Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The photoelectron-spectrometer experiment on Atmosphere Explorer.

The Atmosphere Explorer (AE) photoelectron spectrometer experiment consists of electrostatic deflection-type electron spectrometers designed to measure the low-energy electron flux expected to be encountered along the AE orbit. The system has been designed to provide general information on the intensity, angular distribution, energy spectrum, and net flows along field lines as well as sufficient energy resolution to allow the fine details of the electron-energy spectrum to be studied. The instrumentation consists of two separate electron-spectrometer detector heads connected to a common electronics system for data processing and telemetry interfacing. The experiment will measure the electron-energy spectrum from 2 to 500 eV (and possibly to less than 0.1 eV).

Doering, J. P.↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Microcontrollers Generate Timing Signals For CCD Arrays

Microcontrollers generate timing signals for charge-coupled-device array detectors in electronic system developed to test such detectors. With microcontroller, one changes timing signals via software, without changes in wiring. Approach more flexible, timing signals changed easier and quicker.

Hostetter, Marilyn K.↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

Radiation Effects of Protons and Electrons in Silicon Diffused-Junction Detectors

Diffused n-on-p silicon particle detectors were irradiated with 1-Mev electrons, and with 31-Mev and 8.2-Mev protons. The detector capacitance was observed to increase with electron irradiation and to decrease with proton irradiation. A physical interpretation is given in terms of defect energy levels known to be introduced in silicon by irradiation. Defect ionization states are taken to be characteristic of the space-charge region, rather than of bulk silicon. The relation to other studies of damage in semiconductor particle detectors is pointed out, considering differences in the types of detector and irradiation used. The significance of these results is discussed for detector applications where the damage threshold is exceeded.

Scott, R. E.↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.

Stevenson, T. R.↗

The Diogene 4 pi detector at Saturne

Diogene, an electronic 4 pi detector, has been built and installed at the Saturne synchrotron in Saclay. The forward angular range (0 degree-6 degrees) is covered by 48 time-of-flight scintillator telescopes that provide charge identification. The trajectories of fragments emitted at larger angles are recorded in a cylindrical 0.4-m3 Pictorial Drift Chamber (PDC) surrounding the target. The PDC is inside a 1-T magnetic field; the axis of the PDC cylinder and the magnetic field are parallel to the beam. Good identification has been obtained for both positive and negative pi mesons and for hydrogen and helium isotopes. Multiplicities in relativistic nucleus-nucleus reactions up to 40 have been detected, limited mainly by the present electronics.

Non-NASA Center↗

Chromatic Modulator for a High-Resolution CCD or APS

A chromatic modulator has been proposed to enable the separate detection of the red, green, and blue (RGB) color components of the same scene by a single charge-coupled device (CCD), active-pixel sensor (APS), or similar electronic image detector. Traditionally, the RGB color-separation problem in an electronic camera has been solved by use of either (1) fixed color filters over three separate image detectors; (2) a filter wheel that repeatedly imposes a red, then a green, then a blue filter over a single image detector; or (3) different fixed color filters over adjacent pixels. The use of separate image detectors necessitates precise registration of the detectors and the use of complicated optics; filter wheels are expensive and add considerably to the bulk of the camera; and fixed pixelated color filters reduce spatial resolution and introduce color-aliasing effects. The proposed chromatic modulator would not exhibit any of these shortcomings. The proposed chromatic modulator would be an electromechanical device fabricated by micromachining. It would include a filter having a spatially periodic pattern of RGB strips at a pitch equal to that of the pixels of the image detector. The filter would be placed in front of the image detector, supported at its periphery by a spring suspension and electrostatic comb drive. The spring suspension would bias the filter toward a middle position in which each filter strip would be registered with a row of pixels of the image detector. Hard stops would limit the excursion of the spring suspension to precisely one pixel row above and one pixel row below the middle position. In operation, the electrostatic comb drive would be actuated to repeatedly snap the filter to the upper extreme, middle, and lower extreme positions. This action would repeatedly place a succession of the differently colored filter strips in front of each pixel of the image detector. To simplify the processing, it would be desirable to encode information on the color of the filter strip over each row (or at least over some representative rows) of pixels at a given instant of time in synchronism with the pixel output at that instant.

Hartley, Frank↗

Practical application of HgI2 detectors to a space-flight scanning electron microscope

Mercuric iodide X-ray detectors have been undergoing tests in a prototype scanning electron microscope system being developed for unmanned space flight. The detector program addresses the issues of geometric configuration in the SEM, compact packaging that includes separate thermoelectric coolers for the detector and FET, X-ray transparent hermetic encapsulation and electrical contacts, and a clean vacuum environment.

Bradley, J. G.↗

Effect of the Mott cross section on charge identification in the HEAO-3 Heavy Cosmic Ray Experiment

Corrections to the Z-squared dependence of ion chamber and Cherenkov response due to the Mott cross section are calculated for the HEAO-3 Heavy Cosmic Ray Experiment. The effect of the production and escape of high energy secondary electrons on detector response is accounted for by numerical calculations. These secondary electron effects are shown to influence the size of the non Z-squared effects and thus affect the charge assignments and detector resolution. The Bloch and relativistic Bloch corrections are not included in the results presented here but may be combined with the Mott corrections when the Bloch corrections are properly evaluated.

Derrickson, J. H.↗

Wave-particle interactions induced by SEPAC on Spacelab 1 Wave observations

Space experiments with particle accelerators (SEPAC) flew on Spacelab 1 in November and December 1983. SEPAC included an accelerator which emitted electrons into the ionospheric plasma with energies up to 5 keV and currents up to 300 mA. The SEPAC equipment also included an energetic plasma generator, a neutral gas generator, and an extensive array of diagnostics. The diagnostics included plasma wave detectors, and energetic electron analyzer, a photometer, a high sensitivity television camera, a Langmuir probe and a pressure gage. Twenty-eight experiments were performed during the mission to investigate beam-plasma interactions, electron beam dynamics, plasma beam propagation, and vehicle charging. The wave-particle interactions were monitored by the plasma wave instrumentation, by the energetic electron detector and by the optical detectors. All show evidence of wave-particle interactions, which are described in this paper.

Taylor, W. W. L.↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗