Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On Feature, Classifier and Detector Fusers for 235U Signatures Using Gamma Spectral Counts

Three types of information fusion strategies are studied to assess the performance of classifiers for detecting low-level 235 U radiation sources, using features obtained from gamma spectra of NaI detectors. These three strategies are based on using two spectral region features, fusing eight classifiers of diverse designs, and fusing multiple detectors located at different positions around the source. The inner, middle and outer groups of detectors, within a formation of two concentric circles and a spiral of 21 detectors, are identified based on their distance to the source, which is located at the center. This study provides two main qualitative insights into this classification task. First, the fusion of detectors leads to an overall improved classification performance, least in the inner group, most in the outer group, and in between for the middle group. Second, several classifiers and fusers achieve lower training error which does not translate to lower generalization error, indicating their over-fitting to training data.

Rao, Nageswara↗

Reactor Facility Operational State Classification Using Gas Effluents and Radiation Measurements

Inferring the operational state of a reactor facility, using measurements from an independent in-situ monitoring system, is critical to the assessment of its compliance to agreements. We consider the problem of inferring the on/off operational state of a facility by using gas effluents and radiation measurements collected at the reactor's off-gas ventilation stack and within its surrounding area. Effluent release concentrations of three noble gases, namely, Ar-41, Cs-138, and Xe-138, are collected inside the ventilation stack and provided every four hours. Gamma spectra is recorded every second by a radiation detector located about 100 meters offset from the stack, which is affected by weather and nearby conditions. We study classifiers based on the correlation coefficient (CC) method [1] applied to individual modalities and their combinations. We implement CC classifiers using ground truth measurements collected over 2 operational cycles of High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) in year 2017.

Ramirez Aviles, Camila A.↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

MO-FG-303-08: PET-Detectable Bimetallic (Zn@Au) Nanoparticles for Radiotherapy and Molecular Imaging Applications

Purpose: A technical challenge in clinical translation of GNP-mediated radiotherapy is lack of in-vivo imaging tools for monitoring biodistribution of GNPs. While several modalities (x-ray fluorescence, photoacoustic, etc.) are investigated, we propose a potentially more effective technique based on PET imaging. We developed Zn@Au NPs whose Zn core acts as positron emitters when activated by protons, while the Au shell plays the original role for GNP-mediated radiosensitization. Methods: Spherical Zn NPs (∼7nm diameter) were synthesized and then coated with ∼7nm thick Au layer to make Zn@Au NPs (∼20nm diameter). A water slurry containing 29mg of Zn@Au NPs was deposited (<10µm thickness) on a thin cellulose target and subsequently baked to remove the water. The cellulose matrix was placed in an aluminum target holder and irradiated with 14.5MeV protons from a GE PETtrace cyclotron with 4µA for 5min. After irradiation the cellulose matrix with the NPs was placed in a dose calibrator to assay radioactivity. Gamma spectroscopy using a HPGe detector was conducted on a very small fraction (<1mg) of the irradiated NPs. Results: We measured 158µCi of activity 32min after end of bombardment (EOB) using 66Ga setting on the dose calibrator (contribution from the cellulose matrix is negligible) which decreased to 2µCi over a 24hrs period. A gamma spectrum started one hour after EOB on the small fraction and acquired for 700sec showed a strong peak at 511keV (∼40,000 counts) with several other peaks (highest peak <1200 counts) of smaller magnitude. Conclusion: Strong 511keV gamma emission from proton-activated Zn cores can potentially be utilized to image the biodistribution of Zn@Au NPs using a PET scanner. The developed Zn@Au NPs are expected to retain radiosensitizing capability similar to solid GNPs, while observable through PET imaging for human-sized objects. Moreover, bioconjugated PET-detectable GNPs would allow a new option to perform molecular imaging.

60 APPLIED LIFE SCIENCES↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Code for BALDR Study 07.04

SAND2024-11256O The Code for BALDR Study 07.04 software reproduces results from the BALDR study concerning "Multilabel Proportion Prediction and Out-of-Distribution Detection on Gamma Spectra of Short-Lived Fission Products." This code can reproduce a scientific study following the step numbers present in the file names. The scientific study uses synthetic and measured data to find the best model for the radioisotope proportion estimation task of interest and generates results. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Morrow, Tyler↗

Full Rod Length Gamma Spectroscopy Measurements of LWR Used Fuel Rods

Twenty-five high-burnup pressurized water reactor used fuel rods were scanned in the Irradiated Fuels Examination Laboratory at Oak Ridge National Laboratory with a high-resolution gamma spectrometer. A planar high-purity germanium detector was used across an energy range from 60 keV to 3 MeV. Gamma spectra of individual fuel rods were collected in 4.5 mm steps along the entire length of each rod. Additional spectra were collected on select rods in rotational increments of 30 degrees to provide data on the distribution of fission products along the rod perimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of the Graduate Mentoring Assistance Program for PNNL PNNL.12.006 (April 2012 – May 31, 2013)

Summary of Students and Projects: Sarah Bender: The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. For Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark: Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman: The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.

Schwantes, Jon M.↗

Special Nuclear Material Gamma-Ray Signatures for Reachback Analysts

These are slides on special nuclear material gamma-ray signatures for reachback analysts for an LSS Spectroscopy course. The closing thoughts for this presentation are the following: SNM materials have definite spectral signatures that should be readily recognizable to analysts in both bare and shielded configurations. One can estimate burnup of plutonium using certain pairs of peaks that are a few keV apart. In most cases, one cannot reliably estimate uranium enrichment in an analogous way to the estimation of plutonium burnup. The origin of the most intense peaks from some SNM items may be indirect and from ‘associated nuclides.' Indirect SNM signatures sometimes have commonalities with the natural gamma-ray background.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INITIAL UC Davis Reactor Analysis Context

The INITIAL reactor experiment pitched to UC Davis and agreed upon by the professor teaching the course is a natural uranium neutron activation experiment in the McClellan Nu- clear Research Center (MNRC) reactor. Both non-cadmium covered (Ex:1 – bare) and cadmium covered (Ex:2 – Cd) experiments will be performed and analysis will ensure on gamma spectra collected from both experiments. The following provides necessary information for completing the experiment analysis. This information includes definitions, assumptions, and plots tailored to the specifics of this experiment. The content is for the students to be completing the laboratory for reference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Annual IPCA2 Performance Report for JFY18

This report summarizes the results of monthly control measurements of IPCA2 performed over the period of October 2018 through March 2019 and represents an annual performance overview for JFY18. Note that the start of the measurements in October 2018 was defined by the start of the contract agreement. Monthly measurements of Plutonium neutron detection efficiency, AmLi stability, Curium stability and HPGe gamma spectra of Plutonium standards were performed and analyzed. All the results are shown with respect to original control bounds established from 2013- 2017 data in. Updated control bounds established based on this JFY18 data for use during JFY19 measurements are summarized in Appendix A. Based on Pu efficiency measurements, the performance of the IPCA2 during this reporting period was stable within 0.6% at 1 σ level. Measurements were compared to room temperature and humidity and no dependence was found for any detector performance. The end of this report contains summary of all IPCA2 measurements performed since October 2018 and includes discussion of troubleshooting and repair activities performed over the reporting period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated scintillator array response to relativistic electrons

In order to make time resolved measurements of the gamma spectra on DARHT Axis 2 using the Compton Spectrometer (CS), the electron detector in the focal plane must be a scintillator that is optically coupled to a gated or streak camera. There are several issues we would like to address with experiments at Idaho Accelerator Center (IAC) before committing to a full size array (7”x2”), which would cost at least $100k. Two candidates for this application are organic (Bicron 422 or equivalent) or inorganic (LYSO) scintillator. Monte Carlo calculations were performed by Rachel Morneau, P-21, using MCNP to compare the two materials each 1.5mm thick for an energy range of 0.1 to 20MeV. The energy loss per particle in LYSO is much larger (100x) than in the plastic scintillator. We confirmed, by performing experiments with the CS on the Microton, that sensitivity of the LYSO was much larger (10x) than the plastic scintillator. Therefore, we have selected LYSO as the scintillator of choice. However, interest in the response of other organic and plastic scintillators prompted an increase in scope of the project. The goals of this experiment were as follows. First, we need to understand the optical response of the scintillators to electrons as a function of thickness, energy, and deposited charge. We also need to verify level of saturation in the scintillation process. Second, compare the scintillators’ response to an image plate (the current CS detector). Third, we need to quantify the effect of signal bleed through to adjacent pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium Immobility in Tims Branch Wetland

The objective of this study was to address an item identified by the Low-Level Waste Disposal Facility Federal Review Group (LFRG) panel during their review of the Savannah River Site’s Composite Analysis. Their concern was that the Tims Branch wetland, which has elevated levels of uranium (U) originating from site operations between 1952 to 1985, may be a secondary source term, posing a human health risk. This report briefly describes three studies dealing with: 1) quantifying the mass of U remaining in the wetland, 2) quantifying the tendency of U to release from Tims Branch sediment, and 3) describing the distribution of U in aqueous and suspended solids in Tims Branch water during episodic storm events. The Tims Branch wetland has been extremely effective for the last 50 years at immobilizing U released to the system. A detailed map including 270,000 gamma spectra of the U distribution in the wetland indicated that 84% of the initial 43,500 kg U introduced in the system remain there after 50 years (Kaplan et al., 2020). The effectiveness of immobilizing U is supported by stream water measurements collected over the last several decades indicating that U concentrations have been consistently below drinking water regulatory limits (i.e., the EPA Maximum Contaminant Level, 30 pg/L (SRNS, 2019)). Furthermore, using contaminated Tims Branch sediments, in situ desorption Kd values (ratio of U sediment/U Water) were extremely high, ranging from 104to 106 L/kg, suggesting the U is strongly bound to these wetland sediments. Finally, a detailed study of Tims Branch stream water properties during episodic rain events indicated that essentially all the U transported in this stream was associated with suspended solids (Batson et al., 1996). Together these findings indicate that the Tims Branch wetland is extremely effective in its present state at immobilizing U and that the small masses of U released downstream will be predominantly in association with suspended solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Dependent Fission Product Yields

This project utilized a 10-meter Fast Transfer System (called RABITTS) and Decay Station. FPYs are measured using neutron activation of U-235 and Pu-239 followed by gamma ray spectroscopy. We irradiated targets with mono-energetic neutrons produced at the TUNL tandem accelerator laboratory. The gamma spectra collected in these target irradiations are being analyzed to determine FPY values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Machine Learning Algorithm for Pebble Bed Modular Reactor Misuse Detection

The objective of this work was to develop a machine learning ensemble that could assist pebble bed reactor verification by evaluating whether a given pebble circulating through a PBR was normal or anomalous using gamma spectroscopy measurements from a notional PBR burnup measurement system. Using a PBR reference design, data sets of synthetic gamma spectra representative of BUMS measurements of normal and anomalous pebbles that may be used to produce special fissile material were generated to train and test an ML anomaly detection ensemble on two reference scenarios – substitution of normal pebbles with target pebbles for production of Pu or 233 U. The ML ensemble correctly identified all anomalous pebbles in the testing data set, and while perfect ensemble performance is normally indicative of overfitting, it was concluded that significantly lower photon intensity of target pebbles produced distinctly less intense photon spectra to where perfect ensemble performance was expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

"Isotopics by nuclides" tool performance in InterSpec

This report provides a performance summary of the “Isotopics by Nuclides” tool in InterSpec. The primary objective of the NA-241 FY25 project was the detection and characterization of non-homogeneous uranium samples. However, the tool also demonstrates effectiveness in determining the enrichment of homogeneous uranium or plutonium from single gamma spectra. This paper presents a subset of evaluated data to avoid distribution limitations while offering potential users’ insight into the tool's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Self-interrogation Safeguards Signatures for Pebble Bed Reactor Fuel

New reactor designs, such as pebble-bed reactors, present challenges for the safeguarding of fissile material. Due to the multi-pass fuel circulation design and the non-uniform path a pebble may traverse through a pebble-bed reactor, there will be variations in the irradiation history of spent fuel pebbles. The standard approach of estimating actinide quantities based on fission gamma spectra or neutron emission paired with depletion modeling may yield uncertainties too large for safeguards and material accountancy. This project investigated, through modeling and experimentation, the potential of neutron self-interrogation of spent fuel pebbles as an innovative method to implement materials accountability. As an example, our feasibility studies indicate that the mass of U-235, U-238, Pu-239 and Pu-241 can be predicted to 4.1, 0.86, 13 and 13 % accuracy, respectively, when measuring 100 closely packed end-of-life spent fuel pebbles over approximately 12 days using a 4π counting geometry.