New focusing multilayer structures for X-ray plasma spectroscopy

New focusing short-period multilayer structures are developed which opens up wide possibilities for X-ray and VUV spectroscopy. Multilayer structures are deposited on a flat surface of a mica crystal which is then bent to a small-radius cylinder. The use of this structure in a von Hamos spectrometer for X-ray laser plasma diagnostics is demonstrated. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopy of photoionisation processes

A method is demonstrated which combines the ionisation of free molecules by a sharply focused femtosecond laser beam and projection microscopy in a divergent electric field. The electric field is produced in vacuum between a metallic tip and a flat positionsensitive charged particle detector. The method enables investigation of photoionisation processes in low-density gases with a subdiffraction spatial resolution and can be used as well in profile measurements for sharply focused, intense laser beams. In a demonstration experiment, a femtosecond laser beam with a peak intensity of {approx}10{sup 14} W cm{sup -2} was focused to a 40-{mu}m-diameter waist in vacuum near a millimetre-size tip and {approx}2-{mu}m spatial resolution was achieved. According to our estimates, the use of a sharper tip will ensure a submicron spatial resolution, which is a crucial condition for the spatial diagnostics of sharply focused short-wavelength VUV radiation and X-rays. (extreme light fields and their applications)

74 ATOMIC AND MOLECULAR PHYSICS↗

The Survey of Lines in M31 (SLIM): The Drivers of the [C ii]/TIR Variation

The ratio of the [C ii] 158 μm emission line over the total infrared emission (TIR) is often used as a proxy for the photoelectric (PE) heating efficiency (ϵ{sub PE}) of the far-ultraviolet (FUV) photons absorbed by dust in the interstellar medium. In the nearby galaxy M31, we measure a strong radial variation of [C ii]/TIR that we rule out as being due to an intrinsic variation in ϵ{sub PE}. [C ii]/TIR fails as a proxy for ϵ{sub PE}, because the TIR measures all dust heating, not just the contribution from FUV photons capable of ejecting electrons from dust grains. Using extensive multi-wavelength coverage from the FUV to far-infrared, we infer the attenuated FUV emission (UV{sub att}), and the total attenuated flux (TOT{sub att}). We find [C ii]/TIR to be strongly correlated with UV{sub att}/TOT{sub att}, indicating that, in M31 at least, one of the dominant drivers for [C ii]/TIR variation is the relative hardness of the absorbed stellar radiation field. We define ϵ{sub PE}{sup UV}, [C ii]/UV{sub att} which should be more closely related to the actual PE efficiency, which we find to be essentially constant (1.85±0.8%) in all explored fields in M31. This suggests that part of the observed variation of [C ii]/TIR in other galaxies is likely due to a change in the relative hardness of the absorbed stellar radiation field, caused by a combination of variations in the stellar population, dust opacity, and galaxy metallicity, though PE efficiency may also vary across a wider range of environments.

79 ASTRONOMY AND ASTROPHYSICS↗

A two-color tunable infrared/vacuum ultraviolet spectrometer for high-resolution spectroscopy of molecules in molecular beams

We describe here the key technical elements of a two-color tunable IR/VUV photoionization TOF mass spectrometer system which allows a wide-range of high-resolution experiments to be performed on a diverse range of cold molecules and clusters in a molecular beam. In particular we highlight the methods we have applied to provide efficient wavelength separation of the VUV radiation from the longer wavelength components used to generate it and discuss a number of systems that we have studied with the instrument which highlight its flexibility for use in the study of molecular spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A FAR-ULTRAVIOLET ATLAS OF LOW-RESOLUTION HUBBLE SPACE TELESCOPE SPECTRA OF T TAURI STARS

We present a far-ultraviolet (FUV) spectral atlas consisting of spectra of 91 pre-main-sequence stars. Most stars in this sample were observed with the Space Telescope Imaging Spectrograph and Advanced Camera for Surveys on the Hubble Space Telescope (HST). A few archival spectra from the International Ultraviolet Explorer and the Goddard High Resolution Spectrograph on HST are included for completeness. We find strong correlations among the O I {lambda}1304 triplet, the Si IV {lambda}{lambda}1394/1403 doublet, the C IV {lambda}1549 doublet, and the He II {lambda}1640 line luminosities. For classical T Tauri stars (CTTSs), we also find strong correlations between these lines and the accretion luminosity, suggesting that these lines form in processes related to accretion. These FUV line fluxes and X-ray luminosity correlate loosely with large scatters. The FUV emission also correlates well with H{alpha}, H{beta}, and Ca II K line luminosities. These correlations between FUV and optical diagnostics can be used to obtain rough estimates of FUV line fluxes from optical observations. Molecular hydrogen (H{sub 2}) emission is generally present in the spectra of actively accreting CTTSs but not the weak-lined T Tauri stars that are not accreting. The presence of H{sub 2} emission in the spectrum of HD 98800 N suggests that the disk should be classified as actively accreting rather than a debris disk. We discuss the importance of FUV radiation, including the hydrogen Ly{alpha} line, on the photoevaporation of exoplanet atmospheres. We find that the Ca II/C IV flux ratios for more evolved stars are lower than those for less evolved accretors, indicating preferential depletion of refractory metals into dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗

Generation of Intense UV Radiation during High-Current Breakdown over a Ferrite Surface

The dynamics and emission characteristics of pulsed breakdown over a ferrite surface at a current amplitude of 270 kA and current rise time of 80 ns were studied experimentally. It is shown that the characteristic transverse size of the discharge region in visible radiation is ~3 mm, while that in vacuum UV (VUV) radiation is ~200 μm. The duration of the VUV pulse with an average power of ≈0.275 GW is about 80 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

rf plasma system as an atomic oxygen exposure facility

The materials of spacecraft external surfaces in low Earth orbit (LEO) are exposed to the various constituents of the space environment, including atomic oxygen (AO) and solar ultra violet (UV) radiation. Material degradation and erosion by LEO are simulated in ground laboratories using a variety of experimental facilities, each with their respective limitations. rf oxygen plasma is a simulation facility widely used for materials screening for LEO application. However, the complex plasma environment, which contains, in addition to the neutral oxygen atoms, excited species, electrons, and ions as well as vacuum ultraviolet (VUV) radiation, might lead to erroneous determination of materials reactivity with respect to LEO. This paper describes the development of a simple, low cost rf plasma system to produce a well-defined AO and VUV environment. The new system constrained the afterglow flow through two right-angle turns. The afterglow was characterized at three specific locations by (i) optical emission spectroscopy for assessment of electronically excited states, (ii) current measurements, and (iii) UV radiation measurements. Kapton registered samples were exposed at the three specific locations in the system and characterized by mass loss for etch rate evaluation, and atomic force microscopy for surface modification. It was found that there is a significant reduction in ionic species, excited species, and UV radiation as the afterglow advances through the right-angle turns. The reduction in charged particle flux is due to recombination within the afterglow as well as neutralization by colliding with the grounded metal chamber walls; similar decrease in UV radiation flux occurs through radiation absorption by the chamber walls. Finally, it is shown that the ground state AO is the dominant reactive specie of the plasma afterglow after passing through the two right-angle turns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for molecular hydrogen fluorescence near 100 km

The fluorescence of H2 in the Lyman band system, excited by solar extreme ultraviolet radiation, provides a means for the optical detection of H2 in the upper atmosphere. In particular, the Ly beta line of hydrogen is nearly degenerate with the (6,0) P1 transition, and absorption in this line produces fluorescence in the v-prime = 6 progression, principally at 1265, 1366, 1462 and 1608 A. Absorption by O2 rapidly attenuates the Ly beta from an overhead sun below 100 km and also significantly attenuates the fluorescent radiation. Far-ultraviolet dayglow spectra from 1130 to 1510 A obtained from an Aerobee rocket experiment on 11 December 1972 give an upper limit for any H2 emission which is a factor of 5 higher than expected according to recent hydrogen models.

Feldman, P. D.↗

NSLS-II storage ring insertion device and front-end commissioning and operation

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed. We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.

43 PARTICLE ACCELERATORS↗

The effects of plasma exposure and vacuum ultraviolet irradiation on photopatternable low-k dielectric materials

The effects of plasma exposure and vacuum-ultraviolet (VUV) irradiation on photopatternable low-k (PPLK) dielectric materials are investigated. In order to examine these effects, current-voltage measurements were made on PPLK materials before and after exposure to a variety of inert plasma-exposure conditions. In order to examine the effects of photon irradiation alone, PPLK samples were also exposed to monochromatic synchrotron radiation with 10 eV photon energy. It was found that plasma exposure causes significant degradation in electrical characteristics, resulting in increased leakage-currents and decreased breakdown voltage. X-ray photoelectron spectroscopy measurements also show appreciable carbon loss near the sample surface after plasma exposure. Conversely, VUV exposure was found to increase breakdown voltage and reduce leakage-current magnitudes.

36 MATERIALS SCIENCE↗

Influence of the chlorine concentration on the radiation efficiency of a XeCl exciplex lamp

The influence of the chlorine concentration on the radiation efficiency of coaxial exciplex lamps (excilamps) excited by a dielectric barrier discharge (DBD) in binary Xe-Cl{sub 2} mixtures at pressures of 240–250 Torr is investigated experimentally and theoretically. The experiments were carried out at Cl{sub 2} concentrations in the range of 0.01–1%. The DBD characteristics were calculated in the framework of a one-dimensional hydrodynamic model at Cl{sub 2} concentrations in the range of 0.1–5%. It is found that the radiation intensities of the emission bands of Xe*{sub 2}(172 nm) and XeCl* (308 nm) are comparable when the chlorine concentration in the mixture is in the range of 0.01–0.1%. In this case, in the mixture, the radiation intensity of the Xe*{sub 2} molecule rapidly decreases with increasing Cl{sub 2} concentration and, at a chlorine concentration of ≥0.2%, the radiation of the B → X band of XeCl* molecules with a peak at 308 nm dominates in the discharge radiation. The radiation efficiency of this band reaches its maximum value at chlorine concentrations in the range of 0.4–0.5%. The calculated efficiencies of DBD radiation exceed those obtained experimentally. This is due to limitations of the one-dimensional model, which assumes the discharge to be uniform in the transverse direction, whereas the actual excilamp discharge is highly inhomogeneous. The influence of the chlorine concentration on the properties of the DBD plasma in binary Xe-Cl{sub 2} mixtures is studied numerically. It is shown that an increase in the Cl{sub 2} concentration in the mixture leads to the attachment of electrons to chlorine atoms and a decrease in the electron density and discharge conductivity. As a result, the electric field and the voltage drop across the discharge gap increase, which, in turn, leads to an increase in the average electron energy and the probability of dissociation of Cl{sub 2} molecules and ionization of Xe atoms and Cl{sub 2} molecules. The total energy deposited in the discharge rises with increasing chlorine concentration due to an increase in the power spent on the heating of positive and negative ions. The power dissipated by electrons decreases with increasing chlorine concentration in the working mixture. Recommendations on the choice of the chlorine content in the mixture for reducing the intensity of VUV radiation of the second continuum of the Xe*{sub 2} excimer without a substantial decrease in the excilamp efficiency are formulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reflectance and substrate currents of dielectric layers under vacuum ultraviolet irradiation

The reflectance of low-k porous organosilicate glass (SiCOH) as a function of photon energy under synchrotron vacuum ultraviolet (VUV) radiation was measured using a nickel mesh reflectometer. The authors found that during VUV irradiation, the reflectance of SiCOH and the substrate current were inversely correlated. Thus, reflectance can be inferred from substrate current measurements and vice versa. The authors conclude that reflectance or substrate current measurements can determine the photon energies that are absorbed and, therefore, cause dielectric damage during processing. Thus, reducing the flux of deleterious photon energies in processing systems can minimize dielectric damage.

36 MATERIALS SCIENCE↗

VUV action spectroscopy of protonated leucine-enkephalin peptide in the 6-14 eV range

We have studied the Vacuum Ultraviolet (VUV) photodissociation of gas-phase protonated leucine-enkephalin peptide ion in the 5.7 to 14 eV photon energy range by coupling a linear quadrupole ion trap with a synchrotron radiation source. We report VUV activation tandem mass spectra at 6.7, 8.4, and 12.8 eV photon energies and photodissociation yields for a number of selected fragments. The obtained results provide insight into both near VUV radiation damage and electronic properties of a model peptide. We could distinguish several absorption bands and assign them to particular electronic transitions, according to previous theoretical studies. The photodissociation yields appear to be very different for the various observed fragmentation channels, depending on both the types of fragments and their position along the peptide backbone. The present results are discussed in light of recent gas-phase spectroscopic data on peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bandgap measurements of low-k porous organosilicate dielectrics using vacuum ultraviolet irradiation

Vacuum ultraviolet (VUV) photoemission spectroscopy is used to investigate the effect of VUV radiation on porous organosilicate (SiCOH) dielectrics during plasma processing. By comparing photoemission spectroscopic results before and after VUV exposure, VUV irradiation with photon energies less than 9.0 eV was found to be beneficial in depleting accumulated charge in SiCOH films while VUV photons with higher energies did not have this effect. Moreover, VUV irradiation with 8.9 eV photons depletes the most charge. From this result, it can be concluded that 8.9 eV is the bandgap plus the electron affinity energy of SiCOH dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Luminescence of Pr{sup 3+} Impurity Centers and Defects in Sr{sub 9}Sc (PO{sub 4}){sub 7}:Pr{sup 3+}

The spectroscopic characteristics and luminescence decay kinetics of Sr{sub 9}Sc(PO{sub 4}){sub 7}:Pr{sup 3+}(1%) were investigated using synchrotron radiation of ultraviolet (UV), vacuum ultraviolet (VUV) and X-ray ranges, as well as pulsed cathodoluminescence (PCL) methods at temperatures of 10, 90, and 295 K. The luminescence spectra contain three groups of bands and lines. In the UV range, the observed bands correspond to interconfigurational 5d → 4f transitions in Pr{sup 3+} ions. In the visible spectrum, the wide luminescence band of defects dominates, as well as narrow lines associated with intraconfigurational 4f → 4f transitions in Pr{sup 3+} ions. When excited by an electron beam (5 Hz), the main component with a decay time τ ∼ 17 ns dominates in the decay kinetics of the 5d → 4f luminescence. The decay kinetics of 5d → 4f luminescence upon excitation with high-frequency (τ ∼ 8 MHz) synchrotron radiation of the X-ray range contains a fast component (τ ∼ 15 ns) against the background of the slow component of the μs-range. An effective nonradiative energy transfer is observed from impurity centers to defects, as well as from the host to Pr{sup 3+} ions and defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of surface vacuum ultraviolet emissions with resonance level number densities. I. Argon plasmas

Vacuum ultraviolet (VUV) photons emitted from excited atomic states are ubiquitous in material processing plasmas. The highly energetic photons can induce surface damage by driving surface reactions, disordering surface regions, and affecting bonds in the bulk material. In argon plasmas, the VUV emissions are due to the decay of the 1s{sub 4} and 1s{sub 2} principal resonance levels with emission wavelengths of 104.8 and 106.7 nm, respectively. The authors have measured the number densities of atoms in the two resonance levels using both white light optical absorption spectroscopy and radiation-trapping induced changes in the 3p{sup 5}4p→3p{sup 5}4s branching fractions measured via visible/near-infrared optical emission spectroscopy in an argon inductively coupled plasma as a function of both pressure and power. An emission model that takes into account radiation trapping was used to calculate the VUV emission rate. The model results were compared to experimental measurements made with a National Institute of Standards and Technology-calibrated VUV photodiode. The photodiode and model results are in generally good accord and reveal a strong dependence on the neutral gas temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of space instruments at the Metrology Light Source

PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angle-resolved photoemission spectroscopy with 9-eV photon-energy pulses generated in a gas-filled hollow-core photonic crystal fiber

A recently developed source of ultraviolet radiation, based on optical soliton propagation in a gas-filled hollow-core photonic crystal fiber, is applied here to angle-resolved photoemission spectroscopy (ARPES). Near-infrared femtosecond pulses of only few μJ energy generate vacuum ultraviolet radiation between 5.5 and 9 eV inside the gas-filled fiber. These pulses are used to measure the band structure of the topological insulator Bi{sub 2}Se{sub 3} with a signal to noise ratio comparable to that obtained with high order harmonics from a gas jet. The two-order-of-magnitude gain in efficiency promises time-resolved ARPES measurements at repetition rates of hundreds of kHz or even MHz, with photon energies that cover the first Brillouin zone of most materials.