Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electrification Analysis: All Aboard America!

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, an electrification analysis for the Bustang motorcoach fleet operated by All Aboard America! Holdings Inc. (AAA). NREL installed logging devices and collected operational data on nine 40-foot Bustang motorcoaches operating on fixed routes from May 2022 through August 2022. The analysis determined that partial fleet electrification may be feasible with electrified motorcoach options currently on the market. While this fleet faces significant challenges to electrification given current market options due to demanding range requirements and relatively limited charging opportunities, vehicles operating on the shorter, lower-grade routes along the I-25 corridor show more immediately available electrification potential. Increases in available battery capacity and the availability of fast-charging locations along I-70 routes are likely critical for electrification of the full fleet.

AAA↗

Estimating Electrification Potential for Class 8 Regional-Haul Trucks

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline. As part of the North American Council for Freight Efficiency's (NACFE's) Run on Less Depot data workshop, NREL sought to understand how Tesla semi-trucks would perform in real-world regional haul applications. Analysis reveals that the modeled Tesla trucks, with an average efficiency of 1.78 kWh/mi, struggle to achieve full operational coverage using current battery and charging configurations assuming operations remain unchanged. However, in an extreme case where ubiquitous charging exists, 100% EV coverage is possible for the given drive cycles. These findings highlight the trade-off between battery size and charge rate in electrification potential and emphasize the necessity for advancements in charging infrastructure to enable electric trucks for regional haul operations.

ADVANCED PROPULSION SYSTEMS↗

Connecting ground-state properties of 6 Li to each other and to scattering data

We examine the relationship between the asymptotic normalization coefficient (ANC) of 6 Li and other low-energy observables in the α–deuteron system. Our analysis uses a set of calculations carried out within the ab initio no core shell model with continuum (NCSMC) using a variety of inter-nucleon interactions and basis sizes, and yielding 6 Li deuteron separation energies between 1.3 and 1.8 MeV (Hebborn et al 2022 Phys. Rev. Lett. 129 042503). These NCSMC calculations show that the square of the ANC is strongly correlated with the separation energy over this range. In this work, we investigate the origin of this correlation using the phenomenological R-matrix, a single-channel potential and a perturbative approach. We show that this correlation occurs because the depth of the α–deuteron central potential changes by only a small relative amount as the separation energy varies. We then investigate if the ANC can be accurately extracted from α–deuteron phase shifts in an ideal case in which low-energy data are available and there are no experimental errors. We find that both R-matrix and Coulomb-modified effective-range theory (CM-ERE) yield extracted ANCs close to, although not exactly equal to, the NCSMC value, provided the extrapolation is constrained by the known position of the bound-state pole and at least three terms are included in the fit function. The R-matrix approach converges faster than the CM-ERE as the number of parameters increases and is also more robust against the inclusion of low-energy and high-energy phase shift data. Finally, our study also shows that a naive quantification of uncertainties by comparing different truncations used in both theories is not accurate, and suggests the accuracy of ANCs extracted from phase shift data needs further investigation.

R-matrix↗

Detecting the undetected: Dealing with non-routine events using advanced M&V meter-based savings approaches

In a rapidly evolving energy industry, utilities are dealing with new challenges like integrating distributed energy resources and market saturation for advanced lighting retrofits. Demand-side management programs require new approaches to meet aggressive carbon reduction goals. Advanced measurement & verification (M&V) is an energy data analysis method using smart meter data in combination with analytics to quantify energy efficiency project savings. Advanced M&V shows great promise for supporting next generation commercial programs including retro commissioning, multi-measure retrofits, and behavior change programs. Advanced M&V captures real project impacts at the meter, but sometimes non-project events can also impact consumption (so-called “non-routine events” [NREs]). Accurately detecting and accounting for NREs is important for reducing uncertainty of savings estimates and helps manage investment risk for different stakeholders (e.g., utilities, building owners, ESCOs). Recent research has shown promise in establishing data-driven techniques to identify and adjust for NREs, but fundamental questions still remain, such as: how can you distinguish NREs from acceptable noise in energy consumption profiles? What is the frequency and magnitude of NREs? Can their detection and adjustment be automated and streamlined? This paper documents the state of the art in NRE quantification and analysis. The results of research to quantify the frequency, nature and direction of NREs, and methods and metrics for determining a trigger threshold for taking action on NREs are presented. The paper also documents the latest technical guidance on application of NRE detection and adjustment methods.

Fernandes, Samuel↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OEDI—Solar Grid Integration Data and Analytics Library

As a part of the Open Energy Data Initiative, this effort aims to develop and demonstrate novel distribution state estimation, control optimization, and transient analysis as well as provide access to data, data integration, and mapping information. More specifically, the focus of the effort will be on physics-based distribution system state estimation, hybrid (physics-based and machine learning) distribution optimal power flow, and event detection/analysis for solar integration and analytics. This work will enable reproducible, robust, replicable, and generalizable R&D in simulation and emulation of solar system integration. These test models and datasets will provide an integrated library for developing and testing power system operation technologies. To make the library user-friendly, this project will provide data curation tools such as data translators, mapping scripts and APIs, database schemas and metadata, interfaces and user dashboard, source code for the reference algorithms, description of the use-cases/scenarios, and comprehensive information on all the assumptions.

14 SOLAR ENERGY↗

Computed Tomography Scanning and Geophysical Measurements of the Clinton Formation in Ohio

Computed tomography and multi-sensor core logging of core material from twelve Ohio wells held by the Ohio Department of Natural Resources, Division of Geological Survey to make publicly available core information from the Early Silurian Clinton Formation in Eastern Ohio. Describes data available can be accessed from NETL’s Energy Data eXchange (EDX) online system, https://edx.netl.doe.gov/dataset/ct-and-geophysical-data-of-ohio-clinton-sands.

58 GEOSCIENCES↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Foundational Industry Energy Dataset: Unit-level Characterization and Derived Energy Estimates for Industrial Facilities in 2017

The Foundational Industry Energy Dataset (FIED) addresses several of the areas of growing disconnect between the demands of industrial energy analysis and the state of industrial energy data by providing unit-level characterization by facility. Each facility is identified by a unique registryID, based on the U.S. Environmental Protection Agency (EPA) Facility Registry Service, and includes its coordinates and other geographic identifiers. Energy-using units are characterized by design capacity, as well as their estimated energy use, greenhouse gas emissions, and physical throughput using 2017 data from the EPA's National Emissions Inventory and Greenhouse Gas Reporting Program. An overview of the derivation methods is provided in a separate technical report which will be linked after publication. The Python code used to compile the dataset is available in a GitHub repository. An updated 2020 version is under development.

Array↗

Electrification Analysis: Container Ports' Cargo Handling Equipment

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, the Electrification Analysis of Container Ports' Cargo Handling Equipment project. This project created a scalable solution to model energy demand per shipping container moved (kWh/TEU) for an all-electric cargo handling equipment fleet located at a maritime port. The model allows stakeholders to understand energy demand at each electric vehicle (EV) equipment level and is easily scalable to container demand and EV adoption rate projections.

ADVANCED PROPULSION SYSTEMS↗

Systems and methods for data analytics for virtual energy audits and value capture assessment of buildings

A system may provide virtual energy audits of one or more target buildings. The system may retrieve weather data and energy usage data specific to a given target building from a weather server and a utility server, respectively. The system may store predefined building characteristics corresponding to the given target building in local memory. Based on the weather data, energy usage data, and/or predefined building characteristics, the system may generate one or more building markers that characterize the energy usage and efficiency of the given target building. Building efficiency diagnostics and energy conservation prognostics may be generated based on the building markers and may be sent by the system to be displayed via a user interface of a client device. The energy conservation prognostics may include one or more energy conservation measure recommendations and corresponding predicted cost/energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dark Energy Survey Year 3 results: Cosmology from cosmic shear and robustness to data calibration

This work, together with its companion paper, Secco, Samuroff et al., presents the Dark Energy Survey Year 3 cosmic shear measurements and cosmological constraints based on an analysis of over 100 million source galaxies. With the data spanning 4143 deg 2 on the sky, divided into four redshift bins, we produce the highest significance measurement of cosmic shear to date, with a signal-to-noise of 40. We conduct a blind analysis in the context of the ΛCDM model and find a 3% constraint of the clustering amplitude, S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.759$^{+0.025}_{-0.023}$. A ΛCDM-Optimized analysis, which safely includes smaller scale information, yields a 2% precision measurement of S 8 = 0.772$^{+0.018}_{-0.017}$ that is consistent with the fiducial case. The two low-redshift measurements are statistically consistent with the Planck Cosmic Microwave Background result, however, both recovered S 8 values are lower than the high-redshift prediction by 2.3σ and 2.1σ (ρ-values of 0.02 and 0.05), respectively. The measurements are shown to be internally consistent across redshift bins, angular scales and correlation functions. The analysis is demonstrated to be robust to calibration systematics, with the S 8 posterior consistent when varying the choice of redshift calibration sample, the modeling of redshift uncertainty and methodology. Similarly, we find that the corrections included to account for the blending of galaxies shifts our best-fit S 8 by 0.5σ without incurring a substantial increase in uncertainty. We examine the limiting factors for the precision of the cosmological constraints and find observational systematics to be subdominant to the modeling of astrophysics. Specifically, we identify the uncertainties in modeling baryonic effects and intrinsic alignments as the limiting systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Artificial Intelligence for Enhancing Multiscale Analysis: Buildings Focus

This project aims to develop multi-scale building energy data, potentially improving the representation of the U.S. buildings sector in GCAM-USA, an U.S.-focused human-energy-Earth systems model. Existing building energy datasets are typically limited to national or regional levels, which constrains the ability of models to capture fine-scale human-energy-Earth systems interactions and reduces their relevance for decision-making on issues such as energy security, resilience, and energy planning. By leveraging AI and advanced data integration methods, this work fuses multiple existing datasets to enhance the physical and geographic representation of both residential and commercial building energy use. So far, progress includes processing residential building data, designing the data structure for commercial buildings, and testing AI approaches for integrating datasets and addressing spatial-temporal gaps. This effort can not only advances GCAM-USA’s capability in modeling the buildings sector but also supports broader DOE missions, such as developing digital testbeds, enhancing grid resilience analysis, and improving building–energy system modeling at decision-relevant scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗