Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Exploring First-Order Approximation of Energy Equivalence of Safety at Intersections: Preprint

Maintaining safety is the most critical issue for a transportation system. Other considerations, albeit of secondary importance to safety, include energy use and delay. Quantifying the economic and societal costs of traffic crashes is an important area of study, and covers financial, energy and human impact considerations. Consequences of crashes include losses associated with crash-induced congestion, costs due to equipment damage and loss, and human injury and death. This study establishes the GDP-weighted energy equivalence of safety - encompassing the energy consumption associated with crashes. It proposes a framework for this calculation by extracting an equivalency rate from national-level statistics on total energy consumption of the transportation sector. Combining this with estimates of total direct and indirect costs of all crashes permits an estimation of their total GDP-weighted energy equivalence. The framework is demonstrated with an example calculation for the U.S. highway system in 2010. The results imply the tremendous potential energy value of technologies that promise to reduce or eliminate crashes.

25 ENERGY STORAGE↗

Asymptotic Equivalence of Probability Measures and Stochastic Processes

Let P{sub n} and Q{sub n} be two probability measures representing two different probabilistic models of some system (e.g., an n-particle equilibrium system, a set of random graphs with n vertices, or a stochastic process evolving over a time n) and let M{sub n} be a random variable representing a “macrostate” or “global observable” of that system. We provide sufficient conditions, based on the Radon–Nikodym derivative of P{sub n} and Q{sub n}, for the set of typical values of M{sub n} obtained relative to P{sub n} to be the same as the set of typical values obtained relative to Q{sub n} in the limit n→∞. This extends to general probability measures and stochastic processes the well-known thermodynamic-limit equivalence of the microcanonical and canonical ensembles, related mathematically to the asymptotic equivalence of conditional and exponentially-tilted measures. In this more general sense, two probability measures that are asymptotically equivalent predict the same typical or macroscopic properties of the system they are meant to model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation on Mechanical Properties and Equivalent Model of Aluminum Honeycomb Sandwich Panels

In this study, positive-pressure, bending, and drum peel tests were carried out for aluminum honeycomb sandwich panels made of different materials and with different dimensions. The results of these tests not only precisely revealed the relationships between the mechanical properties of aluminum honeycomb sandwich panels and the material dimensions of the face and core layers, the layout mode of the core layer, and the connecting mode between the face layers and core layers, but also determined the reliable mechanical equivalent model. The test results indicate that when the specimen was subjected to the vertical load, the compression properties of aluminum honeycomb sandwich panels were mainly determined by its core layer, while the face layer mainly relieves the axial stress and restrains the deformation of the core layer. In the flexural test, the face layer is the main part subjected to the load, whereas the core layer shows supporting, stabilizing, and strengthening effects, slowing the deformation of the face layer; flexural-tensile properties can be somewhat affected by the layout type of the core layer. The equivalent plate model, honeycomb plate model, and sandwich panel model were screened based on the experimental results, indicating that the sandwich panel model provided a more accurate description. The sandwich panel model was further modified, ultimately resulting in a more effective equivalent model that can accurately reflect the mechanical properties of the aluminum honeycomb sandwich panels.

36 MATERIALS SCIENCE↗

Coronary risk equivalence of diabetes assessed by SPECT-MPI

Background: Several publications and guidelines designate diabetes mellitus (DM) as a coronary artery disease (CAD) risk equivalent. The aim of this investigation was to examine DM cardiac risk equivalence from the perspective of stress SPECT myocardial perfusion imaging (MPI). Methods and Results: We examined cardiovascular outcomes (cardiac death or nonfatal MI) of 17,499 patients referred for stress SPECT-MPI. Patients were stratified into four categories: non-DM without CAD, non-DM with CAD, DM without CAD, and DM with CAD, and normal or abnormal perfusion. Cardiac events occurred in 872 (5%), with event-free survival best among non-DM without CAD, worst in DM with CAD, and intermediate in DM without CAD, and non-DM with CAD. After multivariate adjustment, risk remained comparable between DM without CAD and non-DM with CAD [AHR 1.0 (95% CI 0.84–1.28), P =0.74]. Annualized event rates for normal subjects were 1.4% and 1.6% for non-DM with CAD and DM without CAD, respectively (P = 0.48) and 3.5% (P = 0.95) for both abnormal groups. After multivariate adjustment, outcomes were comparable within normal [AHR 1.4 (95% CI 0.98–1.96) P = 0.06] and abnormal [AHR 1.1 (95% CI 0.83–1.50) P = 0.49] MPI. Conclusions: Diabetic patients without CAD have comparable risk of cardiovascular events as non-diabetic patients with CAD after stratification by MPI results. These findings support diabetes as a CAD equivalent and suggest that MPI provides additional prognostic information in such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Equivalence between classical and quantum dynamics. Neutral kaons and electric circuits

An equivalence between the Schroedinger dynamics of a quantum system with a finite number of basis states and a classical dynamics is presented. The equivalence is an isomorphism that connects in univocal way both dynamical systems. We treat the particular case of neutral kaons and found a class of electric networks uniquely related to the kaon system finding the complete map between the matrix elements of the effective Hamiltonian of kaons and those elements of the classical dynamics of the networks. As a consequence, the relevant {epsilon} parameter that measures CP violation in the kaon system is completely determined in terms of network parameters. - Highlights: > We provide a formal equivalence between classical and quantum dynamics. > We make use of the decomplexification concept. > Neutral kaon systems can be represented by electric circuits. > CP symmetry violation can be taken into account by non-reciprocity. > Non-reciprocity is represented by gyrators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical investigation of equivalence ratio effects on Flex-Fuel mixing controlled combustion enabled by prechamber ignition

There is interest in adapting renewable and low-carbon intensity fuels to heavy-duty engines to help displace criteria and greenhouse gas emissions associated with diesel combustion. Low-carbon fuels have inherently low cetane numbers and thus pose a significant challenge when considering direct substitution in diesel combustion systems. Use of an actively fueled prechamber as an ignition source to initiate mixing-controlled combustion (PC-MCC) of low-cetane fuels is becoming an attractive combustion mode to alleviate the identified reactivity deficit. This work focuses on the utilization of an active prechamber to facilitate diesel-like combustion of bioethanol-gasoline fuel blends in a heavy-duty engine. Recent results in this emerging technology suggest that ignition quality is uniquely coupled to prechamber equivalence ratio. In this numerical study, the fundamental implications of prechamber equivalence ratio on the ignition performance of direct injected fuels ranging from E10 to E100 are investigated using CONVERGE. Parametric studies of the prechamber operating strategy were assessed at diesel-like conditions to characterize the performance trends relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and achieves diesel-like ignition qualities and combustion processes for all fuels considered under stoichiometric and rich prechamber conditions. To characterize the equivalence ratio trends observed, a novel inflow boundary modeling technique was utilized to prescribe turbulent jets in place of the prechamber where selective speciation of the jet composition was conducted to isolate the ignition contributions of radical and reacting species in lean, stoichiometric, and rich jets. The inflow boundary modeling suggests that excess fuel and combustion intermediates present in jets produced from stratified and fuel-rich prechamber operation promotes higher jet temperatures and as such are superior ignition sources. Relative to a lean prechamber jet, the peak temperature of a reacting jet from a rich prechamber was up to 600 K hotter at fixed distances from the orifice exit. Furthermore, radicals also demonstrated an influence on the ignition process, but the combustion mode was identified to be thermally dominant.

33 ADVANCED PROPULSION SYSTEMS↗

Use of the Concept of Equivalent Biologically Effective Dose (BED) to Quantify the Contribution of Hyperthermia to Local Tumor Control in Radiohyperthermia Cervical Cancer Trials, and Comparison With Radiochemotherapy Results

Purpose: To express the magnitude of contribution of hyperthermia to local tumor control in radiohyperthermia (RT/HT) cervical cancer trials, in terms of the radiation-equivalent biologically effective dose (BED) and to explore the potential of the combined modalities in the treatment of this neoplasm. Materials and Methods: Local control rates of both arms of each study (RT vs. RT+HT) reported from randomized controlled trials (RCT) on concurrent RT/HT for cervical cancer were reviewed. By comparing the two tumor control probabilities (TCPs) from each study, we calculated the HT-related log cell-kill and then expressed it in terms of the number of 2 Gy fraction equivalents, for a range of tumor volumes and radiosensitivities. We have compared the contribution of each modality and made some exploratory calculations on the TCPs that might be expected from a combined trimodality treatment (RT+CT+HT). Results: The HT-equivalent number of 2-Gy fractions ranges from 0.6 to 4.8 depending on radiosensitivity. Opportunities for clinically detectable improvement by the addition of HT are only available in tumors with an alpha value in the approximate range of 0.22-0.28 Gy{sup -1}. A combined treatment (RT+CT+HT) is not expected to improve prognosis in radioresistant tumors. Conclusion: The most significant improvements in TCP, which may result from the combination of RT/CT/HT for locally advanced cervical carcinomas, are likely to be limited only to those patients with tumors of relatively low-intermediate radiosensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morita equivalence of noncommutative supertori

In this paper we study the extension of Morita equivalence of noncommutative tori to the supersymmetric case. The structure of the symmetry group yielding Morita equivalence appears to be intact but its parameter field becomes supersymmetrized having both body and soul parts. Our result is mainly in the two dimensional case in which noncommutative supertori have been constructed recently: The group SO(2,2,V{sub Z}{sup 0}), where V{sub Z}{sup 0} denotes Grassmann even number whose body part belongs to Z, yields Morita equivalent noncommutative supertori in two dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Local unitary equivalence and entanglement of multipartite pure states

The necessary and sufficient conditions for the equivalence of arbitrary n-qubit pure quantum states under local unitary (LU) operations derived in [B. Kraus, Phys. Rev. Lett. 104, 020504 (2010)] are used to determine the different LU-equivalence classes of up to five-qubit states. Due to this classification new parameters characterizing multipartite entanglement are found and their physical interpretation is given. Moreover, the method is used to derive examples of two n-qubit states (with n>2 arbitrary) which have the properties that all the entropies of any subsystem coincide; however, the states are neither LU equivalent nor can be mapped into each other by general local operations and classical communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equivalent Hamiltonians

I give a characterization of the conditions for two Hamiltonians to be equivalent, discuss the construction of the operators that relate equivalent Hamiltonians, and introduce variational methods that can select Hamiltonians with desirable features from the space of equivalent Hamiltonians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonrelativistic limit of quantum field theory in inertial and noninertial frames and the principle of equivalence

We discuss the nonrelativistic limit of quantum field theory in an inertial frame, in the Rindler frame and in the presence of a weak gravitational field, and attempt to highlight and clarify several subtleties. In particular, we study the following issues: (a) While the action for a relativistic free particle is invariant under the Lorentz transformation, the corresponding action for a nonrelativistic free particle is not invariant under the Galilean transformation, but picks up extra contributions at the end points. This leads to an extra phase in the nonrelativistic wave function under a Galilean transformation, which can be related to the rest energy of the particle even in the nonrelativistic limit. We show that this is closely related to the peculiar fact that the relativistic action for a free particle remains invariant even if we restrict ourselves to O(1/c{sup 2}) in implementing the Lorentz transformation. (b) We provide a brief critique of the principle of equivalence in the quantum mechanical context. In particular, we show how solutions to the generally covariant Klein-Gordon equation in a noninertial frame, which has a time-dependent acceleration, reduce to the nonrelativistic wave function in the presence of an appropriate (time-dependent) gravitational field in the c{yields}{infinity} limit, and relate this fact to the validity of the principle of equivalence in a quantum mechanical context. We also show that the extra phase acquired by the nonrelativistic wave function in an accelerated frame, actually arises from the gravitational time dilation and survives in the nonrelativistic limit. (c) While the solution of the Schroedinger equation can be given an interpretation as being the probability amplitude for a single particle, such an interpretation fails in quantum field theory. We show how, in spite of this, one can explicitly evaluate the path integral using the (nonquadratic) action for a relativistic particle (involving a square root) and obtain the Feynman propagator. Further, we describe how this propagator reduces to the standard path integral kernel in the nonrelativistic limit. (d) We show that the limiting procedures for the propagators mentioned above work correctly even in the presence of a weak gravitational field, or in the Rindler frame, and discuss the implications for the principle of equivalence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact lumped circuit model of discharges in DC accelerator using partial element equivalent circuit

DC Accelerators undergoes different types of discharges during its operation. A model depicting the discharges has been simulated to study the different transient conditions. The paper presents a Physics based approach of developing a compact circuit model of the DC Accelerator using Partial Element Equivalent Circuit (PEEC) technique. The equivalent RLC model aids in analyzing the transient behavior of the system and predicting anomalies in the system. The electrical discharges and its properties prevailing in the accelerator can be evaluated by this equivalent model. A parallel coupled voltage multiplier structure is simulated in small scale using few stages of corona guards and the theoretical and practical results are compared. The PEEC technique leads to a simple model for studying the fault conditions in accelerator systems. Compared to the Finite Element Techniques, this technique gives the circuital representation. The lumped components of the PEEC are used to obtain the input impedance and the result is also compared to that of the FEM technique for a frequency range of (0-200) MHz. (author)

43 PARTICLE ACCELERATORS↗

A Novel Equivalent Model of Active Distribution Networks Based on LSTM

Dynamic behaviors of distribution networks are of great importance for the power system analysis. Nowadays, due to the integration of the renewable energy generation, energy storage, plug-in electric vehicles, and distribution networks turn from passive systems to active ones. Hence, the dynamic behaviors of active distribution networks (ADNs) are much more complex than the traditional ones. The research interests how to establish an accurate model of ADNs in modern power systems are drawing a great deal of attention. In this paper, motivated by the similarities between power system differential algebraic equations and the forward calculation flows of recurrent neural networks (RNNs), a long short-term memory (LSTM) RNN-based equivalent model is proposed to accurately represent the ADNs. First, the adoption reasons of the proposed LSTM RNN-based equivalent model are explained, and its advantages are analyzed from the mathematical point of view. Then, the accuracy and generalization performance of the proposed model is evaluated using the IEEE 39-Bus New England system integrated with ADNs in the study cases. Here, it reveals that the proposed LSTM RNN-based equivalent model has a generalization capability to capture the dynamic behaviors of ADNs with high accuracy.

42 ENGINEERING↗

Equivalent Properties of Interfacial Void Defects at the CFRTP-adhesive Interface and Their Detrimental Effects on the Bonding Performance of Metal-CFRTP Dissimilar Joints

This paper revealed the detrimental effects of micro-scale air interfacial voids on the debonding at the interface of carbon-fiber-reinforced polyphthalamide (CFRPPA) and thermoset adhesive, representing a weak adherend-adhesive interface, within a dissimilar joint made of an aluminum alloy and a CFRPPA. The reduced lap shear strength of the joint, due to different void area fractions at the CFRPPA-adhesive interface, can be computationally described by using equivalent interfacial properties in the modeling to avoid the explicit modeling of the micro-scale interfacial voids. Such equivalent interfacial properties (e.g., interfacial normal strength, etc.) was found to have a non-linear relationship with respect to interfacial void area fraction as well as lap shear strength. This work has practical applications by utilizing equivalent interfacial properties for the analytical and/or computational design(s) of adhesively bonded joints.

Qiao, Yao↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-181: Proton Therapy Tissue-Equivalence of 3D Printed Materials

Purpose: This work investigated the proton tissue-equivalence of various 3D printed materials. Methods: Three 3D printers were used to create 5 cm cubic phantoms made of different plastics with varying percentages of infill. White resin, polylactic acid (PLA), and NinjaFlex plastics were used. The infills ranged from 15% to 100%. Each phantom was scanned with a CT scanner to obtain the HU value. The relative linear stopping power (RLSP) was then determined using a multi-layer ion chamber in a 200 MeV proton beam. The RLSP was measured both parallel and perpendicular to the print direction for each material. Results: The HU values of the materials ranged from lung-equivalent (−820 HU σ160) when using a low infill, to soft-tissue-equivalent 159 (σ12). The RLSP of the materials depended on the orientation of the beam relative to the print direction. When the proton beam was parallel to the print direction, the RLSP was generally higher than the RLSP in the perpendicular orientation, by up to 45%. This difference was smaller (less than 6%) for the materials with 100% infill. For low infill cubes irradiated parallel to the print direction, the SOBP curve showed extreme degradation of the beam in the distal region. The materials with 15–25% infill had wide-ranging agreement with a clinical HU-RLSP conversion curve, with some measurements falling within 1% of the curve and others deviating up to 45%. The materials with 100% infill all fell within 7% of the curve. Conclusion: While some materials tested fall within 1% of a clinical HU-RLSP curve, caution should be taken when using 3D printed materials with proton therapy, as the orientation of the beam relative to the print direction can result in a large change in RLSP. Further investigation is needed to measure how the infill pattern affects the material RLSP. This work was supported by PHS grant CA180803.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP2-05: Breast and Soft Tissue-Equivalent 3D Printed Phantoms for Imaging and Dosimetry

Purpose: The study has the goal to demonstrate that breast and soft tissue-equivalent phantoms for dosimetry applications in the diagnostic energy range can be fabricated using common 3D printing methods. Methods: 3D printing provides the opportunity to rapidly prototype uniquely designed objects from a variety of materials. Common 3D printers are usually limited to printing objects based on thermoplastic materials such as PLA, or ABS. The most commonly available plastic is PLA, which has a density significantly greater than soft tissue. We utilized a popular 3D printer to demonstrate that tissue specific phantom materials can be generated through the careful selection of 3D printing parameters. A series of stepwedges were designed and printed using a Makerbot Replicator2 3D printing system. The print file provides custom adjustment of the infill density, orientation and position of the object on the printer stage, selection of infill patterns, and other control parameters. The x-ray attenuation and uniformity of fabricated phantoms were evaluated and compared to common tissue-equivalent phantom materials, acrylic and BR12. X-ray exposure measurements were made using narrow beam geometry on a clinical mammography unit at 28 kVp on the series of phantoms. The 3D printed phantoms were imaged at 28 kVp to visualize the internal structure and uniformity in different planes of the phantoms. Results: By utilizing specific in-fill density and patterns we are able to produce a phantom closely matching the attenuation characteristics of BR12 at 28 kVp. The in-fill patterns used are heterogeneous, so a judicious selection of fill pattern and the orientation of the fill pattern must be made in order to obtain homogenous attenuation along the intended direction of beam propagation. Conclusions: By careful manipulation of the printing parameters, breast and soft tissue-equivalent phantoms appropriate for use at imaging energies can be fabricated using 3D printing techniques.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-06: Evaluation of the Imaging Performance of a Novel Water-Equivalent EPID

Purpose: To evaluate the megavoltage imaging performance of a novel, water-equivalent electronic portal imaging device (EPID) developed for simultaneous imaging and dosimetry applications in radiotherapy. Methods: A novel EPID prototype based on active matrix flat panel imager technology has been developed by our group and previously reported to exhibit a water-equivalent dose response. It was constructed by replacing all components above the photodiode detector in a standard clinical EPID (including the copper plate and phosphor screen) with a 15 × 15 cm{sup 2} array of plastic scintillator fibers. Individual fibers measured 0.5 × 0.5 × 30 mm{sup 3}. Spatial resolution was evaluated experimentally relative to that of a standard EPID with the thin slit technique to measure the modulation transfer function (MTF) for 6 MV x-ray beams. Monte Carlo (MC) EPID models were used to benchmark simulated MTFs against the measurements. The zero spatial frequency detective quantum efficiency (DQE(0)) was simulated for both EPID configurations and a preliminary optimization of the prototype was performed by evaluating DQE(0) as a function of fiber length up to 50 mm. Results: The MC-simulated DQE(0) for the prototype EPID configuration was ∼7 times greater than that of the standard EPID. The prototype’s DQE(0) also increased approximately linearly with fiber length, from ∼1% at 5 mm length to ∼11% at 50 mm length. The standard EPID MTF was greater than the prototype EPID’s for all spatial frequencies, reflecting the trade off between x-ray detection efficiency and spatial resolution with thick scintillators. Conclusion: This study offers promising evidence that a water-equivalent EPID previously demonstrated for radiotherapy dosimetry may also be used for radiotherapy imaging applications. Future studies on optimising the detector design will be performed to develop a next-generation prototype that offers improved megavoltage imaging performance, with the aim to at least match that of current clinical EPIDs. Funding for this project was provided by an Australian Research Council Linkage Project grant (2015) between The University of Sydney, South Western Sydney Local Health District and Perkin-Elmer Pty Ltd.

60 APPLIED LIFE SCIENCES↗