Application of OMI, SCIAMACHY and GOME-2 Satellite SO2 Retrievals for Detection of Large Emission Sources

Retrievals of sulfur dioxide (SO2) from space-based spectrometers are in a relatively early stage of development. Factors such as interference between ozone and SO2 in the retrieval algorithms often lead to errors in the retrieved values. Measurements from the Ozone Monitoring Instrument (OMI), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), and Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensors, averaged over a period of several years, were used to identify locations with elevated SO2 values and estimate their emission levels. About 30 such locations, detectable by all three sensors and linked to volcanic and anthropogenic sources, were found after applying low and high spatial frequency filtration designed to reduce noise and bias and to enhance weak signals to SO2 data from each instrument. Quantitatively, the mean amount of SO2 in the vicinity of the sources, estimated from the three instruments, is in general agreement. However, its better spatial resolution makes it possible for OMI to detect smaller sources and with additional detail as compared to the other two instruments. Over some regions of China, SCIAMACHY and GOME-2 data show mean SO2 values that are almost 1.5 times higher than those from OMI, but the suggested spatial filtration technique largely reconciles these differences.

SO2 retrievals↗

Methods for Purifying Enzymes for Mycoremediation

A process for purifying laccase from an ectomycorrhizal fruiting body is disclosed. The process includes steps of homogenization, sonication, centrifugation, filtration, affinity chromatography, ion exchange chromatography, and gel filtration. Purified laccase can also be separated into isomers.

Cullings, Kenneth W.↗

The Role of Planetary Dust and Regolith Mechanics in Technology Developments at NASA

One of NASA's long term goals continues to be the exploration of other planets and orbital bodies in our solar system. Our sustained presence through the installation of stations or bases on these planetary surfaces will depend on developing properly designed habitation modules, mobility systems and supporting infrastructure. NASA Glenn Research Center is involved in several technology developments in support of this overarching goal. Two key developments are in the area of advanced filtration and excavation systems. The first addresses the issues posed by the accumulation of particulate matter over long duration missions and the intrusion of planetary dust into spacecraft and habitat pressurized cabins. The latter supports the operation and infrastructure of insitu resource utilization (ISRU) processes to derive consumables and construction materials from the planetary regolith. These two developments require a basic understanding of the lunar regolith at the micro (particle) to macro (bulk) level. Investigation of the relevant properties of the lunar regolith and characterization of the standard simulant materials used in. testing were important first steps in these developments. The fundamentals and operational concepts of these technologies as well as descriptions of new NASA facilities, including the Particulate Filtration Testing and the NASA Excavation and Traction Testing facilities, and their capabilities for testing and advancing these technologies will be presented. The test data also serves to validate and anchor computational simulation models.

Agui, Juan H.↗

System and Apparatus for Filtering Particles

A modular pre-filtration apparatus may be beneficial to extend the life of a filter. The apparatus may include an impactor that can collect a first set of particles in the air, and a scroll filter that can collect a second set of particles in the air. A filter may follow the pre-filtration apparatus, thus causing the life of the filter to be increased.

Agui, Juan H.↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

System and Apparatus for Filtering Particles

A modular pre-filtration apparatus may be beneficial to extend the life of a filter. The apparatus may include an impactor that can collect a first set of particles in the air, and a scroll filter that can collect a second set of particles in the air. A filter may follow the pre-filtration apparatus, thus causing the life of the filter to be increased.

Agui, Juan H.↗

Precision Assessment of the HPLC Phytoplankton Pigment Dataset Analyzed by NASA to Quantify Global Variability in Support of Ocean Color Remote Sensing

The ability to generate chlorophyll a (Chl a) assessments from ocean color orbital sensors, such as VIIRS and MODIS, that satisfy the requirements to be climate-quality data record (CDR) quality is contingent in part on the quality of the in situ ground or sea truth observations that serve as datasets for vicarious calibration and algorithm validation activities. NASA has a mandate to collect, analyze, and distribute in situ data of the highest possible quality with documented uncertainties and in keeping with established performance metrics. Using a dataset of over 18,000 HPLC phytoplankton pigment samples representing water collected in all major ocean basins analyzed a central laboratory (Field Support Group (FSG) of the Ocean Ecology Laboratory (OEL) at NASA Goddard Space Flight Center (GSFC)), we performed an assessment of the global precision among sample replicates of Chl a as well as major accessory pigments. We investigated the impacts of filtration volume, water basin, collection technique, pigment concentration, and different filtration volumes for replicate filters on replicate filter precision, as well as investigating any pigment-specific differences. Our results quantify sample variability with the goal of understanding any systemic biases or biogeographic influences.

Thomas, Crystal S.↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar dust simulant and at high rates of particle loading. The pressure drop across the filter media was measured as a function of accumulated particle mass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media.

Sub-ambient↗

ISS Wastewater Pretreatment via DNA Pattern Picofilter Using Inorganic Brine Stimulant

Astronauts in the International Space Station (ISS) need as much water as they can access, whether it comes from people's breath, sweat or urine, recycled shower water or hand washing. It is of vital importance that any type of water is recycled and filtrated through different methods so it can be re-used. Recently, Cerahelix Inc. offered a ceramic tubular membrane element that uses DNA strands as a pattern in a sol-gel process that allows the sintered product to have a pore size in the picometer scale and claims to achieve ten times higher purity than other commercially available ceramic filters. This should allow higher purities and yields at reduced energy costs and theoretically allow near total dewatering of the reject stream and greater than 80% removal of polyvalent ions. Trials were performed with Cerahelix Inc. filters using an inorganic brine simulant at two pHs to test the efficiency of Pico Helix TM membranes and determine their feasibility for spacecraft wastewater treatment processes. Emphasis was placed on the polyvalent ions: SO42-, PO43-, Mg2+, and Ca2+. These ions should be rejected almost entirely from the feed solution and, not permeate through the filter. Results show that at a pH of 4.2, permeation of the polyvalent ions varied from 59% to 74% and at pH of 8.0, permeation varied from 72% to 87%. An Extended Nernst Planck (ENP) approach that describes the mass transfer process for a pico-filtration membrane was used to construct a model to inform the experimental expectations and outcome.

Carolina Franco↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar he filter media was measured as a function of accumulated particle mdust simulant and at high rates of particle loading. The pressure drop across tass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media

Sub-ambient↗

Flight Environment HEPA Filter Testing for Lunar Dust Removal Capability

Lunar dust is an abrasive regolith that can cause critical damage to hardware and crew. Its morphology and chemical makeup differs from typical earth dust due to space weathering effects. Current space missions require extensive air filtration of lunar dust to ensure mission success; as such filtration testing is paramount in verifying the dust-removal capabilities of the system. Previous testing at NASA GRC consisted of two stages: testing a flat high efficiency particulate air (HEPA) media sheet at various pressure ranges (Stage 1) and testing a pleated HEPA filter at different humidity and dust levels (Stage 2). This testing was done to buy-down risk when testing the flight-qualification HEPA filter for the proposed Stage 3 test. Stage 3 testing used a flight-ready HEPA filter to measure its performance characteristics to verify programmatic requirements. This included measuring lunar dust loading versus pressure drop performance and establishing a maximum capacity based on the allowable pressure drop, determining the HEPA filter efficiency utilizing two separate methodologies, and assessing if the lunar dust caused the HEPA filter to experience any damage. Additionally, dust removal from the HEPA filter was performed using a vacuum to ascertain if the filter life can be prolonged. These test results will aid the program in verifying programmatic requirements and ensuring risk buydown before this HEPA filter takes flight.

HEPA↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Evaluation of the Accumulation of Foreign Object Debris in the International Space Station Ventilation Systems and Resulting Impacts to Systems

A challenge for the International Space Station (ISS) is accumulation of Foreign Object Debris (FOD) and the impacts to crew, equipment, and experiments. One function of the temperature and humidity control system is to capture FOD with various methods of filtration to minimize these impacts. ISS filtration has been augmented by charcoal filters and screens. A qualitative comparison of the quantity of FOD found over the years and the current levels are evaluated. Impacts to FOD are crew time for cleaning, reduction of equipment life, and component damage and examples are provided. Recommendations for further improvements to reduce the accumulation of FOD on ISS is provided.

ISS↗

Evaluation of the Accumulation of Foreign Object Debris in the International Space Station Ventilation Systems and Resulting Impacts to Systems

A challenge for the International Space Station (ISS) is accumulation of foreign object debris (FOD) in the ventilation systems and the impacts to crew, equipment, and experiments. One function of the temperature and humidity control system is to capture FOD with various methods of filtration to minimize these impacts. ISS filtration has been augmented by charcoal and High Efficiency Particulate Air (HEPA) filters and screens. A qualitative comparison of the quantity of FOD found since 2012 study and the current levels are evaluated. Impacts due to FOD are reduced air circulation, increased crew time for cleaning, reduction of equipment life, and component damage; examples are provided. Recommendations for further improvements to reduce the accumulation of FOD on ISS are provided.

ISS↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗