Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Coupled neutronic-thermal-hydraulic simulations of the European SFR core

Within the European SFR (Sodium-cooled Fast Reactor) - Safety Measures Assessment and Research Tools (ESFR-SMART) project, steady-state coupled simulation of the ESFR core has been performed using several core analysis packages, with the objective of quantifying the coupling effect. Focus is on the fuel Doppler effect and coolant expansion effect. Standalone neutronics calculations in TRACE/PARCS (PSI), DYN3D (HZDR) and WIMS (Jacobs) showed superb agreement with the reference Serpent power distribution (root mean square - rms discrepancies of 1.3%, 1.5% and 0.7% respectively). Results for COUNTHER (CIEMAT) were also in reasonable agreement, but with a somewhat higher discrepancy of 3.7%. Temperature distributions from thermal-hydraulic calculations were also compared and are found to be in good agreement. The effect of Doppler and coolant density feedback on core power distribution was predicted by TRACE/PARCS, DYN3D and WIMS to be between 0.4% and 0.8% rms difference in assembly powers. Reactivity coefficients for perturbations in the inlet temperature, flow rate and core power were shown to be negative for these three codes, with values of roughly -0.5 pcm/C. degree, -0.3 pcm/C. degree and -3.5 pcm/C. degree respectively. A preliminary investigation of differential thermal expansion effects indicates that this may have a significant effect on core power distribution of a few %, greater than anticipated a priori and may warrant inclusion in coupled core analysis to ensure the accurate calculation of power distributions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Underpotential lithium plating on graphite anodes caused by temperature heterogeneity

Rechargeability and operational safety of commercial lithium (Li)-ion batteries demand further improvement. Plating of metallic Li on graphite anodes is a critical reason for Li-ion battery capacity decay and short circuit. It is generally believed that Li plating is caused by the slow kinetics of graphite intercalation, but in this paper, we demonstrate that thermodynamics also serves a crucial role. We show that a nonuniform temperature distribution within the battery can make local plating of Li above 0 V vs. Li 0 /Li + (room temperature) thermodynamically favorable. This phenomenon is caused by temperature-dependent shifts of the equilibrium potential of Li 0 /Li + . Supported by simulation results, we confirm the likelihood of this failure mechanism during commercial Li-ion battery operation, including both slow and fast charging conditions. This work furthers the understanding of nonuniform Li plating and will inspire future studies to prolong the cycling lifetime of Li-ion batteries.

25 ENERGY STORAGE↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗

Investigation of CAD-based Geometry Workflows for Multiphysics Fusion Problems Using OpenMC and MOOSE

Fusion system designs are complex and require intricate and accurate meshes to be properly modeled. In this study, we investigate the use of CAD-based geometry workflows in fusion systems multiphysics problems. A simplified tokamak was introduced and modeled in CAD using a multiphysics coupling of OpenMC Monte Carlo transport and MOOSE heat conduction. The meshed geometry was prepared using direct accelerated geometry Monte Carlo (DAGMC) for particle transport, and a volumetric mesh was also prepared to be used in MOOSE and to tally OpenMC results. Cardinal was used to run OpenMC Monte Carlo particle transport within MOOSE framework. The heat source distribution and tritium production were calculated in OpenMC. The data transfer system was used to transfer heat source and temperature distribution between OpenMC and MOOSE. Two computational studies related to mesh refinement were performed: (1) refining the DAGMC and volumetric meshes used for tallying results and solving heat conduction and (2) only refining the DAGMC particle transport mesh. The refinement of the tally mesh has a much larger effect on the runtime compared to the refinement of the DAGMC particle transport surface mesh.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

In the pursuit of more efficient gas turbines, film cooling is a critical technology. This article describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to relate film-cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. Here, this article presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film-cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This article is relevant to conjugate test rigs that can measure the hot-surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced turbines↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

This paper describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to develop a new method to relate film cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. This paper presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained, and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This paper is relevant to conjugate test rigs that can measure the hot surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced gas turbines↗

The Influence of Temperature Inversion on the Vertical Distribution of Aerosols

Temperature inversion plays an important role in the accumulation and diffusion of aerosols. In this study, the relationship between temperature inversion and the vertical distribution of aerosols is investigated based on Raman lidar observations taken from January 2010 to September 2015 at the Atmospheric Radiation Measurement site in the Southern Great Plains, USA. First, the diurnal and seasonal variations of the surface-based inversion (SBI) and elevated temperature inversion (EI) are investigated. The results indicate that the occurrence frequency of SBI and EI have different seasonal trends. SBI has the highest frequency in summer, while EI has the highest frequency in winter. The diurnal variation of SBI is obvious, with a higher frequency in nighttime and a lower frequency in daytime. The inversion intensity (ΔT) and inversion depth (ΔZ) of SBI and EI have consistent diurnal and seasonal trends. The effects of SBI and EI on the vertical distribution of aerosols are then analyzed. The mean aerosol optical depth (AOD) below the SBI height shows a clear seasonal variation, which is consistent with the seasonal trends of ΔT and ΔZ. This phenomenon also occurs on the AOD below EI top height. The sensitivity analysis shows that the mean AOD below SBI height or EI top height increases with an increase of the ΔT and ΔZ of SBI (EI). It indicates that ΔT and ΔZ are the key factors affecting the vertical distribution of aerosols. In addition, the variation of AOD below and above EI top height is opposite to that of AOD below and above EI bottom height under different ΔT and ΔZ conditions. The correlation coefficients between ΔT (ΔZ) of EI with AOD in EI were 0.62 (0.65). These results indicate that the space between EI bottom height and EI top height can store aerosols. The larger the ΔZ of EI, the more aerosols are stored. These findings contribute to our understanding of the effect of temperature inversion on the vertical distribution of aerosols.

54 ENVIRONMENTAL SCIENCES↗

Proxy quality control of biomass particles using thermogravimetric analysis and Gaussian process regression models

Abstract The temperature experienced by reactants during preparation in a reactor is a key component in determining the yield and homogeneity of usable chemical products such as biomass particles. Thermocouples with sensors can be used to monitor spatial temperature gradients within reactors but these sensors are often too expensive and/or invasive. The present work proposes a strategy to identify optimal machine learning models to infer the maximum effective temperature experienced by particles during oxidative biomass torrefaction using key thermochemical combustion parameters. The maximum rate of weight loss, the corresponding temperature, and fixed carbon content on a dry‐ash‐free basis are used as literature‐based predictor variables obtained from thermogravimetric analysis. The evaluation of 24 machine‐learning models using the standard tenfold cross‐validation method suggests that the exponential Gaussian process regression (GPR) model is the most effective, followed by other GPR models. These high‐performing GPR models were also utilized to predict the effective preparation temperature distribution of reactor‐produced biomass particles under eight conditions of varying residence time and air‐to‐biomass ratio. The effective preparation temperature and residence time of individual biomass particles were then encoded into the torrefaction severity factor and used to estimate the energy yield of the reactor output as a novel quality control method. © 2023 The Authors. Biofuels, Bioproducts and Biorefining published by Society of Industrial Chemistry and John Wiley & Sons Ltd.

09 BIOMASS FUELS↗

Magnetic field impact on the laser heating in MagLIF

Prior to implosion in Magnetized Liner Inertial Fusion (MagLIF), the fuel is heated to temperatures on the order of several hundred eV with a multi-kJ, multi-ns laser pulse. In this paper, we present two laser heated plasma experiments, relevant to the MagLIF preheat stage, performed at Z with beryllium liners filled with deuterium and a trace amount of argon. In one experiment, there is no magnetic field and, in the other, the liner and fuel are magnetized with an 8.5 T axial magnetic field. The recorded time integrated, spatially resolved spectra of the Ar K-shell emission are sensitive to electron temperature T e . Individual analysis of the spatially resolved spectra produces electron temperature distributions T e (z) that are resolved along the axis of laser propagation. In the experiment with magnetic field, the plasma reaches higher temperatures and the heated region extends deeper within the liner than in the unmagnetized case. Radiation magnetohydrodynamics simulations of the experiments are presented and post-processed. A comparison of the results from experimental and simulated data reveals that the simulations underpredict T e in both cases but the differences are larger in the case with magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional reconstruction of inertial confinement fusion hot-spot plasma from x-ray and nuclear diagnostics on OMEGA

Multidimensional effects degrade the neutron yield and the compressed areal density of laser-direct-drive inertial confinement fusion implosions of layered deuterium–tritium cryogenic targets on the OMEGA Laser System with respect to 1D radiation-hydrodynamic simulation predictions. A comprehensive physics-informed 3D reconstruction effort is under way to infer hot-spot and shell conditions at stagnation from four x-ray and seven neutron detectors distributed around the OMEGA target chamber. Neutron diagnostics, providing measurements of the neutron yield, hot-spot flow velocity, and apparent ion-temperature distribution, are used to infer the mode-1 perturbation at stagnation. The x-ray imagers record the shape of the hot-spot plasma to diagnose mode-1 and mode-2 perturbations. A deep-learning convolutional neural network trained on an extensive set of 3D radiation-hydrodynamic simulations is used to interpret the x-ray and nuclear measurements to infer the 3D profiles of the hot-spot plasma conditions and the amount of laser energy coupled to the hot-spot plasma. A 3D simulation database shows that larger mode-1 asymmetries are correlated with higher hot-spot flow velocities and reduced laser-energy coupling and neutron yield. Three-dimensional hot-spot reconstructions from x-ray measurements indicate that higher amounts of residual kinetic energy are correlated with higher measured hot-spot flow velocities, consistent with 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous inference of plate boundary stresses and mantle rheology using adjoints: large-scale 2-D models

SUMMARY Plate motions are a primary surface constraint on plate and mantle dynamics and rheology, plate boundary stresses and the occurrence of great earthquakes. Within an optimization method, we use plate motion data to better constrain uncertain mantle parameters. For the optimization problem characterizing the maximum a posteriori rheological parameters we derive gradients using adjoints and expressions to approximate the posterior distributions for stresses within plate boundaries. We apply these methods to a 2-D cross section from the western to eastern Pacific, with temperature distributions and fault zone geometries developed primarily from seismic and plate motion data. We find that the best-fitting stress exponent, n, is about 2.8 and the yield stress about 100 MPa or less. The normal stress on the interplate fault zones is about 100 MPa and the shear stresses about 10 MPa or less.

Rudi, Johann (ORCID:0000000265639265)↗

Near-Surface Imaging of the Multicomponent Gas Phase above a Silver Catalyst during Partial Oxidation of Methanol

Fundamental chemistry in heterogeneous catalysis is increasingly explored using operando techniques in order to address the pressure gap between ultrahigh vacuum studies and practical operating pressures. Because most operando experiments focus on the surface and surface-bound species, there is a knowledge gap of the near-surface gas phase and the fundamental information the properties of this region convey about catalytic mechanisms. In this work, we demonstrate in situ visualization and measurement of gas-phase species and temperature distributions in operando catalysis experiments using complementary near-surface optical and mass spectrometry techniques. The partial oxidation of methanol over a silver catalyst demonstrates the value of these diagnostic techniques at 600 Torr (800 mbar) pressure and temperatures from 150 to 410 °C. Planar laser-induced fluorescence provides two-dimensional images of the formaldehyde product distribution that show the development of the boundary layer above the catalyst under different flow conditions. Raman scattering imaging provides measurements of a wide range of major species, such as methanol, oxygen, nitrogen, formaldehyde, and water vapor. Near-surface molecular beam mass spectrometry enables simultaneous detection of all species using a gas sampling probe. Detection of gas-phase free radicals, such as CH 3 and CH 3 O, and of minor products, such as acetaldehyde, dimethyl ether, and methyl formate, provides insights into catalytic mechanisms of the partial oxidation of methanol. The combination of these techniques provides a detailed picture of the coupling between the gas phase and surface in heterogeneous catalysis and enables parametric studies under different operating conditions, which will enhance our ability to constrain microkinetic models of heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Modeling and Simulation of a Generic Stable Salt Reactor

A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.

stable salt reactor; transient simulations; system↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explicit Modeling of Pebble Temperature in the Porous-medium Framework for Pebble-bed Reactors Applications

In this study, an explicit model for pebble temperature calculations in the framework of a porous-medium approach has been developed and implemented in the SAM code. The solid-phase energy conservation equation, including the explicit modeling of pebble temperature, is a multi-scale model, which can predict the macroscopic (pebble-bed) and microscopic (pebble) temperature distributions under both steady-state and transient conditions. Extensive and successful code verifications and demonstrations have been performed for this newly developed model. By explicitly modeling pebble temperatures, this new model addresses a major deficiency of the previously implemented model, which assumed a local solid-phase thermal equilibrium that is not appropriate for pebble-bed reactor design and safety analysis applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗