the current state cryogenic HEMT LNA development at Ka-band for the DSN. Noise performance results at S-band (2.3 GHz) and X-band (8.5 GHz) for HEMT's and masers are included for completeness.

Bautista, J. J.↗

In-Situ Calibrated Modeling of Residual Stresses Induced in Machining under Various Cooling and Lubricating Environments

Although many functional characteristics, such as fatigue life and damage resistance depend on residual stresses, there are currently no industrially viable ‘Digital Process Twin’ models (DPTs) capable of efficiently and quickly predicting machining-induced stresses. By leveraging advances in ultra-high-speed in-situ experimental characterization of machining and finishing processes under plane strain (orthogonal/2D) conditions, we have developed a set of physics-based semi-analytical models to predict residual stress evolution in light of the extreme gradients of stress, strain and temperature, which are unique to these thermo-mechanical processes. Initial validation trials of this novel paradigm were carried out in Ti-6Al4V and AISI 4340 alloy steel. A variety dry, cryogenically cooled and oil lubricated conditions were evaluated to determine the model’s ability to capture the tribological changes induced due to lubrication and cooling. The preliminarily calibrated and validated model exhibited an average correlation of better than 20% between the predicted stresses and experimental data, with calculation times of less than a second. Based on such fast-acting DPTs, the authors envision future capabilities in pro-active surface engineering of advanced structural components (e.g., turbine blades).

36 MATERIALS SCIENCE↗

Development and Testing of Cooled CMCs for High Thermal Flux Applications

Ceramic Matrix Composites (CMCS) offer the potential for significant weight savings and improved performance for a range of propulsion components utilizing refractory materials. This paper describes the fabrication and testing of functionally graded CMCs produced via a low cost process that represents an order of magnitude cost savings over conventionally fabricated CMCS. Test cylinders were fabricated, characterized and evaluated during exposure to high thermal fluxes of up to 10MW/meters squared at the Laser Hardened Materials Evaluation Laboratory (LHMEL). The bulk density of the CMC tubes was approximately 2.2 grams per cubic centimeters. The performance of cryogenically cooled CMCs was compared with uncooled CMCs against similar thermal loads, and fundamental property data collected for this relatively new breed of CMC. Finally, test thrust cells were fabricated from the functionally graded composite and tested using liquid H2 and O2 propellants at NASA Glen.

Patterson , Mark↗

RECORD FAST CYCLING ACCELERATOR MAGNET BASED ON HIGH TEMPERATURE SUPERCONDUCTOR

We report on the High Temperature Superconductor (HTS) based prototype accelerator magnet capable to operate at 12 T/s B-field ramping rate with a very low supporting cryogenic cooling power thus indicating a feasibility of its application in the accelerator requiring high repetition rate and high average beam power. The magnet is designed to simultaneously accelerate two particle beams in the separate beam gaps energized by a single conductor. The design, construction and the power test of the prototype fast-cycling HTS based accelerator magnet is presented while the more detailed description and power test data analysis s given in [1]. As example, the measured cryogenic power loss limit is discussed in terms of the feasibility of application of such a magnet for the construction of the 8 GeV dual proton beam Booster.

43 PARTICLE ACCELERATORS↗

SIRTF - The Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope (SIRTF) is a 1-m class cryogenically cooled telescope to be operated from the shuttle as a facility for infrared astronomy. By exploiting the very low infrared background of space, SIRTF will achieve 100 to 1000 times the sensitivity currently attainable at infrared wavelengths between 2 and 200 microns. The scientific requirements of SIRTF, the current design concept, and the scientific capabilities of the systems are reviewed. We also review recent experimental results showing that mirrors made of glassy materials may be suitable for use in large cryogenic telescopes such as SIRTF.

Werner, M. W.↗

SIRTF - The Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope (SIRTF) is a 1-m class cryogenically cooled telescope to be operated from the Shuttle as a facility for infrared astronomy. By exploiting the very low infrared background of space, SIRTF will achieve 100 to 1000 times the sensitivity currently attainable at infrared wavelengths between 2 and 200 microns. The scientific requirements of SIRTF, the current design concept, and the scientific capabilities of the systems are reviewed. Recent experimental results are also reviewed showing that mirrors made of glassy materials may be suitable for use in large cryogenic telescopes such as SIRTF. Previously announced in STAR as N82-32207

Werner, M. W.↗

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler↗

Overview of measurements from the infrared telescope on Spacelab 2

A small helium cooled IR telescope flown on Spacelab-2 in July/August 1985 was used to make infrared measurements between 2 microns and 120 microns. New data were obtained on the structure of the Galaxy at 2 microns and 7 microns showing it to be much broader at these wavelengths than at longer wavelengths. The IR emission due to contamination from the Shuttle was found to be greater than anticipated, indicating the induced environment to be much higher than the planned limits. Aspects of superfluid helium management in zero-G and of a cryogenically cooled telescope design were also tested.

Koch, D. G.↗

Cryogenic Low Noise MMIC Amplifiers for U-Band (40-60 GHz)

In this work, we describe monolithic millimeter-wave integrated circuit (MMIC) Low Noise Amplifier (LNA) and mixer designs for U-Band, also known as the WR19 waveguide band (40-60 GHz). The LNAs were fabricated in NGC’s 35 nm InP HEMT MMIC process. The MMICs were packaged in WR19 waveguide housings and tested for noise, both at room temperature and cryogenically. We present the results, including a comparison to the state-of-the-art, and discuss applications for amplifiers in this frequency range. To date, these are the first cryogenic 35 nm InP MMIC results covering the 40-60 GHz range. We achieved a noise temperature less than 30 K over the 40-60 GHz range, when the amplifiers were cryogenically cooled. These results are comparable with other results in the literature, and we believe are the lowest reported for MMICs in the 50-60 GHz range.

MMIC↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗