Conceptual design for spacelab two-phase flow experiments

KC-135 aircraft tests confirmed the gravity sensitivity of two phase flow correlations. The prime component of the apparatus is a 1.5 cm dia by 90 cm fused quartz tube test section selected for visual observation. The water-cabin air system with water recycle was a clear choice for a flow regime-pressure drop test since it was used satisfactorily on KC-135 tests. Freon-11 with either overboard dump or with liquid-recycle will be used for the heat transfer test. The two experiments use common hardware. The experimental plan covers 120 data points in six hours with mass velocities from 10 to 640 kg/sec-sq m and qualities 0.01 to 0.64. The apparatus with pump, separator, storage tank and controls is mounted in a double spacelab rack. Supporting hardware, procedures, measured variables and program costs are defined.

Bradshaw, R. D.↗

Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure

Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.

Pagel, L. L.↗

Conceptual design for spacelab pool boiling experiment

A pool boiling heat transfer experiment to be incorporated with a larger two-phase flow experiment on Spacelab was designed to confirm (or alter) the results of earth-normal gravity experiments which indicate that the hydrodynamic peak and minimum pool boiling heat fluxes vanish at very low gravity. Twelve small sealed test cells containing water, methanol or Freon 113 and cylindrical heaters of various sizes are to be built. Each cell will be subjected to one or more 45 sec tests in which the surface heat flux on the heaters is increased linearly until the surface temperature reaches a limiting value of 500 C. The entire boiling process will be photographed in slow-motion. Boiling curves will be constructed from thermocouple and electric input data, for comparison with the motion picture records. The conduct of the experiment will require no more than a few hours of operator time.

Lienhard, J. H.↗

Measurement of solar radiation at ground level in the region 1950-2150 A using ammonia actinometry

The use of ammonia as an actinometer for measurement of the solar flux in the region 1950-2150 A is presented. The solar flux was found to be 270 million photons/sq cm per sec at ground level in this wavelength interval in an area with minimum overhead ozone concentration. The advantages of this method over previously used methods are discussed, and the results are related to the present estimates of the tropospheric photodissociation rates for the freons CFCl3 and CF2Cl2 by radiation in this wavelength region.

Knoot, P.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗

Results of heating mode performance tests of a solar-assisted heat pump

The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

Jones, C. B.↗

Resolution enhanced sound detecting apparatus

An apparatus is described for enhancing the resolution of a sound detector of the type which includes an acoustic mirror for focusing sound from an object onto a microphone to enable the determination of the location from which the sound arises. The enhancement apparatus includes an enclosure which surrounds the space between the mirror and microphone, and contains a gas heavier than air, such as Freon, through which sound moves slower and therefore with a shorter wavelength than in air, so that a mirror of given size has greater resolving power. An acoustically transparent front wall of the enclosure which lies forward of the mirror, can include a pair of thin sheets with pressured air between them, to form an end of the region of heavy gas into a concave shape.

Kendall, J. M.↗

Stratospheric-related research using the shock tube

The capabilities of shock tubes used in stratospheric-related research are considered, and the results of three independent shock tube research projects are reported. The studies are concerned with the evaluation of stratospheric ozone depletion. In the first experiment, photoabsorption cross sections of Freon 11 and 12 at stratospheric temperatures were measured using rarefaction waves. In the second experiment, reaction-rate coefficients were determined from measurements made behind reflected shock waves. In the third experiment, electronic-transition moments of the O2 Schumann-Runge system and the A2Pi-X2Pi system of ClO were deduced from intensity measurements made behind the incident shock.

Cooper, D. M.↗

Thermal study of interface between the Orbiter cold plate and typical Shuttle spacecraft payload flight electronics

Spacelab provides a set of Freon line plumbing and cold plates for experiment equipments which are located in the Shuttle pallet and which need active thermal control. The reported study deals with the thermal problem of attaching a Command and Data Handling module with various electronic boxes whose combined footprints on the baseplate are much larger than the cold plate. A description of two modules and the cold plate assembly in the pallet is presented and a thermal model description is provided. The method employed in modeling heat pipes-honey-comb matrix is based upon an effective conductance between the heat pipe vapor and the walls of the heat pipe. The considered thermal models and a computer program are used to perform steady-state thermal analyses. The temperature gradients in the large module baseplate attached to the small cold plate are predicted as a function of the interface plate thickness.

Hwangbo, H.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗

Engineering aspects of a thermal control subsystem for the 25 kW power module

The paper presents the key trade study results, analysis results, and the recommended thermal control approach for the 25 kW power module defined by NASA. Power conversion inefficiencies and component heat dissipation results in a minimum heat rejection requirement of 9 kW to maintain the power module equipment at desired temperature levels. Additionally, some cooling capacity should be provided for user payloads in the sortie and free-flying modes. The baseline thermal control subsystem includes a dual-loop-pumped Freon-21 coolant with the heat rejected from deployable existing orbiter radiators. Thermal analysis included an assessment of spacecraft orientations, radiator shapes and locations, and comparison of hybrid heat pipe and all liquid panels.

Schroeder, P. E.↗

Radioisotope thermoelectric generator cooling in the Shuttle bay

The paper describes a Shuttle-integrated radioisotope thermoelectric generator (RTG) that consists primarily of a pump package and plumbing connected directly to the Shuttle payload heat exchanger. The RTG utilizes on-board water evaporative cooling capability, which is normally used for ascent, entry, and for supplementing the radiators. Attention is given to the RTG cooling concepts which include: (1) an active thermal cooling system (ATCS), where two Freon-21 loops operate simultaneously to transport heat from the Orbiter subsystem and payloads through liquid-to-liquid heat exchangers and pin-fin coldplates to four heat sinks, and (2) an atmosphere revitalization system (ARS) which provides for thermal, pressure, and contaminate control of the crew cabin and its equipment. The use of a payload heat exchanger to reduce weight, cost and complexity associated with an independent cooling system was investigated in detail.

Stimpson, L. D.↗

Automated Array Assembly Task In-depth Study of Silicon Wafer Surface Texturizing

Several aspects of silicon wafer surface texturizing were studied. A low cost cleaning method that utilizes recycled Freon in an ultrasonic vapor degreaser to remove organic and inorganic contaminants from the surface of silicon wafers as received from silicon suppliers was investigated. The use of clean dry air and high throughout wafer batch drying techniques was shown to lower the cost of wafer drying. A two stage texturizing process was examined for suitability in large scale production. Also, an in-depth gettering study with the two stage texturizing process was performed for the enhancement of solar cell efficiency, minimization of current versus voltage curve dispersion, and improvement in process reproducibility. The 10% efficiency improvement goal was exceeded for the near term implementation of flat plate photovoltaic cost reduction.

Jones, G. T.↗

Wind-tunnel experiments on divergence of forward-swept wings

An experimental study to investigate the aeroelastic behavior of forward-swept wings was conducted in the Langley Transonic Dynamics Tunnel. Seven flat-plate models with varying aspect ratios and wing sweep angles were tested at low speeds in air. Three models having the same planform but different airfoil sections (i.e., flat-plate, conventional, and supercritical) were tested at transonic speeds in Freon 12. Linear analyses were performed to provide predictions to compare with the measured aeroelastic instabilities which include both static divergence and flutter. Six subcritical response testing techniques were formulated and evaluated at transonic speeds for accuracy in predicting static divergence. Two "divergence stoppers" were developed and evaluated for use in protecting the model from structural damage during tests.

Ricketts, R. H.↗

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.↗

Space transportation system disconnect

The use of medium duty 300 psi fluid disconnects for orbital servicing was demonstrated to be both practical and technically feasible. A prototype disconnect was designed and tested, based on criteria formulated from a survey of expected usage requirements for orbital servicing concepts. Testing involved the comparison of three seal materials (EPR, Neoprene and Teflon), and two test media (helium and Freon 21), and was conducted over a temperature range of -150 F to +225 F. Results indicate low helium leakage (10 to the -4 power sccs) and extremely low engagement forces (56 lb sub f). Testing was also performed on a new seal design. Design concepts for a cryogenic disconnect and a high pressure disconnect were investigated. Results of an industry survey for usable orbital servicing disconnects and areas needing attention in future studies are discussed.

Source record↗

Temperature dependence of intensities of the 8-12 micron bands of CFCl3

The absolute intensities of the 8-12 micron bands from Freon 11 (CFCl3) were measured at temperatures of 294 and 216 K. Intensities of the bands centered at 798, 847, 934, and 1082 per cm are all observed to depend on temperature. The temperature dependence for the 847 and 1082 per cm fundamental regions is attributed to underlying hot bands; for the nu2 + nu5 combination band (934 per cm), the observed temperature dependence is in close agreement with theoretical prediction. The implication of these results on atmospheric IR remote-sensing is briefly discussed.

Nanes, R.↗

Sprayed Coating Renews Butyl Rubber

Damaged butyl rubber products are renewed by spray technique originally developed for protective suits worn by NASA workers. A commercial two-part adhesive is mixed with Freon-113 (or equivalent) trichlorotrifluoroethane to obtain optimum viscosity for spraying. Mix is applied with an external-air-mix spray gun.

Martin, R. B.↗