Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Low-angle normal faults-low differential stress at mid crustal levels

A simple model for frictional slip on pre-existing faults that considers the local stress state near the fault and the effect of non-hydrostatic fluid pressures predicts that low-angle normal faulting is restricted to areas of the crust characterized by low differential stress and nearly lithostatic fluid pressures. The model considers frictional slip on a cohesionless low-angle normal fault governed by the failure criterion tau = mu sub f (sigma (*) sub n) =mu sub f (sigma sub n - P sub f) where tau and sigma sub n are the shear and normal stresses across the fault plane, mu sub f is the static coefficient of friction, and P sub f is the pore fluid pressure. As a first approximation, the model considers a vertical greatest principal compressive stress, sigma sub 1. It is apparent that if slip on low-angle normal faults is governed by the avove frictional failure criterion, slip on the low-angle normal fault occurs only if the least effective principal stress, sigma (*) sub 3 = sigma sub 3 - P sub f, is tensile, whenever tan superscrip -1(mu sub f d, where d is the dip of the fault. If detachment faulting occurs at any significant depth in the crust, P sub f sigma sub 3 is required. In light of this conclusion I allow P sub f to vary as necessary to allow slip on the low-angle normal fault.

Power, W. L.↗

Identification and interpretation of tectonic features from ERTS-1 imagery

The author has identified the following significant results. ERTS-1 imagery shows that the southern segment of the San Gabriel fault which controls the west fork of the San Gabriel River is strikingly similar to the Mill Creek Fault in the San Bernardino Mountains. It has also been noted that there is a similarity between the Sierra Madre thrust zone of the San Gabriel Mountains to the Banning thrust of the San Bernardino Mountains. This suggests that the southern San Gabriel fault was once continuous with the Mill Creek fault. When the San Bernardino Mountain block is theoretically moved to the northwest along the San Jacinto fault so that the Mill Creek fault is aligned with the southern part of the San Gabriel fault, it was found that the four transverse fault segments become aligned with the Pinto Fault on the east and with the Raymond-Santa Monica Malibu Fault zone on the west. The reconstruction identifies a continuous zone of transverse faulting extending from the Colorado River Desert to the Pacific. It seems likely that the entire fault zone was once a continuous left-lateral shear. This Anacapa Shear has probably been subjected to a 50 km left lateral movement. This analysis strongly indicates that the tectonic history of the Transverse Range has been characterized by left lateral shear on transverse faults and right lateral shear on the San Andreas fault system.

Abdel-Gawad, M.↗

CO2 Push-Pull Dual (Conjugate) Faults Injection Simulations

This submission contains datasets and a final manuscript associated with a project simulating carbon dioxide push-pull into a conjugate fault system modeled after Dixie Valley- sensitivity analysis of significant parameters and uncertainty prediction by data-worth analysis. Datasets include: (1) Forward simulation runs of standard cases (push & pull phases), (2) Local sensitivity analyses (push & pull phases), and (3) Data-worth analysis (push & pull phases).

15 GEOTHERMAL ENERGY↗

Relationships between fault characteristics and seismic responses in a large lab-scale tri-axial injection test conducted on a faulted Castlegate Sandstone

Here to investigate mechanisms causing microseismicity (M w < 2) at a CO 2 injection site, a large-scale triaxial block experiment was carried out on a faulted (saw-cut) cubic-meter of Castlegate Sandstone. The experiment consisted of injection tests at varying differential stresses, while monitoring and recording pore pressure and acoustic emissions (AEs). During the experiment, ~33,000 AEs and ~14 mm of horizontal displacement/slip, like a strike-slip fault movement, occurred. To understand the AE responses and ascertain fault characteristics near the located AEs, we modeled the topography of the fault surface, fault aperture, and fault-gouge thickness using pre- and post-experiment laser scans of the fault surface on each half of the block. Additionally, we characterized surface roughness parallel and perpendicular to slip. Models show crushing and flattening of the fault surfaces can be linked to the spatiotemporal distribution of AEs within 50 mm of the fault surface. Approximately 65% of AEs were in areas with small aperture (≤300 μm); thicker fault gouge was observed in adjacent areas with wider aperture and shows a two-fold reduction in grain size relative to unaltered Castlegate Sandstone. This work provides a conceptual understanding on fault surface evolution, which can be applied towards modeling of seismic slip.

58 GEOSCIENCES↗

Direct observations of crystal defects in polycrystalline diamond

Highlights: • Electron channeling contrast imaging of crystal defects in polycrystalline diamond • Introducing acid etching as a novel protocol for diamond surface preparation • Characterization of {111} twins, {111} stacking faults and {111} helical dislocations in diamond using ECCI and EBSD - Abstract: Crystal defects are abundant in synthetic diamond produced by chemical vapor deposition (CVD). We present the first images of crystal defects in a bulk polycrystalline CVD diamond sample using general electron channeling contrast imaging (ECCI) in a field emission scanning electron microscope (FE-SEM). For enhancement of channeling contrast of this material, we introduce a novel protocol for diamond surface preparation that involves acid etching. Using this protocol, we imaged three types of crystal defects including twins, stacking faults and dislocations. Each defect was identified based on its appearance in electron channeling contrast (ECC) micrographs. We analyzed grains containing twins and dislocations using electron backscatter diffraction (EBSD) crystal orientation mapping. We found a large population of grains that contained Σ3 type twins on {111} planes with a 60°<111> angle–axis pair of misorientation for twin boundaries. In addition, we identified {111} stacking faults and {111} helical dislocations. These observations are in agreement with reports of crystal defects in CVD diamond thin foils studied by a transmission electron microscope (TEM).

36 MATERIALS SCIENCE↗

Fault tolerant filtering and fault detection for quantum systems driven by fields in single photon states

The purpose of this paper is to solve the fault tolerant filtering and fault detection problem for a class of open quantum systems driven by a continuous-mode bosonic input field in single photon states when the systems are subject to stochastic faults. Optimal estimates of both the system observables and the fault process are simultaneously calculated and characterized by a set of coupled recursive quantum stochastic differential equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AK112: Full Waveform Inversion Tomography of Alaska Improves Waveform Fits While Imaging Crustal, Mantle, and Slab Structure

We report a full waveform inversion tomography model of Alaska and the surrounding regions, inferring radially anisotropic shear and isotropic compressional wavespeeds by fitting complete waveforms from 120 regional earthquakes. Our multiscale approach inverted time–frequency phase misfits (maximum period of 100 s), starting with a minimum period of 40 s and ending at 20 s in 7 stages and 112 total iterations. The model (AK112) was evaluated by computing the misfits for 36 independent validation events. We find that misfit reductions were large and equal (∼55%) for both the inversion and validation data sets, providing confidence in the model. AK112 also provides much better waveform fits compared to other reported models for the region, including an isotropic version of itself, highlighting the importance of anisotropy. The model resolves known crustal, upper mantle, and slab structure to depths of 100 km with new detail: sedimentary basins in the Alaskan Shelf, Cook Inlet, and Colville basins, among others; discontinuous lithospheric structure across major terrane boundaries; and subducting slab geometry and back‐arc volcanic sources. In addition to tectonic interpretations, the model enables full waveform simulations for long‐period earthquake ground motions and source characterization (e.g., moment tensor and finite‐fault inversion).

Rodgers, Arthur [Lawrence Livermore National Labor↗

Feasibility of Enhanced Geothermal Systems (EGS) Development at Bradys Hot Springs, Nevada

The Bradys EGS project focused on utilizing EGS technology to improve permeability in an existing non-productive well (15-12 ST1, located on BLM land) at Ormat’s Bradys geothermal facility in Churchill County, Nevada. The Bradys geothermal field is located within the Hot Springs Mountains, approximately 50 miles northeast of Reno, NV, along the western boundary of a very large intermontane basin known as the Carson Sink. It is one of several producing geothermal areas in the region; the Desert Peak, Stillwater, Soda Lake, and Salt Wells geothermal projects also lie within the Carson Sink, which is a region of high heat flow characterized by prominent NNE-striking faults that have formed in response to regional extension within the Basin and Range geologic province.

15 GEOTHERMAL ENERGY↗

The use of programmable logic controllers (PLC) for rocket engine component testing

Application of PLCs to the rocket engine component testing at a new Stennis Space Center Component Test Facility is suggested as an alternative to dedicated specialized computers. The PLC systems are characterized by rugged design, intuitive software, fault tolerance, flexibility, multiple end device options, networking capability, and built-in diagnostics. A distributed PLC-based system is projected to be used for testing LH2/LOx turbopumps required for the ALS/NLS rocket engines.

Nail, William↗

Characterizing the Impact of Soft Errors Affecting Floating-point ALUs using RTL-level Fault Injection

Strategies to detect, correct, or mitigate the impact of soft errors rely on errors-injection experiments. For efficient evaluation, such experiments typically inject errors in software by sampling errors from a candidate distribution. Most often, these strategies randomly select and flip one bit in the output of an instruction. While single-bit flips might constitute a meaningful model for errors affecting hardware, the appropriateness of this model for software-based errors has not been studied. In this paper, we study the manifestation of errors in the output registers due to errors affecting candidate instructions executed by floating point ALUs. We inject single-bit flips into the RTL descriptions of floating point ALUs and analyze the differences between anticipated and observed outputs when executing floating-point addition, subtraction, multiplication, and division. We choose the operands for these instructions randomly and from operands observed in five benchmarks. We observe a rich distribution of errors in the output and analyze their implications for software-based fault-injection campaigns.

Subasi, Omer↗

Thermal regimes in the detachment fault environment as deduced from fluid inclusions

Extensional tectonism, which dominates middle- and late-Tertiary geology in western Arizona, southeastern California, and southern Nevada, is characterized by normal regionally extensive, low-angle detachment faults. The decollement movement of Fupper plate rocks relative to lower plate assemblages created extensive zones of dilatency, including synthetic and antithetic listric normal faults, tear faults, tectonic crush breccias, shatter breccias, and gash veins in lithologic units above and below the detachment. The tectonically enhanced permeability above and below the detachment fault permitted mass migration of large volumes of hydrothermal solutions along the fault zone during and following upper plate movement. Major quantities of MgO, CaO, K2O, FeO/Fe2O3, SiO2 and CO2 were added to rocks in and near the detachment and related structures. Also introduced were varying amounts of trace elements including Mn, Cu, S, Mo, Ba, Au, Pb, Zn, U and/or Ag. Minerals containing fluid incusions were collected from all of these loci at locations in detachment faulted terranes in western Arizona and southeastern California.

Beane, R. E.↗

The conservativeness of reliability estimates based on instantaneous coverage

Reliability modeling must take into account two different types of phenomena, including the fault-occurrence behavior and the fault/error-handling behavior of a system. The effectiveness of the fault/error-handling behavior can be captured by instantaneous coverage probabilities. This paper has the objective to show that the assumption of instantaneous coverage leads to conservative predictions of system reliability for systems characterized by relatively long interevent times for fault occurrences and relatively short interevent times for fault/error-handling actions. The importance of this result is related to the fact that it can now be shown that model predictions based on instantaneous coverage are lower bounds on the true system reliability. Attention is given to a semi-Markov reliability model, instantaneous coverage approximations, the proof of conservative prediction, and the computation of coverage probabilities.

Mcgough, J.↗

Probing the Damage Zone at Parkfield

Rocks are heterogeneous materials that exhibit nonlinear elastic (anelastic) behavior at scales ranging from the laboratory to Earth. In the laboratory, typical, complex relationships exist between stress and strain that include hysteresis, finite relaxation times, strain rate, and history dependence. These behaviors are linked to important characteristics such as stress, porosity, permeability, material integrity, and material failure. In this work, we adopted a “pump-probe” type experiment common in laboratory studies, using solid earth tides as the low-frequency pump and empirical Green's function as the high-frequency probe. By probing the velocity at different points in the pump cycle, we constrained important information about the strain-modulus relationship. Near the San Andreas Fault, we observed strongly nonlinear elastic behavior that characterizes the damage zone. We also constrained important aspects of hysteretic behavior that are related to damage properties and possibly pore pressure. Away from the fault, the nonlinear behavior is diminished.

58 GEOSCIENCES↗

Cenozoic thermal, mechanical and tectonic evolution of the Rio Grande rift

Two areas of New Mexico which exhibit complex but similar Cenozoic histories of extensional tectonism are analyzed. The first study area is the Basin and Range province and southern Rio Gande rift in southern New Mexico; the second study area is the central Rio Grande rift in central and northern New Mexico, the southern San Luis basin, the Espanola basin, and the Albuquerque basin. Two phases of extension were identified: the first phase which began in mid-Oligocene was characterized by local high-strain extension events, low-angle faulting, and the development of broad, shallow basins, all indicating an approximately NE-SW + or - 25 deg extension direction; the later phase which occurred primarily in the late Miocene, was characterized by synchronous, high-angle faulting, resulting in large vertical strains which produced the modern Rio Grande rift morphology. Extension direction was approximately E-W. Geotherms were estimated and lithospheric strength curves were calculated for these two phases of extension. A high geotherm was deduced for the early phase resulting in a shallow crustal brittle transition, and insignificant mantle strength. The lithosphere subsequently cooled, resulting in a significant zone of mantle strength beneath the Moho. It is concluded that the interrelationship among regional and local prerifting, synrifting, and postrifting events in the Rio Grande rift attests to the fact that the rifting (in the region studied) should be considered in the context of other geologic events.

Morgan, P.↗

Analysis of Microseismicity and Reactivated Fault Size to Assess the Potential for Felt Events by CO 2 Injection in the Illinois Basin

The results of monitoring of carbon dioxide (CO 2 ) injection at the Illinois Basin—Decatur Project (IBDP) and the companion Illinois Industrial Carbon Capture and Sequestration Sources (IL-ICCS) project—have shown that reservoir response to fluid pressure changes can vary significantly at different injection locations within the same reservoir. Predrill reservoir characterization is important to identify potentially seismogenic faults. However, interpretations of newly reprocessed 3D seismic reflection data illustrate the challenges related to their identification in a region dominated by faulting with small vertical offsets. Faults interpreted in the 3D seismic volume range from ~300 to 1200 m wide and are in the same size range as faults that could have been the source of historical events up to Mw 2.7 in central Illinois. The array of monitoring sensors that was installed for the IBDP continues to collect data, as injection operates in IL-ICCS, the second injection well. CO 2 injection rates for the IL-ICCS well are on average 1.7 times the rates injected in the IBDP well, but a significantly reduced rate of induced seismicity is observed. This article presents results of passive seismic monitoring for the duration of the project to date, integrating active and passive seismic data to develop a new interpretation of the subsurface structure at the Decatur site that explicitly identifies pathways for fluid flow into the basement leading to induced seismicity, and provides a geological explanation for the sharp reduction of induced seismicity during injection at higher rates into the second well. The use of seismic moment to estimate the length of seismogenic slip planes in the local subsurface suggests that faults large enough to produce felt seismicity are unlikely to be present at or near the Decatur site.

Geochemistry & Geophysics↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗