Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Phase 1 of the near term hybrid passenger vehicle development program

In order to meet project requirements and be competitive in the 1985 market, the proposed six-passenger vehicle incorporates a high power type Ni-Zn battery, which by making electric-only traction possible, permits the achievement of an optimized control strategy based on electric-only traction to a set battery depth of discharge, followed by hybrid operation with thermal primary energy. This results in a highly efficient hybrid propulsion subsystem. Technical solutions are available to contain energy waste by reducing vehicle weight, rolling resistance, and drag coefficient. Reproaching new 1985 full size vehicles of the conventional type with hybrids of the proposed type would result in a U.S. average gasoline saving per vehicle of 1,261 liters/year and an average energy saving per vehicle of 27,133 MJ/year.

Montalenti, P.↗

Large wind turbines: A utility option for the generation of electricity

The wind resource is such that wind energy generation has the potential to save 6-7 quads of energy nationally. Thus, the Federal Government is sponsoring and encouraging the development of cost effective and reliable wind turbines. One element of the Federal Wind Energy Programs, Large Horizontal Axis Wind Turbine Development, is managed by the NASA Lewis Research Center for the Department of Energy. There are several ongoing wind system development projects oriented primarily toward utility application within this program element. In addition, a comprehensive technology program supporting the wind turbine development projects is being conducted. An overview is presented of the NASA activities with emphasis on application of large wind turbines for generation of electricity by utility systems.

Robbins, W. H.↗

Preliminary Study of Advanced Turboprops for Low Energy Consumption

The fuel savings potential of advanced turboprops (operational about 1985) was calculated and compared with that of an advanced turbofan for use in an advanced subsonic transport. At the design point, altitude 10.67 km and Mach 0.80, turbine-inlet temperature was fixed at 1590 K while overall pressure ratio was varied from 25 to 50. The regenerative turboprop had a pressure ratio of only 10 and an 85 percent effective rotary heat exchanger. Variable camber propellers were used with an efficiency of 85 percent. The study indicated a fuel savings of 33 percent, a takeoff gross weight reduction of 15 percent, and a direct operating cost reduction of 18 percent was possible when turboprops were used instead of the reference turbofan at a range of 10 200 km. These reductions were 28, 11, and 14 percent, respectively, at a range of 5500 km. Increasing overall pressure ratio from 25 to 50 saved little fuel and slightly increased takeoff gross weight.

Kraft, G. A.↗

The Energy Systems Optimization Computer Program /ESOP/ developed for Modular Integrated Utility Systems /MIUS/ analysis

A significant energy and cost savings can be obtained by integrating various utility services (space heating and cooling, electrical power generation, solid waste disposal, potable water, and waste water treatment) into a single unit which provides buildings or groups of buildings with these services. This paper presents a description of a computer program, called the Energy Systems Optimization Program (ESOP). This program predicts the loads, energy requirements, equipment sizes, and life-cycle costs of alternative methods of meeting these utility requirements. The program has been used extensively for performing energy analyses of Modular Integrated Utility Systems (MIUS).

Ferden, S. L.↗

Identifying and analyzing methods for reducing the energy consumption of helicopters

The results are presented of a study to identify those helicopter technology areas which would result in the largest energy (or fuel) savings when applied to large tandem (100 passenger) civil helicopters in the 1985 time frame. Baseline aircraft using 1975 technology in the areas of powerplant, rotor efficiency, parasite drag and structure were sized to a very short haul mission of 100 N.M. and a short haul mission of 200 N.M. A systematic parametric analysis was then conducted to assess the impact of technology improvements. Projections of the technology levels that could be obtained in the 1985 time frame were made and the resources estimated to achieve them. Based on these data, the highest payoff (lowest energy) helicopter technologies are identified.

Davis, S. J.↗

The Ames Power Monitoring System

The Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also provides power engineers and electricians with the information they need to plan modifications in advance and perform day-to-day maintenance of the ARC electric-power distribution system.

Osetinsky, Leonid↗

One-year assessment of a solar space/water heater--Clinton, Mississippi

Unit called "System 4" integrated into space-heating and hot-water systems of dormitory satisfied 32 percent of building heat load. System 4 includes flat-plate air collectors, circulation blowers, rock storage bed with heat exchanger, two hot water tanks, and auxiliary heaters. Report describes performance of system and subsystems, operating-energy requirements and savings, and performance parameters.

Source record↗

Economic evaluation of a solar hot-water system--Palm Beach County, Florida

Report projects solar-energy costs and savings for residential hot-water system over 20 year period. Evaluation uses technical and economic models with inputs based on working characteristics of installed system. Primary analysis permits calculation of economic viability for four other U.S. sites.

Source record↗

Separating Silicon From Si/NaF Mixtures

New method of extracting silicon from mixture produced when silicon tetrafluoride is reduced by sodium takes advantage of lower melting point of NaF. Method is effective at temperatures up to 400 degrees C below melting point of Si. Results in energy and economic savings: simpler and smaller furnaces, less volatization loss, and high percentage of separation.

Sanjurjo, A.↗

Integration of energy management concepts into the flight deck

The rapid rise of fuel costs has become a major concern of the commercial aviation industry, and it has become mandatory to seek means by which to conserve fuel. A research program was initiated in 1979 to investigate the integration of fuel-conservative energy/flight management computations and information into today's and tomorrow's flight deck. One completed effort within this program has been the development and flight testing of a fuel-efficient, time-based metering descent algorithm in a research cockpit environment. Research flights have demonstrated that time guidance and control in the cockpit was acceptable to both pilots and ATC controllers. Proper descent planning and energy management can save fuel for the individual aircraft as well as the fleet by helping to maintain a regularized flow into the terminal area.

Morello, S. A.↗

Improving the efficiency of smaller transport aircraft

Considered apart from its propulsive system the high altitude airplane itself adapted to higher flight altitudes than those in current use. Scaling on the assumption of constant aircraft density indicates that this conclusion applies most importantly to smaller transport aircraft. Climb to 60,000 ft could save time and energy for trips as short as 500 miles. A discussion of the effect of winglets on aircraft efficiency is presented. A 10% reduction of induced drag below that of a comparable elliptic wing can be achieved either by horizontal or vertical wing tip extensions.

Jones, R. T.↗

Air Conditioner/Dehumidifier

An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

Source record↗

Development and Progress in Enabling the Photocatalyst Ti02 Visible-Light-Active

Photocatalytic oxidation (PCO) of organic contaminants is a promising air and water quality management approach which offers energy and cost savings compared to thermal catalytic oxidation (TCO). The most widely used photocatalyst, anatase TiO2, has a wide band gap (3.2 eV) and is activated by UV photons. Since solar radiation consists of less than 4% UV, but contains 45% visible light, catalysts capable of utilizing these visible photons need to be developed to make peo approaches more efficient, economical, and safe. Researchers have attempted various approaches to enable TiO2 to be visible-light-active with varied degrees of success'. Strategies attempted thus far fall into three categories based on their electrochemical' mechanisms: 1) narrowing the band gap of TiO2 by implantation of transition metal elements or nonmetal elements such as N, S, and C, 2) modifying electron-transfer processes during PCO by adsorbing sensitizing dyes, and 3) employing light-induced interfacial electron transfer in the heteronanojunction systems consisting of narrow band gap semiconductors represented by metal sulfides and TiO2. There are diverse technical approaches to implement each of these strategies. This paper presents a review of these approaches and results of the photocatalytic activity and photonic efficiency of the end .products under visible light. Although resulting visible-light-active (VLA) photocatalysts show promise, there is often no comparison with unmodified TiO2 under UV. In a limited number of studies where such comparison was provided, the UV-induced catalytic activity of bare TiO2 is much greater than the visible-light-induced catalytic activity of the VLA catalyst. Furthermore, VLA-catalysts have much lower quantum efficiency compared to the approx.50% quantum efficiency of UV-catalysts. This stresses the need for continuing research in this area.

Levine, Lanfang H.↗

The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-Rotors

During the course of the Kennedy Space Center Summer Internship, two main experiments were performed: The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-copters. The objectives of the Vacuum-Compacted Regolith Gripping Mechanism, often abbreviated as the Granular Gripper, are to exhibit Space Technology, such as a soft robotic hand, lift different apparatuses used to excavate regolith, and conserve energy while executing its intended task. The project is being conducted to test how much weight the Granular Gripper can hold. With the use of an Animatronic Robotic Hand, Arduino Uno, and other components, the system was calibrated before actually conducting the intended weight test. The maximum weight each finger could hold with the servos running, in the order of pinky, ring, middle, and index fingers, are as follows: 1.340N, 1.456 N, 0.9579 N, and 1.358 N. Using the small vacuum pump system, the maximum weight each finger could hold, in the same order, was: 4.076 N, 6.159 N, 5.454 N, and 4.052 N. The maximum torques on each of the fingers when the servos were running, in the same respective order, was: 0.0777 Nm, 0.0533 Nm, 0.0648 Nm, and 0.0532 Nm. The maximum torques on the individual fingers, when the small vacuum pump was in effect, in the same order as above, was: 0.2318 Nm, 0.3032 Nm, 0.2741 Nm, and 0.1618 Nm. In testing all the fingers with the servos running, the total weight was 5.112 N and the maximum torque on the all the fingers was 0.2515 Nm. However, when the small vacuum pump system was used, the total weight was 19.741 N and the maximum torque on the all the fingers was 0.9713 Nm. The conclusion that was drawn stated that using the small vacuum pump system proved nearly 4 times more effective when testing how much weigh the hand could hold. The resistance provided by the compacted sand in the glove allowed more weight to be held by the hand and glove. Also, when the servos turned off and the hand still retaining its position, energy is being saved because the vacuum created the same resistance the running servos did without using power. The Unmanned Flights via Quad-rotors are built because multi-rotor dynamics are an important starting point and fair analog for space craft control systems and they make good terrestrial development platforms for various aspects of control for space crafts. The project is being conducted to see what the thrust response is going to be when a pulse width modulation command is sent to the control system since the quad-rotors are PWM controlled. A simulation environment in constructed so that one can quickly iterate and test different designs such as control systems, PID control vs. LDR control, and state estimation. Using two DIY Quad Kits, APM 2.6, testing apparatus (called a data acquisition system) to test the quad-rotors, and a simulation program such as Simulink, two quad-rotors are built and controlled via a simulation program, which is designed to be as realistic as possible and not idealistic. Due to the quad-rotors not being completely built nor ready for testing, there are no results or conclusions to report.

Granular Gripper↗

Capacity and cutoff rate of (M+1)-ary decision rules for noisy M-ary optical PPM channel

The channel capacity C and the cutoff rate R sub o of two (M + 1)-ary decision rules for noisy M slots/symbol optical pulse position modulation (PPM) with ideal photon counting are computed and compared. Also the values of the optimum thresholds needed to minimize the signal requirements are given. With a minor increase in hardware complexity, the symbol by symbol threshold decision rule is shown to be superior to the slot by slot threshold detection and decision rule in two aspects: first, it saves more than 0.5 dB in signal energy for the very noisy cases of more than one noise photon per slot (for low noise cases it also saves signal energy, but a negligibly small amount). Second, it is more robust to variations in the noise level.

Lee, P. J.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 3: Industrial processes

Cogenerating electric power and process heat in single energy conversion systems rather than separately in utility plants and in process boilers is examined in terms of cost savings. The use of various advanced energy conversion systems are examined and compared with each other and with current technology systems for their savings in fuel energy, costs, and emissions in individual plants and on a national level. About fifty industrial processes from the target energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. An attempt was made to use consistent assumptions and a consistent set of ground rules specified by NASA for determining performance and cost. Data and narrative descriptions of the industrial processes are given.

Palmer, W. B.↗

Conservation and the industry sector

The following six highly energy intensive industries were studied as targets of energy conservation opportunity: food and kindred products, paper and allied products, chemicals and allied products, petroleum and coal products, stone, glass and clay products, and primary manufacturing. After studying conservation actions within each industry the actions were grouped under three broad categories: increased combustion efficiency, process improvement, and good housekeeping. Some of the results were: (1) approximately 2.18 quads could be saved in 1980 and 2.57 quads in 1985 by installing cogenerative facilities in 50% of the industries, (2) regenerative air-preheaters could result in a 10-15% increase in furnace efficiency representing a 15-25% fuel savings (2.3 to 3.9 quads in 1980 and 2.7 to 4.5 quads in 1985), (3) several major industries have potential for energy savings by recycling-aluminum (0.2 quads), steel (1 quad), glass (0.006 quads), paper and cement (0.08 quads).

Source record↗