At least 199 records · Page 11

In-Use Passenger Vessel Emission Rates of Black Carbon and Nitrogen Oxides

This study quantified emission factors of black carbon (BC) and nitrogen oxides (NO x ) from 21 engines on in-use excursion vessels and ferries operating in California's San Francisco Bay, including EPA uncertified and Tier 1-4 engines and across engine operating modes. On average, ~60 fuel-based emission factors per engine were measured using a novel combination of exhaust plume capture combined with GPS location and speed data that can be more readily deployed than common portable emissions measurement systems. Here, BC and NO x emission factors (g kg -1 ) were lowest and least variable during fast cruising and highest during maneuvering and docked operation. Selective catalytic reduction (SCR) reduced NO x emissions by ~80% when functional. However, elevated NO x emissions that exceeded corresponding exhaust standards were measured on most Tier 3 and Tier 4 engines sampled, which can be attributed to inactive SCR during frequent low engine load operation. In contrast, BC emissions exceeded the PM emission standard for only one engine, and SCR systems employed as a NO x reduction technology also reduced emitted BC. Using these measured emission factors to compare commuting options, we show that the CO 2 -equivalent emissions per passenger-kilometer are comparable when commuting by car and ferry, but BC and NO x emissions can be several to more than ten times larger when commuting by ferry.

54 ENVIRONMENTAL SCIENCES↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Identifying Light-Duty Vehicle Travel from Large-Scale Multimodal Wearable GPS Data with Novelty Detection Algorithms

Identifying travel mode within travel survey data sets, especially light-duty vehicle (LDV) travel, is foundational, though nontrivial, to travel behavior analysis and fuel consumption estimation. Current travel mode detection approaches require well-sampled and balanced data sets with ground truth travel mode labels. They are rarely applied and validated on large-scale, real-world data sets, which may not satisfy the data requirements. This paper proposes an LDV travel mode detection model as a supplement to current travel mode detection methods, for the case when the training set is highly (and/or completely) unbalanced, to the extent that classical machine-learning approaches become difficult or impossible to deploy. The proposed model uses a novelty detection technique-one-class support vector machines (OCSVMs)-and a novel exhaustive feature extraction (EFE) technique on continuous time series data (i.e., Global Positioning System [GPS] speed profiles) for single-mode trip trajectories. Training and validation of the model are conducted on a large-scale, real-world data set. The proposed method accurately identifies LDV trips from a broad set of multimodal trips by leveraging a wealth of preexisting in-vehicle GPS travel data. Additional sensitivity analysis sheds light on the optimal training size, which will benefit applications limited by highly imbalanced data. The paper also discusses performance comparison with regular machine-learning approaches, the model's robustness, and the potential to extend the proposed model to multimodal prediction.

47 OTHER INSTRUMENTATION↗

LIQUID AIR COMBINED CYCLE

Hybrid integration of thermal energy storage with gas turbines can provide compact, cost-effective, long-duration energy storage while reducing the fuel consumption of dispatchable resources needed for the reliability of renewable dominant electric grids. The Liquid Air Combined Cycle™ (LACC) is a hybrid energy storage system using cryogenic liquid air as an energy storage medium and gas turbine exhaust heat to extract stored energy. The storage tank is charged using liquefaction processes employing electric motor-driven compressors to pressurize the air, heat exchangers to reject heat of compression, and expanders to reduce the temperature and liquefy the air. Proven cryogenic refrigeration processes can be selected based on capital cost (per kg/s of liquid air produced), efficiency (kJ per kg of air produced), and operating factors including startup speed and load following capability. This paper presents results of studies undertaken for the U.S. Department of Energy to evaluate cost and performance tradeoffs for charge and discharge cycle components, optimize charge and discharge cycles, and assess the techno-economic potential of LACC technology.

Conlon, William↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time dependent supervisory control update with FARM using rolling window

This report describes improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution to the dispatch problem involves economically optimal dispatches that satisfy limits on production variables and their rates of variation (explicit constraints) as well as process variables tied to the service life of equipment (implicit constraints). FARM serves to validate or confirm that a HERON solution for explicit constraints also satisfies the implicit constraints. FARM-alpha was released by Argonne National Laboratory in January 2021 followed by FARM-Beta in January 2022 with the latter providing increased flexibility for the user. In this report, FARM-Gamma, the latest version of the code, is described. The major improvement is the implementation of a system identification algorithm based on the Dynamic Mode Decomposition with Control (DMDc) coupled with a “Rolling Window” scheme that allows obtaining linear time-varying state-space models. This feature equips FARM with the most accurate approximation of system dynamics, and it relieves the user from the burden of performing an exhaustive off-line characterization of the dynamics. FARM-Gamma capabilities are assessed by solving the power dispatch problem for a representative IES unit. The simulation times corresponding to the different releases are estimated and compared. These values capture the increasing computational burden of the successively higher fidelity state-space models adopted by FARM-Alpha, FARM-Beta and FARM-Gamma. The code implementation provides significant flexibility, i.e., the user can always select the most suitable version of FARM according to the problem to be solved and the available computational resources. It is anticipated that FARM will play a role in addressing several future IES applications. We outline how it can support the coordinated management and safe operation of a nuclear plant coupled to industrial processes to produce hydrogen and synfuels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Derivation of a Multi-Species Mix Model

Multi-species flow takes place when two or more gases, plasmas or fluids are flowing and interacting with one another through particle collisions, chemical reactions, turbulence, and thermonuclear processes; this list is not exhaustive. It has a wide range of applications in geological, biological and engineering systems. In what follows species refers to different species of atoms or molecules that may or may not be partially or fully ionized. The interactions between these species takes place at an atomic or molecular level. The species are electrically neutral. These are very important points, because the coupling between species that are interacting on a mesoscale level or are immiscible would be very different than what is being considered in this work. In addition, in section 4, we present a heuristic argument to enhance the collisional mean free path to incorporate the effects of turbulent eddies by use of Prandtl’s assumption that the integral scale length of a turbulent boundary layer is proportional to the width of the turbulent layer. This leads to coupling terms that are non-Newtonian, because they are a function of the dynamics of the flow. It is also assumed that the turbulent stress terms are much smaller than the species partial pressures. This may be a good assumption if the species are hot, dense plasmas that exist in ICF targets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Implementation of Smart Materials for Actuation of Traditional Valve Technology for Hybrid Energy Systems

The ever-changing nature of the power industry will require the implementation of hybrid energy systems. Integration of tightly coupled components in hybrids often involves the diversion of exhaust gas flow. An innovative smart material actuation technology is proposed to replace traditional electro-mechanical actuated valve mechanisms with lighter and less expensive actuators. A shape memory alloy (SMA) spring-actuated valve was designed for high-temperature service to demonstrate the promise of smart materials in control valve applications. With SMA springs only generating a maximum force of 3.2 N, an innovative valve design was necessary. To demonstrate the concept, a 3-inch Nominal Pipe Size valve was designed, and 3D printed using the stereolithography technique. Increasing the electrical current to actuate the SMA springs reduced actuation time. The maximum current of 10 A produced the lowest actuation time of 2.85 s, with an observed maximum stroke rate of more than 100 stroke completion %/s (considering actuation open/close as 100% stroke) at the midrange. The final assembly of the valve was estimated to provide a cost reduction of more than 30% and a weight reduction of more than 80% compared to the other available automatic valves in the present market.

36 MATERIALS SCIENCE↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Comparison of Fuel Cycles for Lead-Lithium and Pure Lithium Liquid Metal Walls in a Magnetized Target Fusion Power Plant

General Fusion (GF) is developing an adaptable, commercial fusion power plant based on magnetized target fusion (MTF). The GF approach involves forming a spherical torus of deuterium-tritium plasma in a large (~4 m diameter) cavity formed in liquid metal, and then collapsing that cavity with an array of pneumatic piston drivers. The liquid metal is constantly flowing through the fusion chamber and out to processing systems where tritium and heat will be extracted using tritium extraction technologies and heat exchangers, respectively. Here, this study focuses on two candidate designs for the liquid metal blanket and first wall material for the General Fusion Magnetized Target Fusion (GF MTF) power plant and assesses their impact on the tritium fuel cycle. The first candidate is the lead lithium eutectic (LLE) and the second candidate is pure lithium (Li). It was found that the main differences between LLE and Li designs are the extraction technologies required to remove tritium from the blanket and the amount of tritium and its distribution within the facility. More than 80% of the in-process tritium inventory for the LLE design is contained in the isotope separation system, while for the Li design, over 60% of the in-process tritium inventory is contained within the blanket material. This is due to significant tritium retention by Li. For the Li blanket, the burden of tritium processing rests on the blanket extraction technology rather than the traditional exhaust processing route. Thus, the blanket extraction technology is a main driver of tritium inventory in the Li system and determines the subsequent interface with the tritium processing plant.

General Fusion↗

Savannah River National Laboratory – General Fusion 2023 INFUSE Report (Rev.1)

This report describes the results from an INFUSE research project, where Savannah River National Laboratory (SRNL) in collaboration with General Fusion (GF) used process modeling to understand and optimize commercial power plant (CPP) fuel cycle designs based on parameters provided by GF. The study primarily focused on two candidate fuel cycles with different blanket materials, one with a lead lithium eutectic (LLE) blanket and the other with a pure lithium (Li) blanket. LLE benefits from a low melting point, favorable neutronics, and lower reactivity, but liquid lithium has the potential for higher tritium breeding ratios (TBR) and does not poison the plasma as a high Z contaminant. It was found that the main differences between LLE and Li designs are the extraction technologies required to remove tritium from the blanket and the amount of tritium and its distribution within the facility. More than 80% of the in-process tritium inventory for the LLE design is contained in the isotope separation system, while for the Li design, over 60% of the in-process tritium inventory is contained within the blanket material. This is due to significant tritium retention by Li. For the Li blanket, the burden of tritium processing rests on the blanket extraction technology rather than the traditional exhaust processing route. Thus, the blanket extraction technology is a main driver of tritium inventory in the Li system and determines the subsequent interface with the tritium processing plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Hybrid Heavy-Duty Diesel Power System for Off-Road Applications - Concept Definition

A multi-year Power System R&D project was initiated with the objective of developing an off-road hybrid heavy-duty concept diesel engine with front end accessory drive-integrated energy storage. This off-road hybrid engine system is expected to deliver 15-20% reduction in fuel consumption over current Tier 4 Final-based diesel engines and consists of a downsized heavy-duty diesel engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy recovery through both mechanical (high speed flywheel) and electrical systems. The first year of this project focused on the definition of the hybrid elements using extensive dynamic system simulation over transient work cycles, with hybrid supervisory controls development focusing on energy recovery and transient load assist, in Caterpillar’s DYNASTY™ software environment. Three key off-road applications were the focus of the hybrid concept definition with an aim of understanding the system’s modular capability for the diverse off-road heavy-duty market. Core engine performance 1D and 3D simulations isolated the efficiency contributions from the downsized engine, turbocompounding, and in-cylinder thermal barrier coatings. A fuel consumption improvement range of 14 to 24% was predicted, resulting in successful project progression to the design and experimental validation phase. Furthermore, an overview of the experimental engine and hybrid system status concludes the discussion along with the multi-year project’s next steps.

33 ADVANCED PROPULSION SYSTEMS↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Impact of Fuel Properties on the Combustion of Late Post Injections used for Aftertreatment Thermal Management

Typical calibration for catalyst thermal management for compression-ignition engines involves delaying the post-injection into the expansion stroke. Reduced work extraction due to the late heat release event is used to increase the exhaust gas temperature to shorten the time associated with reaching optimal temperatures for aftertreatment systems. Shorter catalyst heat-up time can simultaneously reduce tail-pipe emissions and the typical fuel penalties associated with this mode of operation. In this study, the effects of volatility, reactivity, and oxygen content of the fuel on combustion stability and emissions were studied in a light-duty single-cylinder research engine. Blends of iso-octane/ n-heptane and farnesane/ 2,2,4,4,6,8,8-heptamethylnonane were used to study the impacts of volatility and reactivity. At constant reactivity, little to no variation in combustion performance was observed due to differences in volatility. On the other hand, increased reactivity improved combustion stability and efficiency at late injection timings (+24 CAD). The combined effect of increase in chemical reactivity and oxygen content was analysed by comparing the baseline #2 diesel operation with two blends of mono-ethers and #2 diesel to achieve cetane numbers (CNs) of 45 and 55, and a pure blend of mono-ether components with CN > 100. Fuels with higher reactivity and oxygen content were found to reduce engine-out hydrocarbon and carbon mono-oxide emissions while also achieving stable combustion at post-injection timings later than those achievable with diesel fuel. The pure ether-blend had the latest achievable post-injection timing (≥+26 CAD) while still maintaining stable combustion. At similar combustion stability, the pure ether blend was found to have 2.8% higher combustion efficiency and 4.3% higher thermal efficiency than the baseline diesel. The ether-diesel blends at CN45 and CN55 were found to have 1.8% higher combustion efficiency than baseline diesel. The results demonstrate that fuels with increased reactivity can increase combustion efficiency, reducing carbon monoxide and hydrocarbon emissions, while maintaining similar exhaust temperature and combustion stability compared to baseline diesel. Further greenhouse gas benefits can also be realized as the mono-ether bioblendstocks show potential for >50% reduction in greenhouse gas emissions relative to diesel fuel based on their production method.

99 GENERAL AND MISCELLANEOUS↗

Toward Accelerating Discovery via Physics-Driven and Interactive Multifidelity Bayesian Optimization

Both computational and experimental material discovery bring forth the challenge of exploring multidimensional and often nondifferentiable parameter spaces, such as phase diagrams of Hamiltonians with multiple interactions, composition spaces of combinatorial libraries, processing spaces, and molecular embedding spaces. Often these systems are expensive or time consuming to evaluate a single instance, and hence classical approaches based on exhaustive grid or random search are too data intensive. This resulted in strong interest toward active learning methods such as Bayesian optimization (BO) where the adaptive exploration occurs based on human learning (discovery) objective. However, classical BO is based on a predefined optimization target, and policies balancing exploration and exploitation are purely data driven. In practical settings, the domain expert can pose prior knowledge of the system in the form of partially known physics laws and exploration policies often vary during the experiment. Here, we propose an interactive workflow building on multifidelity BO (MFBO), starting with classical (data-driven) MFBO, then expand to a proposed structured (physics-driven) structured MFBO (sMFBO), and finally extend it to allow human-in-the-loop interactive interactive MFBO (iMFBO) workflows for adaptive and domain expert aligned exploration. These approaches are demonstrated over highly nonsmooth multifidelity simulation data generated from an Ising model, considering spin–spin interaction as parameter space, lattice sizes as fidelity spaces, and the objective as maximizing heat capacity. Detailed analysis and comparison show the impact of physics knowledge injection and real-time human decisions for improved exploration with increased alignment to ground truth. Here, the associated notebooks allow to reproduce the reported analyses and apply them to other systems.

97 MATHEMATICS AND COMPUTING↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.