Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Unlocking Synergistic Benefits of Colocation of Data Centers at Airports

This white paper evaluates the potential of a new energy system configuration: Strategic colocation of data centers - on airport property or adjacent to airports - in order to realize significant operational, economic, and environmental benefits to airports, data centers, and the communities they serve. While increasing demand from both airports and data centers requires both parties to make significant infrastructure investments, colocation can mitigate some of the energy, land use, permitting, and connectivity challenges of siting and powering these industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data center cooling method

A method aspect for removing heat from a data center may use liquid coolant cooled without vapor compression refrigeration on a liquid cooled information technology equipment rack. The method may also include regulating liquid coolant flow to the data center through a range of liquid coolant flow values with a controller-apparatus based upon information technology equipment temperature threshold of the data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Thermosyphon Hybrid Cooling System to Optimize Data Center Water Efficiency

Driven by a mission to push the leading edge for data center sustainability, NREL recognized the need to make its data center not just energy efficient, but water efficient, too. So, in 2016, NREL, with partners Johnson Controls and Sandia National Laboratories, deployed an innovative thermosyphon cooler (TSC) as a test bed on the roof of the NREL's Energy Systems Integration Facility (ESIF). In combination with existing evaporative towers, the TSC forms an extremely water-and cost-efficient hybrid cooling system.

97 MATHEMATICS AND COMPUTING↗

Addressing Data Center Cooling Needs through the Use of Subsurface Thermal Energy Storage Systems

This study aims to evaluate the feasibility of addressing the cooling needs for information technology (IT) equipment in data centers by using reservoir thermal energy storage (RTES) to provide reliable and sustainable low-temperature fluid. This project focuses on the technical viability of operating such a system in Houston, Texas, which is a representative location for crypto mining data centers. An analysis has been performed to investigate the technical feasibility with climate data for Houston. Results show that data centers on the scale of 30 MW, and operating at a temperature of 27 degrees C, can be reliably cooled by a combined RTES and dry coolers setup. A techno-economic analysis will be performed and energy/water saving benefits will be quantified in the future. In addition, the study will be extended to other representative data center locations with different climates and geographical locations.

cooling↗

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

Data Center Energy Efficiency Measurement Assessment Kit Guide and Specification

A portable and temporary wireless mesh assessment kit can be used to speed up and reduce the costs of a data center energy use assessment and overcome the issues with respect to shutdowns. The assessment kit is comprised of temperature, relative humidity, and pressure sensors. Also included are power meters that can be installed on computer room air conditioners (CRACs) without intrusive interruption of data center operations. The assessment kit produces data required for a detailed energy assessment of the data center.

Data, Center, Energy, Efficiency, Measurement, Ass↗

Navigating Economies of Scale and Multiples for Nuclear-Powered Data Centers and Other Applications with High Service Availability Needs

Nuclear energy is increasingly being considered for such targeted energy applications as data centers in light of their high capacity factors and low carbon emissions. This paper focuses on assessing the tradeoffs between economies of scale versus mass production to identify promising reactor sizes to meet data center demands. A framework is then built using the best cost estimates from the literature to identify ideal reactor power sizes for the needs of the given data center. Results should not be taken to be deterministic but highlight the variability of ideal reactor power output against the required demand. While certain advocates claim that with the gigawatts of clean, firm energy needed, large plants are ideal, others advocate for SMRs that can be deployed in large quantities and reap the benefits from learning effects. The findings of this study showcase that identifying the optimal size for a reactor is likely more nuanced and dependent on the application and its requirements. Overall, the study does show potential economic promise for coupling nuclear reactors to data centers and industrial heat applications under certain key conditions and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated SOAs enable energy-efficient intra-data center coherent links

Coherent optical links are becoming increasingly attractive for intra-data center applications as data rates scale. Realizing the era of high-volume short-reach coherent links will require substantial improvements in transceiver cost and power efficiency, necessitating a reassessment of conventional architectures best-suited for longer-reach links and a review of assumptions for shorter-reach implementations. In this work, we analyze the impact of integrated semiconductor optical amplifiers (SOAs) on link performance and power consumption, and describe the optimal design spaces for low-cost and energy-efficient coherent links. Placing SOAs after the modulator provide the most energy-efficient link budget improvement, up to 6 pJ/bit for large link budgets, despite any penalties from nonlinear impairments. Increased robustness to SOA nonlinearities makes QPSK-based coherent links especially attractive, and larger supported link budgets enable the inclusion of optical switches, which could revolutionize data center networks and improve overall energy efficiency.

Maharry, Aaron (ORCID:0000000273732697)↗

Deployment of inference as a service at the US CMS Tier-2 data centers

Coprocessors, especially GPUs, will be a vital ingredient of data production workflows at the HL-LHC. At CMS, the GPU-as-a-service approach for production workflows is implemented by the SONIC project (Services for Optimized Network Inference on Coprocessors). SONIC provides a mechanism for outsourcing computationally demanding algorithms, such as neural network inference, to remote servers, where requests from multiple clients are intelligently distributed across multiple GPUs by a load-balancing service. This talk highlights the recent progress in deploying SONIC at selected U.S. CMS Tier-2 data centers. Using realistic CMS Run3 data processing workflows, such as those containing transformer-based algorithms, we demonstrate how SONIC is integrated into the production-like environment to enable accelerated inference offloading. We will present developments from both the client and server sides, including production job and data center configurations for NVIDIA and AMD GPUs. We will also present performance scaling benchmarks and discuss the challenges of operating SONIC in CMS production, such as server discovery, GPU saturation, fallback server logic, etc.

Holzman, Burt↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic Approach to Data Center Energy Efficiency

This presentation discusses NREL's Energy System Integrations Facility and NREL's holistic design approach to sustainable data centers that led to the world's most energy-efficient data center. It describes Peregrine, a warm water liquid cooled supercomputer, waste heat reuse in the data center, demonstrated PUE and ERE, and lessons learned during four years of operation.

97 MATHEMATICS AND COMPUTING↗

DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center

This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL and Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.

97 MATHEMATICS AND COMPUTING↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗