Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraterrestrial Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Long-term changes in composition of solar particles implanted in extraterrestrial materials

Analysis of lunar surface samples for elements implanted therein by solar corpuscular radiation reveals evidence for the following compositional changes over a time period between 1.5 and 3 Gyr: 50-percent decreases in the ratios He-4/Ar-36 and Xe/Ar-36; a 20-percent increase in the ratio He-3/He-4; a 3-percent increase in the ratio Ne-20/Ne-22; and a 50-percent increase in the ratio N-15/N-14. The causes of these changes are not resolved at this time but may include (1) a change in acceleration conditions of the solar wind, (2) a change in flux of solar energetic particles relative to that of the solar wind, and (3) a change in composition of the solar convective zone. There is good evidence for a long-term decrease in the solar-wind flux.

Kerridge, J. F.↗

GLC of amino acids - A survey of contamination.

Analyses of biological substances and geochemical samples, of both terrestrial and extraterrestrial origin, are reported for amino acids at the 1-10 nanogram per gram level achieved by gas-liquid and ion-exchange chromatographic methods. These studies have shown that nanogram quantities of amino acids, present in water extracts of geochemical samples or in other samples of low amino acid concentration, can be successfully determined only if the researcher is well aware of the possible sources of contamination.

Rash, J. J.↗

Mobile/Modular BSL-4 Facilities for Meeting Restricted Earth Return Containment Requirements

NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection Office require sample containment and biohazard testing in a receiving laboratory as directed by NASA Procedural Requirement (NPR) 8020.12D - ensuring the preservation and protection of Earth and the sample. Currently, NPR 8020.12D classifies Restricted Earth Return for robotic sample return missions from Mars, Europa, and Enceladus with the caveat that future proposed mission locations could be added or restrictions lifted on a case by case basis as scientific knowledge and understanding of biohazards progresses. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, Biosafety Level (BSL) 4 standards and protocols are used to study the most dangerous high-risk diseases and unknown biological agents on Earth. Over 30 BSL-4 facilities have been constructed worldwide with 12 residing in the United States; of theses, 8 are operational. In the last two decades, these brick and mortar facilities have cost in the hundreds of millions of dollars dependent on the facility requirements and size. Previous mission concept studies for constructing a NASA sample receiving facility with an integrated BSL-4 quarantine and biohazard testing facility have also been estimated in the hundreds of millions of dollars. As an alternative option, we have recently conducted an initial trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a faction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in approximately 90% cost reduction when compared to traditional construction methods without compromising the preservation of the sample or Earth.

Calaway, M. J.↗

Liquid Chromatography-Mass Spectrometry Interface for Detection of Extraterrestrial Organics

The OASIS (Organics Analyzer for Sampling Icy surfaces) microchip enables electrospray or thermospray of analyte for subsequent analysis by the OASIS time-of-flight mass spectrometer. Electrospray of buffer solution containing the nucleobase adenine was performed using the microchip and detected by a commercial time-of-flight mass spectrometer. Future testing of thermospray and electrospray capability will be performed using a test fixture and vacuum chamber developed especially for optimization of ion spray at atmosphere and in low pressure environments.

extraterrestrial organics↗

Mobile/Modular BSL-4 Containment Facilities Integrated into a Curation Receiving Laboratory for Restricted Earth Return Missions

NASA robotic sample return missions designated Category V Restricted Earth Return by the NASA Planetary Protection (PP) Office require sample containment and biohazard testing upon return to Earth. Since the 1960s, sample containment from an unknown extraterrestrial biohazard have been related to the highest containment standards and protocols known to modern science. Today, this is Biosafety Level (BSL) 4 containment. In the U.S., the Biosafety in Microbiological and Biomedical Laboratories publication authored by the U.S. Department of Health and Human Services (HHS): Public Health Service, Centers for Disease Control and Prevention, and the National Institutes of Health houses the primary recommendations, standards, and design requirements for all BSL labs. Past mission concept studies for constructing a NASA Curation Receiving Laboratory with an integrated BSL-4 quarantine and biohazard testing facility have been estimated in the hundreds of millions of dollars (USD). As an alternative option, we have conducted a trade study for constructing a mobile and/or modular sample containment laboratory that would meet all BSL-4 and planetary protection standards and protocols at a fraction of the cost. Mobile and modular BSL-2 and 3 facilities have been successfully constructed and deployed world-wide for government testing of pathogens and pharmaceutical production. Our study showed that a modular BSL-4 construction could result in ~ 90% cost reduction when compared to traditional BSL-4 construction methods without compromising the preservation of the samples or Earth. For the design/construction requirements of a mobile/modular BSL-4 containment, we used the established HHS document standards and protocols for manipulation of agents in Class III Biosafety Cabinets (BSC; i.e., negative pressure gloveboxes) that are currently followed in operational BSL-4 facilities in the U.S.

Calaway, Michael J.↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system has been guided by our under-standing of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure, and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-excesses of chiral amino acids or sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. However, studies of primitive meteorites have revealed that they contain extraterrestrial amino acids and sugar acids with large enantiomeric excesses (60% and higher) that resulted from non-biological processes [1], complicating the use of chiral asymmetry by itself as a definitive biosignature. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, is an objective of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks by the Sample Analysis at Mars (SAM) instrument suite on Mars [2-5], NASA’s Curiosity rover has found evidence of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars [5], indigenous achiral amino acids have been identified in one martian meteorite [6]. It is expected that amino acid racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [7]. The ESA/Roscosmos ExoMars mission scheduled for launch next year includes the Rosalind Franklin rover designed to acquire samples from a depth of ~2 m and deliver them to a suite of instruments, including the Mars Organic Molecule Analyzer (MOMA). The MOMA instrument contains a wet chemistry experiment designed specifically for the detection of amino acids and measurement of their enantiomeric compositions [8]. The complexity and limited duration of spaceflight operations, and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic com-pounds in ancient rocks, make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, bulk and molecule-specific isotopic, and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars derives from bio-tic or abiotic processes. Ultimately, Mars Sample Return of rock cores collected by NASA’s Perseverance rover may be our best chance of identifying chemical biosignatures, including any chiral amino acid asymmetry resulting from a past or present martian biota, if one ever existed on Mars. Here we review our current knowledge of the distributions, and enantiomeric and isotopic com-positions of amino acids found in meteorites compared to terrestrial biochemistry. We also propose a set of measurement criteria that should be used to help establish the sources of any amino acids detected in samples returned from Mars using state-of-the-art gas and liquid chromatography mass spectrometry techniques [1].

D P Glavin↗

A Search for Extraterrestrial Amino Acids in Polar Ice: A Progress Report

Fifteen polar ice samples-fourteen from Greenland and one from Antarctica-have been analyzed for the extraterrestrial amino acid alpha-aminoisobutyric acid (AIB) in an effort to estimate the flux of interplanetary organic material to the Earth's surface. Only one sample (Greenland GISP II, 4270-4440 years old) contains detectable amounts of AIB, apparently the signature of a transient delivery event. The maximum oceanic concentration of AIB from such an event would be less than 10(exp-9) M.

Bada, Jeffrey L.↗

Volatile/mobile trace elements in meteoritic, non-lunar basalts: Guides to Martian sample contents

A variety of genetic processes on or in extraterrestrial objects can be examined by study of volatile/mobile trace elements. Doubtless, considerable efforts will be expended on determining these elements in returned Martian samples. The purpose is to estimate levels of such elements expected to be present in returned Martian samples. Some ideas about Martian genesis were already advanced from the volatile/mobile element contents in SNC meteorites, assuming that Mars was their parent body. Even is Mars and the SNC meteorite parent body are identical, compositional ranges for returned Martian samples should exceed those of SNC meteorites. It is expected, therefore, that Martian samples returned from locations other than Polar regions will have indigenous volatile/mobile element contents within howardite-diogenite ranges. Elements with strong lithophile tendences may be more abundant, as they are in many lunar samples. Most of these elements should be at ppb levels except for Co, Ga, Zn, and Rb, which should lie at ppm levels. If Martian volcanism was accompanied by fumarolic emanations, it should be reflected in occasional huge enrichments of mobile trance elements, as in lunar meteorite Y 791197. During collection and transport Earthward, samples must be contained under conditions appropriate to ppb concentrations. Materials must be used that will not cause contamination which occurred during the Apollo program, where indium from seals contaminated many samples.

Lipschutz, M. E.↗

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system is currently guided by our understanding of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-enantiomeric excesses of chiral amino acids and sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, remains a key goal of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks on Mars [1-3], NASA’s Curiosity rover has significantly advanced our understanding of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars, if they were present, it is expected that amino acid hydrolysis and racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [4]. One of ESA’s Rosalind Franklin rover payload instruments called the Mars Organic Molecule Analyzer (MOMA) includes a wet chemistry package capable of measuring the enantiomeric ratios of any chiral amino acids present at part-per-million concentrations or higher [5]. The complexity and limited duration of spaceflight operations and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic compounds in ancient rocks make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, and isotopic studies and molecule-specific isotopic and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars comes from biotic or abiotic sources. Ultimately, sample return may be our best chance of identifying chemical biosignatures from a past or present martian biota, if one ever existed on Mars. NASA’s Perseverance rover will collect dozens of surface sample cores for possible future return to Earth by NASA and ESA. Here we review our current knowledge of the distributions and enantiomeric and isotopic compositions of non-biological amino acids found in meteorites compared to terrestrial biochemistry and propose a set of measurement criteria that should be used to help establish the origin of any chiral asymmetry detected in samples from Mars [6].

Daniel P Glavin↗

Applicability of La-Ce systematics to planetary samples

Cesium isotopic compositions in several terrestrial and extraterrestrial materials were determined in order to investigate the applicability of using Ce as an isotropic tracer to geological processes. A tenuous anticorrelation was observed between (epsilon)Ce and (epsilon)Nd for terrestrial basalts and granites, indicating that with some improvement in analytical techniques the Ce isotopic composition may prove useful as tracer for geological processes. A very low (epsilon)Ce predicted from the Ce anomaly in the REE pattern of the Kholar L3 chondrite was not observed, indicating that the anomaly may be caused by terrestrial contamination or alteration.

Nakamura, N.↗

Organic Matter in Extraterrestrial Water-Bearing Salt Crystals

Introduction: Direct samples of early Solar System fluids are present in two thermally-metamorphosed ordinary chondrite regolith breccias (Monahans (1998) [H5] and Zag [H3-6]), which were found to contain brine-bearing halite (NaCl) crystals that have been added to the regolith of an S-type asteroid following asteroidal metamorphism [1, 2]. The brine-bearing halite grains were proposed to be formed on an icy C-type asteroids (possibly Ceres), and transferred to an S-type asteroid via cryovolcanic event(s) [3]. A unique aspect of these halites is that they contain abundant organic rich solid inclusions hosted within the halites alongside the water inclusions. Methods: We analyzed in detail the compositions of the organic solids and the amino acid content of the halite crystals with two-step laser desorption/laser ionization mass spectrometry (L(sup 2) MS), Raman spectroscopy, X-ray absorption near edge structure (XANES), nanoscale secondary ion mass spectrometry (NanoSIMS), and ultra-performance liquid chromatography fluorescence detection and quadrupole time of flight hybrid mass spectrometry (UPLC-FD/QToF-MS). Results and Discussion: The L(sup 2) MS results show signatures of low-mass polyaromatic hydro-carbons (PAHs) indicated by sequences of peaks separated by 14 atomic mass units (amu) due to successive addition of methylene (CH2) groups to the PAH skeletons [4]. Raman spectra of the micron-sized solid inclusions of the halites indicate the presence of abundant and highly variable organic matter that include a mixture of short-chain aliphatic compounds and macromolecular carbon. C-XANES analysis identified C-rich areas with peaks at 285.0 eV (aromatic C=C) and 286.6 eV (vinyl-keto C=O). However, there is no 1s-sigma* exciton peak (291.7 eV) that is indicative of the development of graphene structure [5], which suggests the organics were synthesized cold. Na-noSIMS analyses show C-rich and N-rich areas that exhibit similar isotopic values with that of the IOM in the unweathered CR chondrites and less metamorphosed meteorites [6], and are moderately enriched in N-15 (delta N-15 = 106.1-164.5 per mille). The total amino acid distribution and abundance of the Zag matrix (approximately 1,940 parts per billion [ppb]) is comparable to other ordinary chondrites (60-3,330 ppb) [7, 8]. While the Zag matrix is gamma-ABA and EACA-deficient, the halite is shown to exhibit an opposite trend and is almost depleted in amino acids. The striking difference in the amino acid contents between the halite and matrix indicates their separate synthetic origins. Conclusion: Abundant, primitive, and highly-diverse N-15-rich organic compounds were detected in brine-water bearing halite crystals that were synthesized on a cryovolcanically-active asteroid. Our study suggests that the asteroidal parent body where the halite precipitated, potentially Ceres, is a host to abundance large variety organic precursors. Insoluble organic matter and amino acids can be synthesized from similar organic precusors under hydrous conditions [9].We envision that similar organic synthetic processes could have occurred on Ceres that synthesized organic solids as well as biologically relevant molecules.

Chan, Q. H. S.↗

Isotopic composition of hydrogen in insoluble organic matter from cherts

Robert (1989) reported the presence of unusually enriched hydrogen in the insoluble HF-HCl residue extracted from two chert samples of Eocene and Pliocene ages. Since the presence of heavy hydrogen might be due to the incorporation of extraterrestrial materials, we desired to reexamine the same samples to isolate the D-rich components. Our experiments did not reveal any D-rich components, but the hydrogen isotope composition of the insoluble residue of the two chert samples was well within the range expected for terrestrial organic matter. We also describe a protocol that needs to be followed in the hydrogen isotope analysis of any insoluble organic matter.

Non-NASA Center↗

Strategies for Distinguishing Abiotic Chemistry from Martian Biochemistry in Samples Returned from Mars

A key goal in the search for evidence of extinct or extant life on Mars will be the identification of chemical biosignatures including complex organic molecules common to all life on Earth. These include amino acids, the monomer building blocks of proteins and enzymes, and nucleobases, which serve as the structural basis of information storage in DNA and RNA. However, many of these organic compounds can also be formed abiotically as demonstrated by their prevalence in carbonaceous meteorites [1]. Therefore, an important challenge in the search for evidence of life on Mars will be distinguishing between abiotic chemistry of either meteoritic or martian origin from any chemical biosignatures from an extinct or extant martian biota. Although current robotic missions to Mars, including the 2011 Mars Science Laboratory (MSL) and the planned 2018 ExoMars rovers, will have the analytical capability needed to identify these key classes of organic molecules if present [2,3], return of a diverse suite of martian samples to Earth would allow for much more intensive laboratory studies using a broad array of extraction protocols and state-of-theart analytical techniques for bulk and spatially resolved characterization, molecular detection, and isotopic and enantiomeric compositions that may be required for unambiguous confirmation of martian life. Here we will describe current state-of-the-art laboratory analytical techniques that have been used to characterize the abundance and distribution of amino acids and nucleobases in meteorites, Apollo samples, and comet- exposed materials returned by the Stardust mission with an emphasis on their molecular characteristics that can be used to distinguish abiotic chemistry from biochemistry as we know it. The study of organic compounds in carbonaceous meteorites is highly relevant to Mars sample return analysis, since exogenous organic matter should have accumulated in the martian regolith over the last several billion years and the analytical techniques previously developed for the study of extraterrestrial materials can be applied to martian samples.

Glavin, D. P.↗

Development of a Piezoelectric Rotary Hammer Drill

The Piezoelectric Rotary Hammer Drill is designed to core through rock using a combination of rotation and high frequency hammering powered by a single piezoelectric actuator. It is designed as a low axial preload, low mass, and low power device for sample acquisition on future missions to extraterrestrial bodies. The purpose of this internship is to develop and test a prototype of the Piezoelectric Rotary Hammer Drill in order to verify the use of a horn with helical or angled cuts as a hammering and torque inducing mechanism. Through an iterative design process using models in ANSYS Finite Element software and a Mason's Equivalent Circuit model in MATLAB, a horn design was chosen for fabrication based on the predicted horn tip motion, electromechanical coupling, and neutral plane location. The design was then machined and a test bed assembled. The completed prototype has proven that a single piezoelectric actuator can be used to produce both rotation and hammering in a drill string through the use of a torque inducing horn. Final data results include bit rotation produced versus input power, and best drilling rate achieved with the prototype.

sampling↗

A Coordinated Focused Ion Beam/Ultramicrotomy Technique for Serial Sectioning of Hayabusa Particles and Other Returned Samples

Recent sample return missions, such as NASA's Stardust mission to comet 81P/Wild 2 and JAXA's Hayabusa mission to asteroid 25143 Itokawa, have returned particulate samples (typically ~5-50 μm) that pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on how the samples are prepared for analysis. This also holds true for other extraterrestrial materials, including interplanetary dust particles, micrometeorites and lunar regolith grains. Traditionally, particulate samples have been prepared using microtomy techniques (e.g., [1]). However, for hard mineral particles ≳20 μm, microtome thin sections are compromised by severe chatter and sample loss. For these difficult samples, we have developed a hybrid technique that combines traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for the in situ investigation of grain surfaces and interiors. Using this method, we have increased the number of FIB-SEM prepared sections that can be recovered from a particle with dimensions on the order of tens of μms. These sections can be subsequently analyzed using a variety of electron beam techniques. Here, we demonstrate this sample preparation technique on individual lunar regolith grains in order to study their space-weathered surfaces. We plan to extend these efforts to analyses of individual Hayabusa samples.

Berger, E. L.↗