Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Atmospheric Radiation Measurement (ARM) airborne field campaign data products between 2013 and 2018

Airborne measurements are pivotal for providing detailed, spatiotemporally resolved information about atmospheric parameters and aerosol and cloud properties, thereby enhancing our understanding of dynamic atmospheric processes. For 30 years, the US Department of Energy (DOE) Office of Science supported an instrumented Gulfstream 1 (G-1) aircraft for atmospheric field campaigns. Data from the final decade of G-1 operations were archived by the Atmospheric Radiation Measurement (ARM) Data Center and made publicly available at no cost to all registered users. To ensure a consistent data format and to improve the accessibility of the ARM airborne data, an integrated dataset was recently developed covering the final 6 years of G-1 operations (2013 to 2018, https://doi.org/10.5439/1999133; Mei and Gaustad, 2024). The integrated dataset includes data collected from 236 flights (766.4 h), which covered the Arctic, the US Southern Great Plains (SGP), the US West Coast, the eastern North Atlantic (ENA), the Amazon Basin in Brazil, and the Sierras de Córdoba range in Argentina. These comprehensive data streams provide much-needed insight into spatiotemporal variability in the thermodynamic quantities and aerosol and cloud properties for addressing essential science questions in Earth system process studies. This paper describes the DOE ARM merged G-1 datasets, including information on the acquisition, data collection challenges and future potentials, and quality control processes. It further illustrates the usage of this merged dataset to evaluate the Energy Exascale Earth System Model (E3SM) with the Earth System Model Aerosol–Cloud Diagnostics (ESMAC Diags) package.

54 ENVIRONMENTAL SCIENCES↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Adaptive Algebraic Derivative Estimation for Battery Electric Buses Energy Consumption Forecasting

The limited service life of onboard batteries for EVs is a challenge, underscoring the need for real-time battery usage prediction. This paper proposes an adaptive Algebraic Derivative Estimation (ADE) approach for forecasting the energy consumption of battery electric buses. By dynamically adjusting the sliding window length, the adaptive ADE retains the fixed-length ADE’s key advantage—namely, operating online without reliance on extensive historical datasets—while substantially bolstering forecast accuracy by actively trading estimation bias off estimation variance. Comparative experiments against both the conventional ADE with a fixed length and a representative machine learning algorithm, XGBoost, were conducted, with performance evaluated via root mean square error, mean absolute error, and the coefficient of determination. The results demonstrate that the proposed approach significantly outperforms baseline methods.

Cui, Tianyang [The University of Texas at Dallas]↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

ALESEP: A computer program for the analysis of airfoil leading edge separation bubbles

The ALESEP program for the analysis of the inviscid/viscous interaction which occurs due to the presence of a closed laminar transitional separation bubble on an airflow is presented. The ALESEP code provides a iterative solution of the boundary layer equations expressed in an inverse formulation coupled to a Cauchy integral representation of the inviscid flow. This interaction analysis is treated as a local perturbation to a known solution obtained from a global airfoil analysis. Part of the required input to the ALESEP code are the reference displacement thickness and tangential velocity distributions. Special windward differencing may be used in the reversed flow regions of the separation bubble to accurately account for the flow direction in the discretization of the streamwise convection of momentum. The ALESEP code contains a forced transition model based on a streamwise intermittency function and a natural transition model based on a solution of the integral form of the turbulent kinetic energy equation. Instructions for the input/output, and program usage are presented.

Davis, R. L.↗

Space station: Cost and benefits

Costs for developing, producing, operating, and supporting the initial space station, a 4 to 8 man space station, and a 4 to 24 man space station are estimated and compared. These costs include contractor hardware; space station assembly and logistics flight costs; and payload support elements. Transportation system options examined include orbiter modules; standard and extended duration STS fights; reusable spacebased perigee kick motor OTV; and upper stages. Space station service charges assessed include crew hours; energy requirements; payload support module storage; pressurized port usage; and OTV service facility. Graphs show costs for science missions, space processing research, small communication satellites; large GEO transportation; OVT launch costs; DOD payload costs, and user costs.

Source record↗

Energy Management of the Multi-Mission Space Exploration Vehicle Using a Goal-Oriented Control System

Safe human exploration in space missions requires careful management of limited resources such as breathable air and stored electrical energy. Daily activities for astronauts must be carefully planned with respect to such resources, and usage must be monitored as activities proceed to ensure that they can be completed while maintaining safe resource margins. Such planning and monitoring can be complex because they depend on models of resource usage, the activities being planned, and uncertainties. This paper describes a system - and the technology behind it - for energy management of the NASA-Johnson Space Center's Multi-Mission Space Exploration Vehicles (SEV), that provides, in an onboard advisory mode, situational awareness to astronauts and real-time guidance to mission operators. This new capability was evaluated during this year's Desert RATS (Research and Technology Studies) planetary exploration analog test in Arizona. This software aided ground operators and crew members in modifying the day s activities based on the real-time execution of the plan and on energy data received from the rovers.

Braman, Julia M. B.↗

Energy Management Operations for the InSight Solar-Powered Mission at Mars

This paper discusses how the change in launch date has changed the energy management challenges for InSight, and how the energy management approach for surface operations has been adapted to address those challenges. It also describes how energy balance and battery life are protected over the course of the InSight landed mission, in terms of a deliberate balance between autonomous on-board fault protection and ground commanding into reduced-load configurations that still make progress versus specific, prioritized mission success criteria. It describes the project’s unique statistical analysis and usage of Mars Exploration Rovers (MER) archived data on solar energy collection to develop and validate an explicit prelaunch margin policy versus energy reductions due to environment variability over multiple-sol sequences. And finally, the paper explains how this archived energy data has influenced the modification of the Phoenix-heritage autonomous fault protection, to guard against quickly-arising inclement power-generation conditions, such as rapid onset of a local dust storm or water ice cloud front.

Lisano II, MIchael E.↗

Near-term hybrid vehicle program, phase 1. Appendix A: Mission analysis and performance specification studies report

Results of a study leading to the preliminary design of a five passenger hybrid vehicle utilizing two energy sources (electricity and gasoline/diesel fuel) to minimize petroleum usage on a fleet basis are presented. The study methodology is described. Vehicle characterizations, the mission description, characterization, and impact on potential sales, and the rationale for the selection of the reference internal combustion engine vehicle are presented. Conclusions and recommendations of the mission analysis and performance specification report are included.

Source record↗

Near-term hybrid vehicle program, phase 1. Appendix D: Sensitivity analysis resport

Parametric analyses, using a hybrid vehicle synthesis and economics program (HYVELD) are described investigating the sensitivity of hybrid vehicle cost, fuel usage, utility, and marketability to changes in travel statistics, energy costs, vehicle lifetime and maintenance, owner use patterns, internal combustion engine (ICE) reference vehicle fuel economy, and drive-line component costs and type. The lowest initial cost of the hybrid vehicle would be $1200 to $1500 higher than that of the conventional vehicle. For nominal energy costs ($1.00/gal for gasoline and 4.2 cents/kWh for electricity), the ownership cost of the hybrid vehicle is projected to be 0.5 to 1.0 cents/mi less than the conventional ICE vehicle. To attain this ownership cost differential, the lifetime of the hybrid vehicle must be extended to 12 years and its maintenance cost reduced by 25 percent compared with the conventional vehicle. The ownership cost advantage of the hybrid vehicle increases rapidly as the price of fuel increases from $1 to $2/gal.

Source record↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moment-based adaptive time integration for thermal radiation transport

Here, in this paper we develop a framework for moment-based adaptive time integration of deterministic multifrequency thermal radiation transpot (TRT). We generalize our recent semi-implicit-explicit (IMEX) integration framework for gray TRT to multifrequency TRT, and also introduce a semi-implicit variation that facilitates higher-order integration of TRT, where each stage is implicit in all components except opacities. To appeal to the broad literature on adaptivity with Runge–Kutta methods, we derive new embedded methods for four asymptotic preserving IMEX Runge–Kutta schemes we have found to be robust in our previous work on TRT and radiation hydrodynamics. We then use a moment-based high-order-low-order representation of the transport equations. Due to the high dimensionality, memory is always a concern in simulating TRT. We form error estimates and adaptivity in time purely based on temperature and radiation energy, for a trivial overhead in computational cost and memory usage compared with the base second order integrators. We then test the adaptivity in time on the tophat and Larsen problem, demonstrating the ability of the adaptive algorithm to naturally vary the timestep across 4–5 orders of magnitude, ranging from the dynamical timescales of the streaming regime to the thick diffusion limit.

97 MATHEMATICS AND COMPUTING↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

36 MATERIALS SCIENCE↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

42 ENGINEERING↗

A simulation model for wind energy storage systems. Volume 2: Operation manual

A comprehensive computer program (SIMWEST) developed for the modeling of wind energy/storage systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel, and pneumatic) is described. Features of the program include: a precompiler which generates computer models (in FORTRAN) of complex wind source/storage/application systems, from user specifications using the respective library components; a program which provides the techno-economic system analysis with the respective I/O the integration of system dynamics, and the iteration for conveyance of variables; and capability to evaluate economic feasibility as well as general performance of wind energy systems. The SIMWEST operation manual is presented and the usage of the SIMWEST program and the design of the library components are described. A number of example simulations intended to familiarize the user with the program's operation is given along with a listing of each SIMWEST library subroutine.

Warren, A. W.↗

Exploring the influence of transition metals on f-element bonding

The United States aims to triple its nuclear energy production by 2050, which will result in increased uranium usage and spent nuclear fuel generation. This highlights the need for a comprehensive understanding of actinide coordination chemistry, which is crucial for the extraction, processing, purification, and fabrication of uranium-based fuels. Moreover, it is vital for the reprocessing or safe disposal of nuclear waste and effective remediation efforts. Achieving this successfully requires an in-depth understanding of f-electron behavior, as “the role of 5f electrons in bond formation remains a fundamental topic in actinide chemistry”. Introducing a second metal into the system can increase structural dimensionality and diversify structural architecture. Heterometallic systems can also alter material properties, such as magnetic and spectroscopic characteristics, luminescence, and actinide mobility. Additionally, secondary transition metals, even when present only in the second coordination sphere and not directly coordinated, can influence the electron density at the actinyl metal center. In this study, uranium heterometallic single crystals were synthesized by incorporating transition metals such as iron(III), iron(II), nickel(II), manganese(II), copper(I), and cobalt(II). The crystals were formed using 2,6-pyridine dicarboxylic acid and other structurally similar ligands with varying functional groups. The synthesized crystals were analyzed using an extensive array of analytical and computational characterization techniques, including single crystal X-ray diffraction, Raman and infrared spectroscopy, and density functional theory calculations.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Solar energy system performance evaluation: Seasonal report for IBM system 1A, Huntsville, Alabama

The operational and thermal performance of the solar energy system, Sims Prototype System 1A, is described. The system was designed by IBM to provide 50 to 60 percent of the space heating and domestic hot water preheating load to a 2,000 square foot floor space single family residence in the Huntsville area. The load design temperature inside the building was to be maintained at 70 degrees fahrenheit with auxiliary energy for heating supplied by an electric heat pump assisted by an electric resistance strip heater. In general the disappointing operation of this system is attributed to the manner in which it was used. The system was designed for residential application and used to satisfy the demands of an office environment. The differences were: (1) inside temperature was not maintained at 70 F as expected; and (2) hot water usage was much lower than expected. The conclusion is that the solar energy system must be designed for the type of application in which it is used. Misapplication usually will have an adverse affect on system performance.

Source record↗