Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exhaust”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cost Scaling of a Real-World Exhaust Waste Heat Recovery Thermoelectric Generator: A Deeper Dive

Cost is equally important to power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG) in many transportation and industrial energy recovery applications. In many cases the system design that minimizes cost (e.g., the $/W value) can be very different than the design that maximizes the system's efficiency or power density, and it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent cost analysis work and using more detailed system modeling, an enhanced cost scaling analysis of a waste heat recovery thermoelectric generator with more detailed, coupled treatment of the heat exchangers has been performed. In this analysis, the effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances that maximize power output are considered. This coupled thermal and thermoelectric treatment of the exhaust waste heat recovery thermoelectric generator yields modified cost scaling and design optimization equations, which are now strongly dependent on the heat leakage fraction, exhaust mass flow rate, and heat exchanger effectiveness. This work shows that heat exchanger costs most often dominate the overall TE system costs, that it is extremely difficult to escape this regime, and in order to achieve TE system costs of $1/W it is necessary to achieve heat exchanger costs of $1/(W/K). Minimum TE system costs per watt generally coincide with maximum power points, but Preferred TE Design Regimes are identified where there is little cost penalty for moving into regions of higher efficiency and slightly lower power outputs. These regimes are closely tied to previously-identified low cost design regimes. This work shows that the optimum fill factor Fopt minimizing system costs decreases as heat losses increase, and increases as exhaust mass flow rate and heat exchanger effectiveness increase. These findings have profound implications on the design and operation of various thermoelectric (TE) waste heat 3 recovery systems. This work highlights the importance of heat exchanger costs on the overall TEG system costs, quantifies the possible TEG performance-cost domain space based on heat exchanger effects, and provides a focus for future system research and development efforts.

cost analysis↗

Green's Function Applicable to Turbofan Exhaust Noise in Jets with an External Center-Body

The problem of propagation of sound across the shear layer in a turbofan jet exhaust with an external center-body is discussed. The wave equation of interest is the compressible Rayleigh equation. Two forms of the equation are considered, and the Green's function solutions, subject to appropriate surface conditions on the center-body and flight condition in the ambient, are presented. Directivity studies in a heated exhaust at temperature ratio of 2.0 and Mach number 0.90 indicate that a rigid center-body tends to increase the sound propagation at forward angles relative to an exhaust without a center-body, while application of suitable surface liner may significantly reduce this enhancement.

Noise↗

Green's Function Applicable to Turbofan Exhaust Noise in Jets with an External Center-Body

The problem of propagation of sound across the shear layer in a turbofan jet exhaust with an external center-body is discussed. The wave equation of interest is compressible Rayleigh equation. Two forms of the equation are considered, and the Green's function solutions subject to appropriate surface conditions on the center-body and flight condition in the ambient are presented. Directivity studied in a heated exhaust at temperature ratio of 2.0 and Mach number 0.90 indicate that a rigid center-body tends to increase the sound propagation at forward angles relative to an exhaust without a center-body, while application of suitable surface liner may significantly reduce this enhancement. A general form of the far-field solution to the propagation equation in a parallel flow under supersonic conditions and in the neighborhood of the shear layer singularity is also discussed.

Noise↗

Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple

A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.

FUEL-AIR MIXTURES↗

Oxide_Oxide Ceramic Matrix Composite (CMC) Exhaust Mixer Development in the NASA Environmentally Responsible Aviation (ERA) Project

LibertyWorks®, a subsidiary of Rolls-Royce Corporation, first studied CMC (ceramic matrix composite) exhaust mixers for potential weight benefits in 2008. Oxide CMC potentially offered weight reduction, higher temperature capability, and the ability to fabricate complex-shapes for increased mixing and noise suppression. In 2010, NASA was pursuing the reduction of NOx emissions, fuel burn, and noise from turbine engines in Phase I of the Environmentally Responsible Aviation (ERA) Project (within the Integrated Systems Research Program). ERA subtasks, including those focused on CMC components, were being formulated with the goal of maturing technology from Proof of Concept Validation (Technology Readiness Level 3 (TRL 3)) to System/Subsystem or Prototype Demonstration in a Relevant Environment (TRL 6). LibertyWorks®, a subsidiary of Rolls-Royce Corporation, first studied CMC (ceramic matrix composite) exhaust mixers for potential weight benefits in 2008. Oxide CMC potentially offered weight reduction, higher temperature capability, and the ability to fabricate complex-shapes for increased mixing and noise suppression. In 2010, NASA was pursuing the reduction of NOx emissions, fuel burn, and noise from turbine engines in Phase I of the Environmentally Responsible Aviation (ERA) Project (within the Integrated Systems Research Program). ERA subtasks, including those focused on CMC components, were being formulated with the goal of maturing technology from Proof of Concept Validation (Technology Readiness Level 3 (TRL 3)) to System/Subsystem or Prototype Demonstration in a Relevant Environment (TRL 6). Oxide CMC component at both room and elevated temperatures. A TRL≈5 (Component Validation in a Relevant Environment) was attained and the CMC mixer was cleared for ground testing on a Rolls-Royce AE3007 engine for performance evaluation to achieve TRL 6.

propulsion↗

Spectroscopic studies of the exhaust plume of a quasi-steady MPD accelerator

Spectroscopic and photographic investigations are reported that reveal a complex azimuthal species structure in the exhaust plume of a quasi-steady argon MPD accelerator. Over a wide range of operating conditions the injected argon remains collimated in discrete jets which are azimuthally in line with the six propellant injector orifices. The regions between these argon jets, including the central core of the exhaust flow, are occupied by impurities such as carbon, hydrogen and oxygen ablated from the Plexiglas back plate of the arc chamber. The features of this plume structure are found to be dependent on the arc current and mass flow rate. It is found that nearly half the observed velocity is attained in an acceleration region well downstream of the region of significant electromagnetic interaction. Recombination calculations show that the ionization energy is essentially frozen.

Bruckner, A. P.↗

Aeroacoustic characteristics of jet flap type exhausts.

This work which is intended to shed more light on the acoustic and fluid dynamic characteristics of jet flap type exhaust flows, reports and discusses some typical experimental results obtained with cold model air jets in a reverberation chamber. Acoustic data on the total sound power output and the overall noise spectrum of various jet flap configurations are given and compared with data from conventional circular jets. In addition various flow data for the same jets resulting from hot wire measurements are reported and general conclusions are obtained regarding the expected noise source distribution. The results indicate the dependence of the acoustic and flow characteristics on the major nozzle parameters. For the jet flaps the total radiated sound power is found to follow a 3 to 6 power of the exhaust velocity while for the circular jets the 8 power law is confirmed. The noise produced in the secondary mixing region downstream of the flap trailing edge tends to exceed the noise issuing from the primary mixing region.

Gruschka, H. D.↗

Biological effects of fuel and exhaust components from spacecraft descent engines employing hydrazine

The effect of the products of the Viking terminal descent engine fuel upon possible extraterrestrial life at the Martian landing site is examined. The effects of the engine exhaust, the hydrazine fuel, and the breakdown products of the latter on terrestrial microorganisms have been studied. The results indicate that the gaseous exhaust products would probably not be hazardous to microorganisms, but that liquid hydrazine would be lethal.

Lehwalt, M. E.↗

Simultaneous film and convection cooling of a plate inserted in the exhaust stream of a gas turbine combustor

Data were obtained on a parallel-flow film- and convection-cooled test section placed in the exhaust stream of a rectangular-sector combustor. The combustor was operated at atmospheric pressure and at exhaust temperatures of 589 and 1033 K (600 and 1400 F). The cooling air was at ambient pressure and temperature. Test results indicate that it is better to use combined film and convection cooling rather than either film or convection cooling alone for a fixed total coolant flow. An optimum ratio of film to convection cooling flow rates was determined for the particular geometry tested. The experimental results compared well with calculated results.

Marek, C. J.↗

Exhaust plume and contamination characteristics of a bipropellant (MMH/N2O4) RCS thruster

Results are presented for three recent tests in a series of thruster contamination experiments made in liquid helium-cooled environmental facility. The contaminating effects encountered on various materials, surfaces, and components, due to the exhaust products from a 5-pound thrust, bipropellant (MMH/N2O4) thruster are investigated. The angular distribution of plume effects around the periphery of the thruster established by transmittance changes of quartz samples over the wavelength range from 0.2 to 2.0 micrometer is studied, along with mass deposition rates at a specific location measured with a quartz crystal microbalance for three different experiments. Quadrupole mass spectrometer measurements of the exhaust products over the mass number range from 12 to 75; infrared transmittance measurements of contaminated samples for the wavelength range from 2.5 to 15 microns; and infrared transmittance measurements of residue from the thruster nozzle are also considered.

Spisz, E. W.↗

Flight investigation of acoustic and thrust characteristics of several exhaust nozzles installed on underwing nacelles on an F106 airplane

To determine flyover noise and thrust and to investigate whether flight velocity significantly affects the noise of exhaust nozzles, a series of flight tests was conducted on three different exhaust nozzles of a type suitable for supersonic transport aircraft. The tests were conducted using an F-106B aircraft modified to carry two underwing nacelles, each containing a calibrated turbojet engine. A flyover altitude of 91 meters (300 ft) and a Mach number of 0.4 provided acoustic data that were repeatable to within + or -1.5 PNdB. Flyover results showed that an auxiliary inlet ejector nozzle was the quietest of the nozzles tested; flight velocity appeared to reduce its noise.

Burley, R. R.↗

An analytical analysis of the dispersion predictions for effluents from the Saturn 5 and Scout-Algol 3 rocket exhausts

Predictions of the spatial concentration mapping of the potentially toxic constituents of the exhaust effluents from a launch of a Saturn 5 and of a Scout-Algol 3 vehicle utilizing the NASA/MSFC Multilayer Diffusion Program are provided. In the case of the Saturn 5, special attention was given to the concentration fields of carbon monoxide with a correlation of carbon dioxide concentrations. The Scout-Algol 3 provided an example of the centerline concentrations of hydrogen chloride, carbon monoxide, and alumina under typical meteorological conditions. While these results define the specific environmental impact of these two launches under the meteorological conditions existing during launches, they also provide a basis for the empirical monitoring of the constituents of the exhaust effluents of these vehicles.

Stephens, J. B.↗

Plasma electrolytes, pH, and ECG during and after exhaustive exercise.

Ten men worked on a bicycle ergometer at increasing work loads to exhaustion in 15 min. Each performed one test breathing air and another with added CO2 in random sequence. ECG was recorded during exercise and for 30 min of recovery. Arterial samples for blood gases, pH, and electrolytes were drawn at rest, in the last minute of exercise and at 1, 4, 10, 20, and 30 min thereafter. A striking increase in the amplitude of T and P waves was observed reaching a maximum in the first 2 min after exercise. All electrolytes measured were increased at the end of exercise, most markedly potassium (60%) and phosphorus (53%). Potassium dropped faster than all others to below resting values in 4 min coinciding with the lowest levels in plasma bicarbonate. ECG alterations were not closely related in time with any single factor such as potassium, but appeared to reflect an interaction of the transient mineral and acid-base imbalance during and immediately following exhaustive exercise.

Coester, N.↗