At least 199 records · Page 11

Ultrasensitive Nanoelectrospray Ionization-Mass Spectrometry using Poly(dimethylsiloxane) Microchips with Monolithically Integrated Emitters

Poly(dimethylsiloxane) (PDMS) is the most widely used substrate for microfluidic devices as it enables facile fabrication and has other distinctive properties. However, for applications involving highly sensitive nanoelectrospray ionization mass spectrometry (nanoESI-MS) detection, the use of PDMS microdevices has been hindered by the leaching of uncross-linked oligomers and other contaminants from the substrate that yields a large background of chemical noise in the mass spectra. A more general challenge is that microfluidic devices containing integrated electrospray emitters are frequently unable to operate stably in the nanoflow regime where the best sensitivity is achieved. In this report, we extracted the contaminants from PDMS substrates using a series of solvents, eliminating the background observed when untreated PDMS microchips are used for nanoESI-MS. Optimization of the integrated emitter geometry enabled stable operation at flow rates as low as 10 nL/min. Peptide concentrations of 1 nM were readily detected, representing ~170 zmol of consumed analyte, and an extrapolated detection limit of ~40 zmol; these are the lowest mass and concentration detection limits reported to date for a microchip having an integrated electrospray emitter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards secondary ion mass spectrometry on the helium ion microscope: An experimental and simulation based feasibility study with He{sup +} and Ne{sup +} bombardment

The combination of the high-brightness He{sup +}/Ne{sup +} atomic level ion source with secondary ion mass spectrometry detection capabilities opens up the prospect of obtaining chemical information with high lateral resolution and high sensitivity on the Zeiss ORION helium ion microscope. The analytical performance in terms of sputtering yield, useful yield, and detection limit is studied and subsequently optimized by oxygen and cesium flooding. Detection limits down to 10{sup -6} and 10{sup -5} can be obtained for silicon using Ne{sup +} and He{sup +}, respectively. A simulation based study reveals furthermore that a lateral resolution <10 nm can be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hierarchical TiO 2 :Cu 2 O Nanostructures for Gas/Vapor Sensing and CO 2 Sequestration

We investigate the effect of high-surface-area self-assembled TiO 2 :Cu 2 O nanostructures for CO 2 and relative humidity gravimetric detection using polyethylenimine (PEI), 1-ethyl-3-methylimidazolium (EMIM), and polyacrylamide (PAAm). Introduction of hierarchical TiO 2 :Cu 2 O nanostructures on the surface of quartz crystal microbalance sensors is found to significantly improve sensitivity to CO 2 and to H 2 O vapor. The response of EMIM to CO 2 increases fivefold for 100 nm-thick TiO 2 :Cu 2 O as compared to gold. At ambient CO 2 concentrations, the hierarchical assembly operates as a sensor with excellent reversibility, while at higher pressures, the CO 2 desorption rate decreases, suggesting possible application for CO 2 sequestration under these conditions. The gravimetric response of PEI to CO 2 increases by a factor of 3 upon introduction of a 50 nm TiO 2 :Cu 2 O layer. The PAAm gravimetric response to water vapor also increases by a factor of 3 and displays improved reversibility with the addition of 50 nm TiO 2 :Cu 2 O structures. We found that TiO 2 :Cu 2 O can be used to lower the detection limits for CO 2 sensing with EMIM and PEI and lower the detection limits for H 2 O sensing with PAAm by over a factor of 2. Coarse-grained and all-atom molecular dynamics simulations indicate the dissociative character of ionic liquid assembly on TiO 2 :Cu 2 O interfaces and different distributions of CO 2 and H 2 O molecules on bare and ionic liquid-coated surfaces, confirming experimental observations. Overall, our results show high potential of hierarchical assemblies of TiO 2 :Cu 2 O/room temperature ionic liquid and polymer films for sensors and CO 2 sequestration.

36 MATERIALS SCIENCE↗

Supercontinuum spatial modulation spectroscopy: Detection and noise limitations

Supercontinuum spatial modulation spectroscopy is a facile tool for conducting single molecule/particle extinction spectroscopy throughout the visible and near infrared (420–1100 nm). The technique's capabilities are benchmarked using individual Au nanoparticles (NPs) as a standard since they are well studied and display a prominent plasmon resonance in the visible. Extinction spectra of individual Au NPs with diameters (d) ranging from d ∼ 8 to 40 nm are resolved with extinction cross sections (σ{sub ext}) of σ{sub ext} ∼1 × 10{sup −13}–1 ×10{sup −11} cm{sup 2}. Corresponding signal-to-noise ratios range from ∼30 to ∼1400. The technique's limit of detection is determined to be 4.3 × 10{sup −14} cm{sup 2} (4.3 nm{sup 2}). To showcase supercontinuum spatial modulation spectroscopy's broader applicability, extinction spectra are acquired for other model systems, such as individual single-walled carbon nanotubes (SWCNTs) and CdSe nanowires. We show for the first time extinction spectra of individual (8,3) and (6,5) SWCNTs. For both chiralities, their E{sub 11} [(8,3) 1.30 eV (952 nm); (6,5) 1.26 eV (986 nm)] and E{sub 22} [(8,3) 1.86 eV (667 nm); (6,5) 2.19 eV (567 nm)] excitonic resonances are seen with corresponding cross sections of σ{sub ext} ∼ 10{sup −13} cm{sup 2} μm{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Postinflationary QCD Axions with a Quantum-Limited Tunable Microwave Receiver

A search for cosmological axions has been performed by scanning a frequency region of 38 MHz centered at about 10.2 GHz, corresponding to an axion mass 𝑚 𝑎 ≃ 42 μ ⁢eV. The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an 8 T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the 10 −14 GeV −1 level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred postinflationary region 𝑚 𝑎 > 40 μ ⁢eV.

Sardo Infirri, Giosue [INFN, Sezione di Padova; Un↗

Elemental analysis of a comet nucleus by passive gamma ray spectrometry from a penetrator

The Comet Rendezvous Asteroid Flyby (CRAF) spacecraft, to be launched in 1991, was designed to study the physical and chemical properties of cometary and asteroid bodies. It is proposed that these properties can be determined by utilizing a penetrator experiment delivery system aboard the CRAF, which would deliver a passive gamma ray spectrometer to the comet and determine the composition of subsurface materials. Results of calculations for a model comet (50 percent CI carbonaceous chrondrite, 50 percent ices) provide data on the expected gamma ray fluxes, the minimum detectable limits, and the detection uncertainties for 35 isotopes. These results confirm that this technique can determine the composition of both the rocky and ice components, and the rock-to-ice ratio in the nucleus. In addition, useful information regarding the formation of the solar system is provided.

Evans, L. G.↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VLBI observations of 416 extragalactic radio sources

The Deep Space Network is establishing a high-accuracy Very Long Base Interferometry (VLBI) celestial reference frame. Presented are the VLBI results of observations of 416 radio sources with declination north of -45 degrees which were conducted at frequencies of 2.3 GHz and 8.4 GHz. At 2.3 GHz 323 of 391 radio sources observed were detected with a fringe spacing of 3 milliarcsec and a detection limit of approximately 0.1 Jy. At 8.4 GHz, 278 of 416 radio sources were detected with a fringe spacing of 1 milliarcsec and a detection limit of approximately 0.1 Jy. This survey was conducted primarily to determine the strength of compact components at 8.4 GHz for radio sources previously detected with VLBI at 2.3 GHz. Compact extragalactic radio sources with strong correlated flux densities at both frequencies are used to form a high-accuracy reference frame.

Morabito, D. D.↗

VLBI observations of 416 extragalactic radio sources

Very long baseline interferometry (VLBI) observations of 416 radio sources with declinations north of -45 deg have been conducted at frequencies of 2.3 and 8.4 GHz. At 2.3 GHz, 323 of 391 radio sources observed were detected with a fringe spacing of 3 milliarcsec and a detection limit of about 0.1 Jy. At 8.4 GHz, 278 of 416 radio sources were detected with a fringe spacing of 1 milliarcsec and a detection limit of about 0.1 Jy. This survey was conducted primarily to determine the strength of compact components at 8.4 GHz for radio sources previously detected with VLBI at 2.3 GHz. Compact extragalactic radio sources with strong correlated flux densities at both frequencies are used to form a high-accuracy reference frame.

Morabito, D. D.↗

Modeling Latently Infected Cell Activation: Viral and Latent Reservoir Persistence, and Viral Blips in HIV-infected Patients on Potent Therapy

Although potent combination therapy is usually able to suppress plasma viral loads in HIV-1 patients to below the detection limit of conventional clinical assays, a low level of viremia frequently can be detected in plasma by more sensitive assays. Additionally, many patients experience transient episodes of viremia above the detection limit, termed viral blips, even after being on highly suppressive therapy for many years. An obstacle to viral eradication is the persistence of a latent reservoir for HIV-1 in resting memory CD4+ T cells. The mechanisms underlying low viral load persistence, slow decay of the latent reservoir, and intermittent viral blips are not fully characterized. The quantitative contributions of residual viral replication to viral and the latent reservoir persistence remain unclear. In this paper, we probe these issues by developing a mathematical model that considers latently infected cell activation in response to stochastic antigenic stimulation. We demonstrate that programmed expansion and contraction of latently infected cells upon immune activation can generate both low-level persistent viremia and intermittent viral blips. Also, a small fraction of activated T cells revert to latency, providing a potential to replenish the latent reservoir. By this means, occasional activation of latently infected cells can explain the variable decay characteristics of the latent reservoir observed in different clinical studies. Finally, we propose a phenomenological model that includes a logistic term representing homeostatic proliferation of latently infected cells. The model is simple but can robustly generate the multiphasic viral decline seen after initiation of therapy, as well as low-level persistent viremia and intermittent HIV-1 blips. Using these models, we provide a quantitative and integrated prospective into the long-term dynamics of HIV-1 and the latent reservoir in the setting of potent antiretroviral therapy.

59 BASIC BIOLOGICAL SCIENCES↗

LOW-METALLICITY YOUNG CLUSTERS IN THE OUTER GALAXY. I. Sh 2-207

To study star formation in low-metallicity environments ([M/H] ∼ −1 dex), we obtained deep near-infrared (NIR) images of Sh 2-207 (S207), which is an H ii region in the outer Galaxy with a spectroscopically determined metallicity of [O/H] ≃ −0.8 dex. We identified a young cluster in the western region of S207 with a limiting magnitude of K{sub S} = 19.0 mag (10σ) that corresponds to a mass detection limit of ≲0.1 M{sub ⊙} and enables the comparison of star-forming properties under low metallicity with those of the solar neighborhood. From the fitting of the K-band luminosity function (KLF), the age and distance of the S207 cluster are estimated at 2–3 Myr and ∼4 kpc, respectively. The estimated age is consistent with the suggestion of small extinctions of stars in the cluster (A{sub V} ∼ 3 mag) and the non-detection of molecular clouds. The reasonably good fit between the observed KLF and the model KLF suggests that the underlying initial mass function (IMF) of the cluster down to the detection limit is not significantly different from the typical IMFs in the solar metallicity. From the fraction of stars with NIR excesses, a low disk fraction (<10%) in the cluster with a relatively young age is suggested, as we had previously proposed.

79 ASTRONOMY AND ASTROPHYSICS↗

An elastography method based on the scanning contact resonance of a piezoelectric cantilever

Purpose: Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. Methods: This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which the sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Results: Testing onin vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method/system is better than 0.5 mm, and could be further enhanced by using more scanning points. Conclusions: The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-Closure Environmental Sampling and Inspection at the Amchitka Island, Alaska, Site - 17251

In the 1960's and early 1970's, three underground nuclear tests were conducted on Amchitka Island, Alaska. In 1965, the US Department of Defense-in conjunction with the US Atomic Energy Commission (AEC)-conducted the first of these nuclear tests, Long Shot, to provide data that would improve US capabilities for detecting underground nuclear explosions. In 1969, AEC conducted the second test, Milrow, to explore the feasibility of detonating a much larger device. In 1971, AEC conducted the third test, Cannikin, which was the largest underground test ever conducted by the US. The Long-Term Surveillance Plan (LTSP) for the Amchitka, Alaska, Site details how the US Department of Energy Office of Legacy Management (LM) intends to fulfill its mission to protect human health and the environment at and around the Amchitka Island site. The LTSP calls for monitoring to be performed every 5 years, at least during the initial phase of the project. The purpose of the monitoring is to develop a baseline of activity concentrations for selected radionuclides in biota, water, and soil, both on Amchitka Island and at the reference location on Adak Island, approximately 322 kilometers (200 miles) northeast of Amchitka. In addition to the environmental monitoring activities, seven mud pit caps that contain diesel-contaminated soils are inspected. The plan for biological and water sampling (both seawater and freshwater) during the May 2016 sampling event was developed through close coordination with the primary stakeholders, including the Alaska Department of Environmental Conservation, the Aleutian Pribilof Islands Association, and the US Fish and Wildlife Service. The environmental sampling in 2016 is a continuation of LM's evaluation of Amchitka Island's environment. Previous results from similar monitoring programs in 2004 and 2011 indicate that the environment is not being impacted by radionuclide migration and uptake from the underground nuclear testing conducted beneath Amchitka Island; consequently, subsistence and commercial-catch seafood is safe for human consumption. The collection of biota samples (rockfish, Irish lords, greenling, and rockweed) for cesium-134 ({sup 134}Cs), cesium-137 ({sup 137}Cs), plutonium-239 ({sup 239}Pu), plutonium-240 ({sup 240}Pu), and freshwater and seawater samples for {sup 134}Cs, {sup 137}Cs, and tritium ({sup 3}H) was the primary objective of the 2016 sampling effort. Rockfish, Irish lords, and greenling are resident, nonmigratory fish species that spend their entire life cycle in the marine environment, and rockweed is an inter-tidal species that may concentrate cesium. The seawater samples were collected primarily to determine if leakage from the Long Shot detonation could be detected and, secondarily, to compare with the background seawater samples collected from Adak Island. Cesium isotopes are also being analyzed to better understand the potential impact that the Fukushima-Daiichi release might have on the Amchitka and Adak environments. The target detection limits used for the 2016 sampling are lower than those used in previous studies. The lower detection limits make it possible for LM to delineate background activity levels for the radionuclides of interest. Data from the 2016 sampling event go beyond assessing food safety and focus on detecting leakage from the underground nuclear explosions. Additionally, the baseline activity concentrations obtained for the reference area (Adak Island) will enable identification of quantitative statistical trends in the results of future sampling programs. Sampling programs conducted in 2021 and beyond will have an objective to assess the statistical trends of radioactivity levels in the Amchitka Island environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Fourth Quarter 2012 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

This report details the chemical and radionuclide contaminant results for the characterization of the 2012 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).1 Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: The concentration of the reported chemical and radioactive contaminants were less than their respective WAC Limits and Targets, unless noted in this section. Norpar 13 and Isopar L have higher detection limits 5 compared with the Saltstone WAC 1 . The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility in aqueous solution, may not represent the concentrations of the analytes in Tank 50. Diisooctyl adipate (or diisooctyl hexanedioate) was measured at 1.30E+00 mg/L in one of two replicate measurements conducted on an at-depth sample. a The organic analysis of the at-depth sample was conducted at the request of SRR. 4 This analyte was below the detection limit in the surface sample. The low insoluble solids content increases the measurement uncertainty for insoluble species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A statistical analysis of gamma-ray bursts detected by the Konus Experiment on Venera 11 and 12

We discuss the advantages of using the V/V sub max method to test well-defined samples of gamma-ray bursts for the spatial uniformity of their parent population. We have applied the V/V sub max test to gamma ray bursts of duration longer than 1 second recorded by the Konus experiment aboard Venera 11 and 12. Based on a sample of 123 bursts, we find V/V sub max equals 0.46 plus or minus 0.03, consistent with a uniform distribution in space. We urge that experimenters give careful attention to the detection limit for each recorded gamma ray burst, and that quantitative data for burst properties and detection limits be published.

Schmidt, Maarten↗

Improved performance comparisons of radioxenon systems for low level releases in nuclear explosion monitoring

The Comprehensive Nuclear-Test-Ban Treaty bans all nuclear tests and mandates development of verification measures to detect treaty violations. One verification measure is detection of radioactive xenon isotopes produced in the fission of actinides. The International Monitoring System (IMS) currently deploys automated radioxenon systems that can detect four radioxenon isotopes. Radioxenon systems with lower detection limits are currently in development. Historically, the sensitivity of radioxenon systems was measured by the minimum detectable concentration for each isotope. In this paper we analyze the response of radioxenon systems using rigorous metrics in conjunction with hypothetical representative releases indicative of an underground nuclear explosion instead of using only minimum detectable concentrations. Our analyses incorporate the impact of potential spectral interferences on detection limits and the importance of measuring isotopic ratios of the relevant radioxenon isotopes in order to improve discrimination from background sources particularly for low-level releases. To provide a sufficient data set for analysis, hypothetical representative releases are simulated every day from the same location for an entire year. The performance of three types of samplers are evaluated assuming they are located at 15 IMS radionuclide stations in the region of the release point. The performance of two IMS-deployed samplers and a next-generation system is compared with proposed metrics for detection and discrimination using representative releases from the nuclear test site used by the Democratic People’s Republic of Korea.

Haas, Derek A.↗

A Novel Approach for the Simultaneous Determination of Iodide, Iodate and Organo-Iodide for 127 I and 129 I in Environmental Samples Using Gas Chromatography-Mass Spectrometry

In aquatic environments, iodine mainly exists as iodide, iodate, and organic iodine. The high mobility of iodine in aquatic systems has led to 129 I contamination problems at sites where nuclear fuel has been reprocessed, such as the F-area of Savannah River Site. In order to assess the distribution of 129 I and stable 127 I in environmental systems, a sensitive and rapid method was developed which enables determination of isotopic ratios of speciated iodine. Iodide concentrations were quantified using gas chromatography-mass spectrometry (GC-MS) after derivatization to 4-iodo-N,N-dimethylaniline. Iodate concentrations were quantified by measuring the difference of iodide concentrations in the solution before and after reduction by Na 2 S 2 O 5 . Total iodine, including inorganic and organic iodine, was determined after conversion to iodate by combustion at 900 °C. Organo-iodine was calculated as the difference between the total iodine and total inorganic iodine (iodide and iodate). The detection limits of iodide-127 and iodate-127 were 0.34 nM and 1.11 nM, respectively, whereas the detection limits for both iodide-129 and iodate-129 was 0.08 nM (i.e., 2pCi 129 I/L). This method was successfully applied to water samples from the contaminated Savannah River Site, South Carolina, and more pristine Galveston Bay, Texas.

Zhang, S.↗