Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Direct Measurement of Mass-Temperature Distributions in the Core of Implosions on the National Ignition Facility (Full Technical Final Report)

Inertial confinement fusion plasmas are characterized by several kilo-electron-volt (keV) electron temperatures and ion and electron densities approaching 100 to 1000 times solid. In these implosions which simulate the dynamics of our sun, spectroscopic dopants can lead to detailed exploration of the plasma gradients that are not possible in other places. This is both in the central core pressure and temperature as well as any “mix” resultant from ablation and hydrodynamic interactions. This work will show new Bayesian atomic physics models applied to ICF plasmas to give both the temperature and density of the internal hot spot to better describe the physical nature of these implosions along with trying to spatially resolve the mix coming from the ablator region. The mission impact is to demonstrate this effect and to lead to a more quantitative description of mix in inertial confinement plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature distributions and thermal stresses in a graded zirconia/metal gas path seal system for aircraft gas turbine engines

A ceramic/metallic aircraft gas turbine outer gas path seal designed for improved engine performance was studied. Transient temperature and stress profiles in a test seal geometry were determined by numerical analysis. During a simulated engine deceleration cycle from sea-level takeoff to idle conditions, the maximum seal temperature occurred below the seal surface, therefore the top layer of the seal was probably subjected to tensile stresses exceeding the modulus of rupture. In the stress analysis both two- and three-dimensional finite element computer programs were used. Predicted trends of the simpler and more easily usable two-dimensional element programs were borne out by the three-dimensional finite element program results.

Taylor, C. M.↗

Effect of Modified Thermal Conductivity on the Temperature Distribution in the Protonosphere

At typical protonospheric electron densities, the electron mean free path is long enough that the coefficient of thermal conductivity is no longer given by Spitzer's expression. The effect on the temperature profile of using the corrected expression for conductivity is investigated. The corrected thermal conduction coefficient is density-dependent and has a more complicated temperature dependence than the coefficient applicable to higher density plasmas. The results indicate that the effect is not negligible even under quiet conditions and at low latitudes.

Mayr, H. G.↗

Spatial and temporal temperature distribution optimization for a geostationary antenna

The Geostationary Microwave Precipitation Radiometer antenna is considered and a thermal design analysis is performed to determine a design that would minimize on-orbit antenna temporal and spatial temperature gradients. The final design is based on an optically opaque radome which covered the antenna. The average orbital antenna temperature is found to be 9 C with maximum temporal and spatial variations of 34 C and 1 C, respectively. An independent thermal distortion analysis showed that this temporal variation would give an antenna figure error of 14 microns.

Tsuyuki, G.↗

Effect of modified thermal conductivity on the temperature distribution in the protonosphere.

At typical protonospheric electron densities the electron mean free path is sufficiently long so that the coefficient of thermal conductivity is no longer given by Spitzer's expression. The effect on the temperature profile of using the corrected expression for conductivity is investigated. The corrected thermal conduction coefficient is density-dependent and has a more complicated temperature dependence than the coefficient applicable to higher density plasmas. The results indicate that the effect is not negligible even under quiet conditions and at low latitudes.

Mayr, H. G.↗

The Atacama Cosmology Telescope: A Measurement of the Thermal Sunyaev-Zel'dovich Effect Using the Skewness of the CMB Temperature Distribution

We present a detection of the unnormalized skewness (T(sup ~)(sup 2)(n(circumflex)) induced by the thermal Sunyaev-Zel'dovich (tSZ) effect in filtered Atacama Cosmology Telescope (ACT) 148 GHz cosmic microwave background temperature maps. Contamination due to infrared and radio sources is minimized by template subtraction of resolved sources and by constructing a mask using outlying values in the 218 GHz (tSZ-null) ACT maps. We measure (T(sup ~)(sup 3) (n(circumflex)) = -31 plus or minus 6 micro-K(sup 3) (measurement error only) or plus or minus 14 micro-K(sup 3) (including cosmic variance error) in the filtered ACT data, a 5sigma detection. We show that the skewness is a sensitive probe of sigma(sub 8), and use analytic calculations and tSZ simulations to obtain cosmological constraints from this measurement. From this signal alone we infer a value of sigma(sub 8) = 0.78 sup +0.03 sub -0.04 (68% C.L.) sup +0.05 sub -0.16. Our results demonstrate that measurements of nonGaussianity can be a useful method for characterizing the tSZ effect and extracting the underlying cosmological information.

Wilson, Michael J.↗

High Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors [Slides]

All objectives have been completed. Heated irradiation indicates potential for sapphire fiber-based sensors to be used in extreme environments beyond silica fiber temperature limits. Sapphire optical fiber may not be appropriate for high fluence applications. Clad sapphire optical fibers have a temperature-dependent attenuation that has not been observed in unclad sapphire. With the appropriate pre-treatments and data post-processing, sapphire optical fiber has the potential to serve as a distributed sensor up to 1700ºC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient temperature distributions in simple conducting bodies steadily heated through a laminar boundary layer

An analysis is made of the transient heat-conduction effects in three simple semi-infinite bodies: the flat insulated plate, the conical shell, and the slender solid cone. The bodies are assumed to have constant initial temperatures and, at zero time, to begin to move at a constant speed and zero angle of attack through a homogeneous atmosphere. The heat input is taken as that through a laminar boundary layer. Radiation heat transfer and transverse temperature gradients are assumed to be zero. The appropriate heat-conduction equations are solved by an iteration method, the zeroeth-order terms describing the situation in the limit of small time. The method is presented and the solutions are calculated to three orders which are sufficient to give reasonably accurate results when the forward edge has attained one-half the total temperature rise (nose half-rise time). Flight Mach number and air properties occur as parameters in the result. Approximate expressions for the extent of the conduction region and nose half-rise times as functions of the parameters of the problem are presented. (author)

Parker, Hermon M↗

On the temperature distribution in a planetary atmosphere.

Criteria for the appearance of a double maximum in the absorption spectra are derived. A very oversimplified model atmosphere which consists of two isothermal layers of gas is considered. The model involves the presence of two absorption cells in series, in front of a light source that has a higher temperature than either of the cells. The possibility that the double maximum is due to a quantum-mechanical interaction is studied. It is concluded that the effect reported by Kaplan (1962) was due to noise, and that it is impossible to detect temperatures as high as 700 K in the atmosphere of Venus by means of ground-based observations of the 7820 A carbon dioxide band.

Young, L. D. G.↗

Time dependent shear stress and temperature distribution over an insulated flat plate moving at hypersonic speed.

The laminar two-dimensional flow over a stepwise accelerated flat plate moving with hypersonic speed at zero angle of attack is analysed. The governing equations in the self-similar form are linearized and solved numerically for small times. The solutions obtained are the deviations of the velocity and the temperature profiles from those of steady state. The presented results may be used to find the first order boundary layer induced pressure on the plate.

Rodkiewicz, C. M.↗

Temperature distribution in a laser-heated diamond anvil cell as described by finite element analysis

Finite element analysis (FEA) is a powerful tool for numerically solving partial differential equations over complex geometries and is thus useful for analyzing heat transport in laser-heated diamond anvil cell (LHDAC) experiments. Our models expand on previously published simulations by calculating the volume-averaged temperatures of both the sample and insulation/pressure media under steady-state heating to determine the thermal pressure of the hot sample. Our goal is to produce an accurate relationship between the measured surface temperature of the absorbing sample and the temperature of the transparent insulating media, which is used to determine thermal pressure but susceptible to steep temperature gradients. We find that in doing so, our FEA models of temperature within the pressure/insulation media can differ from simplified estimates of temperature gradients by more than a factor of 2. We also explore temperature-dependent and temperature-independent thermal conductivity models and find that the volume-averaged temperatures differ by up to a factor of 1.3, forcing the predicted thermal pressures determined to also differ by up to a factor of 1.5 at a temperature of 2000 K at 50 GPa for neon. Higher temperatures exacerbate this difference. We also find that unintentional asymmetric sample insertion and sample heating, which are common in LHDAC experiments, do not have a first-order effect on volume-averaged temperatures. The FEA models, available in both Python and FlexPDE, are versatile across different sample geometries, materials, and heat source laser shapes.

Farah, Frederick↗

Impact of molten salt inflow on the temperature distribution in thermal energy storage tanks at startup for central receiver concentrating solar power plants

Concentrating Solar Power (CSP) systems with molten salt thermal energy storage (TES) tanks are one of the most promising, renewable-based energy conversion technologies for larger-scale power generation. The TES tank is one of the most critical components in CSP plants due to its high-temperature operation (up to 565 °C), daily thermal cycling, and intermittent solar radiation conditions. The plant startup is one of the most challenging operation conditions that could lead to damaging thermal gradients due to low salt inventory levels. In this study an analytical model for the sparger ring was developed and integrated with a detailed computational fluid dynamics model of a commercial-scaled molten salt tank. The integrated model allows an accurate representation of the tank operation to evaluate the effect of molten salt inflow on the mixing process. The tank filling process during plant startup was analyzed considering sparger rings with variations in design features, including inlet orifice configurations, number of orifices, direction of the inlets, and orifice diameter. The results demonstrated that higher temperature gradients are obtained in the tank floor during the plant startup. A sparger ring configuration with a predetermined orifice inlet inclination (30°, 45° and 60°) leads to significant temperature differences in the floor, between 57 °C and 62 °C, but better homogeneity in the temperature of the salt inventory. Lower salt inflow velocities result in a more homogeneous floor temperature, with maximum temperature differences under 38 °C. The sparger ring configuration with 52 orifices of 1-in. diameter and vertical flow showed better homogeneity in the temperature differences as a function of the salt level and lower temperature gradients in the tank floor. Because large temperature gradients in the tank's floor have been identified as one of the main factors contributing to tank failures, assessing various sparger ring design features is fundamental to determining proper inflow conditions that lead to low-temperature gradients and reducing failure susceptibility.

14 SOLAR ENERGY↗

Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

Johnsen, R. L.↗

Simulation of the temperature distribution in crystals grown by Czochralski method

Production of perfect crystals, free of residual strain and dislocations and with prescribed dopant concentration, by the Czochralski method is possible only if the complex, interacting phenomena that affect crystal growth in a Cz-puller are fully understood and quantified. Natural and forced convection in the melt, thermocapillary effect and heat transfer in and around the crystal affect its growth rate, the shape of the crystal-melt interface and the temperature gradients in the crystal. The heat transfer problem in the crystal and between the crystal and all other surfaces present in the crystal pulling apparatus are discussed at length. A simulation and computer algorithm are used, based on the following assumptions: (1) only conduction occurs in the crystal (experimentally determined conductivity as a function of temperature is used), (2) melt temperature and the melt-crystal heat transfer coefficient are available (either as constant values or functions of radial position), (3) pseudo-steady state is achieved with respect to temperature gradients, (4) crystal radius is fixed, and (5) both direct and reflected radiation exchange occurs among all surfaces at various temperatures in the crystal puller enclosure.

Dudokovic, M. P.↗

Temperature distribution of a hot water storage tank in a simulated solar heating and cooling system

A 2,300-liter hot water storage tank was studied under conditions simulating a solar heating and cooling system. The initial condition of the tank, ranging from 37 C at the bottom to 94 C at the top, represented a condition midway through the start-up period of the system. During the five-day test period, the water in the tank gradually rose in temperature but in a manner that diminished its temperature stratification. Stratification was found not to be an important factor in the operation of the particular solar system studied.

Namkoong, D.↗

Steady state and transient temperature distributions in the human thigh covered with a cooling pad

An analytical and experimental study was done on the performance of cooling pads attached to a human thigh. Each cooling pad consisted of a long, water cooled tube formed into a serpentine shape with uniform spacing between the parallel sections. The analytical work developed a cylindrical model for the human thigh. The transient times predicted by this model ranged from 25 to 80 minutes, which is reasonably close to the experimental results. Calculated and measured steady state temperature profiles were in fair agreement. The transient times associated with a change from a high metabolic rate of 1800 Btu/hr (528 w) to a low level of 300 Btu/hr (88 w), were found to be about 120 minutes. A change from 300 Btu/hr (264 w) to 300 Btu/hr (88 w) resulted in 90 to 100 minute transients. However, the transient times for a change in metabolic rate in the opposite direction from 300 Btu/hr (88 w) to 1800 Btu/hr (528 w) were 40 to 60 minutes.

Leo, R. J.↗