Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Time-Domain Vortex Induced Vibration Modeling of Reference Dynamic Power Cable for the Gulf of Maine

Vortex-induced vibration (VIV) is a phenomenon known to decrease the fatigue life of dynamic power cables used in floating offshore wind systems through increased bending loading cycles. A variety of modeling solutions have been proposed to study this, but none enable fully-coupled simulations leveraging open-source tools. To address this, a time-domain VIV model has been successfully implemented into the open-source mooring dynamics model MoorDyn. The semi-empirical VIV model describes a lift force acting on segments of a flexible cylinder, making it well suited for implementation into MoorDyn. The new capability successfully predicted the frequencies and magnitudes of strain in both steady and oscillating flows when compared to the original validation results and matched peak spectral response when compared to experimental results, verifying successful implementation. MoorDyn with VIV was then leveraged to simulate a 15 MW floating turbine with a dynamic power cable in the Gulf of Maine using OpenFAST for six return periods of combined wind, wave, and current conditions. Increased curvature and tension fluctuations in higher flow speeds were observed when simulating VIV. Maximum tensions and curvatures also increased, with the 500 year conditions violating the curvature factor of safety of 2.0. These results highlight the importance of considering VIV when designing dynamic power cables for the Gulf of Maine, and indicate that cost effective mitigation strategies should be explored for the area. They also demonstrate the utility of this new modeling capability, which provides the first open-source tool for fully coupled time-domain floating offshore wind simulations with dynamic power cable VIV.

17 WIND ENERGY↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How earthquakes organize stress

Stress is not uniform in the Earth. Therefore, we must use natural experiments to measure the distribution of stresses and related quantities, rather than single values. For instance, dynamic triggering shows that faults are uniformly distributed over their loading cycles in Southern California. The probability that a fault ruptures across a barrier measures the in situ energy distribution. Fault roughness reflects the distribution of strength. These natural experiments produce observable distributions that are surprisingly consistent and suggest some degree of self-organization in the Earth’s crust. Once established, the functional form of the distributions can be used to track changes in response to earthquakes as well as to distinguish fundamentally different fault systems. Transient fault locking before stress release in laboratory experiments can be interpreted as a consequence of self-organization of fault stress. The robust self-organization of multiple variables in earthquake systems suggests that the most consequential mechanical outcome of earthquakes may be the redistribution of stress and the strain energy associated with it. The low friction on a fault during seismic slip as inferred by temperature measurements of the Tohoku earthquake is consistent with dissipation playing a secondary role to this redistribution process. Through stress redistribution and interaction, subduction zone faults tend to synchronize, perhaps due to their geometric simplicity, while the continental system of Southern California cannot synchronize, perhaps due to the complexity of the fault network. Earthquakes organize stress in the crust and produce a suite of well-defined, consistent distributions.

earthquakes↗

OODG (OnlineOptDynaGrid) [SWR-24-07]

This is a repository for the code developed by NREL under the DynaGrid project. It is a Julia package for running a model-free real-time OPF algorithm to operate dynamic networked microgrids given network configuration results from the Maximal Load Delivery (MLD) problem in the PowerModelsONM.jl package. See Example.jl for a working example on how to use the package. Note: Julia package PowerModelsONM.jl is needed.

Poolla, Bala Kameshwar [National Renewable Energy ↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

A Dynamic Pricing Method to Manage the Impact of EV Charging on the Grid Using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

EV charging, dynamic pricing, grid-informed chargi↗

A dynamic pricing method to manage the impact of EV charging on the grid using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Investigation into the instantaneous centre of rotation for enhanced design of floating offshore wind turbines

The dynamic behaviour of floating offshore wind turbines (FOWTs) involves complex interactions of multivariate loads from wind, waves, and currents, which result in complex motion characteristics. Although methods for analysing global motion responses are well-established, the time- and location-dependent kinematics remain underexplored. This paper investigates the instantaneous centre of rotation (ICR), a point of zero velocity at a time instance of general plane motion. Understanding and strategically positioning the ICR can reduce the dynamic motion in critical structural locations, enhancing the performance and structural robustness of FOWTs. The paper presents a method for computing the ICR using time-domain simulation results and proposes a statistical analysis approach suitable for design studies. Building on prior research, it examines the sensitivity of the ICR to external loading and design features, providing insights into how these factors influence motion response and how the motion response influences the statistics of the ICR, structural loads, and other performance metrics of interest. The study explores two FOWT configurations, a spar and a semisubmersible, identifying design variables that most effectively control the ICR statistics and identifying the ICR statistics most correlated with the responses of interest. Finally, through two case studies, we demonstrate how to apply these new insights in a practical design scenario. By adjusting the design variables most correlated with the ICR (fairlead vertical position and centre of mass for the spar and mooring line length and offset column diameter for the semisubmersible), we successfully modified the designs of the floating support structures to reduce the loads in the mooring lines, tower base, and blade roots, improving the ultimate strength and fatigue characteristics compared to the original designs.

17 WIND ENERGY↗

Step-loaded creep testing of Zircaloy-4 cladding at higher temperatures in the α-phase

A refined understanding of zirconium-based cladding thermomechanical performance during rapid transients is essential for enhancing the safety and operation of light-water reactors. Traditional models for zirconium alloys under accident conditions generally assume that creep dominates fuel cladding performance. Here, these historic models have largely remained unchanged and serve as the basis for safety criteria development. As the U.S. nuclear industry pursues higher burnup levels, the increased release of fission gases during transients raises the risk of cladding failure in the low-temperature hcp α-phase, making the fidelity of these models of greater importance. Creep testing was conducted from 550–700°C with 25–120 MPa applied hoop stresses to investigate Zircaloy-4 deformation at accident-relevant temperatures in the α-phase. Step-loading was employed to capture creep behavior across a wide stress range from a single sample. The stress-strain rate data at higher temperatures (650 and 700°C) were well-described by isotropic versions of the Erbacher and Kaddour models, while the lower temperature data (550 and 600°C) were underpredicted by both anisotropic and isotropic model variants. Greater strain rates during the initial loading step at 650 and 700°C were attributed to recrystallization and grain growth of sub-micron crystallites. Yet, texture analysis revealed the basal split texture remained after testing. These observations produced results suggesting Zircaloy-4 claddings experience higher creep rates across the α-phase than previously thought, possibly related to dynamic anisotropy due to temperature dependent activation of deformation mechanisms, effects of biaxial loading, and variation in material condition between the current testing used in previous model development.

36 MATERIALS SCIENCE↗

Reduced-Order CFD Modeling to Support Waste Loading Optimization in Hanford WTP Vitrification

The U.S. DOE Hanford Site stores over 56 million gallons of radioactive liquid tank waste that must be treated and immobilized for long-term disposal The Waste Treatment and Immobilization Plant (WTP) will vitrify this waste by feeding it into Joule-heated melters, where it is incorporated into a stable borosilicate glass Computational fluid dynamics (CFD) simulations of glass melters can provide insight into the maximum achievable waste loading under varying melter operating conditions Fully resolved VOF multiphase simulations were used as the reference model to capture bubble-driven convection in the melter, including bubble formation, rise behavior, and induced glass melt circulation Effective bubble column diameter and rise velocity were extracted from the resolved simulations, compared with empirical correlations, and refit across relevant viscosity and gas flow rate conditions Explicit gas–liquid interface tracking was replaced with a single-phase momentum source term model, enabling faster steady-state CFD simulations while preserving the dominant hydrodynamic effects of bubbling New empirical correlations were developed for effective bubble column diameter and bubble rise velocity by fitting resolved simulation data across expected melter viscosity and gas flow rate ranges, providing improved inputs for the momentum source term model compared with existing literature correlations The momentum source term model reduced fluid-domain mesh size by 89% and achieved an 8.4× computational speedup relative to resolved bubbling simulations The validated momentum source term approach enables prediction of process-relevant heat transfer behavior in the integrated melter model, including heat transfer from the molten glass to the cold cap, plenum, refractory walls, and surrounding structural regions under varying melter operating conditions

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Optimization of Fairing Geometry for ORPC Modular RivGen Power System: Cooperative Research and Development (Final Report)

The work will optimize the hydrodynamic performance and flow augmentation of Ocean Renewable Power Company's (ORPC) modular fairing for their cross-flow marine hydrokinetic (MHK) turbine, using a computational fluid dynamics study. The influence of the fairing cross-sectional shape and rotor-fairing spacing will be assessed, to maximize power production and minimize structural loads.

16 TIDAL AND WAVE POWER↗

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science↗

The nonlinear behavior of generic tail fins for small wind turbines

This paper describes analysis and measurements of the yaw response of tail fins for small wind turbines. It is based on an extension of unsteady slender body theory (USBT) to cover non-slender fins and high angles of incidence, both of which make the theory nonlinear. We provide three main additions to the substantial literature on linearized USBT for tail fins. First, USBT is extended to high angles by modeling the nonlinear vortex dynamics. Second, the restriction to slender bodies is removed by modeling the chordwise load variation. Third, we consider the effect of time-varying wind speed. Further, the extended theory is compared to wind tunnel measurements of the yaw behavior of delta, elliptical, and rectangular tail fins without a rotor and nacelle. The fins were released from initial yaw angles of -40° and -80°; the latter is of sufficient magnitude to show the importance of the nonlinear yaw dynamics. Generally good agreement was found between the theory and measurements, and the theory was shown to be more accurate than a “polar” or quasi-steady model which uses only the lift and drag of a delta planform. Of the three planforms, the rectangular one showed the lowest accuracy in terms of frequency but the damping was accurately predicted. Overall, the results demonstrate the importance of nonlinearity in the response of a yawing tail fin, particularly for the higher aspect ratio fins at large yaw angles.

17 WIND ENERGY↗

Photocatalytic Semiconductor–Metal Hybrid Nanoparticles: Single-Atom Catalyst Regime Surpasses Metal Tips

Semiconductor–metal hybrid nanoparticles (HNPs) are promising materials for photocatalytic applications, such as water splitting for green hydrogen generation. While most studies have focused on Cd containing HNPs, the realization of actual applications will require environmentally compatible systems. Using heavy-metal free ZnSe-Au HNPs as a model, we investigate the dependence of their functionality and efficiency on the cocatalyst metal domain characteristics ranging from the single-atom catalyst (SAC) regime to metal-tipped systems. The SAC regime was achieved via the deposition of individual atomic cocatalysts on the semiconductor nanocrystals in solution. Utilizing a combination of electron microscopy, X-ray absorption spectroscopy, and X-ray photoelectron spectroscopy, we established the presence of single Au atoms on the ZnSe nanorod surface. Upon increased Au concentration, this transitions to metal tip growth. Photocatalytic hydrogen generation measurements reveal a strong dependence on the cocatalyst loading with a sharp response maximum in the SAC regime. Ultrafast dynamics studies show similar electron decay kinetics for the pristine ZnSe nanorods and the ZnSe-Au HNPs in either SAC or tipped systems. This indicates that electron transfer is not the rate-limiting step for the photocatalytic process. Combined with the structural-chemical characterization, we conclude that the enhanced photocatalytic activity is due to the higher reactivity of the single-atom sites. This holistic view establishes the significance of SAC-HNPs, setting the stage for designing efficient and sustainable heavy-metal-free photocatalyst nanoparticles for numerous applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and Flow-Viscosity of Filled-Polymer-Based 3D Printing Ink: Exploration through Coarse-Grained Molecular Dynamics

The addition of nanofiller particles to a polymer matrix has long been known to enhance or modify the composite’s mechanical and rheological properties. However, quantitatively capturing such changes with molecular level simulations remains computationally challenging. Toward that goal, we performed coarse-grained molecular dynamics of a nanocomposite system at a fixed (25 vol %) filler loading under nonspecific, weak polymer–filler interactions representative of a broad class of technologically important materials. We report several interesting results, including: (1) the equilibrium chain-configuration remains Gaussian-like as in an unfilled melt; (2) smaller filler particles display a stronger tendency to cluster; (3) larger fillers act as plasticizers by reducing the entanglement density and accelerating the chain mobility; and (4) fillers enhance the tensile response modulus, with the effect being stronger for larger particles. We also simulate cluster breakup, yielding, and elongational flow under an applied time-linear tensile strain and study the flow viscosity as a function of filler-size and chain-length.

Materials science↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, previous synchronization analysis for heterogeneous systems requires the machines to satisfy certain proportionality property. In our approach, the effective transfer functions for each cluster can be tuned by the IBRs to satisfy such property, enabling us to apply the shaping control to systems with a wider range of heterogeneous machines.

frequency-shaping control↗