At least 199 records · Page 11

Shuttle cryogenic supply system optimization study. Volume 1: Management supply, sections 1 - 3

An analysis of the cryogenic supply system for use on space shuttle vehicles was conducted. The major outputs of the analysis are: (1) evaluations of subsystem and integrated system concepts, (2) selection of representative designs, (3) parametric data and sensitivity studies, (4) evaluation of cryogenic cooling in environmental control subsystems, and (5) development of mathematical model.

Source record↗

Cryogenic applications for environment simulation.

Some of the applications of cryogenics for simulating space environmental conditions are reviewed, and typical existing space simulation facilities are described. The techniques of adapting cryogenics to environmental simulation are discussed. Special attention is given to cryosorption pumps designed to accelerate cryogenic cooling of the adsorbent material.

Hardgrove, W. F.↗

Infrared telescopes for a space observatory

A cryogenically cooled infrared telescope of 1 to 2 meter aperture is discussed. Advantages of the space environment are detailed, and design considerations for cooled telescopes are given, leading to a schematic and preliminary design of a telescope for the space shuttle. The advantages of the sortie mode to an infrared observatory are dealt with and possible use of an ambient temperature telescope is discussed. Costs of infrared telescope observation are indicated.

Witteborn, F. S.↗

An S-band radiometer design with high absolute precision

A radiometer for the remote measurement of sea surface temperature is described. The development of an instrument capable not only of high relative accuracy (i.e., resolution) but also of high absolute precision is considered. The concepts underlying the design of an instrument capable of an absolute accuracy of a few tenths degrees Kelvin in the measurement of brightness temperature at S band are described. The role of the antenna is discussed, and the importance of high ohmic and beam efficiencies is stressed. The hardware itself is fully described, along with an outline concerning the design of a unique cryogenically cooled termination used to calibrate the whole radiometer, including antenna. Finally, some test results are presented that show that the design goals for the instrument have been closely approached.

Hardy, W. N.↗

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗

Low-noise room-temperature and cryogenic mixers for 80-120 GHz

A description is given of two new mixers designed to operate in the 80-120-GHz range on 36-ft radio telescope. It is shown that for a hard-driven diode the parasitic resistance and capacitance are the primary factors influencing the design of the diode mount. A room-temperature mixer is described which achieves a single-sideband (SSB) conversion loss (L) of 5.5 dB, and a SSB noise temperature (Tm) of 500 K (excluding the IF contribution) with a 1.4-GHz IF. A cryogenically cooled version, using a quartz structure to support the diode chip and contact whisker, achieves values of L = 5.8 dB and Tm = 300 K with a 4.75-GHz IF. The mixers use high-quality Schottky-barrier diodes in a one-quarter-height waveguide mount.

Kerr, A. R.↗

A radiometer for monitoring column densities of infrared-active molecules

A cryogenically cooled radiometer capable of accurately measuring the infrared background from 3.5 to 100 microns and the column density of water vapor for the low values specified for the space shuttle orbiter is described. The infrared spectral characteristics of the contaminant atmosphere are considered as well as the spectral characteristics of the natural IR background. The measurement technique is described in detail.

Witteborn, F. C.↗

Obtaining ultradry crystalline solids

Drying, cryogenic cooling, and redrying with high temperature and vacuum techniques, reduces moisture in crystalline solids to less than 0.01%.

Attar, A.↗

Atmosphere, Magnetosphere and Plasmas in Space (AMPS). Spacelab payload definition study. Volume 7, book 3: Supporting Research and Technology (SR and T) report

The items identified as required to support the AMPS mission and requiring SR and T support and further work are: (1) a general purpose Experiment Pointing Mount; (2) a technique for measuring the attitude of the pallet-mounted or deployed experiments; (3) the development of a common optics cryogenically cooled interferometer spectrometer; (4) the development of a differential absorption lidar system for the measurement of ozone densitites in the earth's atmosphere; (5) the development of dc to dc power processors which are capable of converting energy stored in a capacitor system at 500 V to energy supplied to equipment operating at 40 kV and at 20 kW (eventually up to 100 kW); and (6) the development of a magnetic or possibly electrostatic deflection system capable of bending the beam of an electron accelerator. A data sheet is included for each item, briefly describing the background and need for each item, and the general objectives of the required development, and identifying the schedule requirements in support of the AMPS program.

Source record↗

Development, applications, and future of infrared upconversion

Infrared upconversion is a technique that converts linearly polarized infrared photons to photons of higher frequency. The technique can be applied advantageously to the detection of IR radiation because the upconverted signal can be detected by photon-counting devices available for the visible spectral region. In addition, unlike presently available IR detectors, an upconversion device can provide sensitivity to IR radiation without the need for cryogenic cooling. Infrared upconversion was first demonstrated in 1961. By 1974, approximately 100% quantum conversion efficiency and a bandwidth of 1.81 microns had been attained. Photometric detection of IR radiation from various astronomical objects had also been demonstrated. Research is presently under way on the application of upconversion to astronomical spectroscopy and to imaging. The major drawback to the upconversion technique is the sheer bulk of the apparatus involved. It is anticipated that this problem can be overcome by applying the developing technology of integrated optics.

Gurski, T. R.↗

Photovoltaic, gravitationally-stabilized solid-state, satellite solar power station /GSS4PS/

The salient feature of a gravitationally-stabilized satellite solar power system (SSPS) for a photovoltaic system is that the large solar array is separated into smaller segments or subunits, joined together in a linear array oriented along the local vertical. Applicability of gravitational stabilization to the design of photovoltaic SSPS is demonstrated. Both actively controlled systems using multiple solar panels oriented to the sun and passively controlled systems requiring no sun orientation are considered and determined to be feasible. Expressions for gravity-gradient induced tension and restoring torques about the local vertical are assessed. Particular attention is directed to the applicability of solid-state approaches to the design of SSPS. It is shown that an all solid-state SSPS utilizing the LITOMIC (light-to-microwave conversion) concept is feasible but that a hybrid system employing a combination of both solid-state and cryogenic cooled low-voltage techniques to the design of the power management and distribution subsystem may also provide a solution.

Cantafio, L. J.↗

Results from the Air Force Geophysics Laboratory survey catalog

Results of an IR survey program designed to obtain the spatial and brightness distributions of a representative sample of IR-emitting objects in the 3-30 micron range are analyzed. Small cryogenically cooled telescopes carried above the atmosphere on sounding rockets were employed in the research. Minimization of sky noise and photon background, experimental equipment, and data reduction techniques are discussed.

Price, S. D.↗

Survey report on the state-of-the-art of cryogenic thermometry and signal conditioners and their potential for standardized space hardware

The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle Payloads was investigated. These payloads operate from .3 Kelvin to 300 Kelvin. Standard detectors were selected and matching signal conditioning equipment were specified. This equipment will operate in a spacecraft environment and be compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical earth orbiting spacecraft. Work statements to better define and advance detector performance are presented.

Source record↗

The Goddard Space Flight Center Solid State Spectrometer for the HEAO-B Mission

A non-dispersive, cryogenically-cooled X-ray detector system, to be flown as one of the focal-plane experiments on the High Energy Astrophysical Observatory-B, is described. The instrument is designed to measure the X-ray flux in the 500 eV to 5000 eV range with an energy resolution of 150 eV (pulser) and a temporal resolution approaching 2 microsec.

Joyce, R. M.↗

Infrared astronomical satellite

Design and mission characteristics of the Infrared Astronomical Satellite (IRAS) are reviewed with attention to the satellite/telescope configuration. The IRAS will be launched into a 900 km near-polar orbit (inclination 99 deg), with a cryogenically cooled 60 cm telescope capable of collecting 700 million bits of data per day. The telescope is expected to add from 6000 to one million new IR sources to the astronomical catalogs. Objects for study include stars, extended sources, asteroids, zodiacal light, artificial satellites, high energy protons, and dust.

Mclaughlin, W. I.↗

High-resolution spectrometer

Proposed spectrometer combines optical and imaging devices and cryogenic cooling to measure infrared radiation in 1-to-15 micrometer wavelength range with spatial resolution of 1 arc-second and average spectral resolution of about 0.1 cm(-1). Compact, lightweight unit is suitable for laboratory or field use. Pollution monitoring is possible application.

Beer, R.↗

OAST Space Theme Workshop. Volume 3: Working group summary. 7: Material (M-1). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2)

The approach of matching technology areas with various themes needs was not effective for the materials and thermal control discipline because of the diversity of requirements for each. Top priorities were evolved from the advanced space transportation system and the space power platform because these are essential building blocks in fulfilling some of the other themes. Important needs identified include life long-life cryogenic cooling systems for sensors, masers, and other devices and the needs for lightweight nuclear shielding materials for nuclear electric propulsion.

Source record↗

Low-noise receivers: S-band parametric up converter development

The combination of a cryogenically-cooled parametric upconverter and a higher frequency maser post amplifier was proposed as a method of achieving maser-like receiver noise temperatures over much larger instantaneous bandwidths and tuning ranges than are presently obtainable with masers in the range of 1 to 18 GHz. An experimental 2.0- to 2.5-GHz parametric upconverter/maser system was developed to explore these possibilities. Initial tests of this system resulted in an effective input noise temperature of 3.1 K at 2295 MHz and 3.2 K at 2388 MHz. The parametric upconverter logged over 1500 hours at 4.5 K and underwent 5 thermal cycles (300 K to 4.5 K to 300 K) without degradation.

Petty, S.↗