Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Evaluation of a locally homogeneous model of spray evaporation

A model of spray evaporation which employs a second-order turbulence model in conjunction with the locally homogeneous flow approximation, which implies infinitely fast interphase transport rates is presented. Measurements to test the model were completed for single phase constant and variable density jets, as well as an evaporating spray in stagnant air. Profiles of mean velocity, composition, temperature and drop size distribution as well as velocity fluctuations and Reynolds stress, were measured within the spray. Predictions were in agreement with measurements in single phase flows and also with many characteristics of the spray, e.g. flow width, radial profiles of mean and turbulent quantities, and the axial rate of decay of mean velocity and mixture fraction.

Shearer, A. J.↗

Extreme ultraviolet reflection efficiencies of diamond-turned aluminum, polished nickel, and evaporated gold surfaces

Measured reflection efficiencies are presented for flat samples of diamond-turned aluminum, nickel, and evaporated gold surfaces fabricated by techniques suited for EUV telescopes. The aluminum samples were 6.2-cm-diameter disks of 6061-T6, the electroless nickel samples were formed by plating beryllium disks with 7.5-microns of Kanigen. Gold samples were produced by coating the aluminum and nickel samples with 5 strips of evaporated gold. Reflection efficiencies are given for grazing angles in the 5-75 degree range. The results indicate that for wavelengths over about 100 A, the gold-coated nickel samples yield highest efficiencies. For shorter wavelengths, the nickel samples yield better efficiencies. 500 A is found to be the optimal gold thickness.

Malina, R. F.↗

Re-evaporation of condensed matter during the formation of the solar system

From the properties of matter the conclusion is derived that the mineral assemblage characteristic of most chondritic meteorites is not at all what is expected to form directly from solar matter. Rather, the major minerals of the ordinary chondrites have chemical compositions indicative of formation from a medium greatly depleted in hydrogen and somewhat deficient in oxygen relative to solar elemental abundance ratios. The re-evaporation of condensed material, after separation from a large fraction of the gaseous components of solar matter, will lead to a medium of the appropriate composition. Such re-evaporation must have occurred at a time prior to the formation of many primitive meteorites.

Herndon, J. M.↗

Reactively evaporated films of copper molybdenum sulfide

Films of superconducting Chevrel-phase copper molybdenum sulfide CuxMo6S8 were deposited on sapphire substrates by reactive evaporation using H2S as the reacting gas. Two superconducting temperatures (10.0 K and 5.0 K) of the films were found, corresponding to two different phases with different copper concentrations. All films were superconducting above 4.2 K and contained Chevrel-phase compound as well as free molybdenum. The critical current was measured as a function of applied field. One sample was found to deviate from the scaling law found for co-evaporated or sputtered samples, which possibly indicates a different pinning mechanism or inhomogeneity of the sample.

Chi, K. C.↗

Structure and optical properties of evaporated films of the Cr- and V-group metals

Thin films of Cr, Mo, and W rapidly evaporated in high vacuum (5 x 10 to the -7th torr) onto room-temperature substrates show anomalously low reflectance (compared to bulk samples). From electron and X-ray diffraction and electron microscopy, the normal bcc crystal structure is found, but with very fine grains. Columnar grains about 100 A in diameter were separated by a less dense grain-boundary network about 10-A wide. The measured optical conductivity agrees with an inhomogeneous-medium model that assumes the normal crystalline conductivity for the grain interiors, with model parameters that correlate to the observed columnar grain size. In contrast, V and Nb films rapidly evaporated onto room-temperature substrates have the reflectance of bulk crystalline material. On liquid-nitrogen temperature substrates, however, V and Nb have normal bcc crystal structure but with small flat-plate grains, and the same model, with appropriate parameters, accounts for the optical conductivity. The difference between these two groups apparently depends on residual gases segregated at the grain boundaries in the Cr-group films.

Nestell, J. E., Jr.↗

Modeling of growth, evaporation and sedimentation effects on transmission of visible and IR laser beams in artificial fogs

The dense polydisperse aerosol particles in a quiet chamber may spontaneously go through different microphysical processes including gravitational sedimentation, thermal coagulation, and growth or evaporation. In an earlier paper, we presented the results of a parametric study of the combined and separate effects of thermal coagulation and sedimentation on the time dependence of extinction of four visible and IR laser beams traversing an aerosol medium. As a continuation of this series of studies, the separate and combined effects of growth or evaporation and gravitational sedimentation on the time dependence of extinction of the same four visible and IR laser beams traversing in artificial fogs will be reported in this paper. The method of numerically modeling the change of water droplet size distribution with time due to growth/evaporation and the cutoff of larger aerosols due to gravitational sedimentation is described in detail. Factors governing the relative importance of these two processes are discussed. Results of this study show that the relative humidity or ambient temperature is a crucial parameter in determining the optical depth of the water droplet and aerosol media undergoing microphysical processes.

Yue, G. K.↗

Modeling of growth and evaporation effects on the extinction of 1.0-micron solar radiation traversing stratospheric sulfuric acid aerosols

The effects of growth and evaporation of stratospheric sulfuric acid aerosols on the extinction of solar radiation traversing such an aerosol medium are reported for the case of 1.0-micron solar radiation. Modeling results show that aerosol extinction is not very sensitive to the change of ambient water vapor concentration, but is sensitive to ambient temperature changes, especially at low ambient temperatures and high ambient water vapor concentration. A clarification is given of the effects of initial aerosol size distribution and composition on the change of aerosol extinction due to growth and evaporation processes. It is shown that experiments designed to observe solar radiation extinction of aerosols may also be applied to the determination of observed changes in aerosol optical properties, environmental parameters, or the physical and optical characteristics of sulfate aerosols.

Yue, G. K.↗

The structure of evaporating and combusting sprays: Measurements and predictions

The structure of particle-laden jets and nonevaporating and evaporating sprays was measured in order to evaluate models of these processes. Three models are being evaluated: (1) a locally homogeneous flow model, where slip between the phases is neglected and the flow is assumed to be in local thermodynamic equilibrium; (2) a deterministic separated flow model, where slip and finite interphase transport rates are considered but effects of particle/drop dispersion by turbulence and effects of turbulence on interphase transport rates are ignored; and (3) a stochastic separated flow model, where effects of interphase slip, turbulent dispersion and turbulent fluctuations are considered using random sampling for turbulence properties in conjunction with random-walk computations for particle motion. All three models use a k-e-g turbulence model. All testing and data reduction are completed for the particle laden jets. Mean and fluctuating velocities of the continuous phase and mean mixture fraction were measured in the evaporating sprays.

Shuen, J. S.↗

Thermoelectric integrated membrane evaporation water recovery technology

The recently developed Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) offers a highly competitive approach to water recovery from waste fluids for future on-orbit stations such as the Space Operations Center. Low power, compactness and gravity insensitive operation are featured in this vacuum distillation subsystem that combines a hollow fiber membrane evaporator with a thermoelectric heat pump. The hollow fiber elements provide positive liquid/gas phase control with no moving parts other than pumps and an accumulator, thus solving problems inherent in other reclamation subsystem designs. In an extensive test program, over 850 hours of operation were accumulated during which time high quality product water was recovered from both urine and wash water at an average steady state production rate of 2.2 pounds per hour.

Roebelen, G. J., Jr.↗

Evaporation from a partially wet forest canopy

The results of experimental studies of water storage in a Sitka-spruce canopy are presented and analyzed in terms of model simulations of evaporation. Wet-branch cantilever deflection was measured along with meteorological data on three days in August, 1976, to determine the relationship of canopy evaporation to wind speed and (hence) aerodynamic resistance. Two versions of a simple unilayer model of sensible and latent heat transport from a partially wet canopy were tested in the data analysis: model F1 forbids the exchange of heat between wet and dry foliage surfaces; model F2 assumes that this exchange is highly efficient. Model F1 is found to give results consistent with the rainfall-interception model of Rutter et al. (1971, 1975, 1977), but model F2 gives results which are more plausible and correspond to the multilayer simulations of Sellers and Lockwood (1981) and the experimental findings of Hancock and Crowther (1979). It is inferred that the role of eddy diffusivity for water vapor is enhanced relative to momentum transport, and that the similarity hypothesis used in conventional models may fail in the near vicinity of a forest canopy.

Hancock, N. H.↗

Observation of chromospheric evaporation during the Solar Maximum Mission

A study is presented of the upward motions of part of the soft X-ray emitting plasma using data for flares collected in 1980 by the Bent Crystal Spectrometer and the Hard X-ray Burst Spectrometer on the Solar Maximum Mission satellite. Results show that upward motions of the soft X-ray plasma are temporally associated with the build up of the thermal phase of flares and with the period of energy deposition as indicated by the hard X-ray emission. In addition, it is found that the hardness of the hard X-ray spectrum, the evaporation velocity, and the rate of increase of the gradual phase are correlated. It is also possible that the total electron energy deposited in the chromosphere, the peak emission measure of the evaporating plasma, and the peak emission measure of the thermal coronal plasma may also be correlated.

Antonucci, E.↗

Thermal evaporation of spherical clouds - Effects of viscous stresses

The thermal evaporation of a cold spherical cloud embedded in hot gas is analyzed, including the effects of viscous stresses as well as 'saturation' of the conductive heat flux, for the case of equal electron and ion temperatures. The relevant transport properties for an H-He plasma are discussed, including the modification of these transport coefficients when temperature or velocity gradients become large. The fluid-dynamical equations for steady spherical evaporation are given and cast into dimensinless form. Numerical integration of these equations and the results are discussed, emphasizing the novel features of the viscous solutions, astrophysical implications, and uncertainties in the physics.

Giuliani, J. L., Jr.↗

Vapor pressure and evaporation rate of certain heat-resistant compounds in a vacuum at high temperatures

The vapor pressure and evaporation rate of borides of titanium, zirconium, and chrome; and of strontium and carbides of titanium, zirconium, and chrome, molybdenum silicide; and nitrides of titanium, niobium, and tantalum in a vacuum were studied. It is concluded that all subject compounds evaporate by molecular structures except AlB sub 12' which dissociates, losing the aluminum.

Bolgar, A. S.↗

Evaporative coating of a sphere from a point source

To optimize the procedure for evaporating a metal film onto a sphere, calculations of the film thickness distribution for various motions of the sphere have been carried out. These calculations, including shadowing effects of sphere support rods, are presented in this paper. Also, an apparatus and procedure for the evaporative coating of a sphere are described. A comparison of measured thickness with the calculated values is made for one example of sphere motion. The implications of the calculated results for coating techniques are discussed.

Strayer, D. M.↗

Reduction, partial evaporation, and spattering - Possible chemical and physical processes in fluid drop chondrule formation

The major chemical differences between fluid drop chondrules and their probable parent materials may have resulted from the loss of volatiles such as S, H2O, Fe, and volatile siderophile elements by partial evaporation during the chondrule-forming process. Vertical access solar furnace experiments in vacuum and hydrogen have demonstrated such chemical fractionation trends using standard rock samples. The formation of immiscible iron droplets and spherules by in situ reduction of iron from silicate melt and the subsequent evaporation of the iron have been observed directly. During the time that the main sample bead is molten, many small spatter spherules are thrown off the main bead, thereby producing many additional chondrule-like melt spherules that cool rapidly and generate a population of spherules with size frequency distribution characteristics that closely approximate some populations of fluid drop chondrules in chondrites. It is possible that spatter-produced fluid drop chondrules dominate the meteoritic fluid drop chondrule populations. Such meteoritic chondrule populations should be chemically related by various relative amounts of iron and other volatile loss by vapor fractionation.

King, E. A.↗

Thermoelectric Integrated Membrane Evaporation Subsystem operational improvements

A three-man preprototype Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) has been developed to provide high quality water recovery from waste fluids on extended duration space flights. In the most recent effort, a number of improvements have been made to simplify subsystem operation and increase performance. These modifications include changes to the hollow fiber membrane evaporator, the condensing section of the thermoelectric heat pump, and the electronic controller logic and display. This paper describes the results of the test program that was conducted to evaluate the implemented improvements. In addition, an advanced design concept is discussed that will provide lower electrical power consumption, greater water production capacity, lower weight, and a smaller package than the present subsystem configuration.

Dehner, G. F.↗

A swirl flow evaporative cold plate

A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

Niggemann, R. E.↗

Initial phase of chromospheric evaporation in a solar flare

Attention is given to the initial phase of chromospheric evaporation in the solar flare observed by the Solar Maximum Mission's Hard X-ray Imaging Spectrometer, on May 21, 1980. Images of the flaring region in the 3.5-8.0 and 16-30 keV energy bands indicate that both the soft and hard X-ray emissions are localized near the footpoints early in the event, while they are weaker from the rest of the flaring loop system; this implies that there is no heating taking place at the top of the loops, while energy is primarily deposited at their base. Observations of the energy deposition in the chromosphere by electrons accelerated in the flare region to energies above 25 keV furnish further support for an interpretation of plasma upflows as the mechanism responsible for the formation of the soft X-ray flare, identified with chromospheric evaporation.

Antonucci, E.↗