Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance characteristics of rotating wickless heat pipes

A theoretical model was derived for laminar film condensation on the inside of a rotating, truncated cone which includes the effects of vapor shear and vapor pressure drop. Results are compared to those of previous investigations. Experimental data are presented for rotational speeds of 700, 1,400, 2,100, and 2,800 rpm using water, ethyl alcohol, and Freon 113 as working fluids. Agreement between theory and experiment is within + or - 20 percent.

Marto, P. J.↗

Flash evaporator systems test

A flash evaporator heat rejection system representative of that proposed for the space shuttle orbiter underwent extensive system testing at the NASA Johnson Space Center (JSC) to determine its operational suitability and to establish system performance/operational characteristics for use in the shuttle system. During the tests the evaporator system demonstrated its suitability to meet the shuttle requirements by: (1) efficient operation with 90 to 95% water evaporation efficiency, (2) control of outlet temperature to 40 + or - 2 F for partial heat load operation, (3) stability of control system for rapid changes in Freon inlet temperature, and (4) repeated dormant-to-active device operation without any startup procedures.

Dietz, J. B.↗

Effect of transient liquid flow on retention characteristics of screen acquisition systems

A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

Cady, E. C.↗

Evaluation of performance impairment by spacecraft contaminants

The environmental contaminants (isolated as off-gases in Skylab and Apollo missions) were evaluated. Specifically, six contaminants were evaluated for their effects on the behavior of juvenile baboons. The concentrations of contaminants were determined through preliminary range-finding studies with laboratory rats. The contaminants evaluated were acetone, methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), trichloroethylene (TCE), heptane and Freon 21. When the studies of the individual gases were completed, the baboons were also exposed to a mixture of MEK and TCE. The data obtained revealed alterations in the behavior of baboons exposed to relatively low levels of the contaminants. These findings were presented at the First International Symposium on Voluntary Inhalation of Industrial Solvents in Mexico City, June 21-24, 1976. A preprint of the proceedings is included.

Geller, I.↗

Sulfur poisoning of hydrocarbon oxidation by palladium

Using a differential bed recycle reactor the oxidation of ethane and diethyl ketone by a Pd catalyst was studied at the 0-30 ppm level in air. In both cases first order kinetics were observed. The ethane oxidation rate was characterized n the Arrhenius form by a pre-exponential of 1.0 x 10 to the 8th power cm/sec and an E sub a of 27 kcal/mole. The diethyl ketone oxidation rate was characterized by a pre-exponential of 5.7 x -1000 cm/sec and E sub a of 14 kcal/mole. Poisoning of ethan oxidation was also investigated by hydrogen sulfide and to a smaller extent by the refrigerants Freon 22 and Gentron 142-B. Poisoning by Gentron 142-B was much more severe than by hydrogen sulfide. Kinetic experiments indicated that only the pre-exponential was changing.

Baumgartner, A. J.↗

Corona-discharge air-purification system

Plasma reaction chamber removes trace contaminants from spacecraft, submarines, and other closed environments by oxidizing contaminants to produce carbon dioxide and water. Contaminants are alcohols, esters, hydrogen sulfide, and ammonia. Others are lubricant solvents such as Freons, aromatics, and Ketones. Contaminants are removed from chamber by scrubber.

Wydeven, T. J.↗

Measurements of blast waves from bursting frangible spheres pressurized with flash-evaporation vapor or liquid

Incident overpressure data from frangible spheres pressurized with a flash-evaporating fluid in liquid and vapor form were obtained in laboratory experiments. Glass spheres under higher than ambient internal pressure of Freon-12 were purposely burst to obtain time histories of overpressure. Nondimensional peak pressures, arrival and duration times, and impulses are presented, and whenever possible plotted and compared with compiled data for Pentolite high-explosive. The data are generally quite repeatable and show differences from blast data produced by condensed high-explosives.

Esparaza, E. D.↗

Conceptual design for spacelab two-phase flow experiments

KC-135 aircraft tests confirmed the gravity sensitivity of two phase flow correlations. The prime component of the apparatus is a 1.5 cm dia by 90 cm fused quartz tube test section selected for visual observation. The water-cabin air system with water recycle was a clear choice for a flow regime-pressure drop test since it was used satisfactorily on KC-135 tests. Freon-11 with either overboard dump or with liquid-recycle will be used for the heat transfer test. The two experiments use common hardware. The experimental plan covers 120 data points in six hours with mass velocities from 10 to 640 kg/sec-sq m and qualities 0.01 to 0.64. The apparatus with pump, separator, storage tank and controls is mounted in a double spacelab rack. Supporting hardware, procedures, measured variables and program costs are defined.

Bradshaw, R. D.↗

Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure

Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.

Pagel, L. L.↗

Conceptual design for spacelab pool boiling experiment

A pool boiling heat transfer experiment to be incorporated with a larger two-phase flow experiment on Spacelab was designed to confirm (or alter) the results of earth-normal gravity experiments which indicate that the hydrodynamic peak and minimum pool boiling heat fluxes vanish at very low gravity. Twelve small sealed test cells containing water, methanol or Freon 113 and cylindrical heaters of various sizes are to be built. Each cell will be subjected to one or more 45 sec tests in which the surface heat flux on the heaters is increased linearly until the surface temperature reaches a limiting value of 500 C. The entire boiling process will be photographed in slow-motion. Boiling curves will be constructed from thermocouple and electric input data, for comparison with the motion picture records. The conduct of the experiment will require no more than a few hours of operator time.

Lienhard, J. H.↗

Measurement of solar radiation at ground level in the region 1950-2150 A using ammonia actinometry

The use of ammonia as an actinometer for measurement of the solar flux in the region 1950-2150 A is presented. The solar flux was found to be 270 million photons/sq cm per sec at ground level in this wavelength interval in an area with minimum overhead ozone concentration. The advantages of this method over previously used methods are discussed, and the results are related to the present estimates of the tropospheric photodissociation rates for the freons CFCl3 and CF2Cl2 by radiation in this wavelength region.

Knoot, P.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗

Results of heating mode performance tests of a solar-assisted heat pump

The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

Jones, C. B.↗

Resolution enhanced sound detecting apparatus

An apparatus is described for enhancing the resolution of a sound detector of the type which includes an acoustic mirror for focusing sound from an object onto a microphone to enable the determination of the location from which the sound arises. The enhancement apparatus includes an enclosure which surrounds the space between the mirror and microphone, and contains a gas heavier than air, such as Freon, through which sound moves slower and therefore with a shorter wavelength than in air, so that a mirror of given size has greater resolving power. An acoustically transparent front wall of the enclosure which lies forward of the mirror, can include a pair of thin sheets with pressured air between them, to form an end of the region of heavy gas into a concave shape.

Kendall, J. M.↗

Stratospheric-related research using the shock tube

The capabilities of shock tubes used in stratospheric-related research are considered, and the results of three independent shock tube research projects are reported. The studies are concerned with the evaluation of stratospheric ozone depletion. In the first experiment, photoabsorption cross sections of Freon 11 and 12 at stratospheric temperatures were measured using rarefaction waves. In the second experiment, reaction-rate coefficients were determined from measurements made behind reflected shock waves. In the third experiment, electronic-transition moments of the O2 Schumann-Runge system and the A2Pi-X2Pi system of ClO were deduced from intensity measurements made behind the incident shock.

Cooper, D. M.↗

Thermal study of interface between the Orbiter cold plate and typical Shuttle spacecraft payload flight electronics

Spacelab provides a set of Freon line plumbing and cold plates for experiment equipments which are located in the Shuttle pallet and which need active thermal control. The reported study deals with the thermal problem of attaching a Command and Data Handling module with various electronic boxes whose combined footprints on the baseplate are much larger than the cold plate. A description of two modules and the cold plate assembly in the pallet is presented and a thermal model description is provided. The method employed in modeling heat pipes-honey-comb matrix is based upon an effective conductance between the heat pipe vapor and the walls of the heat pipe. The considered thermal models and a computer program are used to perform steady-state thermal analyses. The temperature gradients in the large module baseplate attached to the small cold plate are predicted as a function of the interface plate thickness.

Hwangbo, H.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗

Engineering aspects of a thermal control subsystem for the 25 kW power module

The paper presents the key trade study results, analysis results, and the recommended thermal control approach for the 25 kW power module defined by NASA. Power conversion inefficiencies and component heat dissipation results in a minimum heat rejection requirement of 9 kW to maintain the power module equipment at desired temperature levels. Additionally, some cooling capacity should be provided for user payloads in the sortie and free-flying modes. The baseline thermal control subsystem includes a dual-loop-pumped Freon-21 coolant with the heat rejected from deployable existing orbiter radiators. Thermal analysis included an assessment of spacecraft orientations, radiator shapes and locations, and comparison of hybrid heat pipe and all liquid panels.

Schroeder, P. E.↗