Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Probing the impact of oxygen negative ions on the self-organized pattern in 1 atm DC glow with liquid anode

In an atmospheric DC glow discharge with a liquid anode, the plasma anode glow attached to the grounded liquid surface under certain conditions self-organizes into coherent patterns. Optical emission spectroscopy revealed that the emission consists primarily of the second positive system of nitrogen, N 2 (C-B), whose excitation energy is low and sensitive to changes in the electron energy distribution. In addition to electrons, negative ions can accumulate in the anode sheath and affect the local space charge. It has been speculated that these negative ions play a role in pattern formation at the anode surface. In this work, the role of oxygen negative ions was explored. It was found that the formation of anode patterns requires at least a 7% volume fraction of oxygen in the ambient gas. Results showed that O 2 - is the dominant negative ion species in atmospheric DC glow discharge, with a density of ~10 12 cm -3 . While the presence of oxygen appears to be crucial for pattern formation, this study indicated that patterns still formed without geometric changes even when 62% of negative ions in the plasma were detached by a laser. This suggests that negative ions do not support the patterns, while oxygen's heating effect may induce instability at the anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface deformation coupled with self-organized pattern on a liquid anode of 1 atm DC glow discharge

Intricate, self-organized plasma structures observed above the surface of a liquid anode of atmospheric DC glow discharge were found to give rise to coherent, organized surface deformation and mechanical wave formation at the plasma–liquid interface. This new phenomenon indicates that the liquid is closely coupled to the plasma by the anode sheath’s electrohydrodynamic (EHD) force. A scientific question then arises: Do surface perturbations, coupled with the nonuniform surface charge distribution, enhance the electric field and induce self-organization? Using the reflective background-oriented schlieren technique, the liquid surface profile under the plasma pattern was measured for the first time. The results show that surface distortions are driven by the repulsive Coulomb force of nonuniform net-negative surface charge acted by the anode sheath field. The impacts of various operating parameters on the patterns and surface waves were examined, revealing the significance of gas heating and liquid charge relaxation time in the pattern formation mechanism. Time-resolved dynamics of a pulsed DC discharge indicated that the surface deformation only appeared after the establishment of plasma patterns. Statistically, the surface wave under the plasma has high wave numbers (8000–16000 m −1 ) and small amplitudes ($<$ 10 µm), generally found in the capillary wave regime. Yet the motion of surface deformations is in tandem with the plasma pattern and exhibits a nondispersive nature of constant phase velocity (0.1–0.4 m s −1 ), suggesting the dominant role of EHD force over the surface tension in the observed surface wave. These results indicate that the deformed liquid surface is driven by the EHD force of the plasma sheath. Although they share a similar geometry, the deformation and wave dynamics of the liquid surface do not stimulate a plasma pattern. Importantly, the complex EHD coupling in the plasma–liquid system raises awareness and new challenges for plasma control engineering, and the quantitative characteristics of the nondispersive surface wave are informative for advancing relevant theory and modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards understanding the magnetic properties of the breathing pyrochlore compound Ba3Yb2Zn5O11through single-crystal studies

Abstract Ba 3 Yb 2 Zn 5 O 11 is exceptional among breathing pyrochlore compounds for being in the nearly-decoupled limit where inter-tetrahedron interactions are weak, hosting isolated clusters or molecular magnet-like tetrahedra of magnetic ytterbium (Yb 3+ ) ions. In this work, we present the study carried out on single-crystal samples of the breathing pyrochlore Ba 3 Yb 2 Zn 5 O 11 , using a variety of magnetometry and neutron scattering techniques along with theoretical modeling. We employ inelastic neutron scattering to investigate the magnetic dynamics as a function of applied field (with respect to both magnitude and direction) down to a temperature of 70 mK, where inelastic scattering reveals dispersionless bands of excitations as found in earlier powder sample studies, in good agreement with a single-tetrahedron model. However, diffuse neutron scattering at zero field and dc-susceptibility at finite field exhibit features suggesting the presence of excitations at low-energy that are not captured by the single tetrahedron model. Analysis of the local structure down to 2 K via pair distribution function analysis finds no evidence of structural disorder. We conclude that effects beyond the single tetrahedron model are important in describing the low-energy, low-temperature physics of Ba 3 Yb 2 Zn 5 O 11 , but their nature remains undetermined.

36 MATERIALS SCIENCE↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simultaneous single-shot rotation–vibration non-equilibrium thermometry using pure rotational fs/ps CARS coherence beating

Here, we report the development of a simple and sensitive two-beam hybrid femtosecond/picosecond pure rotational coherent anti-Stokes Raman scattering (fs/ps CARS) method to simultaneously measure the rotational and vibrational temperatures of diatomic molecules. Rotation–vibration non-equilibrium plays a key role in the chemistry and thermalization in low-temperature plasmas as well as thermal loading of hypersonic vehicles. This approach uses time-domain interferences between ground state and vibrationally excited N 2 molecules to intentionally induce coherence beating that leads to apparent non-Boltzmann distributions in the pure rotational spectra. These distortions enable simultaneous inference of both the rotational and vibrational temperatures. Coherence beating effects were observed in single-shot fs/ps CARS measurements of a 75 Torr N 2 DC glow discharge and were successfully modeled for rotational and vibrational temperature extraction. We show that this method can be more sensitive than a pure rotational fs/ps CARS approach using a spectrally narrow probe pulse. Lastly, we experimentally measured the beat frequencies via Fourier transform of the time-domain response and obtained excellent agreement with the model.

42 ENGINEERING↗

PV Inverter Systems Enabled by Monolithically Integrated SiC based Four Quadrant Power Switch (4-QPS) [BiDFET]

The purpose of this project was to develop a new breed of Power Conversion Systems (PCS) for PV integration that is enabled by the newly developed 4-Quadrant Single Die SiC Power Semiconductor Switches (4-QPS) or also referred to as “Bidirectional FET (BIDFET)”. This work includes semiconductor die development, advanced packaging, converter design, development, and testing of 4-QPS enabled hardware prototypes at 1 kW (for single phase residential application) and 10 kW (for three phase commercial application). The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four-quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs, and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. The matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac–ac and ac–dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-𝑥 gluon GPD constrained from deeply virtual 𝐽/𝜓 production and gluon PDF through universal-moment parametrization

We phenomenologically constrain the small-𝑥 and small-𝜉 gluon generalized parton distributions (GPDs) with the deeply virtual 𝐽/𝜓 production (DV⁢𝐽/𝜓⁢P) in the framework of GPDs through universal moment parameterization (GUMP). We use a hybrid cross-section formula combining collinear factorization to the next-to-leading order (NLO) accuracy of the strong coupling 𝛼 𝑠 , with corrections from nonrelativistic QCD to account for the power corrections due to the heavy 𝐽/𝜓 mass. We reach reasonable fit to the measured differential cross sections of DV⁢𝐽/𝜓⁢P by H1 at the Hadron-Electron Ring Accelerator as well as forward gluon parton distribution functions (PDFs) from JAM22 global analysis. We find that both NLO and nonrelativistic corrections are significant for heavy vector meson productions. Of course, the gluon GPD we obtain still contains considerable freedom in need of inputs from other constraints, particularly in the distribution-amplitude-like region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Wireless power system

A system and method are provided for a feed-forward control of an inverter to reduce, and potentially minimize, a DC link capacitor of a wireless power transfer system. The feed-forward control may be utilized to reduce the capacitance of the DC link capacitor in a single-phase series-series compensated WPT system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Traction Inverter Integrated On-Board DC Fast Charging through Partial Power Processing

This paper introduces an innovative on-board integrated DC charging approach through partial power processing (PPP) in a traction inverter system. The proposed system, incorporating a series-connected partial power dual-active-bridge (DAB) converter, efficiently regulates the DC link voltage to achieve an optimal bus voltage for traction operation across a wide speed and torque range. Leveraging partial and bidirectional power processing, the battery current during charging is precisely regulated without the need for external DC-DC charging equipment, ensuring seamless integration to a DC hub with different voltage levels. This advanced integration also endows the system with bidirectional power exchange capability to/from the external DC hub, i.e., vehicle-to-DC (V2DC).

DAB↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

Modeling of convective cells, turbulence, and transport induced by a radio-frequency antenna in the tokamak boundary plasma

The edge turbulence model Hermes (Dudson et al 2017 Plasma Phys. Control. Fusion 59 05401) is set up for plasma boundary simulations with an radiofrequency (RF) antenna, using parameters characteristic of a tokamak edge. Cartesian slab geometry is used with thin plate limiters representing the ion cyclotron range of frequency (ICRF) antenna side-wall limiters. Ad-hoc DC electric biasing of the limiters, motivated by calculations with VSim (Nieter et al 2004 J. Comput. Phys. 196 448), represents an induced RF sheath rectified potential in the plasma turbulence model. Flux-driven turbulence simulations demonstrate a realistic distribution of plasma profiles and fluctuations. There is a clear effect of the antenna sheath voltage leading to formation of convective cells; bias-induced convective transport flattens the scrape-off layer density profile and fluctuations penetrate into the shadow region of the limiters as the bias voltage increases. Turbulent transport for impurity ions is inferred by following ion trajectories in the simulated plasma turbulence fields, showing Bohm-like effective diffusion rates. All in all, the model elucidates the key physical phenomena governing the effects of ICRF-induced antenna biasing on the tokamak boundary plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗