Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

South Africa’s Appliance Energy Efficiency Standards and Labeling Program

Electricity consumption in South Africa comes with a hefty environmental cost to the society. For every kilowatt-hour (kWh) produced, 1 kilogram (kg) of carbon dioxide (CO 2 ) is emitted, 1.4 liters of water are used, and 0.37 grams of particulate emissions are released in the atmosphere. These environmental implications result from the large share of electricity produced from coal (91 percent in 2015). While planned new capacity will ramp up renewable energy, the integrated resource plan for the country still projects the share of col to be 64 percent in 2030. Energy savings provide environmental benefits as well as economic benefits. Energy efficiency standards and labeling (S&L) programs are a policy measure proven to save energy. Such programs have been implemented in many countries to remove inefficient technologies and transform markets to more efficient technologies. In this study, we describe the methodology, assumptions and results of a stock turnover modeling tool that estimates the energy savings achievable by South Africa’s S&L program in the residential sector. We show that if regulations are passed in 2020 and effective in 2021 for 10 major end-use adopting international standards best practices, 6 terawatt-hours (TWh) will be saved in 2030 and 9.5 TWh will be saved in 2040, representing a CO 2 mitigation of 3.7 megatonnes (Mt) in 2030 and 5.8 Mt in 2040, which will contribute to the South African government’s international engagement in fighting against climate change through its National Determined Contribution (NDC). Additional environmental benefits include saving of 6.5 billion liters of water in 2030, representing approximately 100 liters per capita in 2030. Air quality will also improve, as 4 kilotons (kt) of particulate emissions will be avoided, as well as 4.3 Mt of sulfur oxides (SOx) and 23 kt of nitrogen oxides (NOx) in 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal planning of the joint placement of photovoltaic panels and green roofs under climate change uncertainty

Photovoltaic (PV) panels directly convert sunlight into electricity; but, sunlight also heats the panels, negatively impacting their efficiency. Green roofs are vegetative layers grown on rooftops, mainly to provide added insulation on the roof to save energy. Green roofs also cool near-surface air temperature. Hence, the joint installation of PV panels and green roofs may potentially lead to higher efficiency of PV panels in certain climates. We develop a two-stage stochastic programming model to optimally place PV panels and green roofs under climate change uncertainty to maximize the overall profit from energy generated and saved. We calibrate the model using the literature, industry reports, and the data from different, at times conflicting, climate projections. We then conduct a case study for a mid-size city in the U.S., perform extensive sensitivity and robustness analyses and provide insights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

The current state of the industrial energy assessment and its impacts on the manufacturing industry

Energy-intensive manufacturing is the greatest contributor to the U.S. industrial energy consumption today. Globally, manufacturing facilities are being directed to reduce their energy consumption to prepare for a sustainable future. Industrial energy assessment plays a crucial role in helping facilities meet their energy efficiency goals by encouraging the implementation of cost-effective, energy-saving recommendations to the existing equipment and processes. Across the world, programs such as the U.S. Department of Energy (DOE) sponsored Industrial Assessment Centers (IACs) (operational across several states in the U.S. for over four decades), are transforming the future of industrial energy consumption by offering free industrial energy assessments to qualifying facilities. In this review paper, the industrial energy assessment approach and practices are comprehensively reviewed with focus on popular recommendations, procedures, and the current practices of the industrial energy assessment program. Specifically, opportunities for improvement in the most energy-intensive manufacturing processes are examined, concentrating on the energy savings and other non-energy benefits of each of these measures, such as cost savings and emissions reduction. Furthermore, this paper also reviews how these energy-saving opportunities are procedurally evaluated and how factors, such as level and cost of assessments, and assessment metrics, are currently defining industrial energy assessment. In final considerations, existing research on energy management, decarbonization through electrification, and renewable energy in industry is reviewed and discussed, and how these advancements will shape the future of industrial energy assessment is addressed through forward-looking lenses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ESPC ESA Training Series: Photovoltaic (PV) Project Considerations

This training covers technical, economic and other photovoltaic (PV) project considerations. Technical topics include cost-effectiveness, resilience, cybersecurity, and electrical considerations. In addition, other topics, such as compatibility with agency mission, site plans, coordination with the serving utility, the National Environmental Policy Act, and agency approval requirements. Considerations specific to third-party owned/third-party financed PV projects are also covered, as well as available resources and templates for project development. The training also includes a recap of the first session in the Energy Savings Performance Contracts Energy Sales Agreements (ESPC ESA) Webinar Series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simplified Building Modeling Approach for Identifying Whole Building Retrofits

Building Energy Modeling (BEM) is an effective strategy for optimizing new and retrofit building design, evaluating its energy savings potential and rating its energy performance. However, because of the complexity and expense of modeling, only a small percentage of buildings are simulated. Over 80% of buildings are <25,000 ft2, and the cost associated with BEM can be a big deterrent for reaching this subsector, which usually ends up complying with energy codes and qualifying for incentives using prescriptive measures or generalized design guides. Similarly, efficiency considerations for small building retrofits are often identified through deemed measures or Technical Reference Manuals, which though a scalable and convenient approach, can limit innovation in design and optimization of measures. Simplification of the modeling process, where appropriate, can lead to increased energy savings and more informed decision making. This paper will discuss the development of a ruleset for a simplified approach based on the Performance Rating Method (PRM) contained in ASHRAE Standard 90.1. The approach aims to simplify and lower the cost of the energy modeling process in a controlled and documented manner. An anticipated outcome is an increased use of BEM and its effectiveness in the design, retrofit and operation of commercial buildings. In addition, simplification of the modeling process will result in fewer errors from misinterpretations of both program requirements and program intent in simulation software. The paper will discuss the need and advantages of a simplified modeling approach for whole building retrofits and the technical process for achieving the same.

Goel, Supriya↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2024

Energy Savings Performance Contracts (ESPCs) are a contractual mechanism that allow a federal agency to procure energy savings and facility improvements without upfront capital costs to reduce costs and enhance mission resiliency. ESPCs are covered under FAR Part 23.2, and 42 USC § 8287. Section 8287(a)(2)(A) of Title 42 of the U.S. Code requires that each energy savings performance contract (ESPC) undergo an annual energy audit, resulting in a separate audit report for every project. The objective of the present report is to compile and analyze all annual ESPC audit reports issued between October 1, 2023, and September 30, 2024, for projects awarded under Generations 1, 2, and 3 of DOE’s ESPC IDIQ contracts. During this period, 205 measurement and verification (M&V) reports were produced for 200 projects; the total number of reports exceeds the number of projects because some projects generated more than one report (for example, a few projects measure savings twice per year and produce two audit reports annually, each covering a different six-month period). By aggregating the results from these individual audits, the report determines the portfolio-wide realization rate of energy and cost savings for all active ESPC projects awarded under DOE’s IDIQ program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of the Evaluation of Building Energy Code Compliance in the United States

Building energy codes are essential tools for achieving energy efficiency in buildings. However, the full energy savings potential of these codes can only be realized if buildings are constructed in compliance with them. Therefore, evaluating building energy code compliance is crucial in bridging the gap between the energy efficiency requirements set by energy codes and the actualized energy savings achieved. An energy code compliance evaluation serves as a mechanism to assess construction practices, evaluate the effectiveness of code enforcement, identify gaps in compliance, and guide strategies for improvement through training and education. Conducting code compliance evaluation activities involves field studies that require careful design and significant resources. Historically, more emphasis has been placed on developing and adopting building energy codes, while efforts to evaluate compliance have been relatively limited and lacking consistent approaches. The passage of the 2009 American Recovery and Reinvestment Act (ARRA), which mandated that states create plans for achieving 90% compliance within eight years, stimulated the need for an energy code compliance evaluation. As a result, federal, state, and local governments, and utilities have invested in the development of methodologies and tools for code compliance evaluation studies. This paper reviews the code compliance evaluation studies conducted in the United States over the past three decades. It describes and compares the methodologies and metrics used to assess building energy code compliance, summarizes the general elements and steps involved in the evaluation process, and discusses common issues in these studies. Over time, code compliance evaluation methodologies have evolved from isolated development within individual states, regions, and utilities, to widely accepted protocols applicable across different states and local jurisdictions. There has been a transition in compliance metrics, shifting from historical compliance rates to energy-consumption-oriented approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S.-China Clean Energy Research Center Building Energy Efficiency (CERC-BEE) Open-Source Retrofit Targeting Tool (CRADA FP00007338 Final Report)

To increase the cost-saving energy and carbon dioxide (CO 2 ) emissions reductions in buildings and portfolios at the scale and speed necessary to limit climate change, researchers at LBNL and Johnson Controls (JCI) developed the Building Efficiency Targeting Tool for Energy Retrofits (BETTER). BETTER is a software tool that consists of three components: (1) the BETTER analytical engine source code (which was developed with intellectual property provided by JCI under CRADA FP00007338); (2) the BETTER web application, developed by LBNL and McQuillen Interactive Pty. Ltd; and (3) the BETTER application programming interface (API), also developed by LBNL and McQuillen Interactive Pty. Ltd. BETTER enables building and portfolio owners, managers, and service providers worldwide to quickly, easily identify cost-saving energy efficiency retrofits in existing buildings and portfolios without expensive site visits or complex modeling. With minimal data input, the tool benchmarks a building’s electric and fossil energy usage against peers; quantifies energy, cost and greenhouse gas (GHG) emission reduction potentials at the building and portfolio levels; and recommends energy efficiency measures to decarbonize and electrify buildings and portfolios, targeting specific energy savings levels. No other tool so comprehensively analyzes buildings and portfolios with such ease. If fully implemented, it is estimated that BETTER could help reduce emissions equivalent to planting 1.3 billion trees globally by 2030. Moreover, an additional 50-75% of embodied GHG emissions could be avoided in each case where BETTER results in a building being retrofitted instead of demolished and replaced, providing substantial additional decarbonization benefits for the buildings sector. BETTER has garnered multiple awards and avid interest from investors. In 2020, it earned a R&D 100 Award for innovation and a LBNL Director’s Award for Technology Transfer. In 2021, BETTER was named an EarthX E-Capital Summit Climate Tech Prize semi-finalist

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗