Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Frequency and time standards based on stored ions

The method of ion storage provides a basis for excellent time and frequency standards. This is due to the ability to confine ions for long periods of time without the usual perturbations associated with confinement (e.g., wall shifts). In addition, Doppler effects can be greatly suppressed. The use of stored ions for microwave frequency standards and the future possibilities for an optical frequency standard based on stored ions are addressed.

Bollinger, J. J.↗

Limitations on long-term stability and accuracy in atomic clocks

The limits to accuracy and long term stability in present atomic clocks are examined. Recent proposals for new frequency standards are discussed along with the advantages and disadvantages of frequency standards based on such ideas as laser transitions, single atoms, and atom cooling. The applicability of some of these new techniques to existing standards is examined.

Wineland, D. J.↗

UTC Dissemination to the Real-Time User

The current definition of Coordinated Universal Time (UTC) dates from 1972. The duration of a UTC second is defined in terms of the frequency of a hyperfine transition in the ground state of cesium. This standard frequency is realized in a number of different laboratories using ensembles of commercial cesium clocks and a few primary frequency standards. The data from all of these devices are transmitted periodically to the Bureau International des Poids et Mesures (BIPM) in Sevres, France, where they are combined in a statistical procedure to produce International Atomic Time (TAI). The time of this scale is adjusted as needed ('coordinated') by adding or dropping integer seconds so as to keep it within plus or minus 0.9 s of UT1, a time scale based on the observation of the transit times of stars and corrected for the predicted seasonal variations in these observations. When the leap seconds are included into TAI, the result is called UTC. The difference between TAI and UTC is therefore an exact integer number of seconds. This difference is currently 29 s and will become 30 s at 0 UTC on 1 January 1996.

Levine, Judah↗

Hydrogen Maser Clock (HMC) Experiment

The Hydrogen Maser Clock (HMC) project was originally conceived to fly on a reflight of the European Space Agency (ESA) free flying platform, the European Recoverable Carrier (EURECA) that had been launched into space and recovered by NASA's Space Transportation System (STS). A Phase B study for operation of HMC as one of the twelve EURECA payload components was begun in July 1991, and completed a year later. Phase C/D of HMC began in August 1992 and continued into early 1995. At that time ESA decided not to refly EURECA, leaving HMC without access to space. Approximately 80% of the flight support electronics are presently operating the HMC's physics package in a vacuum tank at the Smithsonian Astrophysical Observatory, and are now considered to be well-tested flight electronics. The package will continue to be operated until the end of 1997 or until a flight opportunity becomes avaiable. Appendices: letters and trip report; proceedings of the symposium on frequency standards and metrology; milli-celsius-stability thermal control for an orbiting frequency standard.

Vessot, Robert F. C.↗

A potential new test for unseen matter in the outer solar system

The recent development of trapped-ion frequency standards, which offer high stability over long time periods, provides us with a potential new method for detecting unseen matter in the outer solar system. A distribution of matter or a planetary body could produce a measurable gravitational redshift of the radio signal received from a spacecraft equipped with an ultrastable frequency standard. Trapped-ion standards have a potential frequency stability of 1 part in 10(exp 16) or better over long time periods (greater than 10(exp 6) s). We consider the potential improvements this method could yield over conventional dynamical tests for unseen matter in the outer solar system possible now or anticipated in the near future.

Krisher, Timothy P.↗

NASA atomic hydrogen standards program: An update

Comparisons are made between the NP series and the NX series of hydrogen masers. A field operable hydrogen maser (NR series) is also described. Atomic hydrogen primary frequency standards are in development stages. Standards are being developed for a hydrogen beam frequency standard and for a concertina hydrogen maser.

Reinhardt, V. S.↗

Atomic Clock Based On Linear Ion Trap

Highly stable atomic clock based on excitation and measurement of hyperfine transition in 199Hg+ ions confined in linear quadrupole trap by radio-frequency and static electric fields. Configuration increases stability of clock by enabling use of enough ions to obtain adequate signal while reducing non-thermal component of motion of ions in trapping field, reducing second-order Doppler shift of hyperfine transition. Features described in NPO-17758 "Linear Ion Trap for Atomic Clock." Frequency standard based on hyperfine transition described in NPO-17456, "Trapped-Mercury-Ion Frequency Standard."

Prestage, John D.↗

The Rubidium-Crystal Oscillator Hybrid Development Program

The rubidium-crystal oscillator hybrid (RbXO) will make precise time available to systems that lack the power required by atomic frequency standards. The RbXO consists of two subassemblies in separate enclosures. One contains a small rubidium frequency standard (RFS) without its internal oven-controlled crystal oscillator (OCXO), plus interface circuits. The second contains a low-power OCXO, and additional interface circuits. The OCXO is on continuously. Periodically, e.g., once a week, the user system applies power to the RFS. After the few necessary for the warmup of the RFS, the interface circuits adjust the frequency of the OCXO to the RFS reference, then shut off the RFS. The OCXO enclosure is separable from the RFS enclosure so that manpacks will be able to operate with minimum size, weight, and power consumption, while having the accuracy of the RFS for the duration of a mission. A prototype RbXO's RFS has operated successfully for 4200 on-off cycles. Parallel efforts on a Phase 2 RbXO development are in progress. Two sources for the RbXO are scheduled to be available during 1986.

Vig, J. R.↗

Fiber optic reference frequency distribution to remote beam waveguide antennas

In the NASA/JPL Deep Space Network (DSN), radio science experiments (probing outer planet atmospheres, rings, gravitational waves, etc.) and very long-base interferometry (VLBI) require ultra-stable, low phase noise reference frequency signals at the user locations. Typical locations for radio science/VLBI exciters and down-converters are the cone areas of the 34 m high efficiency antennas or the 70 m antennas, located several hundred meters from the reference frequency standards. Over the past three years, fiber optic distribution links have replaced coaxial cable distribution for reference frequencies to these antenna sites. Optical fibers are the preferred medium for distribution because of their low attenuation, immunity to EMI/IWI, and temperature stability. A new network of Beam Waveguide (BWG) antennas presently under construction in the DSN requires hydrogen maser stability at tens of kilometers distance from the frequency standards central location. The topic of this paper is the design and implementation of an optical fiber distribution link which provides ultra-stable reference frequencies to users at a remote BWG antenna. The temperature profile from the earth's surface to a depth of six feet over a time period of six months was used to optimize the placement of the fiber optic cables. In-situ evaluation of the fiber optic link performance indicates Allan deviation on the order of parts in 10(exp -15) at 1000 and 10,000 seconds averaging time; thus, the link stability degradation due to environmental conditions still preserves hydrogen maser stability at the user locations. This paper reports on the implementation of optical fibers and electro-optic devices for distributing very stable, low phase noise reference signals to remote BWG antenna locations. Allan deviation and phase noise test results for a 16 km fiber optic distribution link are presented in the paper.

Calhoun, Malcolm↗

Composite oscillator systems for meeting user needs for time and frequency

Frequency standards are used in most navigation and telecommunications systems to provide a long term memory of either frequency, phase, or time epoch. From a systems point of view, the performance aspects of the frequency standard are weighed against other systems characteristics, such as overall performance, cost, size, and accessibility; a number of examples are very briefly reviewed. The theory of phase lock and frequency lock systems is outlined in sufficient detail that total oscillator system performance can be predicted from measurements on the individual components. As an example, details of the performance of a high spectral purity oscillator phase locked to a long term stable oscillator are given. Results for several systems, including the best system stability that can be obtained from present commercially available 5-MHz sources, are shown.

Stein, S. R.↗

Stability and noise spectra of relative Loran-C frequency comparisons

Relative comparisons of Loran-C frequency transmissions between the master station of Catanzaro (Simeri Crichi) and the X, Z slave stations of Estartit (Spain) and Lampedusa (Italy) are carrying out by the GG LORSTA monitor station of the Mediterranean Sea Loran-C chain. These comparisons are able to emphasize the relative and, under certain conditions, the absolute rate of the emitting standard frequencies of the slave stations and some relevant statistical properties of the Loran-C Method for frequency transmission and time synchronization. The stability of each Loran-C frequency standard transmission is subject to perturbations, more or less known, due to the propagation medium and other causes. Following the Allan (1966) method for data processing, the performance of the relative rate of frequency of the transmissions of the X, Z slave stations are described calculating the standard deviation of a set of N frequency measurements from its mean averaged during sampling times. This standard deviation is designated as the measure of the stability of the Loran-C frequency transmission.

Proverbio, E.↗

Hydrogen masers and cesium fountains at NRC

The NRC masers H-3 and H-4 have been operating since June 1993 with cavity servo control. These low-flux active H masers are showing stabilities of about 10(exp -15) from 1 hour to several days. Stability results are presented, and the current and planned uses of the masers are discussed. A cesium fountain primary frequency standard project has been started at NRC. Trapping and launching experiments with the goal of 7 m/s launches are beginning. We discuss our plans for a local oscillator and servo that exploit the pulsed aspect of cesium fountain standards, and meet the challenge of 10(exp -14) tau(exp -1/2) stability without requiring masers. At best, we expect to run this frequency standard initially for periods of hours each working day rather than continuously for years, and so frequency transfer to outside laboratories has been carefully considered. We conclude that masers (or other even better secondary clocks) are required to exploit this potential accuracy of the cesium fountain. We present and discuss our conclusion that it is feasible to transfer frequency in this way with a transfer-induced uncertainty of less than 10(exp -15), even in the presence of maser frequency drift and random walk noise.

Boulanger, J.-S.↗

Environmental Effects on the Stability of Optical Fibers Used for Reference Frequency Distribution

The frequency Standards Laboratory at the Jet Propulsion Laboratory (JPL) is responsible for the generation and distribution of ultra-stabel reference frequencies in NASA's Deep Space Network (DSN).Certain assemblies and components of the Radio Science and VLBI systems are located in the cones of tracking antennas hundreds of meters from the Frequency and Timing Subsystem's frequency standards.

Environmental Effects↗

Time transfer via satellite-link radio interferometry

Very long baseline interferometry using natural radio sources was investigated as a possible time transfer method. Antennas were linked using a synchronous communications satellite instead of the customary independent frequency standards and tape recorders. A successful preliminary time transfer was performed using a wideband data link that was accurate at the 100 nanosecond level, and frequency standards were compared to a part in 10 to the minus thirteenth power over a 24 hour period using a phase coherent satellite link. The narrow band phase coherent link method is potentially capable of timing accuracy of 10 picoseconds, and frequency comparison accuracy of 10 to the minus sixteenth power, and is in addition economical of spectrum usage.

Knowles, S. H.↗

An error budget for the JPL hydrogen maser receiver

The hydrogen maser receiver is a synthesizer that converts the maser signal, at about 1420 MHz, to a set of output signals at 100, 20, 10, 5, 1, and 0.1 MHz. The contribution of the receiver and its component modules to the frequency instability and phase noise of each of its outputs is estimated, and these results are compared to published measurements of the 100-MHz output of the frequency standard, which consists of a maser plus its receiver. One can then assess how much the receiver degrades the performance of the frequency standard.

Greenhall, C. A.↗

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan↗

External bulb variable volume maser

A maser functioning as a frequency standard stable to one part in 10 to the 14th power includes a variable volume, constant surface area storage bulb having a fixed volume portion located in a resonant cavity from which the frequency standard is derived. A variable volume portion of the bulb, exterior to the resonant cavity, has a maximum volume on the same order of magnitude as the fixed volume bulb portion. The cavity has a length to radius ratio of at least 3:1 so that the operation is attained without the need for a feedback loop. A baffle plate, between the fixed and variable volume bulb portions, includes apertures for enabling hydrogen atoms to pass between the two bulb portions and is an electromagnetic shield that prevents coupling of the electromagnetic field of the cavity into the variable volume bulb portion.

Reinhardt, V. S.↗

(abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3

An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.

optical fiber precision time standards frequency r↗