Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Technical Report on Subsurface Monitoring of the Brady Hot Spring Geothermal Site, Nevada, based upon Full Waveform Inversion

Abilities to accurately characterize the subsurface in a geothermal setting is key to assess and support production. An important element of geothermal reservoir monitoring is also the ability to investigate fluid transport within fracture network. This report focuses on improving subsurface imaging and monitoring in geothermal settings using full waveform inversion based on the adjoint method and time-lapse imaging. To assess our method, we rely on a dense seismic dataset collected in 2016 at the Brady Hot Springs geothermal site in Nevada for the DOE-funded project Poroelastic Tomography by Adjoint Inverse Modeling of Data from Seismology, Geodesy, and Hydrology. This dataset captures subsurface changes across four stages of geothermal power plant operations, which involve varying rates of fluid injection and extraction. Two velocity models were previously derived from this dataset using different methods: one based on travel times and another on sweep interferometry. Our first step is to refine these models using adjoint tomography, which has been applied successfully at global and regional-scales but is less common at the reservoir-scale. Two approaches are then explored for time-lapse analysis: directly comparing refined tomographic models from different stages or backpropagating waveform differences relative to a baseline tomographic model. The main take away is that both approaches highlight similar reservoir behaviors, but the latter approach is more computationally effective in capturing small-scale changes in subsurface properties. For this work, we leverage the use of Salvus (www.mondaic.com), an end-to-end seismic imaging solution, relying on the spectral element method to compute forward and adjoint simulations, and developed by Mondaic Ltd. It includes integrated workflow management that handles waveform and metadata, launches simulations, computes waveform misfits and adjoint sources, and iterates for model updates by nonlinear optimization.

15 GEOTHERMAL ENERGY↗

Abrasion wear at high temperature in particle receiver type Concentrating Solar Power Systems

The use of solid particles as a heat transfer fluid in receivers for concentrating solar powerplants has garnered much attention in the past decade. Particles are not only stable at temperatures above 700 °C but are also able to absorb solar energy directly, which gives them a distinct advantage over conventional molten salts. The use of particles can, however, cause material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. Stainless steel alloy 316, nickel-based alloy Inconel® 740H®, Haynes 230, and a 60% alumina, low-cement refractory castable from Allied Mineral Products were tested for wear from first-of-a-kind high-temperature low-velocity abrasion-erosion experiments. The tests are designed to simulate potential conditions in Generation 3 falling particle Concentrating Solar Power (CSP) systems. Simultaneous experiments were conducted at room temperature as well to draw comparison on the role of temperature on abrasion wear rates. It was noted that the abrasion wear rate in candidate materials was driven by the oxidation resistance of the material. The findings from these experiments will be used to determine life-time of critical components in particle receiver concentrated solar powerplants.

14 SOLAR ENERGY↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Cooperation in a fluid swarm of fuel-free micro-swimmers

Abstract While motile bacteria display rich dynamics in dense colonies, the phoretic nature of artificial micro-swimmers restricts their activity when crowded. Here we introduce a new class of synthetic micro-swimmers that are driven solely by light. By coupling a light absorbing particle to a fluid droplet we produce a colloidal chimera that transforms optical power into propulsive thermo-capillary action. The swimmers’ internal drive allows them to operate for a long duration (days) and remain active when crowded, forming a high density fluid phase. We find that above a critical concentration, swimmers form a long lived crowded state that displays internal dynamics. When passive particles are introduced, the dense swimmer phase can re-arrange to spontaneously corral the passive particles. We derive a geometrical, depletion-like condition for corralling by identifying the role the passive particles play in controlling the effective concentration of the micro-swimmers.

59 BASIC BIOLOGICAL SCIENCES↗

A review of computational methods for studying oscillating water columns – the Navier-Stokes based equation approach

This review evaluates the state-of-the-practice numerical tools used to predict the performance of Oscillating Water Column (OWC). The OWC is a widely studied Wave Energy Converter that provides a reliable form of renewable form of electricity that can potentially meet global energy needs. However, the fluid-flow phenomena affecting its hydrodynamic performance are not fully understood. While there has been the successful full-scale deployment of OWCs, various computational methods are being explored to optimize this technology. Potential flow theory is commonly used to evaluate the efficiency of OWCs; however, this assumption tends to over-predict the hydrodynamic performance. Recently, numerical studies using a diverse set of commercial, open-source, or in-house Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier Stokes (RANS) and Large-Eddy Simulation codes show a better comparison to available experimental results but are computationally expensive. ANSYS Fluent was found to be the most widely used CFD code applied to the study of the OWCs, with a high degree of accuracy in terms of experimental validation of numerical results.

16 TIDAL AND WAVE POWER↗

Summary of DASSH-CFD Inter-Assembly Heat Transfer Comparison

Fast reactor core design requires integration of detailed power distributions obtained from neutronics models and thermal fluids calculations to determine temperature distributions and flow conditions. During the design phase, calculations may be repeated as specifications change and computational expense must be balanced with solution accuracy, creating an opportunity for the use of intermediate-fidelity codes. To that end, the Ducted Assembly Steady-State Heat Transfer Software (DASSH) has been developed at Argonne National Laboratory to perform full-core, steady state coolant and fuel pin temperature calculations in reactors consisting of hexagonal, ducted assemblies. DASSH is a first-order, finite volume subchannel code based on methodologies initially introduced in the legacy thermal hydraulics codes SUPERENERGY-2 and SE2-ANL. It can work coupled with the Argonne Reactor Computational (ARC) code suite to obtain neutron and gamma power distributions based on neutron transport solutions and features many improvements and new capabilities compared to its predecessors. DASSH calculates temperatures by balancing energy between subchannels and relies on correlations to account for flow distribution and coolant mixing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Direct comparison of gyrokinetic and fluid scrape-off layer simulations

Typically, fluid simulations are used for tokamak divertor design. However, fluid models are only valid if the scrape-off layer (SOL) is highly collisional. This assumption is valid in many present-day experiments but is questionable in the upstream SOL of some high-power scenarios envisioned for burning plasmas and fusion pilot plants. This paper reports on comparisons between fluid and kinetic simulations of the SOL for upstream parameters and geometry representative of the Spherical Tokamak for Energy Production fusion pilot plant. The SOLPS-ITER (fluid) and Gkeyll (gyrokinetic) codes are operated in a two-dimensional axisymmetric mode, which replaces turbulence with ad-hoc diffusivities. In kinetic simulations, we observe that the ions in the upstream SOL experience significant mirror trapping. This substantially increases the upstream temperature and has important implications for impurity dynamics. We show that the mirror force, which is excluded in SOLPS’s fluid equations, enhances the electrostatic potential drop along the field line in the SOL. We also show that the assumption of equal main ion and impurity temperatures, which is made in commonly used fluid codes, is invalid for the regimes explored here. The combination of these effects results in superior confinement of impurities to the divertor region in kinetic simulations, consistent with our earlier predictions [Kotschenreuther et al., in 29th IAEA 29 Fusion Energy Conference (IAEA, London, UK, 2023)]. This effect can be dramatic, reducing the midplane impurity density by orders of magnitude. These results indicate that in lower collisionality SOL’s the tolerable downstream impurity densities may be higher than would be predicted by fluid simulations, allowing for higher radiated power while avoiding unacceptable core contamination. Our results highlight the importance of kinetic simulations for divertor design and optimization for fusion pilot plants.

Computational fluid dynamics↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Jet Impingement Cooling of Electric Machines with Driveline Fluids

In the presentation thermal management of electric traction drives is discussed and capabilities of NREL's Advanced Power Electronics and Electric Machines group is reviewed. Emphasis is made on jet impingement cooling technique of electric machines with driveline fluids and experimental measurements of associated heat transfer coefficients.

47 OTHER INSTRUMENTATION↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Technoeconomic optimization of superalloy supercritical CO 2 microtube shell-and-tube-heat exchangers

Heat exchangers are critical components of aerospace systems and improve efficiency of operation by providing waste heat recovery. Supercritical CO has emerged as a promising candidate working fluid due to its potential in increasing the power density of heat exchangers. In this paper, a generalized costing model is developed to estimate the capital costs incurred to manufacture microtube shell-and-tube heat exchangers. This model is utilized in conjunction with an accurate and efficient 2D numerical shell-and-tube heat exchanger performance prediction model to conduct optimization studies with two key objectives – minimization of cost and maximization of heat exchanger power density – on supercritical CO microtube heat exchangers utilizing superalloy Haynes 282 as the solid material. A methodology is then demonstrated to optimize these heat exchangers using Particle Swarm Optimization for aerospace applications and highly compact and cost-effective optimal designs with power density around 20 and cost per conductance less than 5 $ ∙ K/W are obtained.

42 ENGINEERING↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-pressure flow through test vessel for neutron imaging and neutron diffraction-based strain measurement of geological materials

Neutron scattering and neutron imaging have emerged as powerful methods for experimentally investigating material deformation and fluid flow in the interior of otherwise inaccessible or opaque structures. This paper describes the design and provides example uses of a pressure cell developed for investigating such behaviors within geological materials. The cell can accommodate cylindrical samples with diameters up to 38.1 mm and lengths up to 154 mm. Additionally, ports in the cell and a pressure isolating sleeve around the sample allow the independent application of confining pressure up to 69 MPa and axial pressure up to 34.5 MPa. Furthermore, two material versions of the cell have been manufactured and used to date. An aluminum version is typically used for temperatures below 40 °C, because of its relative transparency to neutrons, while a titanium version, which is comparatively more neutron attenuating, is used for experiments requiring triaxial pressurization under conditions up to 350 °C. The pressure cells were commissioned at the VULCAN engineering diffractometer at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source, and have since been used at the ORNL high flux isotope reactor CG1-D imaging beamline, National Institute of Standard and Technology (NIST) BT-2, and NIST NG6 imaging beamlines.

47 OTHER INSTRUMENTATION↗

Unsupervised discovery of extreme weather events using universal representations of emergent organization

Spontaneous self-organization is ubiquitous in systems far from thermodynamic equilibrium. While organized structures that emerge dominate transport properties, universal representations that identify and describe these key objects remain elusive. Here, we introduce a theoretically grounded framework for describing emergent organization that, via data-driven algorithms, is constructive in practice. Its building blocks are spacetime lightcones that embody how information propagates across a system through local interactions. We show that predictive equivalence classes of lightcones—local causal states—capture organized behaviors in complex spatiotemporal systems. Employing an unsupervised physics-informed machine learning algorithm and a high-performance computing implementation, we demonstrate automatically discovering organized structures in two real-world domain science problems. We show that local causal states identify vortices and track their power-law decay behavior in two-dimensional fluid turbulence. We then show how to detect and track familiar extreme weather events—hurricanes and atmospheric rivers—and discover other novel structures associated with precipitation extremes in high-resolution climate data at the grid-cell level.

Rupe, Adam [Pacific Northwest National Laboratory ↗

High Temperature Sodium Submersible Flowmeter Design and Analysis

This work details the design and analysis of a permanent magnet flowmeter designed to be submerged in a pool type sodium fast reactor environment. Recently developed Samarium Cobalt rare earth magnets were utilized that have demonstrated resilience to temperature and neutron flux up to 550 °C and 10 18 n/cm 2 , respectively. This paper will discuss the theory, design, calibration and uncertainty quantification of the flowmeter. The flowmeter was calibrated over a flowrate range of 11.4 - 90.9 LPM at temperatures of 220 and 400 °C, yielding an uncertainty in calibration of 2-3.6%. Here, a finite element model was developed and validated experimentally, yielding <; 3.2% error.

47 OTHER INSTRUMENTATION↗

srlife

Solar receiver structural life estimation tool. This software estimates the life of a tubular concentrating solar power receiver given user input describing the working fluid pressures and temperatures. sf-20-068

Messner, Mark↗