Search NASA⌕ Search

SEARCH · Search NASA

Results for “EBIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Incidence of Leukoencephalopathy After Whole-Brain Radiation Therapy for Brain Metastases

Purpose: To evaluate the incidence of leukoencephalopathy after whole-brain radiation therapy (WBRT) in patients with brain metastases. Methods and Materials: We retrospectively reviewed 111 patients who underwent WBRT for brain metastases from April 2001 through March 2008 and had evaluable computed tomography (CT) and/or magnetic resonance imaging (MRI) at least 1 month after completion of WBRT. We evaluated the leukoencephalopathy according to the Common Terminology Criteria for Adverse Events, version 3.0. The patients who had brain tumor recurrence after WBRT were censored at the last follow-up CT or MRI without recurrence. To evaluate the risk factors for leukoencephalopathy, bivariate analysis was performed using a logistic regression analysis adjusted for follow-up time. Factors included in the analysis were age, gender, dose fractionation, 5-fluorouracil, methotrexate, cisplatin, and other chemotherapeutic agents. Results: The median age of the 111 patients was 60.0 years (range, 23-89 years). The median follow-up was 3.8 months (range, 1.0-38.1 months). Leukoencephalopathy developed in 23 of the 111 patients. Grades 1, 2, and 3 were observed in 8, 7, and 8 patients, respectively. The incidence was 34.4% (11 of 32), 42.9% (6 of 14), 66.7% (2 of 3), and 100% (2 of 2) of the patients who were followed up for ≥6, ≥12, ≥24, and ≥36 months, respectively. In the bivariate analysis, older age (≥65 years) was significantly correlated with higher risk of leukoencephalopathy (odds ratio 3.31; 95% confidence interval 1.15-9.50; P=.03). Conclusions: The incidence of leukoencephalopathy after WBRT was 34.4% with ≥6 months follow-up, and increased with longer follow-up. Older age was a significant risk factor. The schedule of WBRT for patients with brain metastases should be carefully determined, especially for favorable patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-temperature deformation behavior and microstructural characterization of high-Mn bearing titanium-based alloy

Highlights: • The hot deformation behavior of a biomedical low-cost Ti-10Mn alloys was studied. • The flow curves of the alloy display periodic serrations attributed to dynamic strain aging. • Mn alloying increases the activation energy to 243 kJ/mol compared to pure Ti. • The dynamic recovery is more effective than dynamic recrystallization at hot deformation. - Abstract: Ti-Mn alloys exhibit an excellent potential for biomedical applications as well as structural engineering applications, especially in the aerospace industry. In order to control and enhance grain structure during the manufacturing of Ti-Mn alloys and thereby help to enhance mechanical properties such as strength and toughness, we studied the hot-deformation behavior of βTi-10Mn alloys. Isothermal compression tests were conducted in the strain rate range of 0.01–10 s{sup −1} and temperatures in the range of 850–1000 °C using a Gleeble thermomechanical simulator. High-temperature flow stress curves exhibited discontinuous yielding and pronounced periodic serrations without any strain hardening during compression straining of these alloys. Such peculiar behavior of this alloy is due to active dynamic strain aging in its β-bcc structure. Metallographic observations by electron-backscattered diffraction (EBSD) analysis revealed that dynamic recovery (DRV) is more active than continuous dynamic recrystallization (CDRX) when the alloy is deformed at high strain rates, i.e. higher than 1 s{sup −1}. Furthermore, the constitutive behavior of the alloy was modeled and the apparent hot-deformation activation energy of the alloy was estimated to be 243 kJ/mol, which is ~60% higher than the self-diffusion energy in pure titanium.

36 MATERIALS SCIENCE↗

10 New Insights in Climate Science 2020 - a Horizon Scan

We summarize some of the past year’s most important findings within climate change-related research. New research has improved our understanding of Earth’s sensitivity to carbon dioxide, finds that permafrost thaw could release more carbon emissions than expected and that the uptake of carbon in tropical ecosystems is weakening. Adverse impacts on human society include increasing water shortages and impacts on mental health. Options for solutions emerge from rethinking economic models, rights-based litigation, strengthened governance systems and a new social contract. The disruption caused by COVID-19 could be seized as an opportunity for positive change, directing economic stimulus towards sustainable investments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cellular, molecular, and therapeutic characterization of pilocarpine-induced temporal lobe epilepsy

Animal models have expanded our understanding of temporal lobe epilepsy (TLE). However, translating these to cell-specific druggable hypotheses is not explored. Herein, we conducted an integrative insilico-analysis of an available transcriptomics dataset obtained from animals with pilocarpine-induced-TLE. A set of 119 genes with subtle-to-moderate impact predicted most forms of epilepsy with ~ 97% accuracy and characteristically mapped to upregulated homeostatic and downregulated synaptic pathways. The deconvolution of cellular proportions revealed opposing changes in diverse cell types. The proportion of nonneuronal cells increased whereas that of interneurons, except for those expressing vasoactive intestinal peptide (Vip), decreased, and pyramidal neurons of the cornu-ammonis (CA) subfields showed the highest variation in proportion. A probabilistic Bayesian-network demonstrated an aberrant and oscillating physiological interaction between nonneuronal cells involved in the blood–brain-barrier and Vip interneurons in driving seizures, and their role was evaluated insilico using transcriptomic changes induced by valproic-acid, which showed opposing effects in the two cell-types. Additionally, we revealed novel epileptic and antiepileptic mechanisms and predicted drugs using causal inference, outperforming the present drug repurposing approaches. These well-powered findings not only expand the understanding of TLE and seizure oscillation, but also provide predictive biomarkers of epilepsy, cellular and causal micro-circuitry changes associated with it, and a drug-discovery method focusing on these events.

60 APPLIED LIFE SCIENCES↗

Expansion in higher harmonics of boson stars using a generalized Ruffini-Bonazzola approach. Part 1. Bound states

The method pioneered by Ruffini and Bonazzola (RB) to describe boson stars involves an expansion of the boson field which is linear in creation and annihilation operators. This expansion constitutes an exact solution to a non-interacting field theory, and has been used as a reasonable ansatz for an interacting one. In this work, we show how one can go beyond the RB ansatz towards an exact solution of the interacting operator Klein-Gordon equation, which can be solved iteratively to ever higher precision. Our Generalized Ruffini-Bonazzola approach takes into account contributions from nontrivial harmonic dependence of the wavefunction, using a sum of terms with energy $k\,E_0$, where $k\geq1$ and $E_0$ is the chemical potential of a single bound axion. The method critically depends on an expansion in a parameter $\Delta \equiv \sqrt{1-E_0{}^2/m^2}<1$, where $m$ is the mass of the boson. In the case of the axion potential, we calculate corrections which are relevant for axion stars in the transition or dense branches. We find with high precision the local minimum of the mass, $M_{min}\approx 463\,f^2/m$, at $\Delta\approx0.27$, where $f$ is the axion decay constant. This point marks the crossover from transition to dense branches of solutions, and a corresponding crossover from structural instability to stability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

OSIRIS-REx constraints on local dark matter and cosmic neutrino profiles

We derive purely gravitational constraints on dark matter and cosmic neutrino profiles in the solar system using asteroid (101955) Bennu. We focus on Bennu because of its extensive tracking data and high-fidelity trajectory modeling resulting from the OSIRIS-REx mission. We find that the local density of dark matter is bound by $ρ_{DM}$ ≲ 3.3 × 10 -15 kg/m 3 ≃ 6 × 10 6 $\bar{ρ_{DM}}$, in the vicinity of ~ 1.1 au (where $\bar{ρ_{DM}}$ ≃ 0.3 GeV/cm 3 ). We show that high-precision tracking data of solar system objects can constrain cosmic neutrino overdensities relative to the Standard Model prediction n̅ν, at the level of η ≡ nν/n̅ν ≲ 1.7 × 10 11 (0.1 eV/m ν ) (Saturn), comparable to the existing bounds from KATRIN and other previous laboratory experiments (with m ν the neutrino mass). These local bounds have interesting implications for existing and future direct-detection experiments. Our constraints apply to all dark matter candidates but are particularly meaningful for scenarios including solar halos, stellar basins, and axion miniclusters, which predict overdensities in the solar system. Furthermore, introducing a DM-SM long-range fifth force with a strength tilde alphaDtimes stronger than gravity, Bennu can set a constraint on ρDM ≲ $\bar{ρ_{DM}}$(6 × 10 6 /$_{\tilde{αD}}$). These constraints can be improved in the future as the accuracy of tracking data improves, observational arcs increase, and more missions visit asteroids.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser ion source for high brightness heavy ion beam

A laser ion source is known as a high current high charge state heavy ion source. But, we place great emphasis on the capability to realize a high brightness ion source. A laser ion source has a pinpoint small volume where materials are ionized and can achieve quite uniform low temperature ion beam. Those features may enable us to realize very small emittance beams. Furthermore, a low charge state high brightness laser ion source was successfully commissioned in Brookhaven National Laboratory in 2014. Now most of all the solid based heavy ions are being provided from the laser ion source for regular operation.

43 PARTICLE ACCELERATORS↗

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium β-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous 83m Kr was injected into the KATRIN source section, and a condensed 83m Kr source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. In conclusion, we have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a liquid Ga target for Laser Ion Source

We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.

43 PARTICLE ACCELERATORS↗

Reframing climate change assessments around risk: recommendations for the US National Climate Assessment

Climate change is a risk management challenge for society, with uncertain but potentially severe outcomes affecting natural and human systems, across generations. Managing climate-related risks will be more difficult without a base of knowledge and practice aimed at identifying and evaluating specific risks, and their likelihood and consequences, as well as potential actions to promote resilience in the face of these risks. Here, we suggest three improvements to the process of conducting climate change assessments to better characterize risk and inform risk management actions.

54 ENVIRONMENTAL SCIENCES↗