Search NASA⌕ Search

SEARCH · Search NASA

Results for “DESTRUCTIVE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

C-130: Results of center wing residual strength and crack propagation test program

Fourteen C-130 airplane center wings which had experienced from approximately 4,000 to 13,000 hours of flight service and its associated fatigue damage were tested to destruction, seven in upbending and seven in downbending. Six wings were tested directly for static residual strength in the fatigue-damaged condition as received from field service. The other eight wings were tested in crack propagation cyclic testing at a prescribed stress level for a maximum of 10,000 cycles. Then the stress level was reduced and testing was continued up to a maximum of 20,000 total cycles. Cyclic testing was performed with constant-amplitude stresses at a stress ratio of +0.1. Maximum cyclic skin stresses were approximately 18,000 psi. At the conclusion of cyclic testing, a static test to destruction was conducted to determine the residual strength of each fatigue-damaged specimen.

Reeder, F. L.↗

Modal Test Technology as Non-Destructive Evaluation of Space Shuttle Structures

Modal test and analysis Is being used for nondestructive evaluation of Space Shuttle structures. The purpose of modal testing is to measure the dynamic characteristics of a structure to extract its resonance frequencies, damping, and mode shapes. These characteristics are later compared to subsequently acquired characteristics. Changes in the modal characteristics indicate damage in the structure. Use of modal test technology as a damage detection tool was developed at JSC during the Shuttle acoustic certification program and subsequent test programs. The Shuttle Modal Inspection System was created in order to inspect areas that are impossible or impractical to inspect with conventional methods. Areas on which this technique has been applied include control surfaces, which are covered with thermal protection tiles, and the Forward Reaction Control Module, which is a frame structure that supports various tanks, thrusters, and fluid lines, which requires major disassembly to inspect. This paper traces the development of the technology, gives a status of its implementation on the Shuttle, explains challenges involved in implementing this type of inspection program, and suggests future improvements in data analysis and interpretation. Dual-use applications of the technology include inspections of bridges, oil-platforms, and aircraft.

Micheal S Grygler↗

Non-Contact Eddy Current Method for Assessing Proton Conductivity in Nafion Membranes

Accurate measurement of proton conductivity in Proton Exchange Membranes (PEMs) is vital for fuel cell performance and durability. This study explores eddy current testing as a non-destructive, non-contact and high-rate quality control (QC) method for measuring Nafion membrane proton conductivity, with potential for high-volume manufacturing applications.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of long term storage on aerospace nickel cadmium cell performance

Evaluation of the long term effects on aerospace nickel cadmium cells is described. A number of 6Ah and 12Ah capacity cells which were stored in shorted condition for 9 to 11 years at the Goddard Space Flight Center were selected for the study. Of the three tests which were initiated (initial and final destruction analyses of the test cells, electrical characterization tests, and life cycling tests) only the electrical characterization tests are completed; the other tests are scheduled to be completed by February 1987. The preliminary electrial performance data from the life cycling test and chemical composition data from the destructive testing indicate no anomalous behavior.

Yi, Thomas Y.↗

Assessment of Electrical, Electronic, and Electromechanical (EEE) Parts Copper Wire Bonds for Space Programs

The NASA Electronic Parts and Packaging Program co-manager, requested the NASA Engineering and Safety Center (NESC) to compile a body of publicly available knowledge on copper (Cu) wire bonds and perform reliability testing and analysis on these bonds, including environment tests, sample destructive physical analysis, and bond pull/shear tests during environment test intervals. The goal was to understand the risks of using Cu wire bonds for space applications and develop guidelines on Cu bond pull/shear limits for NASA applications. This document contains the results of the NESC assessment.

Electrical, Electronic, and Electromechanical↗

Brazing SiC/SiC Composites to Metals

Experiments have shown that active brazing alloys (ABAs) can be used to join SiC/SiC composite materials to metals, with bond strengths sufficient for some structural applications. The SiC/SiC composite coupons used in the experiments were made from polymerbased SiC fiber preforms that were chemical-vapor-infiltrated with SiC to form SiC matrices. Some of the metal coupons used in the experiments were made from 304 stainless steel; others were made from oxygen-free, high-conductivity copper. Three ABAs were chosen for the experiments: two were chosen randomly from among a number of ABAs that were on hand at the time; the third ABA was chosen because its titanium content (1.25 percent) is less than those of the other two ABAs (1.75 and 4.5 percent, respectively) and it was desired to evaluate the effect of reducing the titanium content, as described below. The characteristics of ABAs that are considered to be beneficial for the purpose of joining SiC/SiC to metal include wettability, reactivity, and adhesion to SiC-based ceramics. Prior to further development, it was verified that the three chosen ABAs have these characteristics. For each ABA, suitable vacuum brazing process conditions were established empirically by producing a series of (SiC/SiC)/ABA wetting samples. These samples were then sectioned and subjected to scanning electron microscopy (SEM) and energy-dispersive x-ray spectrometry (EDS) for analysis of their microstructures and compositions. Specimens for destructive mechanical tests were fabricated by brazing of lap joints between SiC/SiC coupons 1/8-in. (.3.2- mm) thick and, variously, stainless steel or copper tabs. The results of destructive mechanical tests and the SEM/EDS analysis were used to guide the development of a viable method of brazing the affected materials.

Steffier, Wayne S.↗

Contamination control in hybrid microelectronic modules

Thin and thick film test specimens were utilized to study the effects of silicone and epoxy hybrid microcircuit coatings on 0.025 mm diameter aluminum and gold ultrasonic bonds, and 0.051 diameter gold pulsed-thermocompression bonds. Chip-to-substrate and substrate-to-substrate geometries were included. Because sealed packages were utilized, a test pattern design was incorporated that allowed the determination of bond failures by making resistance measurements external to the package after the various environmental tests. All wire bonds were non-destructively pull tested prior to sealing. Tests included the PIN test, temperature cycling, and high temperature storage.

Himmel, R. P.↗

Texas Instrument DRV8881 2.5A Dual H-Bridge Motor Driver Heavy-Ion Single-Event Effects Test Report

The purpose of this test was to characterize the single-event effects (SEE) susceptibility of the Texas Instrument (TI) DRV8881 2.5A Dual H-Bridge Motor Driver. The device’s output was monitored for changes during exposure to heavy-ions at Lawrence Berkeley National Laboratory (LBNL) 88-inch Cyclotron. The main goal of testing was to test for destructive SEEs. Nondestructive SEEs were recorded during testing but not fully characterized. Testing was performed on November 9th and 11th, 2022.

Thomas A. Carstens↗

Destructive PIE and Safety Testing of Six AGR-2 UO 2 Capsule 3 Compacts

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s second irradiation experiment (AGR-2) was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) from June 2010 to October 2013 (Collin 2014). The fuel compacts in this experiment held either tristructural isotropic (TRISO)-coated spherical kernels of uranium oxide (UO2) or TRISO-coated kernels containing both uranium carbide and uranium oxide phases (UCO). There were six separately monitored and controlled capsules in the AGR-2 test train. Capsule 3 held twelve compacts containing UO2-TRISO particles fabricated by BWX Technologies Nuclear Operations Group. The AGR-2 TRISO particles were fabricated in a pilot-scale fluidized-bed chemical vapor deposition (FB-CVD) furnace with a coating chamber inner diameter of 150 mm (Phillips, Barnes, and Hunn 2010), which was a change from the first irradiation experiment (AGR-1) particles that had been coated in a lab-scale FB-CVD coating system with a chamber inner diameter of 50 mm (Lowden 2006). The TRISO particles were overcoated with resinated graphite flake at Oak Ridge National Laboratory (ORNL), and the overcoated particles were pressed into one-inch-long, half-inch-diameter cylinders (Hunn, Montgomery, and Pappano 2010). Each cylindrical compact held an average of 1,543 TRISO particles with 9.6% enriched UO2 kernels that had a nominal diameter of 500 μm (Hunn, Savage, and Silva 2012). Capsule 3 compacts were irradiated to average calculated burnups of 9.01–10.69% fissions per initial metal atom (FIMA), and the average calculated fluences of fast neutrons with energies E n > 0.18 MeV were 3.05–3.53×10 25 n/m 2 (Sterbentz 2014). The calculated time-average, volume-average Capsule 3 compact temperatures were 996–1,062°C. However, Capsule 3 compact temperatures varied several hundred degrees across each compact, and the timeaverage minimum (TA min ) and time-average maximum (TA max ) temperatures were between 889–999°C and 1,072–1,105°C, respectively (Hawkes 2014). After irradiation, the AGR-2 test train was transferred from ATR to the INL Materials and Fuels Complex for inspection and disassembly (Ploger, Demkowicz, and Harp 2015). The initial inspection included dimensional metrology of the compacts and graphite fuel holders. Like all the AGR-2 compacts, the compacts in Capsule 3 shrank slightly during irradiation, as expected, with an average length reduction of 1.07–1.24% and an average diameter reduction of 0.13–0.41%. Post-irradiation examination (PIE) of the capsule components was completed to measure select fission products ( 90 Sr, 110m Ag, 134 Cs, 137 Cs, 144 Ce, and 154 Eu) outside the compacts (Stempien and Demkowicz 2020). This involved gamma counting of the graphite and graphoil spacers at the top and bottom of each capsule, acid leaching for radiochemical analysis of fission products on the metallic capsule components, and burn-leach analysis of the graphite holders. The total amount of 110mAg measured on the Capsule 3 components was 13% of the calculated capsule inventory. This was significantly lower than the amount of 110m Ag measured on the three UCO capsule components, which ranged from 32–70%. The lower 110m Ag release in Capsule 3 was likely due to lower peak temperatures compared with the UCO fuel capsules (Hawkes 2014). Measured inventories of the other select fission products were also lower in Capsule 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Destructive Physical Analysis of Flight- and Ground-Tested Sodium-Sulfur Cells

Destructive physical analysis (DPA) was used to study the effects of microgravity on the sulfur electrode in sodium-sulfur cells. The cells examined in this work were provided by the Air Force Research Laboratory (AFRL) from their program on sodium-sulfur technology. The Naval Research Laboratory (NRL) provided electrical characterization of the flight-tested and ground-tested cells.

Wasz, Margot L.↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Residual life assessment of the SSME/ATD HPOTP turnaround duct (TAD)

This paper is concerned with the prediction of the low cycle thermal fatigue behavior of a component in a developmental (ATD) high pressure liquid oxygen turbopump (HPOTP) for the Space Shuttle Main Engine (SSME). This component is called the Turnaround Duct (TAD). The TAD is a complex single piece casting of MAR-M-247 material. Its function is to turn the hot turbine exhaust gas (1200 F hydrogen rich gas steam) such that it can exhaust radially out of the turbopump. In very simple terms, the TAD consists of two rings connected axially by 22 hollow airfoil shaped struts with the turning vanes placed at the top, middle, and bottom of each strut. The TAD is attached to the other components of the pump via bolts passing through 14 of the 22 struts. Of the remaining 8 struts, four are equally spaced (90 deg interval) and containing a cooling tube through which liquid hydrogen passes on its way to cool the shaft bearing assemblies. The remaining 4 struts are empty. One of the pump units in the certification test series was destructively examined after 22 test firings. Substantial axial cracking was found in two of the struts which contain cooling tubes. None of the other 20 struts showed any sign of internal cracking. This unusual low cycle thermal fatigue behavior within the two cooling tube struts is the focus of this study.

Gross, R. Steven↗

Determination of Parachute Joint Factors using Seam and Joint Testing

This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

Mollmann, Catherine↗

Study of limitations and attributes of microprocessor testing techniques

All microprocessor units have a similar architecture from which a basic test philosophy can be adopted and used to develop an approach to test each module separately in order to verify the functionality of each module within the device using the input/output pins of the device and its instruction set; test for destructive interaction between functional modules; and verify all timing, status information, and interrupt operations of the device. Block and test flow diagrams are given for the 8080, 8008, 2901, 6800, and 1802 microprocessors. Manufacturers are listed and problems encountered in testing the modules are discussed. Test equipment and methods are described.

Mccaskill, R.↗

Optimization Approach for Wind Tunnel Fan Blade Strain Gage Correlation with Test Fixture Unknowns

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the Agency. Some wind tunnel fan blades, such as those in the National Transonic Facility at NASA Langley Research Center, have been in use for far longer than their planned 10-year lifetime. No detailed analytical models of the fan blades from their initial fabrication were created. To support the fabrication of either new, nominally identical fan blades or newly designed fan blades, accurate analytical models of the existing fan blades are necessary to demonstrate an understanding of the capabilities of the existing fan blades. Additionally, the existing documentation of the testing of the existing fan blades has gaps. In this report, a process for improving test-analysis correlation for these wind tunnel fan blades is discussed. This process involved a detailed study of unknown parameters in test fixture parameters from the old and incomplete test documentation. To improve correlation, these unknown parameters were used as design variables in an optimization study to minimize the error between test data and computed structural responses. Legacy strain gage data from tests conducted in 1981 were compared with results from a finite element model created in 2019. The use of test data from 1981 was necessary because none of the existing fan blades could be spared for use in destructive structural testing. While this process was demonstrated for wind tunnel fan blades, this process could be utilized for evaluating unknowns in test fixtures for other structural test configurations.

wind tunnel↗

Single-Event Effect Report for EPC Series eGaN FETs: Comparison of EPC1000 and EPC2000 Series Devices for Destructive SEE

Recent testing of the EPC1000 series eGaN FETs has shown sensitivity to Single Event Effects (SEE) that are destructive. These effects are most likely the failure of the very thin gate structure in HEMT architecture. EPC has recently changed the doping of the substrate to improve the performance and the SEE response. This testing compares the SEE response of both devices.

Scheick, Leif↗