Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exercise Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Exercising Prediction Validation Methods for Analysis of Quiet Supersonic Overflight

En route noise certification procedures for quiet supersonic aircraft are in development under the International Civil Aviation Organization for a proposed standard that could enable civil supersonic overland flight. While these quiet supersonic aircraft do not exist yet, methods are being developed and evaluated using existing N-wave empirical datasets and low-boom simulation datasets. One potential aspect of future certification methods is the ability to use a validated prediction model to predict the certification noise level under reference day weather conditions. Methods to validate predictions, such as the two-sample t-test, Fisher’s combined probability test, two-sample Kolmogorov-Smirnov test, and equivalence testing, have been exercised and modified for this application. While some methods compare mean values, others compare values across the distribution, and a combination of methods can be used. The methods were applied to a subset of an N-wave dataset to demonstrate the applicability and identify potential areas for improvement. Atmospheric turbulence variability was included as a factor in these analyses through KZKFourier propagation simulations with parameters matching actual flights and weather conditions. Results are presented for six noise metrics (PL, ASEL, BSEL, DSEL, ESEL, and ISBAP), and plans to expand the analyses are discussed.

sonic boom↗

Descent and Landing Triggers for the Orion Multi-Purpose Crew Vehicle Exploration Flight Test-1

The Orion Multi-Purpose Crew Vehicle (MPCV) will perform a flight test known as Exploration Flight Test-1 (EFT-1) currently scheduled for 2014. One of the primary functions of this test is to exercise all of the important Guidance, Navigation, Control (GN&C), and Propulsion systems, along with the flight software for future flights. The Descent and Landing segment of the flight is governed by the requirements levied on the GN&C system by the Landing and Recovery System (LRS). The LRS is a complex system of parachutes and flight control modes that ensure that the Orion MPCV safely lands at its designated target in the Pacific Ocean. The Descent and Landing segment begins with the jettisoning of the Forward Bay Cover and concludes with sensing touchdown. This paper discusses the requirements, design, testing, analysis and performance of the current EFT-1 Descent and Landing Triggers flight software.

Bihari, Brian D.↗

HIFiRE-1 Turbulent Shock Boundary Layer Interaction - Flight Data and Computations

The Hypersonic International Flight Research Experimentation (HIFiRE) program is a hypersonic flight test program executed by the Air Force Research Laboratory (AFRL) and Australian Defence Science and Technology Organisation (DSTO). This flight contained a cylinder-flare induced shock boundary layer interaction (SBLI). Computations of the interaction were conducted for a number of times during the ascent. The DPLR code used for predictions was calibrated against ground test data prior to exercising the code at flight conditions. Generally, the computations predicted the upstream influence and interaction pressures very well. Plateau pressures on the cylinder were predicted well at all conditions. Although the experimental heat transfer showed a large amount of scatter, especially at low heating levels, the measured heat transfer agreed well with computations. The primary discrepancy between the experiment and computation occurred in the pressures measured on the flare during second stage burn. Measured pressures exhibited large overshoots late in the second stage burn, the mechanism of which is unknown. The good agreement between flight measurements and CFD helps validate the philosophy of calibrating CFD against ground test, prior to exercising it at flight conditions.

Turbulence↗

WISE-2005: LBNP/Treadmill and Resistive Exercise Countermeasures Maintain Aerobic Capacity during a 60-d Bed Rest

We have previously documented that supine treadmill exercise within lower body negative pressure (LBNPex) performed 6 sessions (raised dot) wk(sup -1) during 15- and 30-day bed rests (BR) maintained upright aerobic capacity (VO2pk). In the present study, ure are evaluating whether aerobic capacity is maintained during a 60-d BR when the LBNPex frequency is reduced to 2-4 sessions (raised dot) wk(sup -1) and resistance exercise (REX) is added 2-3 sessions (raised dot) wk(sup -1). Eight healthy women (32 plus or minus 4 yrs; 56.4 plus or minus 3.6 kg; 164 plus or minus 8 cm; mean plus or minus SD) performed maximal-exertion, graded treadmill tests before and 3 days after a 60-d, 6 deg. head-down tilt BR. (Earliest day the medical monitors would permit a maximal exercise test post-BR). During BR, four subjects performed no exercise (CON), while four other subjects (EX) performed LBNPex and REX on separate days. The LBNPex countermeasure employed an intermittent (40-80% pre-BR VO2pk), 40-min protocol against an LBNP pressure (-49 plus or minus 3 mmHg) applied to provide a footward force equivalent to 1.0-1.2 body weight. REX consisted of maximal concentric and eccentric supine leg press and heel raise exercises using a gravity-independent flywheel ergometer. Comparisons were performed using paired (within-group) or non-paired (between-group) t-tests. Three days post-BR, VO2pk of the CON group was reduced significantly from pre-BR (Pre:37.2 plus or minus 1.2, Post: 29.4 plus or minus 2 ml (raised dot) kg(sup -1) (raised dot) min(sup -1), P less than 0.05), while the VO2pk of the EX group was not significantly reduced (Pre: 39.6 plus or minus 1.9, Post: 38.0 plus or minus 0.6 ml (raised dot) kg(sup -1) (raised dot) min(sup -1)). Peak heart rate, ventilation, rating of perceived exertion, and respiratory exchange ratio were not significantly different between the two groups pre- and post-BR. These preliminary results suggest that the combined LBNPex and REX countermeasures may be sufficient to maintain upright aerobic capacity after long-duration space flights.

Schneider, Suzanne M.↗

Foot-ground reaction force during resistive exercise in parabolic flight

INTRODUCTION: An interim resistance exercise device (iRED) was designed to provide resistive exercise as a countermeasure to spaceflight-induced loss of muscle strength and endurance as well as decreased bone mineral density. The purpose of this project was to compare foot-ground reaction force during iRED exercise in normal gravity (1 G) vs. microgravity (0 G) achieved during parabolic flight. METHODS: There were four subjects who performed three exercises (squat, heel raise, and deadlift) using the iRED during 1 G and 0 G at a moderate intensity (60% of maximum strength during deadlift exercise). Foot-ground reaction force was measured in the three orthogonal axes (x, y, z) using a force plate, and the magnitude of the resultant force vector was calculated (r = square root(x2 + y2 + z2)). Linear displacement (LD) was measured using a linear transducer. Peak force (Fpeak) and an index of total work (TWi) were calculated using a customized computer program. Paired t-tests were used to test if significant differences (p < or = 0.05) were observed between 1 G and 0 G exercise. RESULTS: Fpeak and TWi measured in the resultant axis were significantly less in 0 G for each of the exercises tested. During 0 G, Fpeak was 42-46% and TWi was 33-37% of that measured during 1 G. LD and average time to complete each repetition were not different from 1 G to 0 G. CONCLUSIONS: Crewmembers who perform resistive exercises during spaceflight that include the movement of a large portion of their body mass will require much greater external resistive force during 0 G than 1 G exercise to provide a sufficient stimulus to maintain muscle and bone mass.

Physical Education and Training↗

Gait, Balance, Leg Strength, and Sprint Speed After Bedrest with LBNP Exercise

Microgravity and bedrest (BR) result in similar physiological decrements such as loss of muscle mass, muscle strength and balance. Previous studies analyzing exercise within lower body negative pressure (LBNP) have found that gait is similar in LBNP on a vertical treadmill and overground exercise on a horizontal treadmill. Since treadmill exercise is known to increase muscular strength and endurance, we tested the hypothesis that LBNP exercise on a vertical treadmill would prevent or attenuate many of the physical decrements which occur during bedrest. Based on our positive results from diverse tests of post-BR function, we believe that exercise within LBNP is worth pursuing as a countermeasure for reducing the physical deterioration that occurs during bedrest and microgravity.

Boda, Wanda L.↗

Evidence for altered alpha-adrenoreceptor responsiveness after a single bout of maximal exercise

We studied hemodynamic responses to alpha- and beta-receptor agonists in eight men to test the hypothesis that adrenoreceptor responsiveness is altered within 24 h of the performance of maximal exercise. Adrenoreceptor responsiveness was tested under two experimental conditions (with and without maximal exercise). Adrenoreceptor tests were performed 24 h after each subject performed graded upright cycle ergometry to volitional exhaustion. The 2 test days (experimental conditions) were separated by at least 1 wk, and the order of exercise and no-exercise conditions was counterbalanced. Steady-state graded infusions of phenylephrine (PE) and isoproterenol (Iso) were used to assess alpha- and beta-adrenoreceptor responsiveness, respectively. Slopes calculated from linear regressions between Iso and PE doses and changes in heart rate, blood pressure, and leg vascular resistance for each subject were used as an index of alpha- and beta-adrenoreceptor responsiveness. The slope of the relationship between heart rate and Iso with maximal exercise was 1773 +/- 164 beats x microm-1x kg-1x min-1 compared with 1987 +/- 142 beats x microg-1x kg-1x min-1 without exercise (P = 0.158), whereas the slopes of the relationship between vascular resistance to Iso were -438 +/- 123 peripheral resistance units (PRU) x microg-1x kg-1x min-1 with maximal exercise and -429 +/- 105 x microg-1x kg-1 x min-1 without exercise (P = 0.904). Maximal exercise was associated with greater (P < 0.05) vascular resistance (15.1 +/- 2.8 PRU x microg-1 kg-1x min-1) and mean arterial blood pressure (15.8 +/- 2.1 mmHg. microg-1x kg-1x min-1) responses to PE infusion compared with no exercise (9.0 +/- 2.0 PRU x microg-1 kg-1 x min-1 and 10.9 +/- 2.0 mmHg. microg-1x kg-1x min-1, respectively). These results provide evidence that a single bout of maximal exercise increases alpha1-adrenoreceptor responsiveness within 24 h without affecting beta-cardiac and vascular adrenoreceptor responses.

Non-NASA Center↗

Foot-Ground Reaction Force During Resistance Exercise in Parabolic Flight

An interim Resistance Exercise Device (iRED) was designed to provide resistive exercise as a countermeasure to space flight-induced loss of muscle strength and endurance as well as decreased bone mineral density. The purpose of this project was to compare foot-ground reaction force during iRED exercise in normal gravity (l-g) versus micro gravity (O-g) achieved during parabolic flight. METHODS: Four subjects performed three exercises using the iRED (squat, heel raise, and deadlift) during I-g and O-g at a moderate intensity (60% of maximum strength during deadlift exercise). Foot-ground reaction force was measured in three axes (x,y,z) using a force plate, and the magnitude of the resultant force vector was calculated (r = ~X 2 + y2 + Z2 ). Range of motion (ROM) was measured using a linear encoder. Peak force (PkF) and total work (TW) were calculated using a customized computer program. Paired t-tests were used to test if significant differences (p.::::0.05) were observed between I-g and O-g exercise. RESULTS: PkF and TW measured in the resultant axis were significantly less in O-g for each of the exercises tested. During O-g, PkF was 42-46% and TW was 33- 37% of that measured during I-g. ROM and average time to complete each repetition were not different from I-g to O-g. CONCLUSIONS: When performing exercises in which body mass is a portion of the resistance during I-g, PkF and TW measured during resistive exercise were reduced approximately 60-70% during O-g. Thus, a resistive exercise device during O-g will be required to provided higher resistances to induce a similar training stimulus to that on Earth.

Lee, Stuart M. C.↗

Mechanism Development, Testing, and Lessons Learned for the Advanced Resistive Exercise Device

The Advanced Resistive Exercise Device (ARED) has been developed at NASA Johnson Space Center, for the International Space Station (ISS) program. ARED is a multi-exercise, high-load resistive exercise device, designed for long duration, human space missions. ARED will enable astronauts to effectively maintain their muscle strength and bone mass in the micro-gravity environment more effectively than any other existing devices. ARED's resistance is provided via two, 20.3 cm (8 in) diameter vacuum cylinders, which provide a nearly constant resistance source. ARED also has a means to simulate the inertia that is felt during a 1-G exercise routine via the flywheel subassembly, which is directly tied to the motion of the ARED cylinders. ARED is scheduled to fly on flight ULF 2 to the ISS and will be located in Node 1. Presently, ARED is in the middle of its qualification and acceptance test program. An extensive testing program and engineering evaluation has increased the reliability of ARED by bringing potential design issues to light before flight production. Some of those design issues, resolutions, and design details will be discussed in this paper.

Lamoreaux, Christopher D.↗

C-MOS array design techniques

The entire complement of standard cells and components, except for the set-reset flip-flop, was completed. Two levels of checking were performed on each device. Logic cells and topological layout are described. All the related computer programs were coded and one level of debugging was completed. The logic for the test chip was modified and updated. This test chip served as the first test vehicle to exercise the standard cell complementary MOS(C-MOS) automatic artwork generation capability.

Feller, A.↗

Test results on re-use of reclaimed shower water: Summary

A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.

Verostko, C. E.↗

Magnetic resonance imaging and electromyography as indexes of muscle function

A hypothesis is tested that exercise-induced magnetic resonance (MR) contrast shifts would relate to electromyography (EMG) amplitude if both measures reflect muscle use during exercise. Both magnetic resonance images (MRI) and EMG data were obtained for separate eccentric (ECC) and cocentric (CON) exercise of increasing intensity for seven subjects 30-32 yr old. CON and ECC actions caused increased integrated EMG (IEMG) and T2 values which were strongly related with relative resistance. The rate of increase and absolute value of both T2 and IEMG were found to be greater for CON than for ECC actions. For both actions IEMG and T2 were correlated. Data obtained suggest that surface IEMG accurately reflects the contractile behavior of muscle and exercise-induced increases in MRI T2 values reflect certain processes that scale with muscle use.

Adams, Gregory R.↗

Ames Fitness Program

The Ames Fitness Program services 5,000 civil servants and contractors working at Ames Research Center. A 3,000 square foot fitness center, equipped with cardiovascular machines, weight training machines, and free weight equipment is on site. Thirty exercise classes are held each week at the Center. A weight loss program is offered, including individual exercise prescriptions, fitness testing, and organized monthly runs. The Fitness Center is staffed by one full-time program coordinator and 15 hours per week of part-time help. Membership is available to all employees at Ames at no charge, and there are no fees for participation in any of the program activities. Prior to using the Center, employees must obtain a physical examination and complete a membership package. Funding for the Ames Fitness Program was in jeopardy in December 1992; however, the employees circulated a petition in support of the program and collected more than 1500 signatures in only three days. Funding has been approved through October 1993.

Pratt, Randy↗

An assessment of unstructured grid technology for timely CFD analysis

An assessment of two unstructured methods is presented in this paper. A tetrahedral unstructured method USM3D, developed at NASA Langley Research Center is compared to a Cartesian unstructured method, SPLITFLOW, developed at Lockheed Fort Worth Company. USM3D is an upwind finite volume solver that accepts grids generated primarily from the Vgrid grid generator. SPLITFLOW combines an unstructured grid generator with an implicit flow solver in one package. Both methods are exercised on three test cases, a wing, and a wing body, and a fully expanded nozzle. The results for the first two runs are included here and compared to the structured grid method TEAM and to available test data. On each test case, the set up procedure are described, including any difficulties that were encountered. Detailed descriptions of the solvers are not included in this paper.

Kinard, Tom A.↗

Performance seeking control program overview

The Performance Seeking Control (PSC) program evolved from a series of integrated propulsion-flight control research programs flown at NASA Dryden Flight Research Center (DFRC) on an F-15. The first of these was the Digital Electronic Engine Control (DEEC) program and provided digital engine controls suitable for integration. The DEEC and digital electronic flight control system of the NASA F-15 were ideally suited for integrated controls research. The Advanced Engine Control System (ADECS) program proved that integrated engine and aircraft control could improve overall system performance. The objective of the PSC program was to advance the technology for a fully integrated propulsion flight control system. Whereas ADECS provided single variable control for an average engine, PSC controlled multiple propulsion system variables while adapting to the measured engine performance. PSC was developed as a model-based, adaptive control algorithm and included four optimization modes: minimum fuel flow at constant thrust, minimum turbine temperature at constant thrust, maximum thrust, and minimum thrust. Subsonic and supersonic flight testing were conducted at NASA Dryden covering the four PSC optimization modes and over the full throttle range. Flight testing of the PSC algorithm, conducted in a series of five flight test phases, has been concluded at NASA Dryden covering all four of the PSC optimization modes. Over a three year period and five flight test phases 72 research flights were conducted. The primary objective of flight testing was to exercise each PSC optimization mode and quantify the resulting performance improvements.

Orme, John S.↗

An Improved Automatic Classification of a Landsat/TM Image from Kansas (FIFE)

This research note shows the results of applying a new massively parallel version of the automatic classification program (AutoClass IV) to a particular Landsat/TM image. The previous results for this image were produced using a "subsampling" technique because of the image size. The new massively parallel version of AutoClass allows the complete image to be classified without "subsampling", thus yielding improved results. The area in question is the FIFE study area in Kansas, and the classes AutoClass found show many interesting subtle variations in types of ground cover. Displays of the spatial distributions of these classes make up the bulk of this report. While the spatial distribution of some of these classes make their interpretation easy, most of the classes require detailed knowledge of the area for their full interpretation. We hope that some who receive this document can help us in understanding these classes. One of the motivations of this exercise was to test the new version of AutoClass (IV) that allows for correlation among the variables within a class. The scatter plots associated with the classes show that this correlation information is important in separating the classes. The fact that the spatial distribution of each of these classes is far from uniform, even though AutoClass was not given information about positions of pixels, shows that the classes are due to real differences in the image.

Kanefsky, Bob↗

Renal and Cardio-Endocrine Responses in Humans to Simulated Microgravity

The volume regulating systems are integrated to produce an appropriate response to both acute and chronic volume changes. Their responses include changing the levels of the hormones and neural inputs of the involved systems and/or changing the responsiveness of their target tissues. Weightlessness during space travel produces a volume challenge that is unfamiliar to the organism. Thus, it is likely that these volume regulatory mechanisms may respond inappropriately, e.g., a decrease in total body volume in space and abnormal responses to upright posture and stress on return to Earth. A similar "inappropriateness" also can occur in disease states, e.g., congestive heart failure. While it is clear that weightlessness produces profound changes in sodium and volume homeostasis, the mechanisms responsible for these changes are incompletely understood. Confounding this analysis is sleep deprivation, common in space travel, which can also modify volume homeostatic mechanisms. The purpose of this project is to provide the required understanding and then to design appropriate countermeasures to reduce or eliminate the adverse effects of microgravity. To accomplish this we are addressing five Specific Aims: (1) To test the hypothesis that microgravity modifies the acute responsiveness of the renin-angiotensin-aldosterone system (RAAS) and renal blood flow; (2) Does simulated microgravity change the circadian rhythm of the volume- regulating hormones?; (3) Does simulated microgravity change the target tissue responsiveness to angiotensin 11 (AngII)?; (4) Does chronic sleep deprivation modify the circadian rhythm of the RAAS and change the acute responsiveness of this system to posture beyond what a microgravity environment alone does? and (5) What effect does salt restriction have on the volume homeostatic and neurohumoral responses to a microgravity environment? Because the RAAS plays a pivotal role in blood pressure control and volume homeostasis, it likely is a major mediator of the adaptive cardio-renal responses observed during space missions and is a special focus of this project. Thus, the overall goal of this project is to assess the impact of microgravity and sleep deprivation in humans on volume-regulating systems. To achieve this overall objective, we are evaluating renal blood flow and the status and responsiveness of the volume- regulating systems (RAAS, atrial natriuretic peptide and vasopressin), and the adrenergic system (plasma and urine catecholamines) in both simulated microgravity and normal gravity with and -Without sleep deprivation. Furthermore, the responses of the volume homeostatic mechanisms to acute stimulation by upright tilt testing, standing and exercise are being evaluated before and after achieving equilibrium with these interventions.

Williams, Gordon H.↗

Effect of 3-Day Bed Rest on the Basal Sympathetic Activity and Responsiveness of this System to Physiological Stimuli In Athletes and Sedentary Subjects

The aims of this study were: (1) to examine the effect of three days of bed rest (BR) on basal plasma epinephrine [E] and norepinephrine [NE] and the catecholamine responses to various physiological stimuli, and (2) to find out whether previous physical activity modifies effects of BR. In the first series, 29 young men (11 sedentary students, 8 endurance and 10 strength trained athletes) were submitted to oral glucose tolerance test in supine position and to active orthostatic test before and after 3 days of BR. Plasma [E] and [NE] were measured after overnight fast (basal condition), at 60, 120 and 180 min after glucose ingestion (70 a), and at the 8th min of unsupported standing. In the second series, other 22 subjects (12 sedentary students, 10 endurance and 10 strength trained athletes) were submitted to 2 min cold pressor test (CPT) and exercise. Plasma E and NE were determined in the supine position after overnight fast and at 60th and 120th s of hand cooling. Then, after breakfast followed by 2-3 hour sitting, the subjects performed cycle ergometer exercise with workload increasing until volitional exhaustion. Plasma [E] and [NE] were determined at the end of each load. Plasma catecholamines were determined made radioenzymatically. After BR, basal plasma [NE] was decreased in endurance and strength athletes (p<0.01) but not in sedentary subjects. In neither group BR affected the basal [E]. Responses of both catecholamines to glucose load were diminished after BR in all three groups (p<0.05) but the effect was most pronounced in the endurance athletes. All subjects tolerated well 8-min standing although their heart rate response was increased after BR. Plasma catecholamine responses standing were not significantly affected by BR in either group but the plasma [NE] and [E] during standing were lowered after BR in endurance athletes (p<0.01). BR did not affect blood pressure and catecholamine responses to CPT. The pre- and post-exercise plasma catecholamines were similar before and after BR although the subjects achieved lower maximal loads after BR. In endurance athletes the threshold for plasma NA rise occurred at lower work intensity after than before BR (p<0.05).

Smorawinski, Jerzy↗