Search NASA⌕ Search

SEARCH · Search NASA

Results for “FNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

AUP first Pre-Series Cold Mass Installation into the Cryostat

For the HiLumi LHC Upgrade (HL-LHC), new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP), ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested, and delivered to CERN. The first LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during fall 2022 and spring/summer 2023, respectively. This paper summarizes the assembly process and experience of the first LQXFA Cryostat Assembly at FNAL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]↗

Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb

This report details the final measurement of the muon magnetic anomaly, $a_μ=(g_μ-2)/2$, by the Muon $g-2$ experiment at Fermi National Accelerator Laboratory (FNAL), using positive muons collected from 2021 to 2023. The value of $a_μ$ is determined from the ratio of the anomalous spin precession frequency to the shielded proton precession frequency in the muon storage ring magnetic field, combined with external constants known at the 22 ppb level. The new dataset, containing over $2.5$ times the statistics of our previous results, yields $a_μ=116\,592\,0710(162)\times 10^{-12}$ (139 ppb), or $a_μ=116\,592\,0705(148)\times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ^{\text{Exp}}=116\,592\,0715(145)\times 10^{-12}$ (124 ppb).

Aguillard, D. P. [U. Michigan, Ann Arbor] (ORCID:0↗

Development and coil fabrication for the LARP 3.7-m long Nb3Sn quadruple

The U.S. LHC Accelerator Research Program (LARP) has started the fabrication of 3.7-m long Nb{sub 3}Sn quadrupole models. The Long Quadrupoles (LQ) are 'Proof-of-Principle' magnets which are to demonstrate that Nb3Sn technology is mature for use in high energy particle accelerators. Their design is based on the LARP Technological Quadrupole (TQ) models, developed at FNAL and LBNL, which have design gradients higher than 200 T/m and an aperture of 90 mm. The plans for the LQ R&D and a design update are presented and discussed in this paper. The challenges of fabricating long accelerator-quality Nb{sub 3}Sn coils are presented together with the solutions adopted for the LQ coils (based on the TQ experience). During the fabrication and inspection of practice coils some problems were found and corrected. The fabrication at BNL and FNAL of the set of coils for the first Long Quadrupole is in progress.

43 PARTICLE ACCELERATORS↗

JASMIN: Japanese-American study of muon interactions and neutron detection

Experimental studies of shielding and radiation effects at Fermi National Accelerator Laboratory (FNAL) have been carried out under collaboration between FNAL and Japan, aiming at benchmarking of simulation codes and study of irradiation effects for upgrade and design of new high-energy accelerator facilities. The purposes of this collaboration are (1) acquisition of shielding data in a proton beam energy domain above 100GeV; (2) further evaluation of predictive accuracy of the PHITS and MARS codes; (3) modification of physics models and data in these codes if needed; (4) establishment of irradiation field for radiation effect tests; and (5) development of a code module for improved description of radiation effects. A series of experiments has been performed at the Pbar target station and NuMI facility, using irradiation of targets with 120 GeV protons for antiproton and neutrino production, as well as the M-test beam line (M-test) for measuring nuclear data and detector responses. Various nuclear and shielding data have been measured by activation methods with chemical separation techniques as well as by other detectors such as a Bonner ball counter. Analyses with the experimental data are in progress for benchmarking the PHITS and MARS15 codes. In this presentation recent activities and results are reviewed.

43 PARTICLE ACCELERATORS↗

Ionization profile monitors for the IOTA proton beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors — one vertical and one horizontal — are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. Furthermore, in this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

Beam diagnostics↗

A Computational Procedure for Assessing I$_{c}(\varepsilon$) in Nb$_{3}$Sn/Bi-2212 Hybrid Magnets

The critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors are prone to a reduction in critical current before reaching their structural mechanical limit. Here, in this work, the magnetic and mechanical analysis of the FNAL 4-layer Bi-2212/Nb$_{3}$Sn hybrid dipole magnet is reported, aimed at predicting the critical current degradation for both the superconductors during powering at 16T. All the Rutherford cables in the coils of the hybrid magnet were modeled at the strand level in Ansys APDL with the heterogeneous cable model. Utilizing this detailed geometry, it was possible to evaluate the effects of strain on the critical current degradation for both the Nb$_{3}$Sn and Bi-2212 superconductors under the intense Lorentz forces. The analysis presented in this paper integrates strain-dependent critical current laws, with parameters derived from experimental data, to simulate the hybrid magnet's performance for all possible current-powering configurations. The proposed methodology enables a detailed assessment of conductor integrity and I$_{C}(\varepsilon$) reduction in existing hybrid magnet designs, providing a versatile and rigorous framework for optimizing future high-field hybrid magnets.

D'Agliano, A. [Lawrence Berkeley National Laborato↗

FEM Modeling and Simulation of 2-D High Specific Heat Nb 3 Sn Wires

In the past few years, new high specific heat Nb 3 Sn wires have gained much focus at FNAL. Indeed, they have proved to be more stable against thermal perturbations with respect to standard wires. Nevertheless, a trade off exists between their thermal efficiency and production feasibility. In this report I describe the thermal and structural models that I have developed by exploiting ANSYS Mechanical APDL ® , which I got acquainted with at the beginning of my training. The aim has been to optimize the location of high specific heat elements in order to obtain an optimal thermal stability, while minimizing the risk of wire breakage during drawing. FEM results are compared with experimental ones made beforehand. Other minimum quench energy (MQE) thermal models have been developed for expected new experimental results. New data may improve the understanding of the embedded physical uncertainties in the model.

36 MATERIALS SCIENCE↗

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS↗

Common-Coil Dipole for a Very Large Hadron Collider [Book Chapter]

A dipole magnet based on the common-coil design and pre-reacted Nb$_{3}$Sn cable was developed at the Fermi National Accelerator Laboratory (FNAL) for a Very Large Hadron Collider. Three technological racetrack models and a short dipole model have been fabricated and tested. This chapter summarizes the main results of this program.

43 PARTICLE ACCELERATORS↗

Coupling of nitric acid digestion and anion-exchange resin separation for the determination of methylmercury isotopic composition within organisms

Isotope ratios of methylmercury (MeHg) within organisms can be used to identify sources of MeHg that have accumulated in food webs, but these isotopic compositions are masked in organisms at lower trophic levels by the presence of inorganic mercury (iHg). To facilitate measurement of MeHg isotope ratios in organisms, we developed a method of extracting and isolating MeHg from fsh and aquatic invertebrates for compound-specifc isotopic analysis involving nitric acid digestion, batch anion-exchange resin separation, and pre-concentration by purge and trap. Recovery of MeHg was quantifed after each step in the procedure, and the average cumulative recovery of MeHg was 93.4±2.9% (1 SD, n=28) for biological reference materials and natural biota samples and 96.9±1.8% (1 SD, n=5) for aqueous MeHgCl standards. The amount of iHg impurities was also quantifed after each step, and the average MeHg purity was 97.8±4.3% (1 SD, n=28) across all reference materials and natural biota samples after the fnal separation step. Measured MeHg isotopic compositions of reference materials agreed with literature values obtained using other MeHg separation techniques, and MeHg isotope ratios of aqueous standards, reference materials, and natural biota samples were reproducible. On average, the reproducibility associated with reference material process replicates (2 SD) was 0.10‰ for δ 202 MeHg and 0.04‰ for Δ 199 MeHg. This new method provides a streamlined, reliable technique that utilizes a single sample aliquot for MeHg concentration and isotopic analysis. Furthermore, this promotes a tight coupling between MeHg concentration, %MeHg, and Hg isotopic composition, which may be especially benefcial for studying complex food webs with multiple isotopically distinct sources of iHg and/or MeHg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A system to test the effects of materials on the electron drift lifetime in liquid argon and observations on the effect of water

A materials test system (MTS) has been developed at FNAL to assess the suitability of materials for use in a large liquid argon time projection chamber. During development of the MTS, it was noted that controlling the cryostat pressure with a 'raining' condenser reduced the electron drift lifetime in the liquid argon. The effect of condensing has been investigated using a series of passive materials to filter the condensate. We report the results of these studies and of tests on different candidate materials for detector construction. The inferred reduction of electron drift lifetime by water concentrations in the parts per trillion is of particular interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Prototypes for the ALICE Electromagnetic Calorimeter

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4 x 4 array of final design modules showed an energy resolution of about 11%/{radical}E(GeV) {circle_plus} 1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 mm {circle_plus} 5.3 mm/{radical}E(GeV). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MINER$\nu$A Data Acquisition System and Infrastructure

MINERvA (Main INjector ExpeRiment v-A) is a new few-GeV neutrino cross-section experiment that began taking data in the FNAL NuMI (Fermi National Accelerator Laboratory Neutrinos at the Main Injector) beam-line in March of 2010. MINERvA employs a fine-grained scintillator detector capable of complete kinematic characterization of neutrino interactions. This paper describes the MINERvA data acquisition system (DAQ) including the readout electronics, software, and computing architecture.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterisation of the PXIE Allison-type emittance scanner

An Allison-type emittance scanner has been designed for PXIE at FNAL with the goal of providing fast and accurate phase space reconstruction. The device has been modified from previous LBNL/SNS designs to operate in both pulsed and DC modes with the addition of water-cooled front slits. Extensive calibration techniques and error analysis allowed confinement of uncertainty to the <5% level (with known caveats). With a 16-bit, 1 MHz electronics scheme the device is able to analyse a pulse with a resolution of 1 μs, allowing for analysis of neutralisation effects. As a result, this paper describes a detailed breakdown of the R&D, as well as post-run analysis techniques.

43 PARTICLE ACCELERATORS↗

Scintillation Light DAQ and Trigger System for the ICARUS T600 Experiment at Fermilab

ICARUS T600 will operate at shallow depths as far detector for the Short Baseline Neutrino (SBN) program at FNAL taking data from the BNB and NuMI beams. The entire apparatus will be exposed to the huge cosmic background which can mimic genuine neutrino interactions. To distinguish the signals related to the neutrino beams from those induced by cosmic rays, the detector will be provided with a trigger system that will exploit the coincidence of the prompt signals from the liquid argon scintillation light, detected by 360 Photomultiplier Tubes (PMTs), with a beam gate window generated in correspondence to the expected arrival time of neutrinos in the T600.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gain stability of Hamamatsu R5912-MOD photomultipliers at low temperature

The Photon Detection System (PDS) is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 PhotoMultiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operating at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu R5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70 °C, although this temperature is rather higher than that of the liquid Argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗