Search NASA⌕ Search

SEARCH · Search NASA

Results for “FORCE DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Miniature Latching Valve

A miniature latching valve has been invented to satisfy a need for an electrically controllable on/off pneumatic valve that is lightweight and compact and remains in the most recently commanded open or closed state when power is not supplied. The valve includes a poppet that is moved into or out of contact with a seat to effect closure or opening, respectively, of the flow path. Motion of the poppet is initiated by electrical heating of one of two opposing pairs of nickel/titanium shape-memory alloy (SMA) wires above their transition temperature: heated wires contract to their remembered length, applying tension to pull the poppet toward or away from the seat. A latch consisting mainly of a bistable Belleville washer (a conical spring) made of a hardened stainless steel operates between two stable positions corresponding to the fully closed or fully open state, holding the poppet in one of these positions when power is not applied to either pair of SMA wires. To obtain maximum actuation force and displacement, the SMA wires must be kept in tension. The mounting fixtures at the ends of the wires must support large tensile stresses without creating stress concentrations that would limit the fatigue lives of the wires. An earlier design provided for each wire to be crimped in a conical opening with a conical steel ferrule that was swaged into the opening to produce a large, uniformly distributed holding force. In a subsequent design, the conical ferrule was replaced with a larger crimped cylindrical ferrule depicted in the figure. A major problem in designing the valve was to protect the SMA wires from a bake-out temperature of 300 C. The problem was solved by incorporating the SMA wires into an actuator module that is inserted into a barrel of the valve body and is held in place by miniature clip rings.

Johnson, A. David↗

Evaluation of RANS vs. LES simulation of fluid flow through 3 × 3 rod bundle with a simple spacer grid as a precursor to coupled fluid–structure interaction simulations

The research literature on Computational Fluid Dynamics (CFD) of coolant flow through rod bundles with spacer-grids and mixing vanes is replete, ranging from high fidelity Large Eddy Simulation (LES)/Direct Numerical Simulation (DNS) simulations to Reynolds-Averaged Navier–Stokes (RANS) modeled studies. The mixing of flow between subchannels and the pressure drop through the bundle are fundamental quantities useful for comparing and evaluating CFD methods. Less commonly observed and compared are the forces exerted onto the structure by the fluid. The present study seeks to evaluate the use of RANS simulations for predicting the structural response to fluid flow. Wall resolved RANS simulations are benchmarked against LES simulations of fluid flow at a Reynolds number of 15,000 through a 3 × 3 fuel rod bundle with a simple spacer grid. Velocity line-plots are compared showing good agreement between RANS and LES results, ascertaining that the former is capable of capturing the essential time-averaged velocity profile. Additionally, the distribution of forces on the spacer grid and fuel rods are collected as a function of time and space. The RANS methods are evaluated using the frequency and magnitude of the fluctuating forces on various portions of the structure as compared to LES. In conclusion, the power spectral density evaluation of the models reveal underprediction of force amplitude on the rod walls by RANS and also discrepancy in the prediction of high frequency spectra, especially in the immediate vicinity of spacer-grid structure, which may be attributed to the lack of random turbulence fluctuation or insufficient modeling of small-scale eddies in RANS simulation.

FIV↗

Aerodynamic Characteristics of a Circular Cylinder at Mach Number of 6.86 and Angles of Attack up to 90 Degrees

Pressure-distribution and force tests of a circular cylinder have been made in the Langley 11-inch hypersonic tunnel at a Mach number of 6.86, a Reynolds number of 129,000 based on diameter, and angles of attack up to 90 degrees. The results are compared with the hypersonic approximation of Grimminger, Williams, and Young and with a simple modification of the Newtonian flow theory. The comparison of experimental results shows that either theory gives adequate general aerodynamic characteristics but that the modified Newtonian theory gives a more accurate prediction of the pressure distribution. The calculated crossflow drag coefficients plotted as a function of crossflow Mach number were found to be in reasonable agreement with similar results obtained from other investigations at lower supersonic Mach numbers. Comparison of the results of this investigation with data obtained at a lower Mach number indicates that the drag coefficient of a cylinder normal to the flow is relatively constant for Mach numbers above about 4.

Penland, Jim A↗

Quantum stress and torsion distributions in the deuteron

Stress distributions in the deuteron are related to form factors of the asymmetric energy-momentum tensor through three-dimensional Fourier transforms. There are eleven such form factors, which we calculate in an impulse approximation. We compare the obtained form factors to prior results for the six form factors that have been previously calculated. We then elaborate on the formalism for relating the form factors to internal distributions of mass, mass flux, momentum, stresses, and forces, and obtain results for all of these distributions. We obtain the principal stresses for the symmetric part of the stress tensor, and show that the antisymmetric part describes the reorientation of fermion spin by torsion stress when the nucleon moves between the S and D waves. Force distributions in the nucleons depend on the so-called nonconserved form factors through the Cauchy momentum equation, and are nonradial owing to the presence of tensor forces and spin-orbit coupling.

QCD phenomenology↗

Comparison of Convective Heat Transfer Correlations and Their Application to Nuclear Thermal Propulsion Reactors

This study analyzes various Nusselt number and friction factor correlations and applies them to a Small Nuclear Rocket Engine model with a Sinusoidal power distribution profile to understand their effects on the temperatures and pressures inside the reactor. A nodal thermal hydraulic solver was used to determine the fluid and channel surface temperatures while also incorporating variable fluid properties and channel roughness. The results showed that the considered friction factors could essentially be used interchangeably given that their difference affected the pressure by less than 1%. However, large variations in the tube surface temperature were obtained for the different Nusselt numbers while the fluid temperature distribution was forced to remain the same. Supersonic flow conditions presented by Maynard Taylor are investigated to serve as a baseline for how experimental errors can lead to uncertainties in the reported empirical correlations. Detailed experimental investigation is necessary to determine the Nusselt number correlation that will provide the best prediction of the thermal hydraulic performance inside the reactor fluid flow channels.

Experiment↗

Impact of tensor forces on quasifission product yield distributions

Quantum shell effects are crucial for the stability and structure of atomic nuclei and play a key role in the discovery of superheavy elements. Furthermore, during nuclear collisions, the dynamical evolution of these shell effects disrupts the equilibration process necessary for forming a compound nucleus, leading to the breakup of the initial composite as a result of quasifission. As such, quasifission reactions hinder the formation of a superheavy element.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined Radiation and Forced Convection for Flow of a Transparent Gas in a Tube with Sinusoidal Axial Wall Heat Flux Distribution

An analysis is made of the influence that radiation exchanges between elements on the inside surface of a tube have on the wall and gas temperature distributions for forced-convection flow. The wall heat generation has a chopped sine distribution with length along the tube, which is a distribution often encountered in nuclear-reactor channels. The flowing gas is assumed transparent to thermal radiation and hence does not participate directly in the radiative exchange process. Axial heat conduction is neglected in the gas and tube wall, and the convective-heat-transfer coefficient and fluid properties are assumed constant. Several numerical examples are given to illustrate the effects of eight independent parameters such as wall emissivity, Stanton number, and length-diameter ratio. In some instances the radiation exchanges reduced the peak wall temperature or caused a reduction in the exit gas temperature because of radiation losses from the tube end openings.

TUBE↗

The ArborX Library: Version 2.0

This article provides an overview of the 2.0 release of the ArborX library, a performance portable geometric search library based on Kokkos. We describe the major changes in ArborX 2.0 including a new interface for the library to support a wider range of user problems, new search data structures (brute force and distributed), support for user functions to be executed on the results (callbacks), and an expanded set of the supported algorithms (ray tracing and clustering).

GPU↗

In-situ X-ray Evaluation of Traumatic Brain Injury Dynamic Impacts (Final Report)

The goal of this project was to create an in-situ model of traumatic brain injury that allows for analysis of chronic traumatic encephalopathy (CTE) development. CTE is a neurodegenerative disease that occurs as a result of traumatic brain injuries. The resulting neurodegeneration and atrophying of cortical brain tissue develop as tau proteins build-up around small blood vessels and at the base of cortical sulci. Aggregation of tau proteins results in blood vessel damage and neurological function loss, leading to cortical tissue atrophy. This occurs only at some neuronal junctions in the brain after trauma. It has been conjectured that the geometrical distribution of force along neurons is responsible for initiation of tau deposition. However, to assess the validity of this proposition, it is necessary to analyze the mechanical response under dynamic loading associated with brain trauma in-situ

42 ENGINEERING↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗