Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Superconducting wires for quench detection

A superconducting device includes a first superconducting wire configured to carry a first current in a superconducting state, and to generate thermal energy upon occurrence of a hot spot during conduction. The device includes a second superconducting wire, thermally coupled to and electrically isolated from the first superconducting wire. The second superconducting wire is configured to conduct a second current in a superconducting state below, but sufficiently near its critical surface to be quenched to a non-superconducting state upon conduction of the thermal energy from the first superconducting wire.

Van Der Laan, Daniel Cornelis↗

Downhole to surface communications platform for drilling applications

A drilling assembly for downhole to surface communications is provided. The drilling assembly includes a series of pipe segments coupled in fluid communication between a slip ring assembly and an end pipe portion. The slip ring assembly is coupled in data and fluid communication with the pipe segments. A surface communications link is in data communication with the drilling assembly via the slip ring assembly. An end pipe portion is coupled with the drilling assembly that includes an electronics assembly with electronic components for transferring data to the slip ring assembly via the drilling assembly. A drill bit is operably coupled with the end pipe portion for drilling a borehole. Each pipe segment includes an outer conductor portion, a hollow inner conductor portion, and a dielectric portion for electrical isolation between the outer conductor portion and the inner conductor portion.

Su, Jiann-Cherng↗

Electrical connectors including glass seals and methods of fabrication

An electrical connector comprises an outer shell, at least one pin, and an insulating seal. The outer shell includes at least one side wall defining a cavity and having an inner surface. The outer shell is formed from electrically conductive material. The pin is positioned within the cavity and is also formed from electrically conductive material. The insulating seal is configured to provide electrical isolation of the pin and fills the cavity between the inner surface of the side wall and the pin. The insulating seal is formed from glass doped with a transition metal oxide.

Eichorst, Dennis J.↗

MEMS nanopositioner and method of fabrication

A microelectromechanical (MEMS) device is provided. The MEMS device comprises a substrate and a movable structure flexurally connected to the substrate, capable of moving in relation to the substrate, wherein the movable structure further comprising two or more segments having at least one mechanical connection between said segments to provide structural integrity of the moving structure; and wherein the at least one mechanical connection electrically isolates at least two segments.

Moheimani, Seyed Omid Reza↗

Community Microgrid Assistance Partnership (C-MAP)

The Community Microgrid Assistance Partnership (C-MAP) provides funding, access to technical experts, and educational resources to energy providers in remote and electrically isolated areas to help them build, operate, and enhance microgrid systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrically conductive fibers thermally isolate temperature sensor

Mounting assembly provides thermal isolation and an electrical path for an unbacked thermal sensor. The sensor is suspended in the center of a plastic mounting ring from four plastic fibers, two of which are coated with an electrically conductive material and connected to electrically conductive coatings on the ring.

De Waard, R.↗

Hy-wire and fast electric field change measurements near an isolated thunderstorm, appendix C

Electric field measurements near an isolated thunderstorm at 6.4 km distance are presented from both a tethered balloon experiment called Hy-wire and also from ground based fast and slow electric field change systems. Simultaneous measurements were made of the electric fields during several lightning flashes at the beginning of the storm which the data clearly indicate were cloud-to-ground flashes. In addition to providing a comparison between the Hy-wire technique for measuring electric fields and more traditional methods, these data are interesting because the lightning flashes occurred prior to changes in the dc electric field, although Hy-wire measured changes in the dc field of up to 750 V/m in the direction opposite to the fair weather field a short time later. Also, the dc electric field was observed to decay back to its preflash value after each flash. The data suggest that Hy-wire was at the field reversal distance from this storm and suggest the charge realignment was taking place in the cloud with a time constant on the order of 20 seconds.

Holzworth, R. H.↗

Fuel Cell/Electrochemical Cell Voltage Monitor

A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

Vasquez, Arturo↗

A disturbance isolation controller for the solar electric propulsion system flight experiment

A disturbance isolation controller (DIC) is developed for a simplified model of the solar electric propulsion system (SEPS) flight experiment which consists of a rigid Sperry gimbal torquer (AGS) mounted to a rigid orbiter and the SEPS solar array (rigid) end mounted to the AGS. The main purpose of the DIC is to reduce the effects of orbiter disturbances which are transmitted to the flight experiment. The DIC uses an observer, which does not require the direct measurement of the plant inputs, to obtain estimates of the plant states and the rate of the plant states. The state and rate of state information is used to design a controller which isolates disturbances from specified segments of the plant, and for the flight experiment, the isolated segment is the SEPS solar array.

Waites, H. B.↗

Enhancing Fault Isolation for Health Monitoring of Electric Aircraft Propulsion by Embedding Failure Mode and Effect Analysis into Bayesian Networks

This paper describes a fault isolation approach for electric powertrains of unmanned aerial vehicles. The approach leverages the combination of failure mode and effect analysis (FMEA) and Bayesian networks, thus introducing depend-ability structures into a diagnostic framework. Faults and failure events from the FMEA are mapped within a Bayesian network, where network edges replicate the links embedded within FMEAs. This framework helps the fault isolation process by identifying the probability of occurrence of specific faults or root causes given evidence observed through sensor signals. The framework is applied to an electric power-train system of a small, rotary-wing unmanned aerial vehicle, demonstrating how a Bayesian network enhanced by FMEA helps disambiguate between root causes of incipient failures, which would otherwise be considered as equally probable.

Fault Isolation↗

Electrical filtering in gerbil isolated type I semicircular canal hair cells

1. Membrane potential responses of dissociated gerbil type I semicircular canal hair cells to current injections in whole cell current-clamp have been measured. The input resistance of type I cells was 21.4 +/- 14.3 (SD) M omega, (n = 25). Around the zero-current potential (Vz = -66.6 +/- 9.3 mV, n = 25), pulsed current injections (from approximately -200 to 750 pA) produced only small-amplitude, pulse-like changes in membrane potential. 2. Injecting constant current to hyperpolarize the membrane to around -100 mV resulted in a approximately 10-fold increase in membrane resistance. Current pulses superimposed on this constant hyperpolarization produced larger and more complex membrane potential changes. Depolarizing currents > or = 200 pA caused a rapid transient peak voltage before a plateau. 3. Membrane voltage was able to faithfully follow sine-wave current injections around Vz over the range 1-1,000 Hz with < 25% attenuation at 1 kHz. A previously described K conductance, IKI, which is active at Vz, produces the low input resistance and frequency response. This was confirmed by pharmacologically blocking IKI. This conductance, present in type I cells but not type II hair cells, would appear to confer on type I cells a lower gain, but a much broader bandwidth at Vz, than seen in type II cells.

Non-NASA Center↗

Electric-field enhanced water-dissociation catalysis on oxide surfaces

Ion-transfer reactions in the presence of electric fields are ubiquitous in (bio/electro)chemical systems and catalysis, yet the impact of the electric field is poorly understood. Here, we use bipolar membranes (BPMs) to isolate electric-field-driven non-faradaic water dissociation (WD: H 2 O → H + + OH − ) on catalytic surfaces. We find the catalyst layer's ionic properties dictate both the transport and kinetic processes within the BPM. The role of these properties are explored via a series of membrane architectures, and catalyst poisoning experiments, and the corresponding current–voltage and impedance responses. Arrhenius analyses show that an acidic graphene-oxide (GO x ) catalyst layer gives rise to low interfacial H 2 O entropy in the heterojunction, illustrated via a >100 fold increase in the Arrhenius prefactor relative to baseline TiO 2 measurements. Furthermore, ∼50% of the applied driving force goes towards reducing the apparent enthalpic activation barrier in the case of GO x , while other metal-oxide catalysts have enthalpic barriers independent of driving force. This analysis demonstrates a new mechanistic understanding of WD, where local electric fields augment enthalpic transition-state barriers, and the local ionic environment facilitates field-driven ion transfer. Ultimately, these results present a new design space for designing ion-transfer catalytic processes, and ionic heterojunctions more broadly.

Nathan Stovall, T. [University of California, Berk↗

Advanced Electrical Materials and Components Being Developed

All aerospace systems require power management and distribution (PMAD) between the energy and power source and the loads. The PMAD subsystem can be broadly described as the conditioning and control of unregulated power from the energy source and its transmission to a power bus for distribution to the intended loads. All power and control circuits for PMAD require electrical components for switching, energy storage, voltage-to-current transformation, filtering, regulation, protection, and isolation. Advanced electrical materials and component development technology is a key technology to increasing the power density, efficiency, reliability, and operating temperature of the PMAD. The primary means to develop advanced electrical components is to develop new and/or significantly improved electronic materials for capacitors, magnetic components, and semiconductor switches and diodes. The next important step is to develop the processing techniques to fabricate electrical and electronic components that exceed the specifications of presently available state-of-the-art components. The NASA Glenn Research Center's advanced electrical materials and component development technology task is focused on the following three areas: 1) New and/or improved dielectric materials for the development of power capacitors with increased capacitance volumetric efficiency, energy density, and operating temperature; 2) New and/or improved high-frequency, high-temperature soft magnetic materials for the development of transformers and inductors with increased power density, energy density, electrical efficiency, and operating temperature; 3) Packaged high-temperature, high-power density, high-voltage, and low-loss SiC diodes and switches.

Schwarze, Gene E.↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Transverse Magnetic Field Propellant Isolator

An alternative high voltage isolator for electric propulsion and ground-based ion source applications has been designed and tested. This design employs a transverse magnetic field that increases the breakdown voltage. The design can greatly enhance the operating range of laboratory isolators used for high voltage applications.

Foster, John E.↗

Characterization and Damping Control of Mechanical Connections to Improve Performance of Horn Stripline

Magnetic focusing horns are critical components for creating a stable beam of neutrinos for neutrino facilities, such as the Long Baseline Neutrino Facility (LBNF) and the Neutrinos and Main Injector (NuMI) beam lines at Fermilab. The pulsed magnetic horns are powered by high current electricity through long striplines, which must survive in a harsh radiation environment for the operational life of the component. Each stripline assembly consists of four layers of Al 6101-T6. As an electro-mechanical system, the stripline layers are bolted together with ceramic isolators for electrical insulation and to facilitate passive cooling and mechanical stability. The striplines experience vibrational force in addition to clamping force, repetitive thermal and electro-magnetic loading. The holes of stripline plates for ceramic joints represent one of the weak links for potential failure. Damping can be achieved by adding damp material to the joint. By characterizing behavior of the joint and optimizing their damping properties through FEA and EMA, the stripline performance and longevity can be improved. Appropriate damp materials are the key.

Liu, Zunping [Fermilab]↗