Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber optic distributed temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells

High Temperature insulated wire and optical fiber cable is a key enabling technology for the Geothermal Technologies Program (GTP). Without insulated electrical wires and optical fiber, downhole temperature and pressure sensors, flow meters and gauges cannot communicate with the surface. Unfortunately, there are currently no insulated electrical wire or fiber cable constructions capable of surviving for extended periods of deployment in a geothermal well (240-325°C) or supercritical (374°C) reservoir. This has severely hindered engineered reservoir creation, management and utilization, as hot zones and cool water intrusions cannot be understood over time. The lack of a insulated electrical wire and fiber cable solution is a fundamental limitation to the viability of this energy source. The High Temperature Downhole Tools target specification is development of tools and sensors for logging and monitoring wellbore conditions at depths of up to 10,000 meters and temperatures up to 374oC. It well recognized in the industry that no current electronic or fiber cable can be successfully deployed in a well and function successfully for more a few days at temperatures over 240oC. The goal of this project was to raise this performance level significantly. Prysmian Group’s objective in this project was to develop a complete, multi-purpose cable solution for long-term deployment in geothermal wells/reservoirs that can be used with the widest variety of sensors. In particular, the overall project objective was to produce a manufacturable cable design that can perform without serious degradation: • At temperatures up to 374°C; • At pressures up to 220 bar; • In a hydrogen-rich environment; and • For the life of the well (> 5 years). This cable incorporates: • Specialty optical fibers, with specific glass chemistry and high temperature and pressure protective coatings for data communication and distributed temperature and pressure sensing, and • High-temperature insulated wire conductors Prysmian Group has developed a geothermal fiber optic cable (GFOC) solution which incorporates novel glass chemistry for optical fibers to operate at the required bandwidths in high temperature/high pressure hydrogen rich environments with fiber protection, high temperature insulated conductors and protective cladding for cable components. The cable solution has been tested in a geothermal installation for 10 months. The electrical insulation and optical fibers have been validated through laboratory testing to ensure successful operation for greater than 5 years at 300°C, with the possibility of higher temperatures depending on the particular well environment. With the 300°C optical fiber and electrical insulation developments completed and validated in laboratory tests the greatest challenge to a complete 300°C cable solution was protecting the optical fibers in the cable. Optical fibers are typically incased in a protective tube where the tube is filled with a gel. The gel serves as mechanical protection, prevent moisture ingress, and can include hydrogen scavenging materials. A suitable gel for use at 300°C could not be identified and an industrialized alternative was not fully attained. Despite the problems encountered and the lower long-term operating temperature of the cable solution, the project showed success in developing a complete cable solution for a large portion of the geothermal wells in operation today. Further work to obtain the higher long-term temperature goal of the project can be achieved based on the knowledge gained in the current project. This project is significant for many reasons including the new materials science, manufacturing technology, energy independence, and jobs created and will create.

15 GEOTHERMAL ENERGY↗

Joint UAS-Balloon Activities (JUBA) Field Campaign Report

Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, the Joint UAS-Balloon Activity (JUBA) was a collaborative exercise between SNL Organizations 6533 and 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and unmanned aerial systems (UAS) on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility third ARM Mobile Facility (AMF3) site at Oliktok Point, Alaska. The Restricted Airspace occupies a two-nautical-mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 and 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability. To understand how balloon and UAS activities could occur together, JUBA activities included the following: Developing aviation safety plans for the simultaneous, collocated operation of tethered balloons and UAS Adapting tethered balloon-based fiber optic distributed temperature sensing (DTS) measurements to a UAS platform Creating solutions to technical challenges such as: Developing a motor system to match the fiber deployment rate with the ascent/descent rate of the UAS Evaluating methods of identifying the surface in the DTS temperature profile Correlating simultaneous balloon and UAS DTS temperature measurements Assessing the effects of a fiber optic rotary joint on the DTS temperature measurements Determining what UAS-based sensors provided the best calibration source for the DTS temperature data.

North Slope of Alaska, arctic processes, unmanned ↗

Real-Time Optical Fuel-to-Air Ratio Sensor for Gas Turbine Combustors

The measurement of the temporal distribution of fuel in gas turbine combustors is important in considering pollution, combustion efficiency and combustor dynamics and acoustics. Much of the previous work in measuring fuel distributions in gas turbine combustors has focused on the spatial aspect of the distribution. The temporal aspect however, has often been overlooked, even though it is just as important. In part, this is due to the challenges of applying real-time diagnostic techniques in a high pressure and high temperature environment. A simple and low-cost instrument that non-intrusively measures the real-time fuel-to-air ratio (FAR) in a gas turbine combustor has been developed. The device uses a dual wavelength laser absorption technique to measure the concentration of most hydrocarbon fuels such as jet fuel, methane, propane, etc. The device can be configured to use fiber optics to measure the local FAR inside a high pressure test rig without the need for windows. Alternatively, the device can readily be used in test rigs that have existing windows without modifications. An initial application of this instrument was to obtain time-resolved measurements of the FAR in the premixer of a lean premixed prevaporized (LPP) combustor at inlet air pressures and temperatures as high as 17 atm at 800 K, with liquid JP-8 as the fuel. Results will be presented that quantitatively show the transient nature of the local FAR inside a LPP gas turbine combustor at actual operating conditions. The high speed (kHz) time resolution of this device, combined with a rugged fiber optic delivery system, should enable the realization of a flight capable active-feedback and control system for the abatement of noise and pollutant emissions in the future. Other applications that require an in-situ and time-resolved measurement of fuel vapor concentrations should also find this device to be of use.

Nguyen, Quang-Viet↗

Time Constants for Optical Fiber Temperature Sensing using a Thermal Resistance Approach

Optical fibers are immune to electromagnetic interference, have no moving parts, no applied voltages, no special environmental conditions, and they are extremely small (100's of microns in diameter). The U.S. Department of Energy is interested in extending this technology to extremely high temperature radiation environments for the purposes of developing in-pile instrumentation for the restart of TREAT (Transient Reactor Test Facility). TREAT is an air-cooled, thermal, heterogeneous test reactor facility that was designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling conditions that may be postulated to occur in a nuclear reactor. Spatially distributed temperature measurements can be made using an Optical Backscatter Reflectometer (such as, model 4600, manufactured by Luna Innovations, Inc.), coupled to single-mode optical fiber that is placed in an in-pile nuclear reactor testing facility. In-pile temperature sensing for the TREAT reactor will need to have a fast response to temperature changes, since the reactor pulse will be on the order of 100 msec. The sensors must also be robust enough to be installed in the testing facility; this requires the fibers to be in a protective capillary tubing that is made of a tough material, such as stainless steel. The temperature response of the fiber will be delayed by the capillary tubing. This paper discusses the characterization and modeling of the thermal time constants of the sensors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal

This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoring the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber Optic Sensor Components and Systems for Smart Materials and Structures

The general objective of the funded research effort has been the development of discrete and distributed fiber sensors and fiber optic centered opto-electronic networks for the intelligent monitoring of phenomena in various aerospace structures related to NASA Marshall specific applications. In particular, we have proposed and have been developing technologies that we believe to be readily transferrable and which involve new fabrication techniques. The associated sensors developed can be incorporated into the matrix or on the surfaces of structures for the purpose of sensing stress, strain, temperature-both low and high, pressure field variations, phase changes, and the presence of various chemical constituents.

Lyons, R.↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of Ensuring the safety, integrity, and operational efficiency of underground product pipelines is vital for maintaining the nation’s critical infrastructure. Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensors—were employed to measure key parameters like hoop strain, pressure, and acoustic vibrations. The underground product pipeline's outer diameter is 30 inches, the wall thickness is 1.28 inches, and the 3-foot depth. The fiber deployment strategies, and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety.

distributed fiber sensing↗

Accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas

Purpose: To establish accuracy of real time noninvasive temperature measurements using magnetic resonance thermal imaging in patients treated for high grade extremity soft tissue sarcomas. Methods: Protocol patients with advanced extremity sarcomas were treated with external beam radiation therapy and hyperthermia. Invasive temperature measures were compared to noninvasive magnetic resonance thermal imaging (MRTI) at 1.5 T performed during hyperthermia. Volumetric temperature rise images were obtained using the proton resonance frequency shift (PRFS) technique during heating in a 140 MHz miniannular phased array applicator. MRTI temperature changes were compared to invasive measurements of temperature with a multisensor fiber optic probe inside a no. 15 g catheter in the tumor. Since the PRFS technique is sensitive to drifts in the primary imaging magnetic field, temperature change distributions were corrected automatically during treatment using temperature-stable reference materials to characterize field changes in 3D. The authors analyzed MRT images and compared, in evaluable treatments, MR-derived temperatures to invasive temperatures measured in extremity sarcomas. Small regions of interest (ROIs) were specified near each invasive sensor identified on MR images. Temperature changes in the interstitial sensors were compared to the corresponding ROI PRFS-based temperature changes over the entire treatment and over the steady-state period. Nonevaluable treatments (motion/imaging artifacts, noncorrectable drifts) were not included in the analysis. Results: The mean difference between MRTI and interstitial probe measurements was 0.91 deg. C for the entire heating time and 0.85 deg. C for the time at steady state. These values were obtained from both tumor and normal tissue ROIs. When the analysis is done on just the tumor ROIs, the mean difference for the whole power on time was 0.74 deg. C and during the period of steady state was 0.62 deg. C. Conclusions: The data show that for evaluable treatments, excellent correlation ({Delta}T<1 deg. C) of MRTI-ROI and invasive measurements can be achieved, but that motion and other artifacts are still serious challenges that must be overcome in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and development of a probe-based multiplexed multi-species absorption spectroscopy sensor for characterizing transient gas-parameter distributions in the intake systems of I.C. engines

We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2 O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuring gas temperature, pressure, and H 2 O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.

33 ADVANCED PROPULSION SYSTEMS↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗

Embedment of sensors in ceramic structures

Ceramic materials such as silicon carbide (SiC) are attractive for many nuclear applications due to their ability to withstand high temperatures, which inherently improve the thermal efficiency of the power conversion cycle and can in some cases provide high-temperature process heat. SiC is particularly attractive because of its high-temperature strength retention, stability under neutron irradiation, and low neutron absorption. The TCR program has recently demonstrated the ability to fabricate monolithic SiC components with complex geometries using a binder jet additive manufacturing technique followed by densification using chemical vapor infiltration (CVI). This technology presents an opportunity to embed sensors within ceramic components at critical locations that allow for enhanced process monitoring and control of advanced nuclear energy systems. The challenges with embedding sensors in ceramic components are to identify appropriate materials that can survive the CVI process, remain embedded after cooling to room temperature, and be suitable for operation in a high-temperature nuclear environment. This report summarizes the sensors that are being considered for embedding within ceramics, the sensor embedding process, material compatibility studies, and characterization of the embedded components. Material selection is first guided by computational thermodynamics and is confirmed by embedding coupons and examining material interactions using electron microscopy. This work shows that a wide range of refractory metals, as well as certain fiber optic sensors, can be successfully embedded in 3D-printed SiC. Future work will involve testing of functional sensors including thermocouples and optical fiber-based, spatially distributed temperature/strain sensors.

36 MATERIALS SCIENCE↗

Non-Intrusive, Distributed Gas Sensing Technology for Advanced Spacesuits

Chemical sensors for monitoring gas composition, including oxygen, humidity, carbon dioxide, and trace contaminants, are needed to characterize and validate spacesuit design and operating parameters. This paper reports on the first prototypes of a non-intrusive gas sensing technology based on flexible sensitive patches positioned inside spacesuit prototypes and interrogated via optical fibers routed outside the suit, taking advantage of the transparent materials of the suit prototypes. The sensitive patches are based on luminescent materials whose emission parameters vary with the partial pressure of a specific gas. Patches sensitive to carbon dioxide, humidity, and temperature have been developed, and their preliminary laboratory characterization in Mark III-like helmet parts is described. The first prototype system consists of a four-channel fiber optic luminescent detector that can be used to monitor any of the selected target gases at four locations. To switch from one gas to another we replace the (disposable) sensor patches and adjust the system settings. Repeatability among sensitive patches and of sensor performance from location to location has been confirmed, assuring that suit engineers will have flexibility in selecting multiple sensing points, fitting the sensor elements into the spacesuit, and easily repositioning the sensor elements as desired. The evaluation of the first prototype for monitoring carbon dioxide during washout studies in a spacesuit prototype is presented.

Delgado, Jesus↗

Embedded metallized optical fibers for high temperature applications

Embedding fiber optics in metal components could enable new capabilities such as active monitoring of spatially distributed strain. Ultrasonic additive manufacturing is a suitable technique for embedding fiber optics because it allows fibers to be embedded in metals without melting and without the use of epoxy. However, for harsh environments that could have high temperatures or high radiation doses, traditional polymer-coated fibers cannot survive for extended periods of time. This work demonstrates successful embedding of commercially available copper-, nickel-, and aluminum-coated fibers into aluminum without any observable damage to the fiber. Copper-coated fibers embedded in copper show adequate light transmission, although residual strain could not be resolved. With further processing improvements, fibers embedded in copper or other high-temperature materials could enable even higher temperature operation. Optical transmission and spatially distributed strain were measured in the fibers embedded in aluminum. Measurements were taken after embedding and during heating to temperatures greater than 500 °C. Within the embedded region, both the copper- and aluminum-coated fibers showed strain that matched the expected strain in the surrounding aluminum matrix during heating. This suggests a strong interfacial bond strength that exceeds the maximum estimated fiber strain of 1.2% (871 MPa tensile stress). Furthermore this demonstration of embedded fibers that can survive high temperatures and remain bonded to the metal matrix is the first step toward embedded fiber optic sensors for harsh environment applications.

36 MATERIALS SCIENCE↗

Embedding of Fiber Optic Sensors in Stainless Steel for Sensing in Harsh Environments

Structural health monitoring is critical for components working in harsh environments to assess their safety and integrity. This can be realized with advanced sensors, such as fiber optic sensors, embedded in these components. Recent studies have used ultrasonic consolidation (UC) and laser-based additive manufacturing (AM) techniques to embed fiber optic sensors in metals. However, sensor embedding using these techniques has been challenging, with gaps and voids around the embedded fiber. Successful embedding of fiber optic sensors requires good contact between the fiber and the matrix to eliminate potential gas/liquid leaks in critical systems such as in nuclear and aerospace services. Defect-free fiber/matrix bond is also essential for accurate measurement of parameters of interest, such as temperature and strain. This study developed a novel fiber embedding technique based on electric field-assisted sintering (EFAS). Sapphire optical fibers with diameters of 125 µm and 250 µm were embedded in stainless steel (SS) 316L using EFAS. The embedding was completed by sintering SS 316L powders at a pressure of 50MPa, hold time of 5 min, and temperatures of 1000°C, 1100°C, and 1200°C. Joule heating mechanism during EFAS enabled rapid sintering of the SS 316L powder with resulting sample densities over 99%. Microscopy analysis performed on the cross-sections revealed a defect-free bond between the embedded fiber and SS 316L. The good integrity of the embedded fiber was evidenced by optical transmittance measurement. Optical attenuation of the fiber before and after embedment was examined in the near-infrared region. Scanning electron microscopy was employed to investigate the grain morphology of SS 316L near the embedded fiber. Hardness distribution in the sintered part was also investigated to study the effect of the embedded fiber on the mechanical properties of the as-fabricated component. The results indicated that EFAS was able to embed fiber in SS with good fiber functionality and part quality.

36 - MATERIALS SCIENCE↗