Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Power System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

Impacts of Solar Land Availability on the Evolution of the U.S. Power System

Long-term planning scenarios of the United States electricity system have not identified solar resource availability to be a limiting factor in how much solar capacity might be deployed. However, there are some smaller regions where siting challenges indicate solar deployment could be limited by solar resource availability. In this work, we use geospatial modeling tools to develop a restrictive siting scenario that significantly reduces the amount and location of utility-scale solar resources. We use that restrictive siting regime, along with other previously defined siting scenarios, to examine how solar resource availability impacts the buildout of the electricity system using business-as-usual and decarbonization futures in a national-scale capacity expansion model. The restrictive siting scenario uses observed siting pressures to exclude many types of land on which development is allowed today and results in a greater than 90% reduction in solar resource potential-to approximately 3000 GW. Even with this drastic reduction, utility-scale solar capacity grows by more than 3 times through 2050 in the business-as-usual scenarios and by more than 6 times in the decarbonization scenarios, though less solar is deployed in scenarios with lower available solar resource. We quantify how system costs and generation mixes change as solar resource availability changes.

14 SOLAR ENERGY↗

Toward integrating high-fidelity CFD approaches in the thermal-hydraulic analysis of turbulent dry cask systems

Nuclear power plants have been supplying resilient and reliable electricity for decades, contributing to energy independence of the U.S.. However, nuclear waste management remains one of the most significant challenges in the industry. The safety of dry cask storage systems relies heavily on their thermal-hydraulic performance. Computational Fluid Dynamics (CFD) simulations are often used to demonstrate this performance and ensure that the system design meets safety standards. This study presents reduced numerical models for various types of dry cask systems. These numerical models can produce efficient and fast results based on the employed modeling strategies. Additionally, the study uses a novel approach to high-fidelity simulations to evaluate modeling assumptions in dry cask modeling. Large Eddy Simulations (LES) are used for this purpose, particularly in regions where fluid velocity is relatively high and the turbulence characteristics become important. Furthermore, the results of these high-fidelity simulations will enhance the interpretation of outcomes produced from a lower-fidelity CFD model.

CFD↗

Connecting Minds: AI Use Cases to Bridge Power Systems and Large Language Models for Practical Applications

Recent advances in artificial intelligence (AI) and development of large language models (LLMs) present the opportunity to develop a new generation of power systems applications. In contrast with early power system AI applications based on structured numerical data, LLMs offer unique capabilities to perform logical reasoning using text documents, unstructured data, and application programming interface (API) calls to computational software. This paper seeks to bridge the knowledge gap between power systems engineers and LLM developers through a crosscutting explanation of use cases, characteristics, requirements, practical considerations from the perspectives of both LLM capabilities and industry needs. Specific focus is given to applications that can be realistically deployed by electric utilities. After introducing the architecture of LLMs and unique challenges of the power systems domain, this paper proposes twenty representative LLM applications grouped into categories of 1) power system operations, 2) asset management, 3) system planning and analytics, and 4) energy management and protection systems. Five use cases are presented within each category with descriptions of the motivation, objectives, approaches, example inputs / outputs, and benefits of each use case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CharIN Megawatt Charging System: 4 th Event Summary Report

Medium- and heavy-duty electric vehicles require higher charging power levels than are supported by present light-duty EV charging standards. The Charging Interface Initiative (CharIN) Megawatt Charging System (MCS) Task Force is undertaking efforts to develop a new high-power charging standard for medium- and heavy-duty vehicle electrification. The fourth MCS evaluation event at NREL focused on thermal and mechanical performance evaluations of high-power MCS electric vehicle charging connectors and inlets from several different manufacturers, at current levels up to 3000A. Additionally, the event evaluated the performance of a reference inlet design, which will provide a baseline level of thermal performance for use in future evaluation and certification efforts of MCS connectors.

33 ADVANCED PROPULSION SYSTEMS↗

A review of energy storage for power system resilience: Functions, metrics, and applications

Aging infrastructure, increasing operational complexity, and surging electricity demand from artificial intelligence and electrification are straining the grid and heightening the risks of disruptions, making resilience a critical priority. Energy storage is increasingly deployed to provide critical power supply, fast grid support, and rapid restoration. However, current practice lacks consistent metrics and systematic methodologies to rigorously quantify the resilience benefits of storage. This paper provides a comprehensive review of energy storage in resilience enhancement, focusing on functional roles, quantification metrics, and integration strategies. A structured resilience metrics library is compiled and categorized to encompass both technical and economic performance aspects. Existing methodologies for resilience-oriented storage planning and operations are critically examined. Key technical and practical challenges are identified, and future research directions are outlined to strengthen storage contributions to grid resilience.

Benefit quantification↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

High Performance Computing Peak Shaving for Microreactor Operation

There are multiple nuclear microreactors currently under development that are designed to provide autonomous power for as many as ten or more years without refueling and are designed to power high performance computing (HPC) datacenters. But the load-follow speeds for a nuclear microreactor will be much slower than grid power and slower than the power variance typical of a HPC system. HPC datacenters experience peak power load variance driven by several factors ranging from the operation of cooling systems to remove heat from the servers to supporting a wide range of user application workflows and architectures each with different power signatures. One mechanism to support the limited load-follow of a microreactor is peak shaving where an energy storage mechanism is used to shed peak load and reduce significant power variance. This work explores peak electrical load shaving using uninterruptible power supply (UPS) systems designed for HPC support in the context of peak shaving when operating using a nuclear microreactor with a load-follow limited to 10% of load per minute. Using a self contained HPC datacenter complete with stand-alone cooling system and provisioned with an x86 cluster, an ARM cluster, and a graphics processing unit (GPU) cluster, peak shaving for microreactor operation using the UPS battery backup is explored while running two classes of typical HPC user applications. HPC architecture suitability for microreactor operation under this type of peak shaving is examined.

97 MATHEMATICS AND COMPUTING↗

How Fisheries Biologists Can Facilitate the Clean Energy Transition

Abstract Fisheries and aquatic biologists play a critical role in creating environmentally protective hydropower flow requirements that govern flow timing, frequency, magnitude, and rate of change. Hydropower's role in the U.S. electrical grid is expected to evolve in response to increased wind and solar generation as hydropower will be called upon to quickly ramp up and down in response to changes in wind and solar generation. For this reason, hydropower is expected to have increased value as fossil generation is phased out, even as rapid flow fluctuations linked with hydropower flexibility may strand fish, alter habitat, and create unsafe recreational conditions. We face a new challenge in facilitating the renewable energy transition—designing environmental flow requirements that protect against the impacts of flow fluctuations while allowing adequate hydropower flexibility to support a stable grid. In this paper, we discuss hydropower environmental flow requirements, operational flexibility, and electrical grid stability, their potential interactions, and opportunities to align environmental and power system needs to support healthy ecosystems, multiple water uses, and decarbonization of the electric grid.

13 HYDRO ENERGY↗

Transmission Operator Workflows for Real-Time Reliability Studies: A Review of Control Room Practices and Naturalistic Decision Making

This report provides an overview of real-time reliability study tools and their use by power system operators in the control room environment. After introducing some of the nuances of the control room environment and the differences in perspectives between power system engineers and operators, the roles and responsibilities of key entities involved in RTCA workflows are introduced. These are specifically the transmission system operator (TOP) and reliability coordinator (RC), which are required to run tools such as real-time contingency analysis (RTCA) as part of a real-time reliability assessment every 30 minutes, as dictated by a series of standards issued by the North American Electric Reliability Corporation (NERC). The process by which power systems operators operate the grid is discussed in terms of naturalistic decision making (NDM) and the recognition-primed decision-making (RPD) model. This cognitive model describe how experts working in high-risk, high-stress environments make safety-critical decisions under uncertainty and time pressure. For power system operators, the mental simulations involved in the traditional RPD model are supplemented by physics-based simulations using numerical tools, such as RTCA, to improve situational awareness and effectiveness of control actions. Next, a generic workflow is introduced to describe operator decision making for running RTCA tools and responding to system violations on a pre-contingent basis. The types of analysis performed and control actions chosen by power system operators are described in detail. The overall high-level workflow is then expanded in subsequent sections, with special attention given to high-voltage violations, low-voltage violations, and thermal overloads. Each type of violation is described in detail, with explanations of common causes, impacts on equipment and customers, and mitigation strategies. An additional workflow diagram is provided for each type of violation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Load Forecasting Considering EV Charging Loads with Prediction Interval Evaluation

Short-term load forecasting plays a critical role in power system planning and operation. Along with the electrification of various loads, electricity demands are becoming increasingly hard to predict. Notably, the recent rise in electric vehicles (EVs) has further contributed to this unpredictability. To address this issue, this paper proposes a probabilistic load forecasting strategy utilizing Gaussian process regression, structured in a day-ahead manner. While many works focus on deterministic prediction, probabilistic forecasting offers additional insights into variability and uncertainty, enabling more flexible and reliable operation for power systems. To enhance the accuracy of the load forecasting model, the inputs include features related to EV charging habits as well as commonly used weather information. The load forecasting results are evaluated using various metrics, including conventional ones that assess the accuracy of point forecasts, as well as additional metrics that test the reliability of prediction intervals. The proposed load forecasting method is finally tested on real residential power consumption data and EV charging data sampled from real-world sources. The results prove that the new features can greatly improve the performance of the load forecasting method.

electrical vehicle↗

An innovative SR-WEC for a market-disruptive LCOE

The objective of DE-EE0008630: An innovative SR-WEC for a market-disruptive LCOE was to develop and test a scaled prototype of the Surface-Riding Wave Energy Converter that can result in a market-disruptive Levelized Cost of Energy by a combination of an extended operating window, substantially lowered cost and amplified average power output by simple optimum control. Initially conceptualized as a floating linear electrical generator (LEG), the SR-WEC evolved into an intermediate-scale version where multiple LEGs were mounted on a floating cylindrical body, driven by the need to enhance scalability and improve power performance.

16 TIDAL AND WAVE POWER↗

Graph-Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical Power Networks

With the increasing complexity and data availability in modern power systems, learning-based approaches to AC Optimal Power Flow (AC OPF) have garnered significant attention. In particular, the structure of smart grids lends itself naturally to graph-based representations, where Graph Neural Networks (GNNs) can capture spatial and relational dependencies. This paper investigates attention-based GNN architectures tailored to heterogeneous graph representations of electric grids. We evaluate two major paradigms: relational attention, which distinguishes between edge types during message passing, and meta-path attention, which captures high-level semantics through multi-hop, typed paths. Using a large corpus of public AC OPF scenarios, we benchmark representative models of each type of attention. Our results demonstrate the benefits of heterogeneous attention-based models in accurately capturing grid dynamics; heterogeneous attention models achieve superior performance in both standard and perturbed settings. The findings highlight the importance of semantic-aware architectures for improving prediction robustness and interpretability in power system applications.

Trigui, Ali [Qubit Engineering Inc.]↗

Power Systems Resilience

As communities take steps toward identifying and achieving their clean energy goals, the topic of resilience will likely emerge. This presentation aims to help inform and empower communities as they explore how their clean energy projects can address evolving power systems reliability and resilience due to climate change and other factors. The training provides a basic introduction to power systems and the resilience challenges this traditional infrastructure faces, as well as strategies for enhancing this important quality of electric service.

communities↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗