Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

A software‐defined networks ‐based measurement method of network traffic for 6G technologies

Abstract In software‐defined networks (SDN) for 6G technologies, the controller should accurately and efficiently measure the flow traffic in switches for traffic engineering. Fine‐grained flow measurement can more accurately describe the traffic in the network, but it also consumes much more resources. To reduce the overhead incurred in the measurement process and obtain the approximate fine‐grained measurements, we propose a novel lightweight measurement scheme that runs in the controller. The novel lightweight measurement architecture consists of two parts: coarse‐grained measurement and interpolation‐optimization. In the first part, based on the SDN architecture, we use the pull‐based random sampling method to quickly obtain the coarse‐grained measurement of flow traffic through OpenFlow protocol. In the second part, we insert some discrete values into the coarse‐grained measurement with the interpolation theory, then we optimize interpolation results until finding the optimal fine‐grained flow traffic measurement by utilizing the multiconstraint method. We verified the feasibility of the proposed measurement method, and simulation results show that the measurement error of the proposed method is under 25%, but the flow measurement overhead of this method occupies only 3.3% compared with that of the fine‐grained method.

Huo, Liuwei↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Flow Angularity Measurements in the NASA-Langley Transonic Dynamics Tunnel

An investigation using a survey rake with 11 five-hole pyramid-head probes has been conducted in the Langley Transonic Dynamics Tunnel (TDT) to measure the test section flow angularity. Flow measurements were made in a 10-ft square grid centered about the test section centerline at a single streamwise location for nine Mach numbers ranging from 0.50 to 1.19 at dynamic pressures of 100 and 225 pounds per square foot. Test section flow angularity was found to be minimal with a generally random flow pattern. Corrections for survey rake induced in-plane flow were determined to be necessary; however, corrections for rake induced lift effects were not required.

Yeager, William T., Jr.↗

Improved Ultrasonic Transducer For Measuring Cryogenic Flow

Improved ultrasonic transducer used to measure flow of cryogenic fluid. Includes wedge made nonintrusive by machining it out of bulk material of duct carrying fluid. Skewed surfaces of wedge suppress standing waves, thus reducing ringing and increasing signal-to-noise ratio. Increases accuracy of measurements of times of arrival of ultrasonic pulses, from which times flow inferred.

Barkhoudarian, Sarkis↗

Measurements of flow quality in the Ames 2 x 2ft transonic wind tunnel

For decades, wind tunnel testing has been conducted in test section environments which have not been adequately documented. However, with the advent of the energy shortage, the need for improved fuel-efficient transports employing supercritical or LFC airfoils has increased the awareness of the possible influence of freestream turbulence on advanced experimental testing. This has already lead to detailed flow quality measurements in NASA transonic wind tunnels. The purpose of this paper is to present results of a study in the Ames 2 x 2 ft transonic wind tunnel.

Owen, F. K.↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Disturbance Measurements in the National Transonic Facility

Recent flow measurements have been acquired in the National Transonic Facility to assess the test-section unsteady flow environment. The primary purpose of the test is to determine the feasibility of the facility to conduct laminar-flow-control testing and boundary-layer transition-sensitive testing at flight-relevant operating conditions throughout the transonic Mach number range. The facility can operate in two modes, warm and cryogenic test conditions for testing full and semispan-scaled models. Data were acquired for Mach and unit Reynolds numbers ranging from 0.2 less than or equal to M less than or equal to 0.95 and 3.3 × 10(exp 6) less than Re/m less than 220×10(exp 6) collectively at air and cryogenic conditions. Measurements were made in the test section using a survey rake that was populated with 19 probes. Roll polar data at selected conditions were obtained to look at the uniformity of the flow disturbance field in the test section. Data acquired included mean total temperatures, mean and fluctuating static/total pressures, and mean and fluctuating hot-wire measurements. This paper focuses primarily on the unsteady pressure and hot-wire results. Based on the current measurements and previous data, an assessment was made that the facility may be a suitable facility for ground-based demonstrations of laminar-flow technologies at flight-relevant conditions in the cryogenic mode.

King, Rudolph A.↗

Manometer Measures Gas Flow

Simple apparatus measures time required for gas to displace known volume of water. Apparatus determines amount of gas generated in lead/acid cell during charging by measuring time required for gas to displace measured volume of water between markes in slanted manometer.

Rowlette, J. J.↗

Characteristics of dilute gas-solids suspensions in drag reducing flow

Measurements were performed on dilute flowing gas-solids suspensions and included data, with particles present, on gas friction factors, velocity profiles, turbulence intensity profiles, turbulent spectra, and particle velocity profiles. Glass beads of 10 to 60 micron diameter were suspended in air at Reynolds numbers of 10,000 to 25,000 and solids loading ratios from 0 to 4. Drag reduction was achieved for all particle sizes in vertical flow and for the smaller particle sizes in horizontal flow. The profile measurements in the vertical tube indicated that the presence of particles thickened the viscous sublayer. A quantitative theory based on particle-eddy interaction and viscous sublayer thickening has been proposed.

Kane, R. S.↗

In-situ thermophysical measurement of flowing molten chloride salt using modulated photothermal radiometry

Molten salts are leading candidates for high-temperature heat transfer fluids (HTFs) for thermal energy storage and conversion systems in concentrated solar power (CSP) and nuclear energy power plants. The ability to probe molten salt thermal transport properties in both stationary and flowing status is important for the evaluation of their heat transfer performance under realistic operational conditions, including the temperature range and potential degradation due to corrosion and contamination. However, accurate thermal transport properties are usually challenging to obtain even for stagnant molten salts due to different sources of errors from convection, radiation, and corrosion, let alone at flowing status. To the best of authors’ knowledge, there is no available in-situ technique for measuring flowing molten salt thermal conductivity. Here, we report the first in-situ flowing molten salt thermal conductivity measurement using modulated photothermal radiometry (MPR). We could successfully perform the first in-situ thermal conductivity measurement of flowing molten NaCl-KCl-MgCl 2 in the typical operating temperature (520 and 580 °C) with flow velocities ranging from around 0.3 to 1.0 m s -1 . The relative change of the molten salt thermal conductivity was measured. Gnielinski’s correlation was also used to estimate the heat transfer coefficient h of the flowing NaCl-KCl-MgCl 2 in the given experimental condition. Furthermore, the work showed the potential of the MPR technique serving as an in-situ diagnostics tool to evaluate the heat transfer performance of flowing molten salts and other high-temperature HTFs.

14 SOLAR ENERGY↗

Measurement of Flow Angularity at Supersonic and Hypersonic Speeds with the Use of a Conical Probe

The characteristics of a 40 deg half-angle cone for measuring flow angularity were determined experimentally. Tests were conducted at a Mach number of 21 in helium with check points at Mach number 3.55 in air for angles of pitch up to 5 deg. The air tests confirmed theoretical indications of small or negligible Mach number and test-medium effects for the case of air and helium. The instrument is capable of measuring flow angularity at high Reynolds numbers and speeds greater than that necessary for shock attachment to within (+/-)1/3 deg.

Swalley, Frank E.↗

Flow Field Measurements in a 3-D Separating Flow

A combined experimental and computational effort to test the performance of turbulence models in prediction of three-dimensional separation is under way. The current phase pf the project is the acquisition of flow field data using laser Doppler velocimetry. Accomplishments for summer 1996 include development of the instrument and signal processing system and acquisition of mean velocity profiles.

Compton, Debora A.↗

Dynamic Pressure Probes Developed for Supersonic Flow-Field Measurements

A series of dynamic flow-field pressure probes were developed for use in large-scale supersonic wind tunnels at the NASA Glenn Research Center. These flow-field probes include pitot and static pressure probes that can capture fast-acting flow-field pressure transients occurring on a millisecond timescale. The pitot and static probes can be used to determine local Mach number time histories during a transient event. The flow-field pressure probe contains four major components: 1) Static pressure aerodynamic tip; 2) Pressure-sensing cartridge assembly; 3) Pitot pressure aerodynamic tip; 4) Mounting stem. This modular design allows for a variety of probe tips to be used for a specific application. Here, the focus is on flow-field pressure measurements in supersonic flows, so we developed a cone-cylinder static pressure tip and a pitot pressure tip. Alternatively, probe tips optimized for subsonic and transonic flows could be used with this design. The pressure-sensing cartridge assembly allows the simultaneous measurement of steady-state and transient pressure which allows continuous calibration of the dynamic pressure transducer.

Porro, A. Robert↗