Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber Optic Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Digital angular position sensor using wavelength division multiplexing

Future aircraft will use fly-by-light control systems with fiber-linked optical sensors for such measurands as temperature, pressure, and linear and angular position. A digital optical sensor is described which was developed to transmit the angular position of such slowly rotating parts as a throttle of fuel flow control valve on an aircraft. The sensor employs a reflective code plate with ten channels providing a resolution of 0.35 degrees. Two light-emitting diodes with overlapping spectra are used as light sources. A single microoptic multiplexer-demultiplexer composed of a GRIN rod lens and a miniature grating is used to disperse the spectrum and recombine the spectral components from each channel after reflection by the code plate. The results of preliminary environmental tests of this unit are discussed. The sensor has been operated for brief periods of time between -60 C and +125 without adverse effects. Preliminary vibration tests indicate that the unit will work properly at the maximum vibration levels expected in a jet-engine environment.

Fritsch, Klaus↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This presentation will discuss the instrumentation selected for LOFTID to capture the HIAD performance during the high-energy orbital reentry flight test, provide examples of data products, and snippets of the spectacular reentry video.

G T Swanson↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This paper will discuss the instrumentation selected for LOFTID, a summary of sensor in-flight performance, and will provide examples of data products from the post-flight analysis effort.

Gregory T Swanson↗

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This paper will discuss the instrumentation selected for LOFTID, a summary of sensor in-flight performance, and will provide examples of data products from the post-flight analysis effort.

Greg Swanson↗

Ohmic heating of composite candidate graphite-fiber/coating combinations

Graphite fibers were heated in a vacuum to test the adhesion of deposited films at elevated temperatures. Copper-clad fibers and fibers with bilayer coatings were resistance heated by a direct-current power supply. Where possible, peak temperatures were measured with a long-focal-length optical pyrometer. Fiber surface wetting or nonwetting behavior could be clearly observed after this relatively quick and simple procedure. These results are discussed in the context of creating composites of graphite fibers in a copper matrix.

Abel, Phillip B.↗

Electro-optic architecture (EOA) for sensors and actuators in aircraft propulsion systems

Results of a study to design an optimal architecture for electro-optical sensing and control in advanced aircraft and space systems are described. The propulsion full authority digital Electronic Engine Control (EEC) was the focus for the study. The recommended architecture is an on-engine EEC which contains electro-optic interface circuits for fiber-optic sensors on the engine. Size and weight are reduced by multiplexing arrays of functionally similar sensors on a pair of optical fibers to common electro-optical interfaces. The architecture contains common, multiplex interfaces to seven sensor groups: (1) self luminous sensors; (2) high temperatures; (3) low temperatures; (4) speeds and flows; (5) vibration; (6) pressures; and (7) mechanical positions. Nine distinct fiber-optic sensor types were found to provide these sensing functions: (1) continuous wave (CW) intensity modulators; (2) time division multiplexing (TDM) digital optic codeplates; (3) time division multiplexing (TDM) analog self-referenced sensors; (4) wavelength division multiplexing (WDM) digital optic code plates; (5) wavelength division multiplexing (WDM) analog self-referenced intensity modulators; (6) analog optical spectral shifters; (7) self-luminous bodies; (8) coherent optical interferometers; and (9) remote electrical sensors. The report includes the results of a trade study including engine sensor requirements, environment, the basic sensor types, and relevant evaluation criteria. These figures of merit for the candidate interface types were calculated from the data supplied by leading manufacturers of fiber-optic sensors.

Glomb, W. L., Jr.↗

Temperature Distributions in Hollow Cathode Emitters

Life-limiting processes in hollow cathodes are determined largely by the temperature of the emitter. To support development of cathode life models we have developed a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe. The probe is driven inside the hollow cathode and collects light radiated by the hot interior surface of the emitter. Ratio pyrometry is used determine the axial temperature profile. Thermocouples on the orifice plate provide measurements ofthe external temperature during cathode operation and are used to calibrate the pyrometer system in situ with a small oven enclosing the externally heated cathode. Initial measurements of the temperature distribution in a hollow cathode with the same geometry as a cathode that failed after operating at 12 A emission current for 27800 hours are discussed.

ratio pyrometer system↗

Manufacturing Precise, Lightweight Paraboloidal Mirrors

A process for fabricating a precise, diffraction- limited, ultra-lightweight, composite- material (matrix/fiber) paraboloidal telescope mirror has been devised. Unlike the traditional process of fabrication of heavier glass-based mirrors, this process involves a minimum of manual steps and subjective judgment. Instead, this process involves objectively controllable, repeatable steps; hence, this process is better suited for mass production. Other processes that have been investigated for fabrication of precise composite-material lightweight mirrors have resulted in print-through of fiber patterns onto reflecting surfaces, and have not provided adequate structural support for maintenance of stable, diffraction-limited surface figures. In contrast, this process does not result in print-through of the fiber pattern onto the reflecting surface and does provide a lightweight, rigid structure capable of maintaining a diffraction-limited surface figure in the face of changing temperature, humidity, and air pressure. The process consists mainly of the following steps: 1. A precise glass mandrel is fabricated by conventional optical grinding and polishing. 2. The mandrel is coated with a release agent and covered with layers of a carbon- fiber composite material. 3. The outer surface of the outer layer of the carbon-fiber composite material is coated with a surfactant chosen to provide for the proper flow of an epoxy resin to be applied subsequently. 4. The mandrel as thus covered is mounted on a temperature-controlled spin table. 5. The table is heated to a suitable temperature and spun at a suitable speed as the epoxy resin is poured onto the coated carbon-fiber composite material. 6. The surface figure of the optic is monitored and adjusted by use of traditional Ronchi, Focault, and interferometric optical measurement techniques while the speed of rotation and the temperature are adjusted to obtain the desired figure. The proper selection of surfactant, speed or rotation, viscosity of the epoxy, and temperature make it possible to obtain the desired diffraction-limited, smooth (1/50th wave) parabolic outer surface, suitable for reflective coating. 7. A reflective coat is applied by use of conventional coating techniques. 8. Once the final figure is set, a lightweight structural foam is applied to the rear of the optic to ensure stability of the figure.

Hermann, Frederick Thomas↗

Optical temperature sensor utilizing birefringent crystals

A temperature sensor comprising an optical transducer member having an array of birefringent crystals. The length and, accordingly, the sensitivity to temperature change of successive birefringent crystals varies according to a particular relationship. The transducer is interconnected with a fiber optic transmission and detecting system. Respective optical output signals that are transmitted from the birefringent crystals via the fiber optic transmission system are detected and decoded so as to correspond to digits of a numbering system, whereby an accurate digital representation of temperature can ultimately be provided.

Quick, William H.↗

Fiber Bragg Grating Filter High Temperature Sensors

We present a scaled-down method for determining high temperatures using fiber-based Bragg gratings. Bragg gratings are distributed along the length of the optical fiber, and have high reflectivities whenever the optical wavelength is twice the grating spacing. These spatially distinct Bragg regions (located in the core of a fiber) are sensitive to local temperature changes. Since these fibers are silica-based they are easily affected by localized changes in temperature, which results in changes to both the grating spacing and the wavelength reflectivity. We exploit the shift in wavelength reflectivity to measure the change in the local temperature. Note that the Bragg region (sensing area) is some distance away from where the temperature is being measured. This is done so that we can measure temperatures that are much higher than the damage threshold of the fiber. We do this by affixing the fiber with the Bragg sensor to a material with a well-known coefficient of thermal expansion, and model the heat gradient from the region of interest to the actual sensor. The research described in this paper will culminate in a working device as well as be the second portion of a publication pending submission to Optics Letters.

Lyons, Donald R.↗

Miniaturized fiber-optic Michelson-type interferometric sensors

A novel, miniaturized Michelson-type fiber-optic interferometric sensor that is relatively insensitive to temperature drifts is presented. A fused-biconical tapered coupler is cleaved immediately after the coupled length and polished down to the region of the fused cladding, but short of the interaction region. The end of one core is selectively coated with a reflective surface and is used as the reference arm; the other core serves as the sensing arm. The detection of surface acoustic waves, microdisplacements, and magnetic fields is reported. The sensor is shown to be highly stable in comparison to a classic homodyne, uncompensated Michelson interferometer, and signal-to-noise ratios of 65 dB have been obtained.

Murphy, Kent A.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Design, fabrication and testing of an optical temperature sensor

The laboratory breadboard optical temperature sensor based on the temperature dependent absorptive characteristics of a rare earth (europium) doped optical fiber. The principles of operation, materials characterization, fiber and optical component design, design and fabrication of an electrooptic interface unit, signal processing, and initial test results are discussed. Initial tests indicated that, after a brief warmup period, the output of the sensor was stable to approximately 1 C at room temperature or approximately + or - 0.3 percent of point (K). This exceeds the goal of 1 percent of point. Recommendations are presented for further performance improvement.

Morey, W. W.↗

Optoelectronic System Measures Distances to Multiple Targets

An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path length inside the optical fiber is not ordinarily known and can change with temperature, it is also necessary to measure the phase difference associated with this portion and subtract it from the aforementioned overall phase difference to obtain the phase difference proportional to only the free-space path length, which is the distance that one seeks to measure. Therefore, the apparatus includes a photodiode and a circulator that enable measurement of the phase difference associated with propagation from the LRU inside the fiber to the target, reflection from the fiber end, and propagation back inside the fiber to the LRU. Because this phase difference represents twice the optical path length of the fiber, this phase difference is divided in two before subtraction from the aforementioned total-path-length phase difference. Radiation-induced changes in the photodetectors in this apparatus can affect the measurements. To enable calibration for the purpose of compensation for these changes, the apparatus includes an additional target at a known short distance, located inside the camera. If the measured distance to this target changes, then the change is applied to the other targets.

Liebe, Carl Christian↗

A Fiber-Optic Probe Design for Combustion Chamber Flame Detection Applications-Design Criteria, Performance Specifications, and Fabrication Technique

This paper documents the design and development of the fiber-optic probes utilized in the flame detection systems used in NASA Langley Research Center's 8-Foot High Temperature Tunnel (8-ft HTT). Two independent flame detection systems are utilized to monitor the presence and stability of the main-burner and pilot-level flames during facility operation. Due to the harsh environment within the combustor, the successful development of a rugged and efficient fiber-optic probe was a critical milestone in the development of these flame detection systems. The final optical probe design for the two flame detection systems resulted from research that was conducted in Langley's 7-in High Temperature Pilot Tunnel (7-in HTT). A detailed description of the manufacturing process behind the optical probes used in the 8-ft HTT is provided in Appendix A of this report.

Borg, Stephen E.↗

High Temperature Calibration Furnace System user's guide

The High Temperature Calibration Furnace System (HTCFS) was developed by Summitec Corporation. It is a high precision instrument providing a constant temperature which can be used to calibrate high temperature thermocouples. Incorporating the many recent technological advances from the fields of optical fiber thermometry, material science, computer systems interfacing, and process control, the engineers at Summitec Corporation have been able to create a system that can reach a steady operating temperature of 1700 C. The precision for the system requires the measurement of temperature to be within 1 C in two hours and within 2 C in 24 hours. As documented, the experimental result shows that this system has been able to stay within .5 C in 5 hours. No other systems commercially available have been able to achieve such high temperature precision. This manual provides an overview of the system design, instructions for instrument setup, and operation procedures. Also included are a vendor list and the source codes for the custom-designed software.

Source record↗

Emitter Surface Temperature Measurements of a 25-A Class Hollow Cathode

The axial emitter surface temperature profile is experimentally characterized for a 25-A class hollow cathode operating across a range of operating conditions. Profiles were measured using aratio pyrometry diagnostic featuring a fiber optic inserted into the emitter region using a fast motion stage. Emitter temperature is found to increase with increasing discharge current, decreasing flow rate, and increasing magnetic field strength. Across a range of 10 –29 A, the maximum emitter temperature increased 176 ºC, an order of magnitude more than the changes measured for flow rate or magnetic fields strength. Profiles were generally self-similar across all operating conditions, and the difference between maximum and minimum emitter temperature never surpassed 10%, indicating that this cathode design results in satisfactory emitter utilization across its operating envelope

space propulsion↗