Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Theoretical study of neutrino-induced coherent pion production off nuclei at T2K and MiniBooNE energies

We have developed a model for neutrino-induced coherent pion production off nuclei in the energy regime of interest for present and forthcoming neutrino oscillation experiments. It is based on a microscopic model for pion production off the nucleon that, besides the dominant {delta} pole contribution, takes into account the effect of background terms required by chiral symmetry. Moreover, the model uses a reduced nucleon-to-{delta} resonance axial coupling, which leads to coherent pion production cross sections around a factor of 2 smaller than most of the previous theoretical estimates. In the coherent production, the main nuclear effects, namely, medium corrections on the {delta} propagator and the final pion distortion, are included. We have improved on previous similar models by taking into account the nucleon motion and employing a more sophisticated optical potential. As found in previous calculations the modification of the {delta} self-energy inside the nuclear medium strongly reduces the cross section, while the final pion distortion mainly shifts the peak position to lower pion energies. The angular distribution profiles are not much affected by nuclear effects. Nucleon motion increases the cross section by {approx}15% at neutrino energies of 650 MeV, while Coulomb effects on charged pions are estimated to be small. Finally, we discuss at length the deficiencies of the Rein-Sehgal pion coherent production model for neutrino energies below 2 GeV, and, in particular, for the MiniBooNE and T2K experiments. We also predict flux-averaged cross sections for these two latter experiments and K2K.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lensing corrections to features in the angular two-point correlation function and power spectrum

It is well known that magnification bias, the modulation of galaxy or quasar source counts by gravitational lensing, can change the observed angular correlation function. We investigate magnification-induced changes to the shape of the observed correlation function w({theta}), and the angular power spectrum C{sub l}, paying special attention to the matter-radiation equality peak and the baryon wiggles. Lensing effectively mixes the correlation function of the source galaxies with that of the matter correlation at the lower redshifts of the lenses distorting the observed correlation function. We quantify how the lensing corrections depend on the width of the selection function, the galaxy bias b, and the number count slope s. The lensing correction increases with redshift and larger corrections are present for sources with steep number count slopes and/or broad redshift distributions. The most drastic changes to C{sub l} occur for measurements at high redshifts (z > or approx. 1.5) and low multipole moment (l < or approx. 100). For the source distributions we consider, magnification bias can shift the location of the matter-radiation equality scale by 1%-6% at z{approx}1.5 and by z{approx}3.5 the shift can be as large as 30%. The baryon bump in {theta}{sup 2}w({theta}) is shifted by < or approx. 1% and the width is typically increased by {approx}10%. Shifts of > or approx. 0.5% and broadening > or approx. 20% occur only for very broad selection functions and/or galaxies with (5s-2)/b > or approx. 2. However, near the baryon bump the magnification correction is not constant but is a gently varying function which depends on the source population. Depending on how the w({theta}) data is fitted, this correction may need to be accounted for when using the baryon acoustic scale for precision cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TESTING GRAVITY USING THE GROWTH OF LARGE-SCALE STRUCTURE IN THE UNIVERSE

Future galaxy surveys hope to distinguish between the dark energy and modified gravity scenarios for the accelerating expansion of the universe using the distortion of clustering in redshift space. The aim is to model the form and size of the distortion to infer the rate at which large-scale structure grows. We test this hypothesis and assess the performance of current theoretical models for the redshift space distortion using large volume N-body simulations of the gravitational instability process. We simulate competing cosmological models which have identical expansion histories-one is a quintessence dark energy model with a scalar field and the other is a modified gravity model with a time-varying gravitational constant-and demonstrate that they do indeed produce different redshift space distortions. This is the first time that this approach has been verified using a technique that can follow the growth of structure at the required level of accuracy. Our comparisons show that theoretical models for the redshift space distortion based on linear perturbation theory give a surprisingly poor description of the simulation results. Furthermore, the application of such models can give rise to catastrophic systematic errors leading to incorrect interpretation of the observations. We show that an improved model is able to extract the correct growth rate. Further enhancements to theoretical models of redshift space distortions, calibrated against simulations, are needed to fully exploit the forthcoming high-precision clustering measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of light scattering on biological tissue thermometry from photoluminescence spectra of up-conversion nanoparticles

Photoluminescence spectra of the up-conversion nanoparticles NaYF{sub 4} : Y{sup 3+}, Er{sup 3+} arranged under a layer of an adipose tissue have been recorded in a wide temperature range. It is shown that if nanoparticle temperature is determined from the photoluminescence spectra, an error arises related to spectrum distortion due to light scattering in a sample. A correction algorithm for reducing this error is developed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPECTER: an instrument concept for CMB spectral distortion measurements with enhanced sensitivity

Deviations of the cosmic microwave background (CMB) energy spectrum from a perfect blackbody uniquely probe a wide range of physics, ranging from fundamental physics in the primordial Universe (μ-distortion) to late-time baryonic feedback processes (y-distortion). While the y-distortion can be detected with a moderate increase in sensitivity over that of COBE/FIRAS, the ΛCDM-predicted μ-distortion is roughly two orders of magnitude smaller and requires substantial improvements, with foregrounds presenting a serious obstacle. Within the standard model, the dominant contribution to μ arises from energy injected via Silk damping, yielding sensitivity to the primordial power spectrum at wavenumbers k ≈ 1-10 4 Mpc -1 . Here, we present a new instrument concept, SPECTER, with the goal of robustly detecting μ. The instrument technology is similar to that of LiteBIRD, but with an absolute temperature calibration system. Using a Fisher approach, we optimize the instrument's configuration to target μ while marginalizing over foreground contaminants. Unlike Fourier-transform-spectrometer-based designs, the specific bands and their individual sensitivities can be independently set in this instrument, allowing significant flexibility. We forecast SPECTER to observe the ΛCDM-predicted μ-distortion at ≈ 5σ (10σ) assuming an observation time of 1 (4) year(s) (corresponding to mission duration of 2 (8) years), after foreground marginalization. Our optimized configuration includes 16 bands spanning 1–2000 GHz with ∼degree-scale angular resolution at ∼ 150 GHz and 1100 total detectors. SPECTER will additionally measure the y-distortion at sub-percent precision and its relativistic correction at percent-level precision, yielding tight constraints on the total thermal energy and mean temperature of ionized gas.

CMBR experiments↗

Orbit correction in a linear nonscaling fixed field alternating gradient accelerator

In a linear non-scaling FFAG the large natural chromaticity of the machine results in a betatron tune that varies by several integers over the momentum range. In addition, orbit correction is complicated by the consequent variation of the phase advance between lattice elements. Here we investigate how the correction of multiple closed orbit harmonics allows correction of both the COD and the accelerated orbit distortion over the momentum range.

43 PARTICLE ACCELERATORS↗

X-ray spectral measurements for tungsten-anode from 20 to 49 kVp on a digital breast tomosynthesis system

Purpose: This paper presents new spectral measurements of a tungsten-target digital breast tomosynthesis (DBT) system, including spectra of 43-49 kVp. Methods: Raw x-ray spectra of 20-49 kVp were directly measured from the tube port of a Selenia Dimensions DBT system using a CdTe based spectrometer. Two configurations of collimation were employed: one with two tungsten pinholes of 25{mu}m and 200{mu}m diameters, and the other with a single pinhole of 25{mu}m diameter, for acquiring spectra from the focal spot and from the focal spot as well as its vicinity. Stripping correction was applied to the measured spectra to compensate distortions due to escape events. The measured spectra were compared with the existing mammographic spectra of the TASMIP model in terms of photon fluence per exposure, spectral components, and half-value layer (HVL). HVLs were calculated from the spectra with a numerical filtration of 0.7 mm aluminum and were compared against actual measurements on the DBT system using W/Al (target-filter) combination, without paddle in the beam. Results: The spectra from the double-pinhole configuration, in which the acceptance aperture pointed right at the focal spot, were harder than the single-pinhole spectra which include both primary and off-focus radiation. HVL calculated from the single-pinhole setup agreed with the measured HVL within 0.04 mm aluminum, while the HVL values from the double-pinhole setup were larger than the single-pinhole HVL by at most 0.1 mm aluminum. The spectra from single-pinhole setup agreed well with the TASMIP mammographic spectra, and are more relevant for clinical purpose. Conclusions: The spectra data would be useful for future research on DBT system with tungsten targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography

Purpose: An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. Methods: Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. Results: By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. Conclusions: The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity.

60 APPLIED LIFE SCIENCES↗

Analysis of Crystal Lattice Deformation by Ion Channeling

A model of dislocations has been developed for the use in Monte Carlo simulations of ion channeling spectra obtained for defected crystals. High resolution transmission electron microscopy micrographs show that the dominant type of defects in the majority of ion irradiated crystals are dislocations. The RBS/channeling spectrum is then composed of two components: one is due to direct scattering on randomly displaced atoms and the second one is related to beam defocussing on dislocations, which produce predominantly crystal lattice distortions, i.e. bent channels. In order to provide a correct analysis of backscattering spectra for the crystals containing dislocations we have modified the existing Monte Carlo simulation code "McChasy". A new version of the code has been developed by implementing dislocations on the basis of the Peierls-Nabarro model. Parameters of the model have been determined from the high resolution transmission electron microscopy data. The newly developed method has been used to study the Ar-ion bombarded SrTiO3 samples. The best fit to the Rutherford backscattering/channeling spectra has been obtained by optimizing the linear combination of two kinds of defects: displaced atoms and bent channels. The great virtue of the Monte Carlo simulation is that unlike a traditional dechanneling analysis it allows quantitative analysis of crystals containing a mixture of different types of defects.

Environmental Molecular Sciences Laboratory↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗

First polarized proton collision at a beam energy of 250 GeV in RHIC

After providing collisions of polarized protons at a beam energy of 100 GeV since 2001, the Relativistic Heavy Ion Collider (RHIC) at BNL had its first opportunity to collide polarized protons at its maximum beam energy of 250 GeV in the 2009 polarized proton operations. Equipped with two full Siberian snakes [1] in each ring, RHIC preserves polarization during acceleration from injection to 100 GeV with precise control of the betatron tunes and vertical orbit distortions. However, the strong intrinsic spin resonances beyond 100 GeV are more than two times stronger than those below 100 GeV, requiring much tighter tolerances on vertical orbit distortions and betatron tunes. With the currently achieved orbit correction and tune control, average polarizations of {approx_equal} 42% at top energy and average polarizations of {approx_equal} 55% at injection energy were achieved. Polarization measurements as a function of beam energy also indicated aU polarization losses occurred around three strong intrinsic resonances at 136 GeV, 199.3 GeV and 220.8 GeV Peak luminosity of 122 x 10{sup 30} cm{sup -2} s{sup -1} was also demonstrated. This paper presents the performance of the first RHIC 250 GeV operation and discusses the depolarization issues encountered during the run.

43 PARTICLE ACCELERATORS↗

Influence of Light Atoms on Quantification of Atomic Column Positions in Distorted Perovskites with HAADF-STEM

Measurement of picometer-scale atomic displacements by aberration-corrected STEM has become invaluable in the study of crystalline materials, where it can elucidate ordering mechanisms and local heterogeneities. HAADF-STEM imaging, often used for such measurements due to its atomic number contrast, is generally considered insensitive to light atoms such as oxygen. Light atoms, however, still affect the propagation of the electron beam in the sample and, therefore, the collected signal. In this work, we demonstrate experimentally and through simulations that cation sites in distorted perovskites can appear to be displaced by several picometers from their true positions in shared cation-anion columns. The effect can be decreased through careful choice of sample thickness and beam voltage or can be entirely avoided if the experiment allows reorientation of the crystal along a more favorable zone axis. Therefore, it is crucial to consider the possible effects of light atoms and crystal symmetry and orientation when measuring atomic positions.

36 MATERIALS SCIENCE↗

Spatial Mode Correction of Single Photons Using Machine Learning

Abstract Spatial modes of light constitute valuable resources for a variety of quantum technologies ranging from quantum communication and quantum imaging to remote sensing. Nevertheless, their vulnerabilities to phase distortions, induced by random media, impose significant limitations on the realistic implementation of numerous quantum‐photonic technologies. Unfortunately, this problem is exacerbated at the single‐photon level. Over the last two decades, this challenging problem has been tackled through conventional schemes that utilize optical nonlinearities, quantum correlations, and adaptive optics. In this article, the self‐learning and self‐evolving features of artificial neural networks are exploited to correct the complex spatial profile of distorted Laguerre–Gaussian modes at the single‐photon level. Furthermore, the potential of this technique is used to improve the channel capacity of an optical communication protocol that relies on structured single photons. The results have important implications for real‐time turbulence correction of structured photons and single‐photon images.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DIFFICULTY IN THE FORMATION OF COUNTER-ORBITING HOT JUPITERS FROM NEAR-COPLANAR HIERARCHICAL TRIPLE SYSTEMS: A SUB-STELLAR PERTURBER

Among 100 transiting planets with a measured projected spin–orbit angle λ, several systems are suggested to be counter-orbiting. While these cases may be due to the projection effect, the mechanism that produces a counter-orbiting planet has not been established. A promising scenario for counter-orbiting planets is the extreme eccentricity evolution in near-coplanar hierarchical triple systems with eccentric inner and outer orbits. We examine this scenario in detail by performing a series of systematic numerical simulations, and consider the possibility of forming hot Jupiters (HJs), especially a counter-orbiting one under this mechanism with a distant sub-stellar perturber. We incorporate quadrupole and octupole secular gravitational interaction between the two orbits, and also short-range forces (correction for general relativity, star and inner planetary tide, and rotational distortion) simultaneously. We find that most systems are tidally disrupted and that a small fraction of the surviving planets turn out to be prograde. The formation of counter-orbiting HJs in this scenario is possible only in a very restricted parameter region, and thus is very unlikely in practice.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, the energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can be verified or even determined by measurement in a water phantom and comparison with dose distributions calculated using the TG43 dosimetry formalism. Project is supported by DIN Deutsches Institut fuer Normung.

60 APPLIED LIFE SCIENCES↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

Implications for Damage Recognition during Dpo4-Mediated Mutagenic Bypass of m1G and m3C Lesions

DNA is susceptible to alkylation damage by a number of environmental agents that modify the Watson-Crick edge of the bases. Such lesions, if not repaired, may be bypassed by Y-family DNA polymerases. The bypass polymerase Dpo4 is strongly inhibited by 1-methylguanine (m1G) and 3-methylcytosine (m3C), with nucleotide incorporation opposite these lesions being predominantly mutagenic. Further, extension after insertion of both correct and incorrect bases, introduces additional base substitution and deletion errors. Crystal structures of the Dpo4 ternary extension complexes with correct and mismatched 3'-terminal primer bases opposite the lesions reveal that both m1G and m3C remain positioned within the DNA template/primer helix. However, both correct and incorrect pairing partners exhibit pronounced primer terminal nucleotide distortion, being primarily evicted from the DNA helix when opposite m1G or misaligned when pairing with m3C. Our studies provide insights into mechanisms related to hindered and mutagenic bypass of methylated lesions and models associated with damage recognition by repair demethylases.

59 BASIC BIOLOGICAL SCIENCES↗