Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Field Characteristics of Spin-Torque Diode Sensitivity in the Presence of a Bias Current

The use of the spin-torque diode effect, which is generated upon the current-induced transfer of spin angular momentum in magnetic tunnel junctions, opens the prospect of considerably improving microwave sensitivity in the gigahertz frequency band over that of semiconductor Schottky diodes. In this work, the spin-diode effect of microwave signal rectification in a magnetic tunnel junction upon the resonant excitation of spin waves in the free magnetic layer as a result of the current-induced spin-transfer torque effect is analyzed theoretically. Frequency characteristics of the resonant response of a spin-torque diode to a microwave signal are calculated in the linear macrospin approximation as functions of the direction and value of the applied magnetic field and bias current. It is shown that with zero bias current, the maximum rectified voltage across a junction is obtained in the geometry of mutually perpendicular magnetizations of magnetic layers; as the resonant frequency of oscillations in a magnetic field increases, this voltage drops at the retained equilibrium orientation of spins in the layers. After the bias current is switched on, the resonance amplitude of forced oscillations of the free layer spins upon microwave excitation grows sharply at the critical point of the spin-torque diode’s loss of equilibrium state stability. The linewidth at this point is limited only by nonlinear effects. Improving spin-torque diode sensitivity is important for its use in microwave holographic vision systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design tradeoffs between traditional hexagonal and emerging cubic In X Ga (1–X) N/GaN-based green light-emitting diodes

Here, we report on the design tradeoffs between traditional hexagonal and emerging cubic In X Ga (1–X) N/GaN -based green (520 nm≤ λ ≤550 nm) light-emitting diodes with special emphasis on the electron blocking layer, number of quantum wells, and thicknesses of quantum wells and barriers. We identified three crucial design rules for cubic green light-emitting diodes: (1) no need for an electron blocking layer; (2) use of a wide quantum well; and (3) choice of thin quantum barriers in multi-quantum well light-emitting diode designs. These design rules increase the internal quantum efficiency of cubic green light-emitting diodes by ~30.5% under 100A/cm 2 injection with respect to traditional designs. Overall, the design rules of cubic light-emitting diodes and their differentiating nature from the traditional, hexagonal ones are crucial for the advent of next-generation cubic light-emitting diodes.

42 ENGINEERING↗

Aging Mechanisms of Broad Area High-Power ~800nm Laser Diodes

Improved lifetime of high-power broad area laser diodes will enhance their utility for manufacturing, scientific, and medical laser systems. However, factors contributing to gradual degradation of diode laser performance are not fully understood. Here we study the aging mechanisms of ~800 nm aluminum-free laser diodes grown by solid-source MBE. Oxygen was intentionally introduced at three different concentration levels into the quantum well (QW) and waveguide (WG) at concentrations <5×10 15 cm -3 . Diode power, slope efficiency (SE th ), threshold current (I th ), and device parameters such as QW and WG lifetimes were measured at discrete time steps throughout the aging run. The data show that lasing characteristics prior to aging are degraded by oxygen introduction, but the gradual power degradation rate of ~5% over 500 hours at current density 1.74 kA/cm 2 does not change with oxygen concentration. Aging-induced changes in nonradiative lifetimes and threshold were observed for shorter aging times, but stabilized after ~100 hrs. and cannot explain the observed power degradation. This suggests that gradual degradation in these devices is not due to nonradiative recombination at low levels of point defects. The data shows that this degradation results primarily from changes in slope efficiency, and simulation of these results suggests that the power degradation arises from increased intracavity absorption (ICA). Efforts to slow ICA growth, instead of efforts to control low levels of nonradiative recombination centers, may be the most fruitful path forward to improve laser diode lifetime.

42 ENGINEERING↗

Determination of electrical parameters of ITO/CZTS/CdS/Ag and ITO/CdS/CZTS/Ag heterojunction diodes in dark and illumination conditions

In this work, ITO/CZTS/CdS/Ag and ITO/CdS/CZTS/Ag heterojunction diodes has been produced, CdS and CZTS thin film layers of the diode have been produced on ITO glass at room temperature using PLD technique. It has been produced CZTS thin films that have a polycrystalline structure that were annealed at the sulfurization temperatures of 325 °C, 350 °C and 375 °C when as-grown CZTS thin film has the amorphous structure. CdS thin films have been grown on substrate at room temperature in 15, 20 and 25 min that have polycrystalline structures. Then, CdS thin film deposited for 20 min was annealed at 200 °C temperature and, has better crystal structure compared to other thin films. Diodes have been composed of CZTS thin film annealed in 375 °C, CdS thin film was grown during 20 min and, then annealed at 200 °C temperature. According to J–V characteristics of diode, diodes exhibit some rectification behaviour in dark and show a photo-electric property under illumination conditions. In this article, the ideality factors of diodes in dark condition have been calculated, their electrical parameters of J{sub sc}, V{sub oc}, FF and η under the illumination condition have been determined and these electrical properties have been discussed in details.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field-resilient supercurrent diode in a multiferroic Josephson junction

The research on supercurrent diodes has surged rapidly due to their potential applications in electronic circuits at cryogenic temperatures. To unlock this functionality, it is essential to find supercurrent diodes that can work consistently at zero magnetic field and under ubiquitous stray fields generated in electronic circuits. However, a supercurrent diode with robust field tolerance is currently lacking. Here, we demonstrate a field-resilient supercurrent diode by incorporating a 2D multiferroic material into a Josephson junction, and observed a pronounced supercurrent diode effect at zero magnetic field. More importantly, the supercurrent rectification persists over a wide and bipolar magnetic field range beyond industrial standards for field tolerance. By theoretically modeling a multiferroic Josephson junction, we unveil that the interplay between spin-orbit coupling and multiferroicity underlies the unusual field resilience of the observed diode effect. This work introduces multiferroic Josephson junctions as a new field-resilient superconducting device for cryogenic electronics.

Yang, Hung-Yu [Univ. of California, Los Angeles, C↗

Tests of by-pass diodes at cryogenic temperatures for the KATRIN magnets

The Karlsruhe Tritium Neutrino experiment (KATRIN) requires a series of superconducting solenoid magnets for guiding beta-electrons from the source to the detector. By-pass diodes will operate at liquid helium temperatures to protect the superconducting magnets and bus bars in case of quenches. The operation conditions of the by-pass diodes depend on the different magnet systems of KATRIN. Therefore, different diode stacks are designed with adequate copper heat sinks assuming adiabatic conditions. The by-pass diode stacks have been submitted to cold tests both at liquid nitrogen and liquid helium temperatures for checking operation conditions. This report presents the test set up and first results of the diode characteristics at 300 K and 77 K, as well as of endurance tests of the diode stacks at constant current load at 77 K and 4.2 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trap-induced photoconductivity in singlet fission pentacene diodes

This paper reports a trap-induced photoconductivity in ITO/pentacene/Al diodes by using current-voltage and magneto-conductance measurements. The comparison of photoconductivity between pentacene diodes with and without trap clearly shows that the traps play a critical role in generating photoconductivity. It shows that no observable photoconductivity is detected for trap-free pentacene diodes, while significant photoconductivity is observed in diodes with trap. This is because the initial photogenerated singlet excitons in pentacene can rapidly split into triplet excitons with higher binding energy prior to dissociating into free charge carriers. The generated triplet excitons react with trapped charges to release charge-carriers from traps, leading to a trap-induced photoconductivity in the single-layer pentacene diodes. Our studies elucidated the formation mechanisms of photoconductivity in pentacene diodes with extremely fast singlet fission rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulative research on the anode plasma dynamics in the high-power electron beam diode

Anode plasma generated by electron beams could limit the electrical pulse-length, modify the impedance and stability of diode, and affect the generator to diode power coupling. In this paper, a particle-in-cell code is used to study the dynamics of anode plasma in the high-power electron beam diode. The effect of gas type, dynamic characteristic of ions on the diode operation with bipolar flow model are presented. With anode plasma appearing, the amplitude of diode current is increased due to charge neutralizations of electron flow. The lever of neutralization can be expressed using saturation factor. At same pressure of the anode gas layer, the saturation factor of CO{sub 2} is bigger than the H{sub 2}O vapor, namely, the generation rate of C{sup +} ions is larger than the H{sup +} ions at the same pressure. The transition time of ions in the anode-cathode gap could be used to estimate the time of diode current maximum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low absorption loss p-AlGaN superlattice cladding layer for current-injection deep ultraviolet laser diodes

Current injection into AlGaN-based laser diode structures with high aluminum mole fractions for deep ultraviolet emission is investigated. The electrical characteristics of laser diode structures with different p-AlGaN short period superlattice (SPSL) cladding layers with various aluminum mole fractions are compared. The heterostructures contain all elements that are needed for a current-injection laser diode including cladding and waveguide layers as well as an AlGaN quantum well active region emitting near 270 nm. We found that with increasing aluminum content in the p-AlGaN cladding, the diode turn-on voltage increases, while the series resistance slightly decreases. By introducing an SPSL instead of bulk layers, the operating voltage is significantly reduced. A gain guided broad area laser diode structure with transparent p-Al{sub 0.70}Ga{sub 0.30}N waveguide layers and a transparent p-cladding with an average aluminum content of 81% was designed for strong confinement of the transverse optical mode and low optical losses. Using an optimized SPSL, this diode could sustain current densities of more than 4.5 kA/cm{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multi-dimensional Child–Langmuir law for any diode geometry

While prior theoretical studies of multi-dimensional space-charge limited current (SCLC) assumed emission from a small patch on infinite electrodes, none have considered emission from an entire finite electrode. In this paper, we apply variational calculus (VC) and conformal mapping, which have previously been used to derive analytic solutions for SCLC density (SCLCD) for nonplanar one-dimensional geometries, to obtain mathematical relationships for any multi-dimensional macroscopic diode with finite cathode and anode. We first derive a universal mathematical relationship between space-charge limited potential and vacuum potential for any diode and apply this technique to determine SCLCD for an eccentric spherical diode. We then apply VC and the Schwartz–Christoffel transformation to derive an exact equation for SCLCD in a general two-dimensional planar geometry with emission from a finite emitter. Particle-in-cell simulations using VSim agreed within 4%–13% for a range of ratios of emitter width to gap distance using the thinnest electrodes practical for the memory constraints of our hardware, with the difference partially attributed to the theory's assumption of infinitesimally thin electrodes. After generalizing this approach to determine SCLCD for any orthogonal diode as a function of only the vacuum capacitance and vacuum potential, we derive an analytical formulation of the three-dimensional Child–Langmuir law for finite parallel rectangular and disk geometries. These results demonstrate the utility for calculating SCLCD for any diode geometry using vacuum capacitance and vacuum potential, which are readily obtainable for many diode geometries, to guide experiment and simulation development.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material

Purpose: For external beam in vivo measurements, the dosimeter is normally placed on the patient's skin, and the dose to a point of interest inside the patient is derived from surface measurements. In order to obtain accurate and reliable measurements, which correlate with the dose values predicted by a treatment planning system, a dosimeter needs to be at a point of electronic equilibrium. This equilibrium is accomplished by adding material (buildup) above the detector. This paper examines the use of buildup caps in a clinical setting for two common detector types: OSLDs and diodes. Clinically built buildup-caps and commercially available hemispherical caps are investigated. The effects of buildup cap thickness and fabrication material on field-size correction factors, C{sub FS}, are reported, and differences between the effects of thickness and fabrication material are explained based on physical parameters. Methods: Measurements are made on solid water phantoms for 6 and 15 MV x-ray beams. Two types of dosimeters are used: OSLDs, InLight/OSL Nanodot dosimeters (Landauer, Inc., Glenwood, IL) and a P-type surface diode (Standard Imaging, Madison, WI). Buildup caps for these detectors were fabricated out of M3, a water-equivalent material, and sheet-metal stock of Al, Cu, and Pb. Also, commercially available hemispherical buildup caps made of plastic water and brass (Landauer, Inc., Glenwood, IL) were used with Nanodots. OSLDs were read with an InLight microStar reader (Landauer, Inc., Glenwood, IL). Dose calculations were carried out with the XiO treatment planning system (CMS/Elekta, Stockholm) with tissue heterogeneity corrections. Results: For OSLDs and diodes, when measurements are made with no buildup cap a change in C{sub FS} of 200% occurs for a field-size change from 3 cm x 3 cm to 30 cm x 30 cm. The change in C{sub FS} is reduced to about 4% when a buildup cap with wall thickness equal to the depth of maximum dose is used. Buildup caps with larger wall thickness do not cause further reduction in C{sub FS}. The buildup cap fabrication material has little or no effect on C{sub FS}. The perturbation to the delivered dose caused by placing a detector with a buildup cap on the surface of a patient is measured to be 4%-7%. A comparison between calculated dose and dose measured with a Nanodot and a diode for 6 and 15 MV x-rays is made. When C{sub FS} factors are carefully determined and applied to measurements made on a phantom, the differences between measured and calculated doses were found to be between {+-}1.3%. Conclusions: OSLDs and diodes with appropriate buildup caps can be used to measure dose on the surface of a patient and predict the delivered dose to depth dmax in a range of {+-}1.3% for 100 cGy. The buildup cap: can be fabricated from any material examined in this work, is best with wall thickness dmax, and causes a perturbation to the delivered dose of 4%-7% when the wall thickness is dmax. OSLDs and diodes with buildup caps can both give accurate measurements of delivered dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors

Purpose: The goal of this work was to implement a recently proposed small field dosimetry formalism [Alfonso et al., Med. Phys. 35(12), 5179-5186 (2008)] for a comprehensive set of diode detectors and provide the required Monte Carlo generated factors to correct measurement. Methods: Jaw collimated square small field sizes of side 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, and 3.0 cm normalized to a reference field of 5.0 cm x 5.0 cm were used throughout this study. Initial linac modeling was performed with electron source parameters at 6.0, 6.1, and 6.2 MeV with the Gaussian FWHM decreased in steps of 0.010 cm from 0.150 to 0.100 cm. DOSRZnrc was used to develop models of the IBA stereotactic field diode (SFD) as well as the PTW T60008, T60012, T60016, and T60017 field diodes. Simulations were run and isocentric, detector specific, output ratios (OR{sub det}) calculated at depths of 1.5, 5.0, and 10.0 cm. This was performed using the following source parameter subset: 6.1 and 6.2 MeV with a FWHM = 0.100, 0.110, and 0.120 cm. The source parameters were finalized by comparing experimental detector specific output ratios with simulation. Simulations were then run with the active volume and surrounding materials set to water and the replacement correction factors calculated according to the newly proposed formalism. Results: In all cases, the experimental field size widths (at the 50% level) were found to be smaller than the nominal, and therefore, the simulated field sizes were adjusted accordingly. At a FWHM = 0.150 cm simulation produced penumbral widths that were too broad. The fit improved as the FWHM was decreased, yet for all but the smallest field size worsened again at a FWHM = 0.100 cm. The simulated OR{sub det} were found to be greater than, equivalent to and less than experiment for spot size FWHM = 0.100, 0.110, and 0.120 cm, respectively. This is due to the change in source occlusion as a function of FWHM and field size. The corrections required for the 0.5 cm field size were 0.95 ({+-}1.0%) for the SFD, T60012 and T60017 diodes and 0.90 ({+-}1.0%) for the T60008 and T60016 diodes--indicating measured output ratios to be 5% and 10% high, respectively. Our results also revealed the correction factors to be the same within statistical variation at all depths considered. Conclusions: A number of general conclusions are evident: (1) small field OR{sub det} are very sensitive to the simulated source parameters, and therefore, rigorous Monte Carlo linac model commissioning, with respect to measurement, must be pursued prior to use, (2) backscattered dose to the monitor chamber should be included in simulated OR{sub det} calculations, (3) the corrections required for diode detectors are design dependent and therefore detailed detector modeling is required, and (4) the reported detector specific correction factors may be applied to experimental small field OR{sub det} consistent with those presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for microchamber and diode detectors

Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm iris collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-270: A Technique for Modeling a Diode Array Into the TPS for Lung SBRT Patient Specific QA

Purpose: To accurately match the treatment planning system (TPS) with the measurement environment, where quality assurance (QA) devices are used to collect data, for lung Stereotactic Body Radiation Therapy (SBRT) patient specific QA. Incorporation of heterogeneities is also studied. Methods: Dual energy computerized tomography (DECT) and single energy computerized tomography (SECT) were used to model phantoms incorporating a 2-D diode array into the TPS. A water-equivalent and a heterogeneous phantom (simulating the thoracic region of a patient) were studied. Monte Carlo and pencil beam planar dose distributions were compared to measured distributions. Composite and individual fields were analyzed for normally incident and planned gantry angle deliveries. γ- analysis was used with criteria 3% 3mm, 2% 2mm, and 1% 1mm. Results: The Monte Carlo calculations for the DECT resulted in improved agreements with the diode array for 46.4% of the fields at 3% 3mm, 85.7% at 2% 2mm, and 92.9% at 1% 1mm.For the SECT, the Monte Carlo calculations gave no agreement for the same γ-analysis criteria. Pencil beam calculations resulted in lower agreements with the diode array in the TPS. The DECT showed improvements for 14.3% of the fields at 3% 3mm and 2% 2mm, and 28.6% at 1% 1mm.In SECT comparisons, 7.1% of the fields at 3% 3mm, 10.7% at 2% 2mm, and 17.9% at 1% 1mm showed improved agreements with the diode array. Conclusion: This study demonstrates that modeling the diode array in the TPS is viable using DECT with Monte Carlo for patient specific lung SBRT QA. As recommended by task groups (e.g. TG 65, TG 101, TG 244) of the American Association of Physicists in Medicine (AAPM), pencil beam algorithms should be avoided in the presence of heterogeneous materials, including a diode array.

60 APPLIED LIFE SCIENCES↗

Electrical and Thermal Finite Element Modeling of Arc Faults in Photovoltaic Bypass Diodes

Arc faults in photovoltaic (PV) modules have caused multiple rooftop fires. The arc generates a high-temperature plasma that ignites surrounding materials and subsequently spreads the fire to the building structure. While there are many possible locations in PV systems and PV modules where arcs could initiate, bypass diodes have been suspected of triggering arc faults in some modules. In order to understand the electrical and thermal phenomena associated with these events, a finite element model of a busbar and diode was created. Thermoelectrical simulations found Joule and internal diode heating from normal operation would not normally cause bypass diode or solder failures. However, if corrosion increased the contact resistance in the solder connection between the busbar and the diode leads, enough voltage potentially would be established to arc across micron-scale electrode gaps. Lastly, an analytical arc radiation model based on observed data was employed to predicted polymer ignition times. The model predicted polymer materials in the adjacent area of the diode and junction box ignite in less than 0.1 seconds.

14 SOLAR ENERGY↗

Investigations of shot reproducibility for the SMP diode at 4.5 MV.

In experiments conducted on the RITS-6 accelerator, the SMP diode exhibits sig- ni cant shot-to-shot variability. Speci cally, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. To remove knob emission as a source, only data from a shot series conducted with a 4.5-MV peak voltage are considered. The scope of this report is limited to sources of variability which occur away from the diode, such as power ow emission and trajectory changes, variations in pulsed power, dustbin and transmission line alignment, and di erent knob shapes. We nd no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we nd that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance pro les. This result forms the basis of a follow-on study focusing on the variability resulting from diode physics. 3

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vertical GaN PIN Diodes with 5 kV Avalanche Breakdown.

High voltage diodes are desired for many high power switching applications. GaN pin diodes have the potential to replace conventional silicon diodes for applications requiring very low size and weight, and high power. GaN diodes have several advantages including the ability to operate at high temperatures and a higher tolerance to radiation damage. The focus of this exploratory express LDRD is to develop a detailed understanding of GaN pin diodes with the goal of demonstrating devices with a reverse breakdown voltage of greater than 5 kV. Although the breakdown voltage is nominally determined by the thickness and doping of the drift region, it is known that the edge termination of the device is of critical importance in achieving the optimum reverse bias characteristics. Therefore, as a part of this project, edge termination effects were carefully investigated both experimentally and theoretically in order to understand GaN pin device operation. Specifically, we investigated the impact of the thickness of the implanted region in the p-type GaN layer and its effect on reverse bias characteristics. Through proper design and fabrication of GaN pin diodes it is possible to demonstrate devices with a 5 kV or greater reverse bias breakdown voltage.

42 ENGINEERING↗