Search NASA⌕ Search

SEARCH · Search NASA

Results for “Effective thermal conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). An inner vessel receives liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including upper and lower guard chambers and middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid allowing easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Below Ambient and Cryogenic Thermal Testing

Methods and apparatus for the testing of below-ambient temperature thermal insulation systems have been developed based on boiloff calorimetry. Boiloff calorimetry provides a direct measure of heat flow for below-ambient temperature conditions. The effective thermal conductivity (ke) and heat flux (q) of a test specimen are calculated for a fixed environmental condition (warm boundary temperature; cold boundary temperature; ambient or vacuum pressure). Through its heat of vaporization, liquid nitrogen (LN2) serves as the energy meter. Different apparatus have been built for flat-plate, cylindrical, and pipeline test specimens. Boundary temperatures can range from 353 K down to 77 K (80 C to -196 C). By interposing different insulation layers on the cold boundary, the cryogenic boiloff method is suitable for a wide range of below-ambient temperature applications. A cylindrical apparatus, Cryostat-100, as well as the pipeline test apparatus, Cryostat-P100, are thermally guarded and directly measure absolute thermal performance in watts. Pipe insulation systems can be mechanical, double-walled, or vacuum-jacketed including materials such as foams, cellular glass, aerogel blankets, clam-shell panels, and multilayer insulation. Two test pipelines, 12-meter-long, are mounted between two cold box assemblies. The test pipeline diameter is from 25-mm to 76-mm while the maximum outside diameter including insulation is up to 204-mm. The cold pipe tester design and test methods are discussed, as well as results for select thermal insulation materials. Progress toward a comparative type, bench-top cold pipe tester (Cryostat-P200) is also discussed.

Fesmire, James E.↗

Aerogel-Based Insulation Materials for Cryogenic Applications

Many different aerogel-based materials are now being used in thermal insulation systems for cryogenic applications. These materials include flexible composite blankets, bulk-fill particles, and polymer composites in both evacuated and non-evacuated environments. In ambient environments, aerogels provide superior thermal performance compared to conventional polymeric foam and cellular glass insulations while offering unique advantages in avoiding problems with weathering, moisture, and mechanical damage. Aerogels are also used as spacer materials in multilayer insulation systems. These layered systems provide combined structural-thermal capability for cryogenic systems in either vacuum-jacketed or externally-applied insulation designs. Test data (effective thermal conductivity) include a wide range of both commercial and experimental aerogel materials. Testing was performed using laboratory cryostats and standard methods including full range vacuum (from ambient pressure to high vacuum) and boundary temperatures 293 K and 78 K. Examples of aerogel-based insulation systems are given for both evacuated and non-evacuated applications.

heat transfer↗

Aerogel-Based Insulation Materials for Cryogenic Applications

Many different aerogel-based materials are now being used in thermal insulation systems for cryogenic applications. These materials include flexible composite blankets, bulk-fill particles, and polymer composites in both evacuated and non-evacuated environments. In ambient environments, aerogels provide superior thermal performance compared to conventional polymeric foam and cellular glass insulations while offering unique advantages in solving problems with weathering, moisture, and mechanical damage. Aerogels are also used as spacer materials in multilayer insulation systems. These layered systems provide combined structural-thermal capability for cryogenic systems in either vacuum-jacketed or externally-applied insulation designs. Test data (effective thermal conductivity) include a wide range of both commercial and experimental aerogel materials. Testing was performed using laboratory cryostats and standard methods including full range vacuum (from ambient pressure to high vacuum) and boundary temperatures 293 K and 78 K. Examples of aerogel-based insulation systems are given for both evacuated and non-evacuated applications.

aerogel layered composites↗

Overview of MultiLayer Metal Insulation Development for Small Stirling Convertors at NASA Glenn Research Center

A small Stirling convertor is currently under development at the NASA Glenn Research Center to produce one watt of electrical power from eight watts of heat. Previous radioisotope power systems made use of the General-Purpose Heat Source (GPHS) which produces 250 watts of heat but is unsuitable for a one-watt Stirling convertor. The only other qualified heat source available is the Light-Weight Radioisotope Heating Unit (LWRHU), which produces one watt of heat and is primarily used to provide heat to electronics and instrumentation to maintain their appropriate operating temperature. Unfortunately, the LWRHU has a heat flux of 272 W/meters squared compared to the GPHS heat flux of 6000 W/m2 which greatly increases the demands on the insulation to ensure that enough of the heat produced is available to the convertor and not lost to the environment. An analysis was performed that showed that the insulation must have an effective thermal conductivity of 0.005 W/m·K or better for the system to function. A multi-layer metal insulation package was designed and a prototype was fabricated and tested to investigate the feasibility of this design. While the prototype did not meet the requirements perfectly, the lessons learned are being used to generate an improved thermal model using the test data so that a second iteration can developed that will meet the performance requirements with a much higher confidence.

Daniel D Goodell↗

Lightweight thermal insulation for Mars surface applications

The intent of this paper is to present a novel insulation design approach, to report the comparison testing against fiberglass batt material, and to summarize the design parameters such as effective thermal conductivity, mass, cost, and delivery time for the fiberglass batt material and this new insulation.

carbon↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Gas Phase Pressure Effects on the Apparent Thermal Conductivity of JSC-1A Lunar Regolith Simulant

Gas phase pressure effects on the apparent thermal conductivity of a JSC-1A/air mixture have been experimentally investigated under steady state thermal conditions from 10 kPa to 100 kPa. The result showed that apparent thermal conductivity of the JSC-1A/air mixture decreased when pressure was lowered to 80 kPa. At 10 kPa, the conductivity decreased to 0.145 W/m/degree C, which is significantly lower than 0.196 W/m/degree C at 100 kPa. This finding is consistent with the results of previous researchers. The reduction of the apparent thermal conductivity at low pressures is ascribed to the Knudsen effect. Since the characteristic length of the void space in bulk JSC-1A varies over a wide range, both the Knudsen regime and continuum regime can coexist in the pore space. The volume ratio of the two regimes varies with pressure. Thus, as gas pressure decreases, the gas volume controlled by Knudsen regime increases. Under Knudsen regime the resistance to the heat flow is higher than that in the continuum regime, resulting in the observed pressure dependency of the apparent thermal conductivity.

Yuan, Zeng-Guang↗

Properties of Graphite Fiber Reinforced Copper Matrix Composites for Space Power Applications

The thermal and mechanical properties of pitch-based graphite fiber reinforced copper matrix (Gr/Cu) composites usable for space applications such as radiator fins were investigated. Thermal conductivity was measured as a function of fiber volume fraction and architecture. Results showed for unidirectional P-100 Gr/Cu composites, the longitudinal thermal conductivity was nearly independent of fiber volume fraction. Transverse thermal conductivities (perpendicular to the fibers) were strongly affected by the fiber volume fraction with higher volume fractions resulting in lower thermal conductivities. The effect of architecture on thermal conductivity followed the cosine squared law for simple architectures. Insufficient data are available currently to model more complex architectures, but adding fibers in the direction of the heat flow increases the thermal conductivity as low conductivity plies are supplemented by high conductivity plies. Thermal expansion tests were conducted on the Gr fibers and Gr/Cu composites. The results show a considerable thermal expansion mismatch between the fibers and the Cu matrix. The longitudinal thermal expansion showed a strong dependence on the architecture of the Gr/Cu composites. The composites also show a thermal expansion hysteresis. The hysteresis was eliminated by an engineered interface. Mechanical testing concentrated on the dynamic modulus and strength of the composites. The dynamic modulus of the Gr/Cu composites was 305 GPa up to 400 C, a value equivalent to Be. The strengths of the composites were less than expected, but this is attributed to the poor bond across the interface between the Gr fibers and Cu matrix. Testing of composites with an engineered interface is expected to yield strengths nearer the values predicted by the rule of mixtures.

Ellis, David L.↗

A Study of Space Environment Effect on Highly Thermally Conductive Hybrid Carbon Fiber Polymer Composites

A set of novel highly thermally conductive hybrid carbon fiber (CF) polymer composites has been developed for lightweight thermal radiator applications in space missions. This study investigates the effects of the space environment on these materials following exposure in low-Earth orbit (LEO) during the Materials International Space Station Experiment (MISSE)-17 flight mission, where samples experienced 159 days of combined atomic oxygen (AO), ultraviolet (UV) radiation, high vacuum, space radiation and thermal cycling. Post-flight characterization included weight loss, surface morphology, thermo-optical properties, molecular structures, glass transition temperature, thermal degradation and thermal conductivity analyses. The pyrolytic graphite sheet (PGS) samples exhibited negligible weight loss, stable thermo-optical property, and only minor oxidation signature on the exposed surface. Although AO erosion of the epoxy polymer matrix was evident, carbon nanotube (CNT)-infused PGS/CF epoxy composites retained high thermal emissivity and preserved their high thermal conductivities. These results demonstrate that the novel highly thermally conductive hybrid CF composites possess strong environmental resilience and are promising candidates for lightweight thermal radiators and thermal management components in future space exploration missions.

Space Environment↗

Effect of variable thermal conductivity on isotherms in Bridgman growth

A change in thermal conductivity associated with melting or solidification can have a profound influence on the isotherms near the solidification interface if the material is being directionally solidified in an ampoule whose walls carry a substantial portion of the heat. This analysis was prompted by a recent discovery that the thermal conductivity of Hg(1-x)CD(x)Te increased dramatically as the material is heated above the solidus curve. An illustrative example is shown in which the sample is approximated as an infinite cylinder with constant but diffferent thermal properties in the solid and melt. The boundary conditions are fixed on the surface by a conductive ampoule in a two-zone Bridgman furnace with an adiabatic region separating the two zones. The effect of the adiabatic zone in this case is to intensify the curvature of the interface rather than to lessen it.

Naumann, R. J.↗

Modeling heat transport processes in enhanced geothermal systems: Validation study from EGS Collab Experiment 1

Heat recovery from enhanced geothermal systems (EGS) is a complex process involving heat transport in both fracture networks and rock formations. A comprehensive understanding of and the ability to model the underlying heat transport mechanisms is important for the success of EGS but remains challenging in practice due to the generally insufficient characterization of EGS reservoirs. In the present study, we analyze an extensively monitored intermediate-scale EGS field experiment performed in a well-characterized testbed. The high-resolution, high-quality measurements from the field experiment enable the development of a high-fidelity model incorporating a well-constrained fracture network. Based on the field experiment, we investigate the complex heat transport processes in an EGS-relevant environment and validate the capability of a numerical approach in simulating these inherently coupled heat transport processes. A series of numerical simulations were performed to study the effects of different heat transport mechanisms, including thermal convection with fracture flow, thermal conduction in rock formations, and the Joule-Thomson effect. The agreement of thermal responses between field measurements and simulation results indicates that our numerical approach can appropriately model the heat transport processes pertaining to heat recovery from EGS reservoirs.

Wu, Hui↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Thermal diffusivity and thermal conductivity of SiC composite tubes: the effects of microstructure and irradiation

Cladding thermal conductivity is an important physical property in assessing the performance of silicon carbide (SiC)-cladded fuels for nuclear reactors. However, there is a significant lack of reliable data, particularly for irradiated materials, because the geometry complicates the measurement. This study investigates the thermal diffusivity of coupons with a curvature, machined from SiC fiber–reinforced SiC matrix composite tubes, with and without neutron irradiation under light water reactor–relevant temperature and dose conditions. The tested materials included full composite and duplex SiC composite tubes. The measurements were conducted using a modern flash diffusivity apparatus. The analyzed area on the specimen during diffusivity testing was reduced for improved measurement accuracy due to sample curvature. Post-irradiation measurements showed that the effects of neutron irradiation on thermal conductivity (e.g. thermal defect resistivity) are different between SiC composite plates versus tubes. The difference was explained by higher matrix density of the tube than the plate. This study provides reliable thermal properties of prototypic SiC composite tubes useful for fuel performance modeling of SiC-based cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Some physical implications of recent solar wind measurements

The physical implications of the existence at about 1 AU of a quiet solar wind particle flux about 90 percent larger than that suggested in the past is investigated within the framework of the two-fluid solar wind model equations. During the spherically symmetric radial expansion of the quiet solar wind, the particle flux is conserved quantity. It is found that a pure collisional two-fluid model provides good particle density and streaming velocity at 1 AU, but predicts too large an electron temperature and too small a proton temperature. When noncollisional contributions to the transport coefficients are incorporated in the model equations, a complete satisfactory agreement with the available observations is obtained. Upper limits to the effective coupling between electrons and protons, as well as to the effective proton thermal conductivity, and both upper and lower limits to the effective electron thermal conductivity in the quiet solar wind, required to provide agreement with observations, are given.

Cuperman, S.↗