Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated On-Board Charger for Dual Motor Based Electric Vehicle Power Train

This paper presents an integrated on-board charger for dual motor based electric vehicle (EV) power train with silicon carbide semiconductor switch-based traction inverters. The proposed charger architecture reconfigures the traction inverters to be used in the battery charging mode, thereby eliminating several high frequency switches and their accessories. The motor windings are reused as line inductors for the power factor correction (PFC) rectifier stage in the charging mode thereby reducing the requirements of magnetic components. The architectures reduce the cost, weight, and volume of the EV power train. Simulation results are presented to demonstrate the working principle of the proposed architecture.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Hybrid electric vehicle and method of operating engine of the same

A hybrid electric vehicle (HEV) for multiple operation modes includes: a gasoline diffusion flame (GDF) combustion engine configured to perform gasoline diffusion flame combustion; a motor-generator operatively connected to the GDF combustion engine and configured to selectively drive the HEV with electric power of a battery or generate electric power to charge the battery; and a multi-mode controller including a processor and configured to receive operating conditions of the GDF combustion engine and the motor-generator and define a plurality of mode operating regions based on the received operating conditions. In particular, the plurality of mode operating regions includes: an electric vehicle (EV) only mode operating region, a GDF mode operating region where the GDF combustion engine operates and drives the HEV while the motor-generator stops, and a GDF+EV mode operating region where the motor-generator assists the operation of the GDF combustion engine to drive the HEV.

Bourcier, Mark↗

Power Solitons in Inverter-based Electric Energy Systems: Observation, Analysis and Implications

The discovery of an unfamiliar class of nonlinear energy waves in electric energy systems with dominating coupled inverter-based energy resources has been reported in a recent research project. Whenever there are slight but persistent differences among the reference signals used by inverters in pulse-width modulation, i.e., a weak group modulation instability condition, the unfamiliar energy waves appear, which contain not only the familiar frequency components present in electric power systems but also self-organized components in the ultra-high frequency region of the energy spectrum. These components are found to be exploding solitary waves with concentrated energy masses, hence we call them power solitons. This paper explains the work of the discovery reported, and the implications of the presence of power solitons for grid integration of inverter-based resources and power system protection.

14 SOLAR ENERGY↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

Advanced Anode for Internal Reforming and Thermal Management in Solid Oxide Fuel Cells

Solid oxide fuel cell (SOFC) is an efficient and clean electrical power generation system compared to conventional combustion based technologies with energy efficiency reaching as high as 85-90% in co-generation mode (electricity and heat). Other advantages of SOFCs are hybridization, modularity of construction, small CO 2 foot print per kWh of generated electricity and fuel flexibility. Hydrocarbons present in the gaseous fuel is utilized in SOFCs by internal or external reforming. There are two different internal reforming concepts: Direct Internal Reforming (DIR) and Indirect Internal Reforming (IIR). For DIR operation, the endothermic reforming reaction and the exothermic reaction from the oxidation reaction are operated together in the single unit eliminating the requirement for a separate fuel reformer. This configuration also simplifies the overall system design, making SOFC more attractive and efficient means of producing electrical power. The main advantage of the DIR type of operation is that the H 2 or CO consumption by the electrochemical reaction could directly promote the conversion of methane at the anode side of the fuel cell resulting in high conversion and high efficiency. The DIR operation, however, requires an anode material that has desired dual catalytic (hetero and electro) properties for reforming reaction and electrochemical reactions. The anode materials also need to remain resistant to carbon formation at the operating temperature and atmosphere with stable cell performance. Another requirement is to match the reforming reactions and electrochemical reactions to avoid local cooling or overheating, which can result in mechanical failure due to thermally induced stresses. Direct internal reforming (DIR) of hydrocarbon fuels simplifies the overall SOFC system design making it more attractive and efficient for producing electrical power. Low cost alloy anodes for distributed internal reforming of methane and other hydrocarbon fuels offer increased fuel-flexibility, reliability, and long term performance stability of solid oxide fuel cells (SOFC). The research program examined modification of the chemical compositions and microstructure of high entropy alloy (HEA) anode materials using thermochemical calculations and process simulation and modeling to achieve distributed reforming over the entire anode to eliminate hot zones. Cell fabrication and testing of the HEA anodes using button cell configuration has been performed to demonstrate the advantages of new anode over traditional Ni-YSZ anodes for distributed reforming and carbon free operation. Technical accomplishments include identification and synthesis of HEA carbon-resistant anode, demonstration of reduction in reforming rate confirmed by GC and modelling data validating effectiveness for thermal management in cell/stacks, electrochemical testing of HEA anode in single cell (HEA-GDC||YSZ||LSM-YSZ) and Characterization of pretest and posttest anode materials by TEM and SEM-EDS confirming carbon-free operation.

30 DIRECT ENERGY CONVERSION↗

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

Front-End Engineering Design Study for Retrofit Post-Combustion Carbon Capture on a Natural Gas Combined Cycle Power Plant

The objective of the project is to conduct a Front-End Engineering Design (FEED) study to determine the technical and economic feasibility of installing a retrofit, post-combustion, carbon capture facility on a commercially operating, natural gas-fired, combined cycle (NGCC) power plant. The Electric Power Research Institute (EPRI), California Resources Corporation (CRC), and Fluor Corporation used Fluor's Econamine FG Plus SM (EFG+) conducted the FEED study for capturing CO 2 produced by CRC's 550 MWe Elk Hills Power Plant (EHPP), located in the Elk Hills Oil Field near Tupman, Kern County, California. The EHPP was commissioned in 2003 and is powered by two General Electric 7FA gas turbines, with two heat recovery steam generators (HRSGs) providing steam to a General Electric D11 steam turbine. The target capture amount is 4,000 tonnes CO 2 /day for use in either enhanced oil recovery or dedicated geological saline storage located on CRC property at or nearby EHPP. This CO 2 is captured from a combination of the CO 2 emitted from the flue gas from EHPP and the flue gas generated from a natural gas-fired auxiliary boiler that supplies steam to the EFG+ process.

03 NATURAL GAS↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Impacts of Spatial Resolution in a High-Fidelity Capacity Expansion Model: An ERCOT Case Study

Capacity expansion models are important tools in examining the evolution of the electric power sector. Embedded in these tools are many modeling choices with consequential impacts on computational burden and associated analysis. In this study, we adjust the spatial resolution of the Regional Energy Deployment System (ReEDS) to understand the implications of higher-fidelity modeling on energy system projections and model solve times. The native ReEDS regions capture the contiguous United States in 134 balancing areas whereas the regions in the higher-resolution version are defined by over 3,000 U.S. counties. Using both resolutions, we conduct a case study of the Texas Interconnection (The Electric Reliability Council of Texas [ERCOT]) to explore differences in model projections and to inform appropriate applications of high spatial resolution in a large-scale, applied capacity expansion model.

county↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Dynamic/Steady-State Tool With Protection Simulation for Cascading-Outage Analysis of Extreme Events in Power Systems

The bulk electric power grid is subject to vulnerabilities from component outages, which in certain combinations (extreme events) might lead to cascading outages. Some of these outages can be severe enough to trigger brownouts and blackouts. Much is known about mitigating the first few failures near the beginning of a cascade, but there are few established methods and tools for directly analyzing the risks of cascading component outages over a longer time scale. Current power system tools have limited ability to perform detailed and accurate cascading-outage analysis, which could be computationally intensive. The Dynamic Contingency Analysis Tool (DCAT) enables power system planning engineers to more realistically assess the consequences of extreme contingencies and potential cascading events across their systems and interconnections. DCAT has several unique features: (i) detailed hybrid dynamic and steady-state analysis of power systems to mimic real-world cascading outages, (ii) detailed modeling of protection systems embedded in the dynamic simulation, (iii) simulation of corrective action after transients, (iv) simulation of islanding , and (v) high-performance computing capability to simulate a large number of contingencies in a reasonable time. DCAT outputs will help find technically sound solutions to reduce the risk of cascading outages. This paper provides details of DCAT methodology and shows its capabilities with extreme events on real-world cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Power Density Cost-Effective MVDC Aircraft Cable

To make the power density of electric aircraft closer to conventional aircraft, an electric power system (EPS) with high power delivery and low system mass is necessary. As an essential component of aircraft EPS, cables are necessary to transmit power from one node to another. Virginia Tech will design high-power density, cost-effective ±5 kV cables for twin-aisle all-electric aircraft. Innovations include conductors with increased current-carrying capacity and a multilayer, multifunctional insulation system made of exceptionally high thermal conductivity materials. Designed for DC voltage, the new insulator will allow fewer partial discharge events and provide improved electromagnetic interference protection.

42 ENGINEERING↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

Load following power generation and power storage using REP and PEM technology

A hydrogen generation system for generating hydrogen and electrical power includes a power supply, a reformer-electrolyzer-purifier (REP) assembly including at least one fuel cell including an anode and a cathode separated by an electrolyte matrix, at least one low temperature fuel cell, and a hydrogen storage. The at least one fuel cell is configured to receive a reverse voltage supplied by the power supply and generate hydrogen-containing gas in the anode of the at least one fuel cell. The at least one low temperature fuel cell is configured to receive the hydrogen-containing gas output from the REP assembly. The at least one low temperature fuel cell is configured to selectably operate in a power generation mode in which the hydrogen-containing gas is used to generate electrical power and a power storage mode in which the hydrogen-containing gas is pressurized and stored in the hydrogen storage.

Jahnke, Fred C.↗