Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLAG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

FermI large area telescope third source catalog

We present the third Fermi Large Area Telescope (LAT) source catalog (3FGL) of sources in the 100 MeV–300 GeV range. Based on the first 4 yr of science data from the Fermi Gamma-ray Space Telescope mission, it is the deepest yet in this energy range. Relative to the Second Fermi LAT catalog, the 3FGL catalog incorporates twice as much data, as well as a number of analysis improvements, including improved calibrations at the event reconstruction level, an updated model for Galactic diffuse γ-ray emission, a refined procedure for source detection, and improved methods for associating LAT sources with potential counterparts at other wavelengths. The 3FGL catalog includes 3033 sources above 4σ significance, with source location regions, spectral properties, and monthly light curves for each. Of these, 78 are flagged as potentially being due to imperfections in the model for Galactic diffuse emission. Twenty-five sources are modeled explicitly as spatially extended, and overall 238 sources are considered as identified based on angular extent or correlated variability (periodic or otherwise) observed at other wavelengths. For 1010 sources we have not found plausible counterparts at other wavelengths. More than 1100 of the identified or associated sources are active galaxies of the blazar class; several other classes of non-blazar active galaxies are also represented in the 3FGL. Pulsars represent the largest Galactic source class. From source counts of Galactic sources we estimate that the contribution of unresolved sources to the Galactic diffuse emission is ∼3% at 1 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

The impact of spectroscopic incompleteness in direct calibration of redshift distributions for weak lensing surveys

ABSTRACT Obtaining accurate distributions of galaxy redshifts is a critical aspect of weak lensing cosmology experiments. One of the methods used to estimate and validate redshift distributions is to apply weights to a spectroscopic sample, so that their weighted photometry distribution matches the target sample. In this work, we estimate the selection bias in redshift that is introduced in this procedure. We do so by simulating the process of assembling a spectroscopic sample (including observer-assigned confidence flags) and highlight the impacts of spectroscopic target selection and redshift failures. We use the first year (Y1) weak lensing analysis in Dark Energy Survey (DES) as an example data set but the implications generalize to all similar weak lensing surveys. We find that using colour cuts that are not available to the weak lensing galaxies can introduce biases of up to Δz ∼ 0.04 in the weighted mean redshift of different redshift intervals (Δz ∼ 0.015 in the case most relevant to DES). To assess the impact of incompleteness in spectroscopic samples, we select only objects with high observer-defined confidence flags and compare the weighted mean redshift with the true mean. We find that the mean redshift of the DES Y1 weak lensing sample is typically biased at the Δz = 0.005−0.05 level after the weighting is applied. The bias we uncover can have either sign, depending on the samples and redshift interval considered. For the highest redshift bin, the bias is larger than the uncertainties in the other DES Y1 redshift calibration methods, justifying the decision of not using this method for the redshift estimations. We discuss several methods to mitigate this bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Biological consequences of MLC calibration errors in IMRT delivery and QA

Purpose: The purpose of this work is threefold: (1) to explore biological consequences of the multileaf collimator (MLC) calibration errors in intensity modulated radiotherapy (IMRT) of prostate and head and neck cancers, (2) to determine levels of planning target volume (PTV) and normal tissue under- or overdose flagged with clinically used QA action limits, and (3) to provide biologically based input for MLC QA and IMRT QA action limits. Methods: Ten consecutive prostate IMRT cases and ten consecutive head and neck IMRT cases were used. Systematic MLC offsets (i.e., calibration error) were introduced for each control point of the plan separately for X1 and X2 leaf banks. Offsets were from - 2 to 2 mm with a 0.5 mm increment. The modified files were imported into the planning system for forward dose recalculation. The original plan served as the reference. The generalized equivalent uniform dose (gEUD) was used as the biological index for the targets, rectum, parotid glands, brainstem, and spinal cord. Each plan was recalculated on a CT scan of a 27 cm diameter cylindrical phantom with a contoured 0.6 cc ion chamber. Dose to ion chamber and 3D gamma analysis were compared to the reference plan. QA pass criteria: (1) at least 95% of voxels with a dose cutoff of 50% of maximum dose have to pass at 3 mm/3% and (2) dose to chamber within 2% of the reference dose. Results: For prostate cases, differences in PTV and rectum gEUD greater than 2% were identified. However, a larger proportion of plans leading to greater than 2% difference in prostate PTV gEUD passed the ion chamber QA but not 3D gamma QA. A similar trend was found for the rectum gEUD. For head and neck IMRT, the QA pass criteria flagged plans leading to greater than 4% differences in PTV gEUD and greater than 5% differences in the maximum dose to brainstem. If pass criteria were relaxed to 90% for gamma and 3% for ion chamber QA, plans leading to a 5% difference in PTV gEUD and a 5%-8% difference in brainstem maximum dose would likely pass IMRT QA. A larger proportion of head and neck plans with greater than 2% PTV gEUD difference passed 3D gamma QA compared to ion chamber QA. Conclusions: For low modulation plans, there is a better chance to catch MLC calibration errors with 3D gamma QA rather than ion chamber QA. Conversely, for high modulation plans, there is a better chance to catch MLC calibration errors with ion chamber QA rather than with 3D gamma QA. Ion chamber and 3D gamma analysis IMRT QA can detect greater than 2% change in gEUD for PTVs and critical structures for low modulation treatment plans. For high modulation treatment plans, ion chamber and 3D gamma analysis can detect greater than 2% change in gEUD for PTVs and a 5% change in critical structure gEUD since either QA methods passes the QA criteria. For gEUD changes less than those listed above, either QA method has the same proportion of passing rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

60 APPLIED LIFE SCIENCES↗

GenConfig

SAND2025-04091O GenConfig converts a build name into a set of configuration flags or CMake fragment files for use with CMake. This is accomplished using ConfigKeywordParser and two configuration files. GenConfig is the main tool in a set of software libraries used for generating and configuring an environment and configuration flags. The tool uses other modules within the GenConfig family to ultimately parse and enable an environment that is ready for development from a given build name string. The unique algorithms used in GenConfig mainly pertain to validating the format and checking the existence of the given build string in the expected configuration .ini files. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Gates, Jason↗

ARM Climate Modeling Best Estimate Data - A new data product for climate modelers

This paper provides an overview of a new data product, named the Climate Modeling Best Estimate (CMBE) dataset, developed by the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Program in order to better serve the need of climate model developers and encourage greater use of ARM data by modelers. The CMBE dataset contains those quantities that are often used in model evaluation and reflect unique ARM measurements of clouds and radiation (e.g., cloud occurrence, liquid water path, and surface radiative fluxes) from the highest quality data that ARM has for many years. The data are averaged over one hour period, which is comparable to a typical temporal resolution used in climate model output. They are currently available at five ARM Climate Research Facility (ACRF) sites located at the Southern Great Plains, North Slope of Alaska, and Tropic Western Pacific, and can be obtained from the ACRF data archive. The long-term continuous ARM data provide invaluable information to improve our understanding of the interaction between clouds and radiation and a solid observational basis for model validation and improvement. This paper shows some examples to demonstrate its unique values in studies of cloud processes, climate variability and change, and climate modeling. Plans for future enhancements of the CMBE product are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Streamflow measurements from four sites on the Tuolumne River in Yosemite National Park from Water Years 2002 to 2021

Regions with remote and complex terrain experience spatially varying streamflow patterns, but are often poorly sampled due to difficult access. This data package includes streamflow measurements collected using low-visibility and low-impact installations at four sites on the Tuolumne River in Yosemite National Park, for water years 2002 to 2021. The resulting data set offers a unique opportunity to explore hydrologic processes in complex terrain.This data package contains half-hourly recordings of unvented pressure, vented pressure, and water temperature are measured and used to estimate discharge and stage height. Discharge flags provide insight into data anomalies. This dataset is formatted in accordance with ESS-Dive's Hydrologic Monitoring and File Level Metadata Formats. It contains the following files:1) Folder containing four csv files of time series streamflow measurements (unvented pressure, vented pressure, estimated discharge, water temperature, stage height, and discharge flag) from four locations on the Tuolumne River2) Data dictionary (dd.csv) containing units, definitions, human readable column names, and data type for all column headers throughout the dataset3) File-level metadata (FLMD.csv) containing metadata for files contained in the dataset4) Installation methods (InstallationMethods.csv) containing metadata on sensor installation

54 ENVIRONMENTAL SCIENCES↗

Continuous snow depth and temperature measurements from dense network of above-ground distributed temperature profiling systems from 2021-09-23 to 2024-08-23, Seward Peninsula, Alaska

The dataset contains temperature measurements from distributed temperature profiling (DTP) systems (Dafflon et al., 2022; Wielandt et al., 2022; Wang et al., 2024a; Fiolleau et al., 2024) deployed vertically above the ground surface at a large number of locations from 2021 to 2024. The research is designed to improve understanding of the local heterogeneity in snow depth and snow thermal insulation dynamics, as well as their interactions in a discontinuous permafrost region (Wang et al., 2025). The DTP systems were deployed at 96 locations in a watershed along the Nome-Teller road at mile marker 27 (T27) and at 54 locations on a hillslope along the Kougarok road at mile marker 64 (K64) in the Seward Peninsula, Alaska. The probe location information is stored in Probe_locations_T27.csv and Probe_locations_K64.csv. Temperature measurements were recorded at 15-minute intervals using high-precision digital sensors (accuracy: ±0.1°C, resolution: 0.0078°C). The temperature probes, either 1.4 m or 1.6 m long, contain sensors spaced every 5 cm or 10 cm along their length. The temperature data are stored in compressed files following the format: DTP_snow_air_temperature_(site)_(start)_(end).zip, where site is either T27 or K64, and start and end represent the time series period. Within each ZIP file, individual CSV files are named by probe ID and contain temperature records at different heights above the ground surface.This dataset also includes derived snow depth time series over three snow seasons, estimated from temperature measurements. Snow depth was estimated by identifying the consecutive sensor pair that exhibited the largest drop in high-frequency temperature fluctuations (detailed in the methods). These data are stored in: Snow_depths_flags_(site)_(start)_(end).csv, which includes snow depth time series and corresponding quality flags (defined in the methods) from different probes. Additionally, the dataset includes derived metrics and supporting measurements at selected locations over two snow seasons, contributing to the manuscript of Wang et al., 2025. These locations were chosen based on the availability of high-quality snow depth time series during both seasons. The additional data include: (1) Air temperature proxies measured from the top sensors on the pole when they were not buried by snow, stored in Air_temperature_proxies_(site)_(start)_(end).csv (2) Ground interface temperature, recorded at 3 cm above the ground, stored in Ground_interface_temperature_(site)_(start)_(end).csv (3) Site characteristics, including vegetation height, elevation, and the topographic position index (TPI) within a 50 m radius, stored in Selected_probe_locations_gps_vegheight_tpi_elevation_(site).csv. These metrics were derived from 1 m resolution summer LiDAR-based digital elevation models and digital surface models from Singhania et al., 2023, DOI:10.5440/1832016. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv.This dataset is an updated version of a previous archive (Wang et al., 2024b, DOI: 10.15485/2475020), incorporating multiple seasons and improved snow depth estimation. Please note that due to large amount of information present in this dataset, many specificities associated with the acquisition of snow temperature, air temperature proxy and estimation of snow depth, and the future archiving of additional datasets on the soil temperature, thaw depth and soil characteristics at these locations, the author would welcome being contacted by people planning to use this dataset.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Stream Chemistry, Synoptic Surveys, East Fork Poplar Creek Watershed, TN, USA; April 2023 to February 2025

Impacts of developed land cover on stream chemistry can be difficult to discern from natural variability, particularly in carbonate watersheds where weathering of urban infrastructure and lithology generate similar signatures. We evaluated how spatial patterns of stream chemistry varied across perennial and non-perennial tributaries spanning an urban-to-forested gradient in a mid-order, carbonate-dominated watershed. This data package contains a processed and compiled summary of stream chemistry and properties obtained from 12 synoptic surveys of 54 stream sites across the East Fork Poplar Creek watershed located near Oak Ridge, TN, United States. The sites include non-perennial tributaries, perennial tributaries, and the main stem and span forested to urban (highly developed) land cover gradients. The data package includes the processed and flagged chemical data (WaDE_SynopticSummary_FinalChemistry), metadata describing data flagging and analysis (WaDE_SynopticSummary_Metadata), information about each site and its contributing subcatchment (WaDE_SynopticSummary_SiteInformation), and a comparison of instrument and field detection limits used to determine method detection limits for the study (WaDE_SynopticSummary_DetectionLimitComparison). Stream chemistry includes stream parameters measured in situ using multiparameter probes (dissolved oxygen, pH, specific conductance, temperature) and solutes including nutrients (nitrate, ammonium, soluble reactive phosphorus), dissolved organic carbon, dissolved inorganic carbon, major cations (calcium, magnesium, potassium, sodium), major anions (chloride, sulfate), and a broad suite of minor and trace elements.

EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > SURFACE ↗

Changes to MFRSRCLDOD1MIN Datastream

Significant updates were made to the multifilter rotating shadowband radiometer (MFRSR) cloud optical depth (MFRSRCLDOD) value-added product (VAP) in 2011. The original intent of the update was to add quality control (QC) flags and to update the VAP to use the improved retrievals of liquid water path (LWP) from the Microwave Radiometer Retrievals (MWRRET) VAP rather than the statistical retrievals of LWP from the Microwave Radiometer Line of Sight (MWRLOS) datastream. Although this was originally intended to be a straightforward update of the code, it became more complicated due to the following factors: (1) a new developer and translator team were working with the code; (2) numerous small changes had to be made to the code to consistently implement the QC flags; and (3) ARM standards have changed over the years since the code was originally developed.

99 GENERAL AND MISCELLANEOUS↗

The Sedov Test Problem [Slides]

The Sedov test is classically defined as a point blast problem. The Sedov problem has led us to advances in algorithms and in their understanding. Vorticity generation can be physical or numerical. Both play a role in Sedov calculations. The RAGE code (Eulerian) resolves the shock well, but produces vorticity. The source definition matters. For the FLAG code (Lagrange), CCH is superior to SGH by avoiding spurious vorticity generation. FLAG SGH currently has a number of options that improve results over traditional settings. Vorticity production, not shock capture, has driven the Sedov work. We are pursuing treatments with respect to the hydro discretization as well as to artificial viscosity.

97 MATHEMATICS AND COMPUTING↗

EOSPAC User's Manual (V.6.2)

The EOSPAC utility package is a collection of interface routines, which can be used to access the SESAME data library and perform various data adjustments and interpolations on the SESAME data. The SESAME data library contains both thermodynamic (e.g., equation of state) and transport coefficients (e.g., opacity and conductivity), and it is described in reference 1. Note, for simplicity, the term EOS (equation of state) used herein includes both thermodynamic variables and transport coefficients. The EOSPAC utility package is designed to be used by physics codes (henceforth 'host codes') written in multiple languages and on multiple platforms. The remainder of this manual is organized into several sections. Section 2 provides a general overview of basic theory and models implemented within EOSPAC. Section 3 provides a general overview of how to use the EOSPAC interface library. Section 4 discusses conventions such as data organization and routine names. Sections 5 through 7 describe the public interfaces of EOSPAC in detail. Section 8 provides details related to some selected numerical features of EOSPAC. Section 9 gives examples for using the interface routines described in sections 5 through 7. Section 10 provides technical support contact information. Section 11 contains a brief set of acknowledgments. Finally, section 12 contains a list of referenced documents. Appendices list the Table Type Definitions, the Option Flag Definitions, the Information Flag Definitions, and the Error Code Definitions.

99 GENERAL AND MISCELLANEOUS↗

Smart Infrared Inspection System Field Operational Test (Final Report)

The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

brake system↗

Droplet Number Concentration Value-Added Product

The ndrop_mfrsr value-added product (VAP) provides an estimate of the cloud droplet number concentration of overcast water clouds retrieved from cloud optical depth from the multi-filter rotating shadowband radiometer (MFRSR) instrument and liquid water path (LWP) retrieved from the microwave radiometer (MWR). When cloud layer information is available from vertically pointing lidar and radars in the Active Remote Sensing of Clouds (ARSCL) product, the VAP also provides estimates of the adiabatic LWP and an adiabatic parameter (beta) that indicates how divergent the LWP is from the adiabatic case. quality control (QC) flags (qc_drop_number_conc), an uncertainty estimate (drop_number_conc_toterr), and a cloud layer type flag (cloud_base_type) are useful indicators of the quality and accuracy of any given value of the retrieval. Examples of these major input and output variables are given in sample plots in section 6.0.

97 MATHEMATICS AND COMPUTING↗

Advanced SAPHIRE 8 Modeling Methods for Probabilistic Risk Assessment via the Systems Analysis Program for Hands-On Integrated Reliability Evaluations (SAPHIRE) Software P-202

1.1. Overview of the Advanced SAPHIRE Material The Advanced SAPHIRE course material is intended to both (1) provide guidance for learning advanced SAPHIRE features during the class and (2) become a stand-alone reference document after finishing the class. Thus, the format for the class material is a combination of the traditional “overhead-type” of presentation information with a structured, reference-type document. Major topics that are covered in the Advanced SAPHIRE class include: Advanced data base concepts such as Model Type (e.g., random, seismic, fire, flood). Definition of house events and how they are used on a sequence-by-sequence basis to manipulate individual fault tree logic using sequence flag sets or fault tree flag sets. ? Basic event templates, compound basic event equation editors, and human error worksheets. A rule-based event tree top event substitution feature (called the Link Event Tree Rule Editor) which allows for top event substitutions. A rule-based cut set post-processing feature (called the Recovery Rules) which allows cut set manipulation. Cut set analysis based upon rule-based end state categories (called End State Analysis). Cut set generation options for both fault trees and event tree sequences. The large event tree methodology and how SAPHIRE can be used to generate sequence cut sets for this method. The transfer of data between SAPHIRE data bases and between other PRA codes (MAR-D).

97 MATHEMATICS AND COMPUTING↗

UNR ETI Computational Investigation (Year 2)

The LANL ASC Arbitrary Lagrange/Eulerian (ALE) code, FLAG, is being used to model experiments conducted under this grant in order to understand the physics limiting high-current conduction and thermal plasma production. This includes the effects of nonlinear magnetic diffusion (NLMD), the magnetic Rayleigh-Taylor (MRT) instability, and the electro-thermal instability (ETI). FLAG is a multi-dimensional, unstructured-grid, multi-material, multi-temperature, shockphysics code with a single-fluid, resistive magnetohydrodynamics (MHD) package. Equations-ofstate (EOS), conductivity, material-strength, and melt can be treated with a variety of analytic or tabular models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion Detection LDRD Seedling (Final Report)

Automation techniques for recognizing material defects are very common in fields like infrastructure survey and civil engineering; however, the defects are usually easily distinguishable from their background, on a larger scale (e.g. cement bridges), and very specific. Extracting information about a defect that is near or equal to the background of the data can be extremely difficult. Images with heavy background corrosion, pitting, cracking, and man-made defects (such as welding) makes extracting information on a specific defect near-impossible. This is especially true when the defect is on the micron level and the dynamic range of your image taking instrument is low. So, a simplified, Java-based Fiji™ (ImageJ) defect detection program, dependent on a ‘flag’ system, was proposed for data that has a micron level hairline crack that is near or equal to the background. The utilization of the built-in functions, plugins, and macro scripting capability of the Java-based software sends a series of flags to the user that help to identify if the surface contains a defect of interest and to characterize that defect.

42 ENGINEERING↗