Energy efficiency improves energy access affordability
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.
In this work, 3D simulations of oil jets impinging on a flat, heated wall are presented. The numerical setup uses the Volume of Fluid (VoF) method to model the two-phase flow. A careful grid definition across the liquid film, along with the use of the Conjugate Heat Transfer (CHT) approach allowed local heat transfer to be solved with fine resolution at the wall. Variations of liquid flow rate, liquid temperature and surface temperature allow to cover a wide range of local Reynolds and Prandtl numbers (226 < Re < 2850, 77 < Pr < 161). Resulting surface-averaged heat transfer compares very well with experimental measurements conducted in a previous study. In-depth analysis of the flow has identified expected features from the literature. In particular, the impact of jet axial velocity profiles on the heat transfer distribution in the stagnation zone was clearly stated. The increase in heat transfer when warming the liquid film was also reproduced and explained by a decrease in oil viscosity and an increase in film velocity. All those effects were taken into account in correlations for stagnation and local values of Nusselt number. A grid sensitivity study was also conducted, showing that if the grid solving the thermal boundary layer in the stagnation zone can be coarsened without impacting local and surface-averaged predictions of heat transfer, a minimum resolution (2 to 3 cells) within the thermal boundary layer is however required for an accurate prediction of heat transfer.
This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.
Not Available
Not Available
Not Available
We simulate pathways for achieving up to 100% renewable energy (RE) electric power systems for the contiguous United States. Under base conditions, the least-cost buildout has RE penetration growing up to 57% in 2050. Relative to this base scenario, average CO2 abatement costs of achieving 80%, 90%, 95%, and 100% RE are $25, $33, $40, and $61/ton, respectively, with system costs growing from $30 to $36/MWh at 95% (achieved in 2040) and $39/MWh at 100%. Incremental abatement costs from 99% to 100% RE reach $930/ton, driven primarily by the need for firm RE capacity. In addition to the base conditions, we also examined 22 alternative conditions for a buildout of up to 100%. These sensitivities capture different technology trajectories, compliance requirements, requirement timing, electrification, and transmission availability. Nonlinear marginal costs for the last few percent approaching 100% RE were found for all sensitivities, which might motivate alternative nonelectric-sector abatement opportunities.
Water is a critical resource for all of manufacturing. As such, mitigating risks to the supply of water to manufacturing plants facilitates maintaining a vital manufacturing sector. Reductions in water use through water efficiency is one method for mitigating risk, however little is known about its potential in the United States (U.S.) manufacturing sector. Herein, we address this gap and calculate the water reduction potential in U.S. manufacturing from commercially available water efficiency opportunities specific to the manufacturing sector. A list of water efficiency measures specific to the manufacturing sector is compiled and applied to estimates of U.S. manufacturing water withdrawals. The energy and carbon dioxide equivalent (CO 2 e) emission impacts from implementation of these measures are also quantified to better inform the resource, environmental, and economic trade-offs from implementation of these measures. We find that the water savings potential from the evaluated measures is up to 60 percent of U.S. manufacturing water withdrawal for certain subsectors, with the energy and emissions impact dependent on the measure. Further, we calculate the levelized cost of conserved water for several water efficiency measures (-$\$4,000$ to $\$85$/thousand m 3 , where negative values indicate net cost savings and positive values indicate net cost expenditures) and compare them to the levelized cost of alternative water sources ($\$600$ to $\$3,400$/thousand m 3 ). The results show significant opportunities for water and energy use reductions at levelized costs at least one order of magnitude lower than alternative water supplies, with some being revenue-generating.
Energy assessments can provide an effective way of identifying and implementing energy efficiency measures to save energy costs and avoid emissions throughout manufacturing facilities. Consequently, it generates significant economic and environmental benefits to localities, states, and the nation. Quantifying these benefits requires a systematic techno-economic-environmental framework for capturing the interactions. This article employs methodologies to improve the energy efficiency of small and medium-size industries through their sustainable industrial motor systems. Motor systems offer large opportunities to enhance energy efficiency through adopting advanced technologies and better-informed operations. Case studies presented illuminate the potential savings and impacts from implementing sustainable motor systems and the importance of energy assessments. Here, the integrated macro-economic analysis quantifies the regional sustainability impacts of implementing the industrial energy efficiency offered by an energy auditing program in Ohio over a ten-year period. Results show that implementing all the center’s motor recommendations have directly saved $\$702$ M in energy costs, avoided 2.7 million metric tons of carbon dioxide emissions, and created 3,445 jobs, resulting in a total annual economic impact of $\$788$ M stemming from direct, indirect, and induced regional economic impacts. It provides policy implications for encouraging sustainable industrial motor systems.
Cu-based catalysts for the electrochemical reduction of CO 2 and CO exhibit a perplexingly unique reactivity toward multicarbon based products compared to other studied electrocatalysts. Here, in this study, we use insights gained from a recent phenomenological 3-site microkinetic model and grand-canonical density functional theory calculations to clarify the importance of an underemphasized aspect critical to Cu’s unique reactivity: a population of so-called “reservoir” sites. Using model Cu surface motifs, we discuss how these types can be represented by undercoordinated structural defects like step edges and grain boundaries which form a network of highly anisotropic migration channels. These pathways are found to be amenable for feeding *CO over time to reactive sites like Cu adatoms more active toward C–C coupling. These results highlight an often overlooked aspect of catalyst optimization: reservoir site engineering, which exploits surface mobility and presents an equally important avenue for electrocatalyst engineering oversimply maximizing active site densities.
Artificial intelligence has emerged as a technology to enhance productivity and improve life quality. However, its role in building energy efficiency and carbon emission reduction has not been systematically studied. This study evaluated artificial intelligence’s potential in the building sector, focusing on medium office buildings in the United States. A methodology was developed to assess and quantify potential emissions reductions. Key areas identified were equipment, occupancy influence, control and operation, and design and construction. Six scenarios were used to estimate energy and emissions savings across representative climate zones. Here we show that artificial intelligence could reduce cost premiums, enhancing high energy efficiency and net zero building penetration. Adopting artificial intelligence could reduce energy consumption and carbon emissions by approximately 8% to 19% in 2050. Combining with energy policy and low-carbon power generation could approximately reduce energy consumption by 40% and carbon emissions by 90% compared to business-as-usual scenarios in 2050.
This paper introduces a database of 34 field-measured building occupant behavior datasets collected from 15 countries and 39 institutions across 10 climatic zones covering various building types in both commercial and residential sectors. This is a comprehensive global database about building occupant behavior. The database includes occupancy patterns (i.e., presence and people count) and occupant behaviors (i.e., interactions with devices, equipment, and technical systems in buildings). Brick schema models were developed to represent sensor and room metadata information. The database is publicly available, and a website was created for the public to access, query, and download specific datasets or the whole database interactively. The database can help to advance the knowledge and understanding of realistic occupancy patterns and human-building interactions with building systems (e.g., light switching, set-point changes on thermostats, fans on/off, etc.) and envelopes (e.g., window opening/closing). With these more realistic inputs of occupants’ schedules and their interactions with buildings and systems, building designers, energy modelers, and consultants can improve the accuracy of building energy simulation and building load forecasting.
Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.
The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.
Not Available