Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focuses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analysis of Stierwalt out-of-band transmission scattering effect for dual infrared filters serially positioned at a focus

Some remote sounding applications require utilization of interference filters with very high out-of-band rejection (OBR) performance. In this paper, the advantages to be gained in achieving high OBR by the use of two serially ganged interference filters mounted in a wedge configuration near a focus are discussed. Degradation of OBR due to scattering effects is examined, and a quantitative technique to estimate such effects in dual wedged filters mounted at a focus is presented. An approach to the design of filter elements to be used in the dual wedged configuration is given that accounts for scatter. An application of this design approach to the CLAES 10.81 micron filter is described.

Kumer, J. B.↗

Focus of attention in systems for visual monitoring of experiments

The problem of designing a computerized experiment monitoring system for use in a space station or elsewhere is examined. It is shown that the essential challenge of such a system - attaining a reasonable expected running time - can be attacked using the concept of focus of attention and by exploiting parallelism. The use of the Contract Net Protocol for the latter purpose is discussed. The use of ideas from information science to help focus a programs's efforts on those computations likely to bring results is addressed, and the incorporation of those ideas into a design in order to aid the system in deciding upon the best course of action is considered.

Blank, G. E.↗

Hormone purification by isoelectric focusing in space

The objective of the program was the definition and development of optimal methods for electrophoretic separations in microgravity. The approach is based on a triad consisting of ground based experiments, mathematical modeling and experiments in microgravity. Zone electrophoresis is a rate process, where separation is achieved in uniform buffers on the basis of differences in electrophoretic mobilities. Optimization and modeling of continuous flow electrophoresis mainly concern the hydrodynamics of the flow process, including gravity dependent fluid convection due to density gradients and gravity independent electroosmosis. Optimization of focusing requires a more complex model describing the molecular transport processes involved in electrophoresis of interacting systems. Three different focusing instruments were designed, embodying novel principles of fluid stabilization. Fluid stability was achieved by: (1) flow streamlining by means of membrane elements in combination with rapid fluid recycling; (2) apparatus rotation in combination with said membrane elements; and (3) shear stress induced by rapid recycling through a narrow gap channel.

Bier, M.↗

DBR laser with nondynamic plasma grating formed by focused ion beam implanted dopants

A static plasma grating has been demonstrated experimentally (Wu et al., 1988) in a large-optical-cavity focused-ion-beam-distributed-Bragg-reflector (FIB-DBR) GaAlAs/GaAs laser diode. The grating is formed by implanting stripes of dopants with a focused ion beam. The dopants ionize to form periodic fluctuations in the carrier concentration which, through the Kramers-Kronig relations, form an index grating. A model of the grating strength for optimizaton of the laser design is developed and presented. The computed results show that the coupling coefficient k can be increased by more than an order of magnitude over the 15/cm experimentally. Therefore, FIB-DBR or FIB-distributed-feedback (DFB) lasers with performance comparable to that of conventional DBR (or DFB) lasers can be expected.

Boenke, Myra M.↗

An improved large-field focusing schlieren system

The analysis and performance of a high-brightness large-field focusing schlieren system is described. The system can be used to examine complex two- and three-dimensional flows. Techniques are described to obtain focusing schlieren through distorting optical elements, to use multiple colors in a time multiplexing technique, and to use diffuse screen holography for three-dimensional photographs.

Weinstein, Leonard M.↗

Instrument Measures Shift In Focus

Optical components tested at wavelengths from ultraviolet to infrared. Focus-shift-measuring instrument easy to use. Operated in lighted room, without having to make delicate adjustments while peering through microscope. Measures distance along which focal point of converging beam of light shifted by introduction of nominally plane parallel optical component into beam. Intended primarily for measuring focus shifts produced by windows and filters at wavelengths from 120 to 1,100 nanometers. Portable, compact, and relatively inexpensive for degree of precision.

Steimle, Lawrence J.↗

Effects of beam focusing on the efficiency of planar waveguide grating couplers

Results of a theoretical and experimental study into the variation of coupling efficiency with a grating angle are presented for various beam focusing conditions for an integrated optical grating coupler. The study shows that the acceptance angle of the grating coupler can be broadened within a relatively large range and with a relatively small loss of coupling efficiency, by focusing the incident laser beam.

Li, Lifeng↗

Improved Large-Field Focusing Schlieren System

System used to examine complicated two- and three-dimensional flows. High-brightness large-field focusing schlieren system incorporates Fresnel lens instead of glass diffuser. In system with large field of view, image may also be very large. Relay optical subsystem minifies large image while retaining all of light. Facilities candidates for use of focusing schlieren include low-speed wind and water tunnels. Heated or cooled flow tracers or injected low- or high-density tracers used to make flows visible for photographic recording.

Weinstein, Leonard M.↗

Self-focusing of whistler waves

The theory of axially symmetric self-focusing of whistler waves, based on the full system of Maxwell equations, is developed. The plasma is described by the magnetohydrodynamic equations including the ponderomotive force from RF field. The nonlinear Schrodinger equations (NSE) for arbitrary azimuthal modes of whistler waves are derived. It is shown that they differ from the NSE for a scalar field; this is connected with an intrinsic angular momentum due to the rotating polarization of whistlers. It is shown that the self-focusing, as described by the NSE, differs in its final stage from the results following the full set of Maxwell equations. The latter gives defocusing after sufficient narrowing of the initial wave beam, due to transformation of the trapped wave into a nontrapped branch which is not contained in the NSE description. The oscillatory character of the defocusing is demonstrated.

Karpman, V. I.↗

A wind tunnel application of large-field focusing schlieren

A large-field focusing schlieren apparatus was installed in the NASA Lewis Research Center 9 by 15 foot wind tunnel in an attempt to determine the density gradient flow field of a free jet issuing from a supersonic nozzle configuration. The nozzle exit geometry was designed to reduce acoustic emissions from the jet by enhancing plume mixing. Thus, the flow exhibited a complex three-dimensional structure which warranted utilizing the sharp focusing capability of this type of schlieren method. Design considerations concerning tunnel limitations, high-speed photography, and video tape recording are presented in the paper.

Ponton, Michael K.↗

FOCUS - An experimental environment for fault sensitivity analysis

FOCUS, a simulation environment for conducting fault-sensitivity analysis of chip-level designs, is described. The environment can be used to evaluate alternative design tactics at an early design stage. A range of user specified faults is automatically injected at runtime, and their propagation to the chip I/O pins is measured through the gate and higher levels. A number of techniques for fault-sensitivity analysis are proposed and implemented in the FOCUS environment. These include transient impact assessment on latch, pin and functional errors, external pin error distribution due to in-chip transients, charge-level sensitivity analysis, and error propagation models to depict the dynamic behavior of latch errors. A case study of the impact of transient faults on a microprocessor-based jet-engine controller is used to identify the critical fault propagation paths, the module most sensitive to fault propagation, and the module with the highest potential for causing external errors.

Choi, Gwan S.↗

Aerodynamic investigation with focusing schlieren in a cryogenic wind tunnel

A flow visualization study was performed using a focusing schlieren system in the 0.3m Transonic Cryogenic Tunnel at NASA Langley Research Center. The design employed proved to be a useful flow visualization tool for flows as low as M = 0.4. This study marked the first verification of the focusing schlieren technique in a major subsonic/transonic wind tunnel, and the first time that high quality, detailed pictures of high-Reynolds number flows were obtained in a cryogenic wind tunnel. This test was part of a development program to implement instrumentation techniques in cryogenic wind tunnels, with the ultimate aim to use them in the National Transonic Facility (NTF).

Gartenberg, Ehud↗

SPECFOCUS: An IRAF task for focusing spectrographs

An IRAF task for measuring the point-spread function (PSF) along the dispersion and wavelength shifts across the dispersion in two dimensional arc spectra is described. In typical use, a set of spectra are obtained with various spectrograph focusing and alignment adjustments and the PSF information and shift information is derived and presented in tabular and graphical forms. Within each image the spectra may be divided into a number of samples along the dispersion and across the dispersion to investigate variations at different points in the detector at fixed focus settings. With many spectra and many samples interpreting the measurements is challenging. The task provides an interactive graphical interface to display the measurements in a number of interesting ways. The underlying algorithm for measuring the PSF and shifts in the auto/cross-correlation of spectral are samples.

Valdes, F.↗

Flux-focusing eddy current probe and method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material is presented. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗

Flux-focusing eddy current probe and rotating probe method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Buzz A.↗

Aerodynamic Investigation with focusing schlieren in a cryogenic wind tunnel

A flow visualization study was performed using a focusing schlieren system in the 0.3m Transonic Cryogenic Tunnel at NASA Langley Research Center. The system proved to be a useful flow visualization tool for flows as low as M = 0.4. This study marked the first verification of the focusing schlieren technique in a major subsonic/transonic wind tunnel and the first time that high-quality, detailed pictures of high-Reynolds-numbers flows were obtained in a cryogenic wind tunnel. This test was part of a development program to implement instrumentation techniques in cryogenic wind tunnels, with the ultimate aim to use them in the National Transonic Facility (NTF).

Gartenberg, Ehud↗

Sonic Boom Ocean Penetration: Noise Metric Comparison and Initial Focusing Results

The purpose of the present research is to determine the impact by sonic boom noise penetration into the ocean. Since the 1994 LaRC High Speed Research Program Sonic Boom Workshop several new results have been obtained. This talk reviews these results, and emphasizes the two most important findings. The first major result is an improved understanding of the noise spectra of the penetrating sonic boom. It was determined that weighted sound exposure levels decrease with deeper ocean depths significantly faster than unweighted sound exposure levels. This is because low frequencies penetrate the ocean deeper than high frequencies. Several noise metrics were used including peak, SEL, C-SEL, A-SEL, and PLdB, and results are given for all. These results are important because they show that the sonic boom noise impact on marine life a few meters below the ocean surface may be significantly lower using weighted sound levels than if one were to measure the impact using unweighted levels. The other major finding is the first estimate of the worst case peak levels produced by a penetrating sonic boom being focused by a sinusoidal ocean surface. The method of analysis chosen was computational, a time domain finite difference algorithm. The method is outlined and then example results are presented. For rounded sonic boom waveforms incident on a sinusoidal ocean surface, it is shown that the percentage increase or decrease in pressure is only occasionally larger than 10%, rarely 25%. These fluctuations indicate, under the assumptions already given, that any increase or decrease in sound level underwater due to focusing or defocusing should be small, less than 3 dB.

Sparrow, Victor W.↗

Application of Bacteriorhodopsin Films in an Adaptive-Focusing Schlieren System

The photochromic property of bacteriorhodopsin films is exploited in the application of a focusing schlieren optical system for the visualization of optical phase information. By encoding an image on the film with light of one wavelength and reading out with a different wavelength, the readout beam can effectively see the photographic negative of the original image. The potential advantage of this system over previous focusing schlieren systems is that the updatable nature of the bacteriorhodopsin film allows system adaptation. I discuss two image encoding and readout techniques for the bacteriorhodopsin and use film transmission characteristics to choose the more appropriate method. I demonstrate the system principle with experimental results using argon-ion and He-Cd lasers as the two light sources of different wavelengths, and I discuss current limitations to implementation with a white-light source.

Downie, John D.↗