Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gait”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

186 records · Page 11

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

NASA Open Science Data Repository: Biomedical FAIR Data, Analysis Tools, User Communities, and Discoveries for Deep Space Missions

Increased biomedical risks and challenges associated with deep space missions require new knowledge discovery, new health countermeasures, and development of novel ecosystems, life support, crop production, and biomedical support capabilities. To meet NASA’s Moon to Mars strategic program goals for Human and Biological Sciences, findable, accessible, interoperable, reusable (FAIR), and maximally open-access data is going to be required to enable humanity to thrive in deep space. Indeed, this cornerstone perspective on FAIR and maximally open access data was also recommended in the recent 2023-2032 Decadal Survey from the National Academies of Sciences, Engineering, and Medicine. The NASA Open Science Data Repository (OSDR) is a maximally open access and FAIR database, and meets various scientific, technical, and operational spaceflight needs. It offers public users and submitters the ability to upload, download, search, share, analyze, and visualize data across ‘omics, physiological, phenotypic, behavioral, bioimaging, video, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive, and the NASA Biological Institutional Scientific Collection. OSDR has >455 studies with datasets from model organisms and non-NASA human astronauts. There are ~12 datasets from the Inspiration 4 (I4) mission, spanning metagenomics, comprehensive metabolic panels, clonal hematopoiesis, spatial transcriptomics, proteomics, and cytokine panels. In the interest of data privacy, two I4 datasets have raw FASTQ and FASTA files relating to the epitranscriptome, and a new request feature is live in OSDR (with a backend review process established) which was developed based on industry norms. OSDR also recently began a collaboration with the European Space Agency (ESA) to scientifically curate and make available >200 terabytes of human and model organism space-relevant data. The OSDR submission portal is designed to ingest and curate ~25 ‘omics assay data types, and ~50 physiological-phenotypic-imaging assay data types, spanning ultrasonography, micro-computed tomography, histology, morphometric photography, rebound tonometry, gait analysis, optical coherence tomography, novel object recognition, flow cytometry, and immunohistochemistry. A suite of analysis tools are available for OSDR users including: 1) an Environmental Data Application to compare radiation, CO2, relative humidity, temperature, and other telemetry across missions and subjects, 2) the RadLab database, a collaboration between NASA, ESA, the German and Italian Space Agencies, and the Bulgarian Academy of Sciences, which compiles radiation measurements relevant to human spaceflight and provides tools for accessing and manipulating the data, and 3) a Multi-study visualization tool which enables users to look across and combine GeneLab’s omics datasets across different experiments and missions. There are ~600 volunteer OSDR Analysis Working Group (AWG) members who: 1) provide feedback on scientific standards for reuse (subject and assay metadata; processing pipelines; dataset formats and uniformed structures for machine-readability), and 2) collaborate to mine-reuse OSDR data conducting scientific analysis. OSDR has enabled 60 publications as of September 2023, many directly from AWG collaborations most notably the Cell Press package in 2020. Lastly, there are at least 15 articles which mine OSDR data part of a package of ~50 articles across Nature Portfolio with research stemming from I4, the Japan Aerospace Exploration Agency, NASA Space Biology, and the NASA Human Research Program.

open access↗

Volumetric Assessment of UPRITE Exercises From Marker-Based Motion Capture

BACKGROUND Lack of volumetric data on full-body movement of exercises presents a challenge to ensuring the fit of crew member’s full range of motion on the International Space Station (ISS). The Upright Proprioception Retention via In-flight Training and Evaluation (UPRITE) is a sensorimotor countermeasure device designed for maintaining crew members’ proprioception in a microgravity environment. A footplate—attached to a static base—rotates in two degrees of freedom (pitch and roll) up to a 20 deg angle. An initial volumetric assessment assuming an upright standing posture produced a cone-like shape with a narrow bottom and wide top. Such general volumetric assessments risk creating an overly conservative volume estimate, taking up more space than is necessary on the already limited interior space of the ISS, and neglecting necessary volume due to oversimplifying assumptions. Rather, higher-fidelity volumetric assessments offer more comprehensive insights in an environment where every area counts. The main objective of this work is to provide the spatial parameters of exercises on the UPRITE such that it is placed on the ISS according to its volumetric demands or that usage is adjusted to fit the available space. METHODS In 2023, a data collection was performed originally to inform loads and dynamics of system use and was recently leveraged for volumetric assessment. Three human subjects representing different body types (~63-76 inches in stature) performed a variety of board manipulations using UPRITE with body weight offload. The test collected the 3D positional data of a modified full-body Plug-in Gait marker set [1] via a 16-camera OptiTrack MoCap system. After processing – filling marker gaps and trimming data – in OptiTrack Motive, the recorded marker location data, which included device markers, was exported to a readable trajectory file. To accurately represent the full volume defining landmarks, additional markers were digitally added to an unscaled Modified Full Body Model [2]. The model was then scaled according to its subject parameters upon which an inverse kinematics analysis was performed. A custom plugin yielded model marker location data files. Volumetric analyses were performed on the recorded trajectory and model trajectory files using a custom Python-built tool that extracted the marker location data and plotted it in a 3D space. Concerned with only the maximum volume of the motion, a 3D convex hull analysis was applied to the plot, extracting the vertices or external points of the eventual 3D CAD output, dubbed aptly as a “volume shell”. This overall approach was based on guidance in a NASA-STD-3001 Technical Brief [3]. RESULTS AND DISCUSSION Batch volumetric assessment on the exercises for each subject was performed, producing high-fidelity volume shells in minimal time. Preliminary results highlighted the value in higher-fidelity volumes based on collected data when possible. For example, revolving a single posture in the cone assessment would not have sufficiently captured a single leg stance; rather, it would need to involve swinging the leg both forward and back. Additional observations and the maximal dimensions of the volumes, including those based on scaled data for ISS anthropometric requirements, will be presented at the Human Research Program Investigator’s Workshop. CONCLUSIONS While this work’s primary objective was for the UPRITE-to-ISS integration, the tool built to conduct this analysis has wide applications for future exercise systems as an informational tool for optimal device placement. The tool and its findings also have implications for exercise device design and spacecraft interior considerations on Gateway, the Lunar Pressurized Rover, and beyond. REFERENCES [1] Bell, C. A., et al. (2023) Recent Improvements and Verification of a Full Body Model in OpenSim. NASA Human Research Program Investigator’s Workshop. https://ntrs.nasa.gov/citations/20230001080 [2] Lostroscio, K., et al (2023) The Digital Astronaut Simulation. AHFE International Conference on Human Factors in Design, Engineering, and Computing for All. [3] Exercise Overview. (2023) NASA-STD-3001 Technical Brief. https://www.nasa.gov/wp-content/uploads/2023/12/ochmo-tb-031-exercise-overview.pdf?emrc=9d454c?emrc=9d454c

L D Quinto↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Increased walking variability in elderly persons with congestive heart failure

OBJECTIVES: To determine the effects of congestive heart failure on a person's ability to walk at a steady pace while ambulating at a self-determined rate. SETTING: Beth Israel Hospital, Boston, a primary and tertiary teaching hospital, and a social activity center for elderly adults living in the community. PARTICIPANTS: Eleven elderly subjects (aged 70-93 years) with well compensated congestive heart failure (NY Heart Association class I or II), seven elderly subjects (aged 70-79 years) without congestive heart failure, and 10 healthy young adult subjects (aged 20-30 years). MEASUREMENTS: Subjects walked for 8 minutes on level ground at their own selected walking rate. Footswitches were used to measure the time between steps. Step rate (steps/minute) and step rate variability were calculated for the entire walking period, for 30 seconds during the first minute of the walk, for 30 seconds during the last minute of the walk, and for the 30-second period when each subject's step rate variability was minimal. Group means and 5% and 95% confidence intervals were computed. MAIN RESULTS: All measures of walking variability were significantly increased in the elderly subjects with congestive heart failure, intermediate in the elderly controls, and lowest in the young subjects. There was no overlap between the three groups using the minimal 30-second variability (elderly CHF vs elderly controls: P < 0.001, elderly controls vs young: P < 0.001), and no overlap between elderly subjects with and without congestive heart failure when using the overall variability. For all four measures, there was no overlap in any of the confidence intervals, and all group means were significantly different (P < 0.05).

NASA Discipline Cardiopulmonary↗

Recovery of postural equilibrium control following spaceflight

Decreased postural stability is observed in most astronauts immediately following spaceflight. Because ataxia may present postflight operational hazards, it is important to determine the incidence of postural instability immediately following landing and the dynamics of recovery of normal postural equilibrium control. It is postulated that postflight postural instability results from in-flight adaptive changes in central nervous system (CNS) processing of sensory information from the visual, vestibular, and proprioceptive systems. The purpose of the present investigation was to determine the magnitude and time course of postflight recovery of postural equilibrium control and, hence, readaptation of CNS processing of sensory information. Thirteen crew members from six spaceflight missions were studied pre- and postflight using a modified commercial posturography system. Postural equilibrium control was found to be seriously disrupted immediately following spaceflight in all subjects. Readaptation to the terrestrial environment began immediately upon landing, proceeded rapidly for the first 10-12 hours, and then proceeded much more slowly for the subsequent 2-4 days until preflight stability levels were reachieved. It is concluded that the overall postflight recovery of postural stability follows a predictable time course.

NASA Discipline Neuroscience↗