Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC WIRING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Low-speed flowfield characterization by infrared measurements of surface temperatures

An experimental program was aimed at identifying areas in low speed aerodynamic research where infrared imaging systems can make significant contributions. Implementing a new technique, a long electrically heated wire was placed across a laminar jet. By measuring the temperature distribution along the wire with the IR imaging camera, the flow behavior was identified. Furthermore, using Nusselt number correlations, the velocity distribution could be deduced. The same approach was used to survey wakes behind cylinders in a wind-tunnel. This method is suited to investigate flows with position dependent velocities, e.g., boundary layers, confined flows, jets, wakes, and shear layers. It was found that the IR imaging camera cannot accurately track high gradient temperature fields. A correlation procedure was devised to account for this limitation. Other wind-tunnel experiments included tracking the development of the laminar boundary layer over a warmed flat plate by measuring the chordwise temperature distribution. This technique was applied also to the flow downstream from a rearward facing step. Finally, the IR imaging system was used to study boundary layer behavior over an airfoil at angles of attack from zero up to separation. The results were confirmed with tufts observable both visually and with the IR imaging camera.

Gartenberg, E.↗

Infrastructure for deployment of power systems

A preliminary effort in characterizing the types of stationary lunar power systems which may be considered for emplacement on the lunar surface from the proposed initial 100-kW unit in 2003 to later units ranging in power from 25 to 825 kW is presented. Associated with these power systems are their related infrastructure hardware including: (1) electrical cable, wiring, switchgear, and converters; (2) deployable radiator panels; (3) deployable photovoltaic (PV) panels; (4) heat transfer fluid piping and connection joints; (5) power system instrumentation and control equipment; and (6) interface hardware between lunar surface construction/maintenance equipment and power system. This report: (1) presents estimates of the mass and volumes associated with these power systems and their related infrastructure hardware; (2) provides task breakdown description for emplacing this equipment; (3) gives estimated heat, forces, torques, and alignment tolerances for equipment assembly; and (4) provides other important equipment/machinery requirements where applicable. Packaging options for this equipment will be discussed along with necessary site preparation requirements. Design and analysis issues associated with the final emplacement of this power system hardware are also described.

Sprouse, Kenneth M.↗

Magnetic detector for projectiles in tubes

A new wall-mounted, magnetic detector is presented for measuring projectile passage times in tubes. The detector has the advantages of simplicity over laser and microwave techniques and has other advantages over the electrical contact wire technique. Representative data are presented. The detector is shown to be very insensitive to strong pressure waves and combustion, but able to detect the passage of the projectile (carrying one or two magnets) clearly. Two modes of operation of the detector are described and the use of these detectors to measure projectile velocities, accelerations, and spin rates is discussed.

Bogdanoff, D. W.↗

Influence of temperature gradients on the measurement accuracy of IR imaging systems

Implementing a new experimental aerodynamic technique, a long electrically heated wire was placed across flows with general velocity distributions (wakes, jets). By measuring the temperature distribution along the wire with an IR camera, the flow behavior was identified. Furthermore, it is suggested that by using Nusselt number correlations, the velocity distributions can be deduced. Comparing the results with predictions based on heat transfer correlations, it was found that the IR camera cannot accurately track high gradient temperature fields. A correction procedure is outlined to account for the errors found in the measured results.

Gartenberg, Ehud↗

A turbulence indicator utilizing the diffusion of heat

This report describes a method of determining the turbulence in wind tunnels. The effect of turbulence upon the diffusion of heat from a small electrically heated wire in an air stream was investigated. The turbulence of the stream was introduced by a series of geometrically similar screens placed one at a time across the upstream section of the tunnel. With the wire set at various distances from the screens, curves of temperature distribution were obtained by traversing the heated wake at a distance of 2 inches behind the wire with a small thermocouple.

Schubauer, G B↗

Electrical and mechanical testing of wire insulation for space applications

Results of tests comparing M81381/7 versus Gore HSCR wire insulation on corona inception and extinction, time and current to smoke, wire fusing time, abrasion, flex life, and dynamic cut-through are presented in view-graph format. Results show that Gore is not comparable to M81381 in performance at elevated temperatures, that mechanical properties of M81381 are superior, and that corona and wire fusing times are equivalent.

Burkhardt, Linda A.↗

Swept Inducer Blades With Tandem Radial Slots

Slanted radial slots at tandem positions along approximate streamlines incorporated into swept inducer blades in turbopump, according to proposal. With suitable design, slots suppress low-frequency oscillations induced by cavitation, without causing excessive loss of inducer head. Slots cut into solid blades by wire electrical-discharge machining.

Meng, Sen Y.↗

Effect Of Low External Flow On Flame Spreading Over ETFE Insulated Wire Under Microgravity

Fire safety is one of the most important issues for manned space missions. A likely cause of fires in spacecraft is wire insulation combustion in electrical system. Regarding the wire insulation combustion it important to know the effect of low external flow on the combustion because of the presence of ventilation flow in spacecraft. Although, there are many researches on flame spreading over solid material at low external flows under microgravity, research dealing with wire insulation is very limited. An example of wire insulation combustion in microgravity is the Space Shuttle experiments carried out by Greenberg et al. However, the number of experiments was very limited. Therefore, the effect of low flow velocity is still not clear. The authors have reported results on flame spreading over ETFE (ethylene - tetrafluoroetylene) insulated wire in a quiescent atmosphere in microgravity by 10 seconds drop tower. The authors also performed experiments of polyethylene insulated nichrom wire combustion in low flow velocity under microgravity. The results suggested that flame spread rate had maximum value in low flow velocity condition. Another interesting issue is the effect of dilution gas, especially CO2, which is used for fire extinguisher in ISS. There are some researches working on dilution gas effect on flame spreading over solid material in quiescent atmosphere in microgravity. However the research with low external flow is limited and, of course, the research discussing a relation of the appearance of maximum wire flammability in low flow velocity region with different dilution gas cannot be found yet. The present paper, therefore, investigates the effect of opposed flow with different dilution gas on flame spreading over ETFE insulated wire and change in the presence of the maximum flammability depending on the dilution gas type is discussed within the limit of microgravity time given by ground-based facility.

Nishizawa, Katsuhiro↗

Buoyancy Effects in Strongly-pulsed, Turbulent Diffusion Flames

The objective of this experiment is to better understand the combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. The fuel jet is fully-modulated (i.e., completely shut off between pulses) by an externally controlled valve system leading to enhanced fuel/air mixing compared to acoustically excited or partially-modulated jets. Experiments are conducted both in laboratories at UW and WPI and in the GRC 2.2s Drop Tower. A single fuel nozzle with diameter d = 2 mm is centered in a combustor 20 x 20 cm in cross section and 67 cm in height. The gaseous fuel flow (ethylene or a 50/50 ethylene/nitrogen mixture by volume) is fully-modulated by a fast-response solenoid valve with injection times from tau = 4 to tau = 300 ms. The nominal Reynolds number based on the fuel velocity during injection, U(sub jet), is 5,000. A slow oxidizer co-flow properly ventilates the flame and an electrically heated wire loop serves as a continuous ignition source. Diagnostic techniques include video imaging, fine-wire thermocouples and thermopile radiometers, and gas sampling and standard emissions instruments (the last in the laboratory only).

Hermanson, J. C.↗

Buoyancy Effects in Strongly-Pulsed, Turbulent Diffusion Flames

The objective of this experiment is to better understand the combustion behavior of pulsed, turbulent diffusion flames by conducting experiments in microgravity. The fuel jet is fully-modulated (i.e., completely shut off between pulses) by an externally controlled valve system leading to enhanced fuel/air mixing compared to acoustically excited or partially-modulated jets. Experiments are conducted both in laboratories at UW and WPI and in the GRC 2.2s Drop Tower. A single fuel nozzle with diameter d = 2 mm is centered in a combustor 20 20 cm in cross section and 67 cm in height. The gaseous fuel flow (ethylene or a 50/50 ethylene/nitrogen mixture by volume) is fully-modulated by a fast-response solenoid valve with injection times from tau = 4 to tau = 300 ms. The nominal Reynolds number based on the fuel velocity during injection, U(sub jet), is 5,000. A slow oxidizer co-flow properly ventilates the flame and an electrically heated wire loop serves as a continuous ignition source. Diagnostic techniques include video imaging, fine-wire thermocouples and thermopile radiometers, and gas sampling and standard emissions instruments (the last in the laboratory only).

Hermanson, J. C.↗

Magnetic Field Response Measurement Acquisition System

A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

Woodard, Stanley E.↗

Smoldering News From STS-77 Endeavour

The Microgravity Smoldering Combustion (MSC) experiment lifted off aboard the Space Shuttle Endeavour for its second flight in May 1996, as part of the STS-77 mission. This experiment is part of a series of studies focused on the smolder characteristics of porous combustible materials in a microgravity environment. Smoldering is a nonflaming form of combustion that takes place in the interior of combustible materials. Common examples of smoldering are nonflaming embers, charcoal briquettes, and cigarettes. The objective of this study is to provide a better understanding of the controlling mechanisms of smoldering in microgravity and normal Earth gravity (1g). As with other forms of combustion, gravity affects the availability of air and transport of heat, and therefore, the rate of combustion. The results of the microgravity experiments will be compared with identical ones carried out in 1g. In addition, they will be used to verify present theories of smolder combustion and will provide new insights into the process of smoldering combustion, enhancing our fundamental understanding of this frequently encountered combustion process and guiding improvements in fire safety practices. Two smoldering combustion tests with polyurethane foam were successfully accomplished during the STS-77 mission. The tests investigated smoldering combustion in a quiescent (no-flow) enriched oxygen environment, and in an air environment with a 2-mm/sec airflow through the fuel sample. The primary data from the tests are the ignition characteristics, spread rate, smolder reaction temperature, and products of combustion (solid and gas). On both the first mission on STS-69 and the second mission on STS-77, a smolder front propagated the length of the forced-flow samples, with the spread rate between the corresponding upward and downward 1g smolder rates. Neither of the quiescent cases propagated combustion (the first case was due in part to a problem with the experiment electronics). These results show a dramatic difference from the normal gravity results, where smolder propagation is very rapid and complete for both of these conditions. The experiment was conceived by Prof. A. Carlos Fernandez-Pello at the University of California-Berkeley. The MSC hardware was designed and built at the NASA Lewis Research Center by a team of civil servants and contractors from NYMA, Inc., and Aerospace Design & Fabrication, Inc. (ADF). The hardware consists of two sealed aluminum combustion chambers (each being a half a cylinder). The chambers hold the MSC test section, data acquisition electronics, power distribution electronics, and instrumentation. The hardware is fitted into a 5-ft(sup 3) Get-Away-Special (GAS) canister that is mounted in the shuttle cargo bay. The test section consists of a quartz cylinder that contains the polyurethane foam sample and an igniter. This igniter, which is an electrically heated wire sandwiched between two porous ceramic disks, is mounted in contact with the end of the foam sample. An array of 12 thermocouples placed axially and radially along the foam sample provide temperature histories, which are used to determine the rate of smolder propagation, and the characteristics of the reaction.

Koudelka, John M.↗

Magnetic Field Response Measurement Acquisition System

This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

Woodard, Stanley E.↗

Making High-Tensile-Strength Amalgam Components

Structural components made of amalgams can be made to have tensile strengths much greater than previously known to be possible. Amalgams, perhaps best known for their use in dental fillings, have several useful attributes, including room-temperature fabrication, corrosion resistance, dimensional stability, and high compressive strength. However, the range of applications of amalgams has been limited by their very small tensile strengths. Now, it has been discovered that the tensile strength of an amalgam depends critically on the sizes and shapes of the particles from which it is made and, consequently, the tensile strength can be greatly increased through suitable choice of the particles. Heretofore, the powder particles used to make amalgams have been, variously, in the form of micron-sized spheroids or flakes. The tensile reinforcement contributed by the spheroids and flakes is minimal because fracture paths simply go around these particles. However, if spheroids or flakes are replaced by strands having greater lengths, then tensile reinforcement can be increased significantly. The feasibility of this concept was shown in an experiment in which electrical copper wires, serving as demonstration substitutes for copper powder particles, were triturated with gallium by use of a mortar and pestle and the resulting amalgam was compressed into a mold. The tensile strength of the amalgam specimen was then measured and found to be greater than 10(exp 4) psi (greater than about 69 MPa). Much remains to be done to optimize the properties of amalgams for various applications through suitable choice of starting constituents and modification of the trituration and molding processes. The choice of wire size and composition are expected to be especially important. Perusal of phase diagrams of metal mixtures could give insight that would enable choices of solid and liquid metal constituents. Finally, whereas heretofore, only binary alloys have been considered for amalgams, ternary additions to liquid or solid components should be considered as means to impart desired properties to amalgams.

Grugel, Richard↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗

Gas Sensors with Contact Pads

Systems, methods, and other embodiments associated with gas detecting sensors. According to one embodiment, a gas sensor includes a metal layer, a barrier interlayer, a substrate layer, a first insulating layer, a conduction path, a contact pad, and a second insulating layer. The conduction path connects the metal layer to the contact pad. The second insulating layer prevents diffusion through the contact pad, the conduction path, or the metal layer. The sensor includes a wire bonded electrical connection to the contact pad such that voltage can be determined and/or applied.

Xu, Jennifer↗

Investigation of factors affecting the heater wire method of calibrating fine wire thermocouples

An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.

Keshock, E. G.↗